• Title/Summary/Keyword: Receiver sensitivity

Search Result 580, Processing Time 0.027 seconds

Receiver operating characteristic curve analysis of the timed up and go test as a predictive tool for fall risk in persons with stroke: a retrospective study

  • Lim, Seung-yeop;Lee, Byung-jun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.2
    • /
    • pp.54-60
    • /
    • 2018
  • Objective: Persons with chronic stroke fall more often than healthy elderly individuals. The Timed Up and Go test (TUG) is used as a fall prediction tool, but only provides a result for the total measurement time. This study aimed to determine the optimal cut-off values for each of the 6 components of the TUG. Design: Retrospective study. Methods: Thirty persons with chronic stroke participated in the study. TUG evaluation was performed using a wearable miniaturized inertial sensor. Sensitivity, specificity, and predictive values were calculated using the Receiver Operating Characteristic (ROC) curve analysis for the measured values in each section. Optimal values for fall risk classification were determined. Logistic regression analysis was used to investigate the risk of future falls based on TUG. Results: The cut-off values of the 6 sections of the TUG were determined, as follows: sit-to-stand >2.00 seconds (p<0.05), forward gait >4.68 seconds (p<0.05), mid-turn >3.82 seconds (p<0.05), return gait >4.81 seconds (p<0.05), end-turn >2.95 seconds (p<0.05), and stand-to-sit >2.13 seconds (p<0.05). The risk of falling increased by 2.278 times when the mid-turn value was >3.82 seconds (p<0.05). Conclusions: The risk of falls increased by 2.28 times when the value of the mid-turn interval exceeded 3.82 seconds. Therefore, when interpreting TUG results, the predictive accuracy for falls will be higher when the measurement time for each section is analyzed, together with the total time for TUG.

Implementation of Ka-band Satellite Broadcasting/LNB with High Dynamic Range (Ka-band 고감도 위성방송용/LNB 최적화 설계)

  • Mok, Gwang-Yun;Lee, Kyung-Bo;Rhee, Young-Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.66-69
    • /
    • 2016
  • In this paper, we suggests a Ka-band LNB considering next-generation UHD satellite TVRO. Since Ka-band has grater attenuation than Ku-band in atmosphere, we designed the low-noise down-converter to improve receiving sensitivity and to extend a dynamic range of receiver. It aims to compensate a quality of ultra high definition transmission signal for rainfall. The low-noise block diagram consists of a three-staged amplifier (LNA), band-pass filter for deleting image (BPF), mixer and IF when considering nonlinear characteristics in the receiver RF front end module. Also, we showed a LNB through optimization processes affecting dynamic range directly in receiver FEM. Asa resuly of experiment, the gain of low-noise down-converter show between 58.5dB and 60.7dB, the noise figure has a high characteristic as 1.38dB. Finally, the phase noise of local oscillator is -63.10dBc at 100MHz offset frequency.

  • PDF

Transabdominal Ultrasound Assessment of the Polycystic Ovary Syndrome (다낭난소증후군 진단시 복식 초음파의 유용성에 관한 연구)

  • Jeong, Kyung-Ah;Lee, Woon-Jeong;Chung, Hye-Won
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.4
    • /
    • pp.255-263
    • /
    • 2009
  • Objective: The objective of the study was to determine the diagnostic performance of transabdominal ultrasound by receiver operating characteristic (ROC) curve analysis, in order to evaluate the usefulness in establishing the diagnosis of polycystic ovary syndrome (PCOS). Methods: Questionnaires were given to 8,793 reproductive women reviewed at Ewha Womans University Mokdong hospital. Ultrasound examinations were performed in 701 women with a transabdominal transducer. Transabdominal ultrasounds were performed in 185 normal control women (normal menstruation without hyperandrogenism or PCO morphology) and 248 PCOS patients according to National Institutes of Health (NIH) PCOS diagnosis criteria. ROC curves were calculated for ovarian volume and follicle number. Results: In normal control group, the mean age were $23.64{\pm}4.26$ years old and the mean ovarian volume and follicle number were $6.03{\pm}1.89\;cm^3$ and $6.49{\pm}1.93$, respectively. The ovarian volume showed an area under the ROC curve (AURC) of 0.761. A ovarian volume decision threshold >$9\;cm^3$ had a sensitivity of 51.0% and a specificity of 91.4% for the diagnosis of PCOS. The follicle number showed an AURC of 0.733. A follicle number decision threshold ${\geq}9$ had a sensitivity of 54.9% and a specificity of 87.0% for the diagnosis of PCOS. A follicle number decision threshold ${\geq}10$ had a sensitivity of 53.2% and a specificity of 90.4%. A follicle number and a ovarian volume did not have a high diagnostic power for screening for PCOS. Conclusion: Our results suggest that transabdominal ultrasound assessment is not effective for the detection of PCOS in young women of reproductive age.

Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images (초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과)

  • Yang, Jeong-Hwa;Kang, Gwan-Suk;Lee, Kyung-Sung;Paeng, Dong-Guk;Choi, Min-Joo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.277-283
    • /
    • 2009
  • It is important to get clinical ultrasonic images of good quality for accurate diagnosis. In this study, it observed the change of ultrasonic images against setting frequency, dynamic range(DR) and type of probes on ultrasonic scanner. In the experiment it evaluated image of LCS (Low Contrast Sensitivity) targets(-15, -6, -3, +3, +6, +15 dB) of a standard ultrasonic test phantoms(539,551, ATS, USA) similar to solid and cystic lesions. Its imaged from convex (C3-7IM) and linear probe (L5-12IM) on SA-9900 (Medison Ltd, Korea) scanner. The images obtained altering the setting parameters which are frequency(gen, pen, res, harmonic) mode and DR($40{\sim}100\;dB$). The quality of images evaluated compare with the nominal LCS value of target and measured LCS value. The results show that there was no significant changing of quality images altering DR 40, 60, 80, 100 dB against frequency in Convex probe but the image being the highest in LCS target at DR 60 dB, harmonic of frequency mode in the -15 dB target close to cystic lesion. In Linear probe, DR 40 dB, harmonic mode at -15 dB LCS target close to nominal value. It discussed necessity of evaluation about ROC(Receiver Operating Characteristic) from the psychological viewpoint and limit of evaluation from quantified images.

  • PDF

Detection of Extravasated Contrast Media Using an Infrared Ray Based Extravasation Detection Accessory System (적외선 기반의 혈관외유출 검출시스템을 이용한 조영제의 혈관외유출 검출)

  • Kweon, Dae-Cheol;Jang, Keun-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.5
    • /
    • pp.412-417
    • /
    • 2009
  • The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The extravasation detection accessory (EDA) system was based of infrared ray with detection sensor, an amplifier, alarm device, receiver, cable and a computer based system. This study was a prospective, observational study in which the EDA system was used to monitor the automated mechanical injection of contrast media. Three hundred patients referred for contrast media enhanced body computed tomography studied in a prospective, observation study in which the EDA system was used to identify and interrupt any injection associated with clinically important extravasation. There were 8 true-positive cases, 276 true-negative cases, 15 false-positive cases and 1 false-negative cases. The EDA system had a sensitivity of 88.8% and a specificity of 94.8% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

Evaluation of Bit Error Rate of a Long-Haul Optical Transmission System adopted the Mid-Span Spectral Inversion Method (Mid-Span Spectral Inversion 기법을 채택한 장거리 광 전송 시스템에서의 비트 에러율 평가)

  • Lee, Seong-Real;Kim, Nam-Sung;Bang, Hyo-Chang
    • Journal of Advanced Navigation Technology
    • /
    • v.6 no.3
    • /
    • pp.223-230
    • /
    • 2002
  • In this paper, we induced that the noise powers and bit error rate of direct detection receiver taking account of ISI (intersymbol interference) in the 2,000 km optical transmission system. And we evaluated the sensitivity in the vrious bit rate system. We verified that the proposed calculation method is applicable to the exact optical system. And we confirmed that the signal distortion due to both chromatic dispersion and nonlinear effects compensated by using of MSSI (Mid-Span Spectral Inversion) method, and yet the sensitivity of a higher bit rate system is reduced, because of the increase of ISI and then the decrease of the average receiving power, compared with a the lower bit rate system.

  • PDF

Diagnostic and Prognostic Importance of the Neutrophil Lymphocyte Ratio in Breast Cancer

  • Ozyalvacli, Gulzade;Yesil, Cemile;Kargi, Ertugrul;Kizildag, Betul;Kilitci, Asuman;Yilmaz, Fahri
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10363-10366
    • /
    • 2015
  • Background: The aim of this study was to determine diagnostic and prognostic roles of the neutrophil to lymphocyte ratio (NLR) in breast cancer patients. To date, data are limited on associations of primary breast carcinoma (PBC) and benign proliferative breast disease (BPBD) with preoperative NLR values. Materials and Methods: Our study covered of 120 female patients with PBC and 50 with BPBD. Diagnostic values of NLR were estimated using sensitivity, specificity and areas under receiver operating characteristic curves (AUC). Results: NLR values were significantly higher in the PBC patients than in those with BPBD, with an AUC of 0.668 in the PBC case. The optimal cut-off for NLR was 2.96 and this was validated in the testing set, giving a sensitivity and a specificity of 79.7% and 76.2%, respectively, in PBC patients. Conclusions: Preoperative high NLR is a significant diagnostic predictor of distinction of breast cancer from BPBD and elevated NLR is also an important prognostic marker for primary invasive breast cancer.

Predictive Value of Baseline Plasma D-dimers for Chemotherapy-induced Thrombocytopenia in Patients with Stage III Colon Cancer: A Pilot Study

  • Tanriverdi, Ozgur
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.293-297
    • /
    • 2013
  • Background: : Chemotherapy-induced thrombocytopenia (CIT) is an important cause of morbitity in patients with cancer. Aim: To investigate the effect of the baseline plasma D-dimer level, an important marker for thrombotic activity, on chemotherapy-induced thrombocytopenia in patients with stage III colon cancer. Materials and Methods: A total of 43 (28 men) eligible patients were divided into two groups according to whether they exhibited chemotherapy-induced thrombocytopenia: Group 1 (n=21) and Group 2 (n=22). Comparison was made using demographic, histopathologic, and laboratory variables. Additionally, baseline plasma D-dimer levels underwent receiver operation characteristics curve analysis, and areas under the curve were calculated. Sensitivity, specificity, and positive and negative likelihood rates were then determined. Results: The incidence of chemotherapy-induced thrombocytopenia had a significant correlation with baseline platelet count (r=0.568, P=0.031) and baseline plasma D-dimer levels (r=0.617, P=0.036). When the cut-off point for the latter was set as 498 ng/mL, the area under the curve was 0.89 (95%CI: 0.74-0.93), the sensitivity was 91.4%, the specificity was 89.7%, the positive likelihood rate was 3.64 and the negative likelihood rate was 0.24 for chemotherapy-induced thrombocytopenia diagnosis. Conclusions: The baseline level of plasma D-dimer could help to differentiate high-risk patients for chemotherapy-induced thrombocytopenia.

Reliability and Validity of Korean Geriatric Anxiety Inventory(K-GAI) (한국판 노인불안도구(K-GAI)의 신뢰도와 타당도)

  • Kim, Jiyun;Park, Myung Sook;Oh, Doo Nam
    • Journal of muscle and joint health
    • /
    • v.21 no.1
    • /
    • pp.75-84
    • /
    • 2014
  • Purpose: The purpose of this study was to test the validity and reliability of the Korean version of the Geriatric Anxiety Inventory (K-GAI). Methods: Two hundreds and thirty six elderly were participated to test K-GAI. Goldberg's short screening scale for anxiety was tested for criterion validity. Receiver operating characteristics (ROC) analysis was used for measuring sensitivity and specificity. Results: The obtained internal consistency was 0.88. There were significant associations between test and retest results. K-GAI scores was significantly associated with Goldberg's short screening scale for anxiety (r=.694, p<.001). We found that a score of seven and greater was optimal for a criterion of anxiety among elderly Koreans. At this cut point, sensitivity was 78.9% and specificity was 73.1%. Conclusion: The K-GAI displayed good psychometric properties. This tool would be useful for early detection of anxiety among elderly Koreans with various situations including cognitive disorder, low education, or physical disability.

Application of Quality Statistical Techniques Based on the Review and the Interpretation of Medical Decision Metrics (의학적 의사결정 지표의 고찰 및 해석에 기초한 품질통계기법의 적용)

  • Choi, Sungwoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.2
    • /
    • pp.243-253
    • /
    • 2013
  • This research paper introduces the application and implementation of medical decision metrics that classifies medical decision-making into four different metrics using statistical diagnostic tools, such as confusion matrix, normal distribution, Bayesian prediction and Receiver Operating Curve(ROC). In this study, the metrics are developed based on cross-section study, cohort study and case-control study done by systematic literature review and reformulated the structure of type I error, type II error, confidence level and power of detection. The study proposed implementation strategies for 10 quality improvement activities via 14 medical decision metrics which consider specificity and sensitivity in terms of ${\alpha}$ and ${\beta}$. Examples of ROC implication are depicted in this paper with a useful guidelines to implement a continuous quality improvement, not only in a variable acceptance sampling in Quality Control(QC) but also in a supplier grading score chart in Supplier Chain Management(SCM) quality. This research paper is the first to apply and implement medical decision-making tools as quality improvement activities. These proposed models will help quality practitioners to enhance the process and product quality level.