• Title/Summary/Keyword: Rebar spacing

Search Result 35, Processing Time 0.019 seconds

Effects of Transverse Reinforcement on Headed Bars with Large Diameter at Cut-off Points (컷오프 구간에 정착된 대구경 확대머리철근에 대한 횡보강근의 효과)

  • Jung, Hyung-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.82-90
    • /
    • 2018
  • The nuclear structures are composed of large diameter bars over No.36. If the hooked bars are used for anchorage of large diameter bars, too long length of the tail extension of the hook plus bend create congestion and make an element difficult to construct. To address those problems, headed bars were developed. Provisions of ACI 318-08 specify the development length of headed bars and ignore the effect of transverse reinforcement based on the background researches. However, if headed bars are used at the cut-off or lap splice, longitudinal reinforcements, which are deformed in flexural members, induce tensile stress in cover concrete and increase the tensile force in the transverse reinforcement. The object of this research is to evaluate the effects of transverse reinforcement on the anchorage capacity of headed bar so anchorage test with variable of transverse rebar spacing was conducted. Specimens, which can consider the behavior at the cut-off, were tested. Test results show that failure of specimen without transverse reinforcement was sudden and brittle with concrete cover lifted and developed stress of headed bars was less than half of yield strength of headed bars. On the other hand, in the specimen with transverse reinforcement, transverse rebar directly resist the load of free-end so capacity of specimens highly increased.

An Experimental Study on the Size and Length Effect of High Strength Concrete Specimens (고강도 콘크리트 시편의 치수 및 길이 효과에 관한 실험적 연구)

  • Kim, Dongbaek;Kim, Myunggon;Lee, Jeangtae;Song, Daegyeum
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.366-375
    • /
    • 2017
  • Internal factors having effects on compressive strength test results of concrete include size, shape, height-diameter ratio(h/d), section processing method, dryness and wetness, etc. of the specimen. As it is difficult to ensure dimensions of core specimen due to rebar cutting from rebar spacing, wall thickness, effects on the structure, etc. when taking core of the concrete structure, correction of dimensions and h/d of the specimen become important for quality control of the concrete. Thus, in order to review effects of specimen size and height-diameter ratio for the concretes with compressive strength within 40~60MPa, this study has experimentally reviewed compressive strength test values by applying correction factors pursuant to KS F 2422 (Method of obtaining and testing drilled cores and sawed beams of concrete), when changing specimen diameter to ${\emptyset}5{\sim}15cm$, and h/d to 2.0~1.25.

Structural Behaviour of TEC-BEAM Connection with Steel Column Under Cyclic Loading (반복하중을 받는 TEC-BEAM 철골브라켓 접합부 거동평가)

  • Ju, Young Kyu;Kim, Ji Young;Kim, Myeong Han;Jung, Kwang Ryang;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.1
    • /
    • pp.51-58
    • /
    • 2002
  • To reduce the story height for high-rise buildings, the TEC Beam is developed as a new composite beam composed of structural tee, precast concrete, stirrup, and site-in-cast reinforced concrete slab. The preliminary test of the proposed system was performed for simple beams and it showed a good behavior. However, for the field application of the system, it is required to develope a steel moment resisting connection using steel brackets on which upper rebars of the TEC BEAM are anchored. In this paper, three types of the proposed system are experimentally investigated. The parameters of the test are as follows: (1) the spacing of transverse bars, (2) the ratio of width of rebar's layer to bracket length. Specimens were classified as semi-rigid full strength by the Eurocode 4. It could be concluded that the proposed moment resisting system shows a good structural behavior and may be applicable in the filed.

Evaluation on the Horizontal Shear Strength of Precast Concrete Slab with the Inverted-Rib-Plus (리브플러스 PC슬래브의 수평전단강도 평가)

  • Park, Keum Sung;Lee, Sang Sup;Choi, Yun Cheul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.156-165
    • /
    • 2011
  • This study investigates the horizontal shear behavior of an interface between precast concrete (PC) and topping concrete(RC), and evaluates the horizontal based on the investigations by the experimental. Horizontal shear strength in connected surface is determined by the roughness an interface and the shear reinforcement or not. In this study, the main experimental parameters are the shear reinforcement types in the shape of loop-type and lattice-type, rebar spacing. A total of four specimens were shear strength tested and manufactured. As a result, the horizontal shear strength of reinforced connected surface was found to be controlled by deformation in vertical direction. Comparison of reinforcement shape, the mean initial crack load loop type specimens, the average maximum load and the junction of the average in terms of initial stiffness, respectively 33.7%, 45.9% and 55.2% were large enough. Evaluation results for shear strength equation of existing standard domestic, the loop-type reinforced 2.32 to 4.23 times, lattice-type reinforced 1.65 to 3.06 times appears to be higher. Behavior of interface or strength of structural design criteria was fairly safe side. It does not have any problems in the applied field is considered.

An Experimental Study on Concrete Bond Behavior According to Grid Spacing of CFRP Grid Reinforcement (격자형 CFRP 보강재의 격자간격에 따른 콘크리트 부착거동에 대한 실험적 연구)

  • Noh, Chi-Hoon;Jang, Nag-Seop;Oh, Hongseob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.73-81
    • /
    • 2022
  • Recently, as the service life of structures increased, the load-carrying capacity of deteriorated reinforced concrete, where corrosion of reinforcing bars occurs due to various causes, is frequently decreased. In order to address this problem, many studies on the bond characteristic of FRP (Fiber Reinforced Polymer) bars with corrosion resistance, light weight and high tensile strength have been conducted, however there are not many studies on the bond characteristic of grid-typed CFRP embedded in concrete. Therefore, in order to evaluate the bond characteristics of grid-typed CFRP and its usability as a substitute for steel rebar, a pull-out test is performed using the longitudinal bond length and transverse grid length of the grid-typed CFRP as variables. Through the pull-out test, the bond load-slip curve of the grid-typed CFRP is derived, and the bond behavior is analyzed. The total bond load equation is proposed as the sum of the bond force of the longitudinal bond length and the shear force of the grid in the transverse direction. Also, expressing the area of the bond load-slip curve as total work, the change in dissipated energy with respect to the slip is analyzed to examine the effect of the tranverse grid on the bond force.