• Title/Summary/Keyword: Reason of Fire Accident

Search Result 30, Processing Time 0.022 seconds

A study on the rescue design of passengers for railway tunnel fire accidents by using simulation program (터널 화재발생시 시뮬레이션 프로그램을 통한 승객대피계획)

  • Kwon, Soon-Sub;Lee, Jong-Sun;Lee, Kwan-Ho;Kwon, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1770-1773
    • /
    • 2007
  • Fire accident in tunnel is one of the most critical railway accidents, together with overturning of train by derailment and train crash. Tunnel structures contribute to minimize the cost and time of transport, but in case of railway fire accident occurring bring serious damages of human life caused by narrowness of shelter, poisonous smoke and high temperature raised at the inside of tunnel. For that reason, at the beginning of plan of tunnel, the optimum design for rescue of passengers is needed. For the detail and most suitable design for rescue of passengers, many tunnel designer substituted simulation program for mock examination by its high cost and effort. In this study, simulation program techniques, such as Fluent and Simulex, are applied for verifying the rescue design of passengers reduced the risk when fire accident occurred at tunnel utilizing of case study for planned railway tunnels shows 1,245m length in Iksan-Sili area.

  • PDF

A Study on safety against a fire of charging cable for mobile phone for vehicle (자동차용 모바일 폰 충전 케이블의 발화 안전성에 관한 연구)

  • Kwon, Jin-Wook;Choi, Kyu-Sik;Hwang, Myung-Whan
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.3
    • /
    • pp.21-26
    • /
    • 2018
  • This paper describes result of a study on safety against a fire of charging cable for mobile phone for vehicle. Combustion on the USB cable in the car was happened while driving. Gas coming from the burning USB cable could be a reason which can make a secondary car accident since the driver also can be embarrassed while driving. In order to prevent a secondary car accident connected on the road, to research a reason why USB cable can emit gas and be burned in charging. We did simulation test with abnormal fault condition for the electronic component on the board in the USB cable. So we get the result from abnormal fault condition simulation test, for instance, shorted test for output terminal of 8 pin switch, shorted test for chip resistor after thermal aging in the condition $25^{\circ}C$, 93 % RH during 48 hours. To analysis the result of all test, Combustion on the USB cable was not the 8 pin but other electrical component such as a chip resistor. Therefore we guess that the reason for USB cable combustion in charging in a car was not 8 pin and a LED but another defective component.

소방용 설비.기기 등의 동결방지 대책(1)

  • Lee, Bok-Yeong
    • Fire Protection Technology
    • /
    • s.11
    • /
    • pp.31-39
    • /
    • 1991
  • As the Present industry is developing, a structure and systems is tending increase. Therefore, the accident of freezing become intensified in our country, the continental climate zone of region in the middle degree. This paper is to analyze about the reason of freezing, principles to help avoid freeze, and so forth.

  • PDF

The Special Plan of the Traffic Accident Treatment in the Emergency Car Concerning Fire Fighting (소방관련 긴급자동차의 교통사고처리 특례방안)

  • Jeng, Gi-Sung
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.20-29
    • /
    • 2008
  • The traffic accident of Fire engine takes place very much, compared with that of the past. The reason is that there is a lot of the increase of the demand in the fire, rescue, first aid, and the public request. Also, because the Fire engine should go out at the place of the accident very quickly, it should inevitably violate the traffic regulations. Therefore, this is due to the traffic accident. Despite the urgent situation in the infringement motive of traffic regulations, the outbreak of the traffic accident does not vary largely from the degree of the disadvantage. Accordingly, a fire officer should take charge of his social and economic disadvantage by himself. In this situation, a fire officer has no choice but to start moving passively not to be afflicted with his own disadvantage. Most of the situations concerning the fire fighting are the ones to be controlled urgently. Nevertheless, because of the disadvantage of the traffic accident, passive mobilization of the fire fighting equipment is the heavy burden of all the people of the nation. Therefore, Special institutional safety device should be ready for the protection of the life and property of all people. The special law concerning the processing in the accident of the emergency car needs to be revised. By establishing this special law, the government should not provide the officer who drives the fire engine with the disadvantage caused by traffic accident.

Study on Probabilistic Analysis for Fire·Explosion Accidents of LPG Vaporizer with Jet Fire (Jet Fire를 수반한 국내외 LPG 기화기의 화재·폭발사고에 관한 확률론적 분석에 관한 연구)

  • Ko, Jae-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.31-41
    • /
    • 2012
  • This study collected 5,100 cases of gas accident occurred in Korea for 14 years from 1995 to 2008, established Database and based on it, analyzed them by detailed forms and reasons. As the result of analyzing the whole city gas accidents with Poisson analysis, the item of "Careless work-Explosion-Pipeline' showed the highest rate of accidents for the next 5 years. And, "Joint Losening and corrosion-Release-Pipeline" showed the lowest rate of accident. In addition, for the result of analyzing only accidents related to LPG vaporizer, "LPG-Vaporizer-Fire" showed the highest rate of accident and "LPG-Vaporizer-Products Faults" showed the lowest rate of accident. Also, as the result of comparing and analyzing foreign LPG accident accompanied by Jet fire, facility's defect which is liquid outflow cut-off device and heat exchanger's defect were analyzed as the main reason causing jet fire, like the case of Korea, but the number of accidents for the next 5 years was the highest in "LPG-Mechanical-Jet fire" and "LPG-Mechanical-Vapor Cloud" showed the highest rate of accidents. By grafting Poisson distribution theory onto gas accident expecting program of the future, it's expected to suggest consistent standard and be used as the scale which can be used in actual field.

The Cause Analysis of a Fire Accident on Boryeong Thermal Power Plant using New Public Management Theory (신공공관리론으로 바라본 보령화력발전소 화재 사고의 원인)

  • Lee, Wonjoo;Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.2
    • /
    • pp.268-281
    • /
    • 2019
  • Purpose: The purpose of this study was to find out how the administrative paradigm of the times affected the public sector's fire. Method: For this purpose, we investigated the New Public Management (NPM). In addition, the reasons of fire accident of Boryeong thermal power plant were analyzed in the limited values of NMP. Result: In theoretical investigation, the 3 values (managerial accountability, efficiency, expertise) of NMP and evaluation criteria were drew out. In investigation on reasons of fire accident, the improvement of accountability and expertise was insufficient due to the emphasis of the efficiency based on the introduction to free market by neoliberalism in public sector. Conclusion: In conclusion, we confirmed that the values of NMP were limited to forcingly apply to the public sector. This study is expected to contribute basic research references to fire administration theory.

A study on the fire safety evaluation of the urban rail vehicle (Fire characteristic evaluation of interiors) (도시철도차량 화재안전도 평가에 대한연구(I) (내장재 화재특성 평가 중심으로))

  • Jung, Woo-Sung;Lee, Duck-Hee;Lee, Cheul-Kyu;Lee, Ju-Bong
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.202-206
    • /
    • 2006
  • Although the urban rail vehicle is exposed to the fire disaster, most country, except only a few advanced country, is insufficient to take a measure against the fire accident. Safety regulation modification, fire safety standard of the materials. and each material's fire resistance of the rail vehicle have been upgraded until the Daegu fire disaster in Korea. For that reason, In this study, current techniques of fire safety evaluation are analyzed and fire safety degrees of rail vehicles are compared with the change of interiors which is met to the fire safety standard of urban rail vehicle.

  • PDF

Analysis of A Gas Explosion-Related State Compensation Case (가스폭발 사고와 관련된 국가배상 사례의 분석)

  • Lee, Euipyeong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.44-59
    • /
    • 2020
  • This study analyzed a gas explosion accident. A gas smell from a underground coffee shop in the two-story building was reported to 119. A fire brigade was turned out, turned off the main valve of LPG gas cylinder on the roof, and checked the turning off of middle valve in the coffee shop. The fire brigade required a gas supplier and gas installer who arrived at the spot to take safety actions. Gas explosion occurred seven minutes after the fire brigade was withdrawn and two people died and 21 people were injured. A court decided that because the causes for gas explosion were not found, compensation responsibility could not be charged with the gas supplier, the gas installer, or Korea Gas Safety Corporation. In this reason, the court judged that only the fire brigade who was withdrawn without taking safety actions shall compensate victims or bereaved families. Therefore, fire brigades who turn out after a 119 report of a gas leak should take safety actions such as escaping people or preventing people's access and ventilating and be withdrawn when there is no possibility of fire or explosion.

The Study on the Quantitative Analysis in LPG Tank's Fire and Explosion (LPG 저장탱크에서의 화재$\cdot$폭발에 관한 정량적 영향 평가에 관한 연구)

  • Bae Sung-Jin;Kim Byung-Jick
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.21-26
    • /
    • 1999
  • Chemical plant's fire and explosion does not only damage to the chemical plants themselves but also damage to people in or near of the accident spot and the neighborhood of chemical plant. For that reason, Chemical process safety management has become important. One of safety management methods is called 'the quantitative analysis', which is used to reduce and prevent the accident. The results of the quantitative analysis could be used to arrange the equipments, evaluate the minimum safety distance, prepare the safety equipments. In this study we make the computer program to make easy to do Quantitative analysis of the accident. The output of the computer program is the magnitude of fire(pool fire and fireball) and explosion(UVCE and BLEVE) effects. We used the thermal radiation as a measure of fire magnitude and used the overpressure as a measure of explosion magnitude. In case of BLEVE, the fly distance of fragment can be evaluated. Also probit analysis was done in every case. As the case study, Buchun LPG explosion accident in Korea was analysed by the program developed. The simulation results showed that the permissible distance was 800m and probit analysis showed that 1st degree bum, 2nd degree burn, and death distances are 450, 280, 260m, respectively the simulation results showed the good agreement with the results from SAFER PROGRAM made by Dupont.

  • PDF

A Study on Development of Arc Fault Circuit Interrupter Used in House Distribution Line (옥내 배전선로용 아크차단기 개발에 관한 연구)

  • Kwak, Dong-Kurl;Choi, Jung-Kyu;Park, Young-Jic;Kim, Jin-Hwan;Son, Jae-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.546-547
    • /
    • 2013
  • This paper proposes an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. It perceives a voltage instantaneously at the time of voltage drop. and occurrence. It is an AFCI of the new concept which operates with high reliability. The primary reason of electric fire is arc and spark. It prevents an electric fire or an electric leakage accident with quick responsiveness. Earth Leakage Circuit Breaker(ELB), Molded_case Circuit Breaker (MCCB) or Residual Current Protective Device(RCD) can not cut off electric arc or spark to be a major factor of electrical fire. This theory will be able to intercept an arc or a spark. which occurrence with periodic. Consequently It raises a reliability and validates a practicality of RCD.

  • PDF