• Title/Summary/Keyword: Reamer

Search Result 34, Processing Time 0.023 seconds

Cement Augmentation of Dynamic Hip Screw to Prevent Screw Cut Out in Osteoporotic Patients with Intertrochanteric Fractures: A Case Series

  • Rai, Avinash Kumar;Goel, Rajesh;Bhatia, Chirag;Singh, Sumer;Thalanki, Srikiran;Gondane, Ashwin
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.269-275
    • /
    • 2018
  • Purpose: The purpose of this study is to describe a method of inserting cement in the femoral head before fixation with dynamic hip screw to prevent screw cut out due to osteoporosis and to evaluate its clinical outcome in these patients. Materials and Methods: In this prospective study, 30 patients aged 60 years and older with intertrochanteric fracture were included. Bone mineral density was measured. After reaming of the femoral head and neck with a triple reamer and polymethyl methacrylate, bone cement was introduced into the femoral head using a customized nozzle and a barrel fitted on a cement gun. A Richard screw was inserted and the plate was fixed over the femoral shaft. Patients were mobilized and clinical outcomes were rated using the Salvati and Wilson's scoring system. Results: More patients included in this study were between 66 and 70 years old than any other age group. The most common fracture according to the Orthopaedic Trauma Association classification was type 31A2.2 (46.7%). The T-score was found to be $-2.506{\pm}0.22$ (mean${\pm}$standard deviation); all patients were within the range of -2.0 to -2.8. The duration of radiological union was $13.67{\pm}1.77$ weeks. Salvati and Wilson's scoring at 12 months of follow up was $30.96{\pm}4.97$. The majority of patients were able to perform their normal routine activities; none experienced implant failure or screw cut out. Conclusion: Bone cement augmentation may effectively prevent osteoporosis-related hardware complications like screw cut out in elderly patients experiencing intertrochanteric fractures.

Anterior Cruciate Ligament Double Bundle Reconstruction with Hamstring Tendon Autografts - Technical Notes (자가 슬괵건을 이용한 전방 십자 인대 이준 다발 재건술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Ahn, Hyung-Kwon;Kang, Hong-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.222-231
    • /
    • 2005
  • Purpose: This article describes a double-bundle ACL reconstruction technique using a five-strand hamstring tendon autograft with conventional anteromedial bundle reconstruction and additional posterolateral bundle reconstruction. Operative technique: For the tibial tunnel, the conventional single tunnel technique is performed and for the femoral tunnel, the double tunnel technique is performed with the anteromedial and posterolateral bundle. After minimal notchplasty, the anteromedial femoral tunnel is prepared with leaving one milimeter of posterior femoral cortex within the over-the-top, which if positioned at the 11-o'clock orientation for the right knee or at the 1-o'clock position for the left knee. The posterolateral femoral tunnel that is located 5 to 7 mm superior to the inner margin of the lateral meniscus anterior horn at $90^{\circ}$ of flexion is prepared with tile outside-in technique using a 4.5 cannulated reamer. The graft material for the double bundle reconstruction is made of the conventional four-strand hamstring autograft in the anteromedial bundle and of a single-strand semitendinosus tendon in the posterolateral bundle. The anteromedial bundle is fixed with using a rigid fix system on the femoral side and the posterolateral bundle is fixed to tie with the miniplate from the outside femur. Then, with the knee in $10^{\circ}\;to\;20^{\circ}$ of flexion, a bioabsorbable screw is simultaneously applied to achieve tibial fixation with tensioning of both bundles. Conclusion: A double bundle reconstruction with five-strand hamstring autograft, which is designed with a favorable conventional anteromedial bundle and an additional posterolateral bundle to restore rotation stability, seems to be a very effective method for the treatment for ACL instabilities.

  • PDF

EFFECT OF CURING METHODS OF RESIN CEMENTS ON BOND STRENGTH AND ADHESIVE INTERFACE OF POST (레진시멘트의 중합방법이 포스트의 결합강도와 접착계면에 미치는 영향)

  • Kim, Mun-Hang;Kim, Hae-Jung;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.103-112
    • /
    • 2009
  • The purpose of this study was to compare the effect of curing methods of adhesive resins and resin cements in the root canal. Crown portions of 32 single-rooted mandibular premolars were removed. Routine endodontic treatment was done, and 9 mm deep post spaces were prepared within root canals. No.3 FRC Postec posts (Ivoclar-Vivadent AG, Liechtensteih) were cemented in the post spaces by self-(SC) or light-curing (LC) using two dual-cured adhesives (Adper Scotchbond multi-purpose plus and Exite DSC )and resin cements (RelyX ARC and Variolink II). They were assigned to 4 groups (n=8): R-SC, R-LC, V-SC, V-LC group. After stored in distilled water for 24 hours, each root was transversally sectioned with 1.5 mm thick and made three slices. The specimens were subjected to push-out test in a universal testing machine (EZ Test, Shimadzu Co., Japan) with a crosshead speed of 1 mm/min. The data were analyzed with repeated ANOVA and one-way ANOVA. Also the interface of post-resin cement and resin cement-canal wall of each group was observed under FE-SEM. When fiber posts were cemented into the root canal using total-etch adhesives, the bond strength and adaptation between post and root canal dentin was affected by curing method. Self-cure of adhesives and resin cements showed higher bond strength and closer adaptation than light-cure of them.

ACL Reconstruction using Transtibial Femoral Tunnel at 10 or 2 O'clock Position - Technical Note - (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 - 수술 수기 -)

  • Cho, Sung-Do;Ko, Sang-Hun;Park, Mun-Soo;Jung, Kwang-Hwan;Cha, Jae-Ryong;Gwak, Chang-Youl;Kim, Sang-Woo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.209-213
    • /
    • 2006
  • Purpose: Conventional transtibial approach for the anterior cruciate ligament (ACL) reconstruction tended to place the femoral tunnel in too vertical position (11 or 1 o'clock), which could provide the postoperative anteroposterior (AP) stability but not provided the rotational stability. Therefore we present a surgical technique to make the transtibial femoral tunnel at 10 or 2 o'clock position. Surgical approach: To make a transtibial femoral tunnel at the 10 or 2 o'clock position, the direction and position of the tibial drill guide was important. We set the tibial drill guide at $40{\sim}45$ degrees and the intraarticular guide tip was 1 mm anterior and medial to the conventional site. The starting point for the guide pin on the proximal tibia was proximal to the pes anserinus and anterior to the medial collateral ligament. The tibial tunnel was initially drilled 1mm less than the diameter of the graft. Then femoral offset guide could be easily placed at 10 or 2 o'clock position through the tibial tunnel. The tibial tunnel and the femoral tunnel of 30 mm in length were made with the reamer that was same size with the graft. Conclusion: We report a surgical technique to create a transtibial femoral tunnel at 10 or 2 o'clock position in ACL reconstruction to provide the rotational stability as well as the AP stability.

  • PDF