• 제목/요약/키워드: Realtime Ultrasound

검색결과 9건 처리시간 0.01초

Studies on Intramuscular Fat Percentage in Live Swine Using Real-time Ultrasound to Determine Pork Quality

  • Jung, Jong-Hyun;Shim, Kwan-Seob;Na, Chong-Sam;Choe, Ho-Sung
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제28권3호
    • /
    • pp.318-322
    • /
    • 2015
  • In the modern pork industry, selection of high intramuscular fat (IMF) in pigs is necessary to improve pork quality. Ultrasound has been used previously to predict subcutaneous fat thickness and IMF in the longissimus muscles of line pigs and Real-time ultrasound has also been reported as a reliable method for estimating IMF in live pigs. So we estimate the correlation between meat quality traits and IMF percentage to investigate the possibility of utilizing real-time ultrasound technology for predicting IMF percentage in line pigs to improve pork quality. The genetic and phenotypic correlations for chemical intramuscular fat (CIMF) and ultrasound intramuscular fat (UIMF) were estimated to be 0.75 and 0.76, respectively. These results suggest that genetic factors strongly influence meat quality. The genetic and phenotypic correlation between UIMF and CIMF were 0.75, 0.76, respectively. The heritability of UIMF and CIMF were 0.48 and 0.50, respectively. So we concluded that CIMF can be replaced with UIMF and Ultrasound machines can be used to test IMF in live swine. In future, UIMF can be utilized to improve pork quality as an alternative to CIMF.

초음파 진단 기기에서의 시간 이득 보상과 다이나믹 범위 조절을 위한 자동 최적화 알고리즘 (Automatic optimization for time gain compensation and dynamic range control in ultrasound diagnostic systems)

  • 이덕운;김용선;나종범
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.399-402
    • /
    • 2005
  • For efficient and accurate diagnosis of ultrasound images, the time gain compensation (TGC) and dynamic range (DR) control of the ultrasound echo signal are important. TGC is for compensating the attenuation of the ultrasound echo signal along the depth, and DR is used to control the image contrast. In this paper, we propose an algorithm for finding the optimized values of TGC and DR automatically. For TGC, the degree of compensation is determined along the depth based on the effective attenuation estimation of ultrasound signal. For DR optimization, we introduce a novel cost function on the basis of the characteristics of ultrasound image, which provides the minimum value at the optimal DR. Experiments have been performed by applying the proposed algorithm to a real US imaging system. The results show that the algorithm automatically can determine the values of TGC and DR in realtime so that the subjective quality of the corresponding US image may be good enough for diagnosis.

  • PDF

효율적인 혈류 속도 측정을 위한 연속 초음파 도플러 장치의 구현 (An implementation of the continuous wave doppler system for blood flow measurement using the ultrasound)

  • 박형재;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.516-519
    • /
    • 2001
  • 환자를 진단하는데 있어 중풍, 고혈압, 동맥경화, 고지혈증 등 혈관 질환에 대해서 혈류에 관한 정보는 매우 중요하다. 초음파를 이용하여 혈류 속도를 측정하는 방법에는 연속 도플러 시스템과 펄스 도플러 시스템으로 나뉘어진다. 펄스 도플러 시스템은 혈류의 위치정보를 얻을 수 있지만, 연속 도플러 시스템에 비해 하드웨어적으로 복잡하고 신호대 잡음비가 낮으므로 본 연구에서는 신뢰적인 정보를 얻을 수 있는 연속 도플러 시스템을 이용하였다. 본 시스템은 크게 아날로그 부와 디지털 부로 나뉘어진다. 아날로그 부는 초음파 신호의 발생부, 초음파 센서로 수신된 신호를 증폭하는 증폭부와 혈류의 도플러 신호를 검출하는 복조부, 잡음 제거를 위한 필터부분으로 구성되어 있다. 디지털 부는 검출된 아날로그 신호를 디지털 신호로 변환하는 부분, 디지털 신호처리 부분 그리고 개인용 컴퓨터(Personal Computer)와 통신하는 부분으로 구성된다. 본 연구에서는 효율적인 초음파 혈류 속도 측정 시스템을 구현함으로써 환자의 혈류 정보를 실시간으로 인을 수 있으므로 뇌혈류 측정 등에 사용되는 전산화 단층 환영장치(Computered Tomography), 자기 공명 영상 촬영장치(Magnetic Resonance Imaging)와 같은 장비와 더불어 보다 정확한 진단을 하는데 유용하다.

  • PDF

실시간 초음파 영상에서 노이즈 개선을 위한 GPU 기반의 필터 알고리즘 (A GPU-based Filter Algorithm for Noise Improvement in Realtime Ultrasound Images)

  • 조영복;우성희
    • 디지털콘텐츠학회 논문지
    • /
    • 제19권6호
    • /
    • pp.1207-1212
    • /
    • 2018
  • 초음파 영상은 초음파 펄스를 이용해 반사파를 수신하여 진단에 필요한 영상을 구성하는데 신호가 약해 질 경우, 잡음이 발생하여 미세한 명암도 차이가 발생한다. 또한 초음파 영상의 특성인 호흡에 의한 흔들림 현상과 실시간으로 변화하는 움직임에서 영상의 밝기 변화가 발생한다. 이와 같은 노이즈로 인해 임상적 병변을 육안으로 판단하고 진단하는데 어려움이 있다. 본 논문에서는 초음파 획득한 이미지에 영상처리 기법을 이용하여 형태학적 특징을 자동 추출한다. 이 논문에서는 영상처리를 위해 클라우드 빅데이터 처리 플랫폼을 활용해 GPU기반의 빠른 필터를 구현하였다. GPU 기반의 고성능 필터의 적용시 CPU 기반보다 4.7배 빠른 성능으로 알고리즘이 동작되었고 PSNR이 37.2dB로 원본과 매우 유사함을 확인하였다.

DEFECT DETECTION WITHIN A PIPE USING ULTRASOUND EXCITED THERMOGRAPHY

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제39권5호
    • /
    • pp.637-646
    • /
    • 2007
  • An UET (ultrasound excited thermography) has been used for several years for a remote non-destructive testing in the automotive and aircraft industry. It provides a thermo sonic image for a defect detection. A thermograhy is based On a propagation and a reflection of a thermal wave, which is launched from the surface into the inspected sample by an absorption of a modulated radiation. For an energy deposition to a sample, the UET uses an ultrasound excited vibration energy as an internal heat source. In this paper the applicability of the UET for a realtime defect detection is described. Measurements were performed on two kinds of pipes made from a copper and a CFRP material. In the interior of the CFRP pipe (70mm diameter), a groove (width - 6mm, depth - 2.7mm, and length - 70mm) was engraved by a milling. In the case of the copper pipe, a defect was made with a groove (width - 2mm, depth - 1mm, and length - 110 mm) by the same method. An ultrasonic vibration energy of a pulsed type is injected into the exterior side of the pipe. A hot spot, which is a small area around the defect was considerably heated up when compared to the other intact areas, was observed. A test On a damaged copper pipe produced a thermo sonic image, which was an excellent image contrast when compared to a CFRP pipe. Test on a CFRP pipe with a subsurface defect revealed a thermo sonic image at the groove position which was a relatively weak contrast.

송아지 난소에서 초음파 유도에 의한 한우의 미성숙난자 채취시에 bST-FSH 처리효과에 관한 연구 (Effect of bST Co-Treatment with FSH on Transvaginal Ultrasound-Guided Oocyte Retrieval(TVR) in Calves)

  • 이병천;이강남;김남렬;황우석
    • 한국수정란이식학회지
    • /
    • 제11권2호
    • /
    • pp.103-109
    • /
    • 1996
  • The aim of this study was to evaluate the effect of recombinant bovine somatotropin (bST; Boostin-S, LG Chem) treatment with FSH (Super OV) or PMSG on superovulatory response for transvaginal ultrasound-guided oocyte retrieval (TVR) in calves. Eight Korean Native Cattle(KNC) heifer calves; 150 to 240 days old; were randomly assigned to four treatment groups: 1) FSH(75 mg); 2) FSH (75 mg) + bST(500mg) 3) PMSG(1;000 IU); 4) PMSG(1, 000 IU) + bST(500 mg). Experimental calves in group 1 (n=2) and 2(n=2) were weekly superovulated for 4 consecutive weeks with daily injection of FSH for 3days and the next day subjected to TVR session. Animals in group 3 (n=2) and 4(n=2) were weekly stimulated for 4 consecutive weeks with a single dose of 1, 000 IU PMSG. TVR was performed on 72 hours after PMSG injection. Calves in group 2 and 4 was received injection of 500 mg of bST every 10 days. At each TVR session, follicle number and size were recorded; the oocytes collected and graded according to cumulus and cytoplasm investment. Collected oocyte were determined viable oocyte according to morphological quality with granulation of oocyte and number and status of cumlulus cells. IVM and IVF were performed and assessed cleavage rate on day 3 after fertilization. A Sonovet 600(Medison, Co., Ltd) realtime ultrasound scanner with a 6.5 MHz convex transducer, fixed at the tip of 500 mm estended handle equipped with a needle guide was used in collecting oocyte. Differences between groups were analysed by chi-square test. The population of large follicle ($\geq$5 nun) and aspiration rate were not significant different among the 4 groups. But, the number of small follicles (<5 mm) and aspirated oocyte in the KNC calves treated with bST were 1.3~1.6 times higher than in KNC calves treat with FSH or PMSG alone. In conclusion, the administration of bST with FSH or PMSG at superovulation for TVR in calves was increase the nurnber of small follicle which was influenced the number of aspiratable follicle.

  • PDF

RSSI 판독 라이브러리 함수 및 옥내 측위 모듈 구현 (Implementation of a Library Function of Scanning RSSI and Indoor Positioning Modules)

  • 임재걸;정승환;심규박
    • 한국멀티미디어학회논문지
    • /
    • 제10권11호
    • /
    • pp.1483-1495
    • /
    • 2007
  • IEEE 802.11 기술 덕분에 학교와 대형 쇼핑몰을 비롯한 사무실, 병원, 역 등지에서도 무선 LAN을 통한 인터넷 접속이 가능하다. 본 논문은 무선 LAN에 현재 가장 많이 사용되는 2.4GHz 대역의 802.11b와 802.11g 프로토콜이 탑재된 액세스포인트(AP: Access Point)로부터 수신한 신호의 세기(RSSI: Received Signal Strength Indicator)를 판독할 수 있는 C# 라이브러리 함수를 제안한다. 위치기반서비스는 사용자의 현재 위치를 실시간으로 측정하여 현재 위치를 기반으로 길을 안내하거나, 현재 위치와 관련한 콘텐츠를 제공하는 등의 유용한 서비스를 제공한다. 옥내에서 위치기반서비스를 제공하려면 옥내에 있는 사용자의 위치를 판정하는 옥내측위가 반드시 선결되어야 한다. 옥내측위 기술로 적외선, 초음파, UDP 패킷의 신호세기 등을 이용하는 방법들이 소개된 바 있다. 이러한 방법들은 측위를 위한 특수 장비를 설비해야만 한다는 단점이 있다. 본 논문은 RSSI를 판독하는 라이브러리 함수를 제공할 뿐만 아니라 제공하는 함수를 이용한 옥내 측위 구현 예도 소개한다. 구현에 적용된 방법들은 이미 널리 알려진 K-NN(K Nearest Neighbors), 베이시안 방법 그리고 삼각측량법이다. K-NN 방법과 베이시안 방법은 일종의 지문방식인데, 지문방식은 준비단계와 실시간단계로 구성되며, 실시간 단계의 처리 과정은 처리속도가 빨라야만 한다. 본 논문은 실시간 단계의 속도를 개선하는 방법으로 판단나무 방법(Decision Tree Method)을 제안하고, 이러한 방법들의 성능을 실험적으로 평가한 결과를 소개한다.

  • PDF

초음파 열 영상 검사를 이용한 브레이징 접합 결함 검출 (A Brazing Defect Detection Using an Ultrasonic Infrared Imaging Inspection)

  • 조재완;최영수;정승호;정현규
    • 비파괴검사학회지
    • /
    • 제27권5호
    • /
    • pp.426-431
    • /
    • 2007
  • 고에너지 초음파 여기 탄성파가 물체의 균열, 박리 등의 결함 부위를 통과할 때 서로 맞닿은 결함면은 균일하게 진동하지 않는다. 초음파 입사에 따른 결함 면 사이의 마찰(friction), 문지름 (rubbing) 또는 부딪침(clapping) 에 의해 진동 에너지가 결함 부위에서 국부적인 열로 변환된다. 이를 적외선 열 영상 카메라로 관측하면 구조물의 결함을 실시간으로 검출할 수 있다. 본 논문에서는 초음파 열 영상 검사를 이용한 인코넬 합금 박판의 브레이징 접합 결함 검출에 대해 기술한다. 2 kW 의 전력과 23 kHz 대역의 가진 주파수를 갖는 초음파 펄스를 280 ms 기간 동안 인코넬 합금의 브레이징 접합 박판에 입사시켰다. 브레이징 접합부의 결함위치 부근의 인코넬 합금 박판의 양면이 맞닿은 경계선에서 아주 밝은 국부적인 발열(핫 스팟)이 적외선 열 영상 카메라에 의해 관측되었으며 브레이징 접합 결함 위치에서도 미약한 열이 관측되었다. 배경 감산 평균 및 히스토그램 평활화 처리 등의 영상처리를 통해 브레이징 접합의 결함을 확인하였다.

초음파를 이용한 고체추진제 연소속도의 측정원리 및 시범시스템 개발 (The principle and a prototype system for burning rate measurement of solid propellants using ultrasound)

  • 송성진;전진홍;김학준;김인철;류백능;유지창;정정용
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.259-265
    • /
    • 2005
  • 초음파법를 이용하여 고체추진제 연소속도를 측정하기 위해 특별한 연소챔버와 초음파-압력측정시스템을 설계하고 제작하였다. 그리고 추진제에 대한 가압실험과 연소실험 중에 이 시스템을 이용해 초음파와 압력신호를 획득했다. 획득한 신호를 바탕으로 압력에 따른 연소속도를 측정할 수 있는 연소속도 해석프로그램을 개발하였다. 연소속도 측정프로그램은 압력에 따른 추진제의 음속의 변화를 보정한 것과 추진제와 고체커플런트의 음속변화를 보정한 것 두가지 알고리즘을 이용하였다. 그리고 각 알고리즘에 대한 연소속도 측정정밀도가 스트랜드버너법으로 측정된 연소속도와 비교하여 계산되었다.

  • PDF