• Title/Summary/Keyword: Real-time Ultrasound

Search Result 188, Processing Time 0.025 seconds

Display of Irradiation Location of Ultrasonic Beauty Device Using AR Scheme (증강현실 기법을 이용한 초음파 미용기의 조사 위치 표시)

  • Kang, Moon-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.25-31
    • /
    • 2020
  • In this study, for the safe use of a portable ultrasonic skin-beauty device, an android app was developed to show the irradiation locations of focused ultrasound to a user through augmented reality (AR) and enable stable self-surgery. The utility of the app was assessed through testing. While the user is making a facial treatment with the beauty device, the user's face and the ultrasonic irradiation location on the face are detected in real-time with a smart-phone camera. The irradiation location is then indicated on the face image and shown to the user so that excessive ultrasound is not irradiated to the same area during treatment. To this end, ML-Kit is used to detect the user's face landmarks in real-time, and they are compared with a reference face model to estimate the pose of the face, such as rotation and movement. After mounting a LED on the ultrasonic irradiation part of the device and operating the LED during irradiation, the LED light was searched to find the position of the ultrasonic irradiation on the smart-phone screen, and the irradiation position was registered and displayed on the face image based on the estimated face pose. Each task performed in the app was implemented through the thread and the timer, and all tasks were executed within 75 ms. The test results showed that the time taken to register and display 120 ultrasound irradiation positions was less than 25ms, and the display accuracy was within 20mm when the face did not rotate significantly.

Development of Ultrasound B-scanner(I)-System and Analog Part- (초음파 B스캔너의 개발(I) -시스템 및 아나로그부분-)

  • 김진하;신동희
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.77-84
    • /
    • 1984
  • A prototype of a linear real-time ultrasound B-scanner has been developed which has an axial resolution of 1-2mm and lateral resolution of 2-3mm. In the actual hardware and software implementations of the B-scanner, the following features were emphasized; (1) a dynamic focusing to improve resolution; (2) signal processing to obtain low noise image; (3) various functions for the user's convenience' (4) simplification of the system by an extensive use of recently developed LSI's; (5) development of a prototype at the level of a commercial product. This paper reports the experimental results of the overall system and the design approach of the analog part. The work on the digital part of the B-scanner is reported in part (II) seperately.

  • PDF

Diagnosis of Nonmigrating Metallic Foreign Bodies in the Abdomen Using Ultrasound: An Alternative Approach Using a Traditional Method

  • Pak, Seong Min;Lee, Yeoun Joo;Hwang, Jae Yeon
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.1
    • /
    • pp.87-91
    • /
    • 2022
  • Ingestion of foreign bodies (FBs) is a common phenomenon among young children. Plain radiography is the first step diagnostic modality to detect the radio-opaque FBs. And computed tomography has been recommended by several guidelines as useful modalities for diagnosing ingested FBs. However, there is a risk of radiation exposure, making it burdensome to use in asymptomatic patients. Ultrasound (US) is not a commonly used technique for diagnosing ingested foreign bodies. However, US can provide real-time imaging with good resolutions without radiation exposure in pediatric patients. Herein, we report two pediatric cases of metallic foreign body ingestion that were successfully diagnosed using US for localizing foreign bodies. This study indicates that US may be used as an alternative method for detecting the localization of metallic foreign bodies in the gastrointestinal tract without exposure of radiation, particularly in pediatric patients.

Implementation of an Ultrasound Elasticity Imaging System

  • Cho Gae-Young;Yoon Ra-Young;Park Jeong-Man;Kwon Sung-Jae;Ahn Young-Bok;Bae Moo-Ho;Jeong Mok-Kun
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.3
    • /
    • pp.117-124
    • /
    • 2006
  • Recently, active research has been going on to measure the elastic modulus of human soft tissue with medical ultrasound imaging systems for the purpose of diagnosing cancers or tumors which have been difficult to detect with conventional B-mode imaging techniques. In this paper, a real-time ultrasonic elasticity imaging system is implemented in software on a Pentium processor-based ultrasonic diagnostic imaging system. Soft tissue is subjected to external vibration, and the resulting tissue displacements change the phase of received echoes, which is in turn used to estimate tissue elasticity. It was confirmed from experiment with a phantom that the implemented elasticity imaging system could differentiate between soft and hard regions, where the latter is twice harder than the former, while operating at an adequate frame rate of 20 frames/s.

Defect Detection of Ceramic Heating Plate Using Ultrasound Pulse Thermography (초음파 펄스 서모그라피를 이용한 세라믹 전열 판의 결함 검출)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.4 s.287
    • /
    • pp.259-263
    • /
    • 2006
  • The applicability of UPT (Ultrasound Pulse Thermography) for real-time defect detection of the ceramic heating plate is described. The ceramic heating plate with superior insulation and high radiation is used to control the water temperature in underwater environment. The underwater temperature control system can be damaged owing to the short circuit, which resulted from the defect of the ceramic heating plate. A high power ultrasonic energy with pulse duration of 280 ms was injected into the ceramic heating plate in the vertical direction. The ultrasound excited vibration energy sent into the component propagate inside the sample until they were converted to the heat in the vicinity of the defect. Therefore, an injection of the ultrasound pulse wave which results in heat generation, turns the defect into a local thermal wave transmitter. Its local emission is monitored and recorded via the thermal infrared camera at the surface which is processed by image recording system. Measurements were Performed on 4 kinds of samples, composed of 3 intact plates and the defect plate. The observed thermal image revealed two area of crack in the defective ceramic heating plate.

Prolotherapy for the Upper Extremity (상지에서의 증식치료)

  • Shin, Keun Man
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.117-121
    • /
    • 2008
  • Prolotherapy can be defined as the injection of growth factors or growth factor production stimulants to grow normal cells or tissue. Even though it has been a controversal procedure for decades, it is currently gaining in popularity among many physicians. The term prolotherapy was coined by Hacket in the 1950s to imply proliferation of normal tissue at ligamentous and tendinous entheses. The procedure has been described by other terms, such as sclerotherapy, regenerative injection therapy, and stimulated ligament repair. Incomplete healing from sprains or strains is common and can lead to chronic pain, joint instability and laxity, and is a risk factor for the development of osteoarthritis. Prolotherapy is commonly used for these musculoskeletal conditions which are refractory to usual care therapies. The proliferant solution and technique varies according to physicial training and preferance. Commonly reported proliferants include 10% to 25% dextrose, P2G and sodium morrhuate. High resolution ultrasound imaging of musculoskeletal tissue is increasing in popularity because of patient tolerability, low cost, ability to visualize tissue in real time motion and superior resolution of highly organized tissue such as a tendon. This procedure can be introduced by ultrasound imaging and tissue growth and repair after this procedure in a tendon or a ligament can be documented with ultrasound.

  • PDF

Multimodal Imaging of Sarcopenia using Optical Coherence Tomography and Ultrasound in Rat Model

  • Jeon, Byeong Hwan;Chae, Yu-Gyeong;Hwang, Sang Seok;Kim, Dong Kyu;Oak, Chulho;Park, Eun-Kee;Ahn, Yeh-Chan
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.55-59
    • /
    • 2014
  • Sarcopenia, or reduced muscle mass and volume, is due to various factors such as senile change, neuronal degeneration, drug, malignancy, and sepsis. Sarcopenia with the aging process has been evidenced by the decline in muscle mass by 0.5 to 1% per year with 3-5% reduction in muscle strength for 10 years between the ages of 40 and 50, and a 1-2% of decline of mass every year in people aged 60-70. Therefore, early diagnosis and understanding the mechanism of sarcopenia are crucial in the prevention of muscle loss. However, it is still difficult to image changes of muscle microstructure due to a lack of techniques. In this study, we developed an animal model using denervated rats to induce a rapid atrophy in the tibialis anterior (TA) and imaged its structural changes using optical coherence tomography (OCT) along with histologic and ultrasound analyses. Ultrasound showed changes of overall muscle size. Histology revealed that the atrophic TA muscle displayed an increased size variability of muscle fiber and inflammatory changes. Three dimensional OCT imaged the changes of perimysial grid and muscle fiber structure in real time without sacrifice. These observed advantages of multimodal imaging using OCT and ultrasound would provide clinical benefits in the diagnosis of sarcopenia.

Adaptive quantization for effective data-rate reduction in ultrafast ultrasound imaging (초고속 초음파 영상의 효과적인 데이터율 저감을 위한 적응 양자화)

  • Doyoung Jang;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.422-428
    • /
    • 2023
  • Ultrafast ultrasound imaging has been applied to various imaging approaches, including shear wave elastography, ultrafast Doppler, and super-resolution imaging. However, these methods are still challenging in real-time implementation for three Dimension (3D) or portable applications because of their massive data rate required. In this paper, we proposed an adaptive quantization method that effectively reduces the data rate of large Radio Frequency (RF) data. In soft tissue, ultrasound backscatter signals require a high dynamic range, and thus typical quantization used in the current systems uses the quantization level of 10 bits to 14 bits. To alleviate the quantization level to expand the application of ultrafast ultrasound imaging, this study proposed a depth-sectional quantization approach that reduces the quantization errors. For quantitative evaluation, Field II simulations, phantom experiments, and in vivo imaging were conducted and CNR, spatial resolution, and SSIM values were compared with the proposed method and fixed quantization method. We demonstrated that our proposed method is capable of effectively reducing the quantization level down to 3-bit while minimizing the image quality degradation.

Feasibility of Ultrasound-Guided Lumbar and S1 Nerve Root Block: A Cadaver Study (초음파 유도하 요추 및 제1천추 신경근 차단술의 타당성 연구)

  • Kim, Jaewon;Park, Hye Jung;Lee, Won Ihl;Won, Sun Jae
    • Clinical Pain
    • /
    • v.18 no.2
    • /
    • pp.59-64
    • /
    • 2019
  • Objective: This study evaluated the feasibility of ultrasound-guided lumbar nerve root block (LNRB) and S1 nerve root block by identifying spread patterns via fluoroscopy in cadavers. Method: A total of 48 ultrasound-guided injections were performed in 4 fresh cadavers from L1 to S1 roots. The target point of LNRB was the midpoint between the lower border of the transverse process and the facet joint at each level. The target point of S1 nerve root block was the S1 foramen, which can be visualized between the median sacral crest and the posterior superior iliac spine, below the L5-S1 facet joint. The injection was performed via an in-plane approach under real-time axial view ultrasound guidance. Fluoroscopic validation was performed after the injection of 2 cc of contrast agent. Results: The needle placements were correct in all injections. Fluoroscopy confirmed an intra-foraminal contrast spreading pattern following 41 of the 48 injections (85.4%). The other 7 injections (14.6%) yielded typical neurograms, but also resulted in extra-foraminal patterns that occurred evenly in each nerve root, including S1. Conclusion: Ultrasound-guided injection may be an option for the delivery of injectate into the S1 nerve root, as well as lumbar nerve root area.

Real-Time 3-D Ultrasound Imaging Method using a 2-D Curved Array (이차원 곡면 어레이를 이용한 실시간 3차원 초음파 영상화 기법)

  • 김강식;한호산;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.351-364
    • /
    • 2002
  • Conventional 3D ultrasound imaging using mechanical ID arrays suffers from poor elevation resolution due to the limited depth-of-focus (DOF). On the other hand, 3D imaging systems using 2D phased arrays have a large number of active channels and hence require a very expensive and bulky beamforming hardware. To overcome these limitations, a new real-time volumetric imaging method using curved 2-D arrays is presented, in which a small subaperture, consisting of 256 elements, moves across the array surface to scan a volume of interest. For this purpose, a 2-D curved array is designed which consists of 90$\times$46 elements with 1.5λ inter-element spacing and has the same view angles along both the lateral and elevation directions as those of a commercial mechanical 1-D array. In the proposed method, transmit and receive subapertures are constructed by cutting the four corners of a rectangular aperture to obtain a required image qualify with a small number of active channels. In addition the receive subaperture size is increased by using a sparse array scheme that uses every other elements in both directions. To suppress the grating lobes elevated due to the increase in clement spacing, fold-over array scheme is adopted in transmit, which doubles the effective size of a transmit aperture in each direction. Computer simulation results show that the proposed method can provide almost the same and greatly improved resolutions in the lateral and elevation directions, respectively compared with the conventional 3D imaging with a mechanical 1-D array.