• 제목/요약/키워드: Real-time Ultrasound

검색결과 188건 처리시간 0.029초

Stiffness of the Central Corpus Cavernosum on Shear-Wave Elastography Is Inversely Correlated with the Penile Rigidity Score in Patients with Erectile Dysfunction

  • Joo Yong Lee;Dae Chul Jung;Seungsoo Lee;Nam Gyu Kang;Young Taik Oh;Kyunghwa Han
    • The World Journal of Men's Health
    • /
    • 제39권1호
    • /
    • pp.123-130
    • /
    • 2021
  • Purpose: To perform real-time quantitative measurements of penile rigidity for patients with erectile dysfunction (ED) using shear-wave elastography (SWE). Materials and Methods: A total of 92 patients with clinically diagnosed ED filled out an abridged five-item version of the International Index of Erectile Function (IIEF-5) questionnaire and underwent SWE as well as penile color Doppler ultrasound (CDUS) after intracavernosal injection for penile erection. Elasticity measurements were repeated on two sites of the corpus cavernosum (central and peripheral elasticity of corpus cavernosum [ECC]) and the glans penis during the erection phase. Correlations between penile elasticity and rigidity scores or IIEF-5 were evaluated statistically. Penile elasticity was also compared with the ED types based on CDUS. Results: The mean age of all patients was 53.5±13.4 years, and the mean IIEF-5 score was 9.78±5.01. The rigidity score and central ECC value demonstrated a significant correlation (r=-0.272; 95% confidence interval: -0.464 to -0.056; p=0.015). The IIEF-5 score was not significantly correlated with penile elasticity. Vascular ED patients showed significantly higher central ECC values than nonvascular ED patients (p<0.001). At a cut-off value of 8.05 kPa, the central ECC had a specificity of 41.5%, a sensitivity of 84.6%, and an area under the ROC curve of 0.720 with a standard error of 0.059 (p=0.019) for predicting vascular ED. Conclusions: Quantitatively measuring Young's modulus of the corpus cavernosum using SWE could be an objective technique for assessing penile erectile rigidity and the vascular subtype in patients with ED.

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.122-125
    • /
    • 2004
  • 폐, 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range 3 cm${\sim}$3 m), Computer(RS232C), Servo Motor (Torque 2.3 Kg)등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램 하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터 간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터 간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}$1% 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 2.34 ${\times}$ 10-4 초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정 간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정 간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}$1%이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34 ${\times}$ 10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.

  • PDF

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • Radiation Oncology Journal
    • /
    • 제22권4호
    • /
    • pp.316-324
    • /
    • 2004
  • 목적 : 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사 체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 대상 및 방법 : 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range $3\~3$ m), Computer (RS232C), Sewo Motor (Torque 2.3 Kg) 등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 결과 : 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}1\%$ 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 $2.34{times}10^{-4}$초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 결론 : 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}1\%$ 이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34H10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.

위상배열 초음파기법을 이용한 강구조물의 비파괴 탐상 (Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique)

  • 신현재;송성진;장유현
    • 비파괴검사학회지
    • /
    • 제20권6호
    • /
    • pp.538-544
    • /
    • 2000
  • 강구조물의 내부를 영상화 하여 비파괴 평가를 할 수 있는 위상배열 초음파 탐상 시스템을 의료용 영상진단기를 개조함으로 개발하였다. 선택된 의료용 시스템은 64개의 독립된 송수신채널로 이루어져있으며 최고 128개의 배열초음파 탐촉자를 구동하여 초음파영상을 획득할 수 있도록 되어있다. 개조를 위해 주되게 고려된 사항은 속도의 변화로 인한 시스템의 개조와 강구조물에 적합한 탐촉자의 제작 그리고 비파괴 탐상에서 필요한 A-scan 신호를 획득하는 것이었다. 강구조물에 적합한 배열탐촉자를 설계하고 제작하기위해 경계회절파모델(Boundary Diffraction Wave Model)을 이용하여 초음파의 방사되는 음장을 시뮬레이션 하였다. 그리고 A-scan신호를 획득하기위한 장치를 제작하여 주어진 영상에서 선택된 주사선(scan line)의 RF신호를 획득하도록 하였다. 또한 강구조물에서 적절하게 송수신집속이 될 수 있도록 지연시간을 조절하였다. 개발된 시스템과 제작된 배열 탐촉자의 성능평가를 위해 인위결함 시험편에서 실험한 결과, 시험편의 내부의 영상과 선택한 주사선에 대한 A-scan신호를 실시간으로 획득할 수 있었다.

  • PDF

만성요통환자에서 PNF 기법을 이용한 요부안정화 운동이 요부 심부근 두께 및 기능적 활동에 미치는 효과 (Effects of Lumbar Stabilization Exercise using PNF Techniques on Thickness of Lumbar Deep Muscle and Functional Activity in Chronic Low Back Pain Patients)

  • 김기도;이윤정;최완석;이동우;정대인;김경윤
    • 한국콘텐츠학회논문지
    • /
    • 제12권3호
    • /
    • pp.233-243
    • /
    • 2012
  • 본 연구는 만성요통환자에서 PNF 기법을 이용한 요부안정화 운동이 요부 심부근의 두께 변화와 기능적 활동에 미치는 효과를 알아보고자 하였다. 연구대상은 만성 요통환자 30명을 대상으로 하였으며, 실험군을 세군으로 10명씩 무작위 할당하였다; 실험군I은 일반물리치료군(n=10), 실험군II는 일반 요부안정화운동군(n=10), 실험군III은 PNF 기법을 이용한 요부안정화운동군(n=10)으로 나누었다. VAS를 사용하여 통증 변화를 측정하였고, 초음파 장비를 사용하여 4주간의 각 운동에 따른 요부 심부근들(복횡근, 외복사근, 다열근)의 근 두께 변화를 알아보았고, ODQ, RMDQ를 사용하여 기능적 활동 수준 변화를 알아보았다. 그 결과, 실험 전 후에 실험군II와 실험군III의 비교에서 VAS와 근 두께의 변화에 유의한 차이를 보였으며, 각 실험군 간의 유의성 검정 결과, 실험군III에서 다른 군들에 비해 유의한 차이를 나타냈다. ODQ, RMDQ 검사 결과에서는 실험 전 후에 실험군II와 실험군III의 비교에서 유의한 차이를 보였으며, 각 실험군 간의 유의성 검정 결과, 실험군III에서 다른 군들에 비해 유의한 차이를 나타냈다. 이상의 결과로 보아, PNF 기법을 이용한 요부 안정화운동은 일반 요부안정화운동에 비해 통증경감 및 요부에 위치한 심부근들의 두께 향상에 더 효과적임을 알 수 있었으며, 이러한 결과는 기능적 활동수준에도 긍정적인 영향을 미치는 것을 확인할 수 있었다.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가 (Reproducibiity of setup error for prostate cancer by ultrasound image-guided radiation therapy)

  • 박성용;임승규;시명근;이지해;김종열;조은주
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.75-81
    • /
    • 2017
  • 목 적: 전립선암 환자에 대한 비침습적이고 피폭선량에 대한 부담이 없는 초음파를 이용한 영상유도방사선치료의 Setup 오차 분석을 통해 치료의 재현성을 평가해 보고자 한다. 대상 및 방법: 치료가 종료된 전립선암 환자 26명의 1,105영상에 대하여 앞-뒤(anterior-posterior, AP), 좌-우(right-left, RL), 위-아래(superior-inferior, SI) 방향의 Setup 오차에 대해 평균, 표준편차와 3D-error을 분석하였다. 또한 오차범위 0-1 mm, 1-3 mm, 3-5 mm, 5 mm 이상에 대한 각 오차 빈도수(frequency, %) 분석을 통하여 AP, RL, SI 방향에 대한 방향성을 확인 하였다. 결 과: Setup 오차는 AP, RL, SI 방향에 대하여 평균과 표준편차는 $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$, $2.01{\pm}1.40mm$였다. 3D-error는 평균 $3.63{\pm}1.63mm$였다. 각 방향에 대한 Setup 오차값의 빈도(frequency, %)는 AP 방향에 대한 오차범위 0-1 mm에서 29 %, 1-3 mm에서 50.2 %, 3-5 mm에서 19.6 %, 5 mm 이상에서 1.3 %였다. RL 방향에 대하여 오차범위 0-1 mm에서 31.3 %, 1-3 mm에서는 52.5 %, 3-5 mm에서는 15.8 %, 5 mm 이상에서 0.5 %였다. 마지막으로 SI 방향에 대한 오차범위 0-1 mm에서 26.3 %, 1-3 mm에서 50.2 %, 3-5 mm에서 22.4 %, 5 mm 이상에서 1.1 %였다. 결 론: Setup error는 SI 방향에서 $2.01{\pm}1.40mm$로 가장 컸으며 오차 빈도는 모든 방향에서 50 % 이상 오차 범위 1-3 mm에 들어온 것으로 확인되었다. $Clarity^{TM}$ Auto scan을 이용한 초음파영상유도 방사선치료는 치료 전에 방광의 전처치 상태, target의 구조 등을 관찰이 가능하고, 치료 중 target의 움직임을 실시간으로 monitoring하여 빠른 repositioning이 가능하다. 결과적으로 초음파를 이용한 실시간 영상유도방사선치료는 치료의 재현성을 높일 수 있을 것으로 사료된다.

  • PDF

펄스 초음파를 이용한 수목 공동부 3D 구현 프로그램 제작 (Development of 3D Viewer for Tree Cavity using Pulse Ultrasound)

  • 손정민;강성훈;문종욱;윤석규;박지군
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.265-271
    • /
    • 2021
  • 수목의 내부 부후의 양상은 많은 원인에 의존한다. 이런 다양한 부후의 원인은 일반적인 방법으로는 탐지가 어렵기 때문에 장기간 부후 상태를 확인할 수 없다면 부후 부위의 확대로 인해 수목의 심각한 피해가 발생할 수 있다. 수목 단층 영상을 획득하는 방식은 센서를 고무망치로 두드려 수목을 통과하는 임펄스가 생성되어 이동하는 속도를 기록한다. 본 논문에서는 물리적 손상에 의한 균열, 공동, 부후를 측정할 수 있도록 Arbotom에서 획득한 수목 단면 영상을 이용하여 수목의 내부 상태를 알 수 있는 3D 뷰어를 개발하여 수목 내부의 부후가 진행된 정도를 파악하고 이를 바탕으로 수목의 외과적 수술이 필요한 경우 참고할 수 있는 데이터를 제시하고자 하였다. 수목의 단층 영상을 획득하기 위해 세 그루의 양버즘 나무와 단풍 나무에 6개의 센서를 부착하여 1m 길이의 나무를 Arbotom 프로그램을 이용하여 측정하였으며 MATLAB을 이용하여 제작한 3D Viewer를 통하여 3D 영상을 구현하였다. 단순히 영상의 획득 뿐만 아니라 수목의 단면 길이와 부피를 측정하였으며 실제로 제작한 3D Viewer에서 단풍 나무의 부후가 발생된 부분 길이는 33.12 cm, 양버즘 나무의 부후는 21.41 cm로 측정되었으며 단풍 나무의 부후의 부피는 78.832 ㎤로 측정되었다. Arbotom의 단면 영상과 3D 영상을 비교한 결과 수목의 실제 양상과 같은 결과를 획득하였기 때문에 제작된 소프트웨어 신뢰성 또한 확보된 것으로 판단할 수 있으며 제작된 Viewer를 통하여 외과적 수목 수술에 적용할 데이터를 제공해 수목의 피해를 최소화 할 것으로 사료된다.