• Title/Summary/Keyword: Real Time Scan Detector

Search Result 13, Processing Time 0.019 seconds

A RTSD Mechanism for Detection of DoS Attack on TCP Network (TCP 네트워크에서 서비스거부공격의 탐지를 위한 RTSD 메커니즘)

  • 이세열;김용수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.05a
    • /
    • pp.252-255
    • /
    • 2002
  • As more critical services are provided in the internet, the risk to these services from malicious users increases. Several networks have experienced problems like Denial of Service(DoS) attacks recently. We analyse a network-based denial of service attack, which is called SYM flooding, to TCP-based networks. It occurs by an attacker who sends TCP connection requests with spoofed source address to a target system. Each request causes the targeted system to send instantly data packets out of a limited pool of resources. Then the target system's resources are exhausted and incoming TCP port connections can not be established. The paper is concerned with a detailed analysis of TCP SYN flooding denial of service attack. In this paper, we propose a Real Time Scan Detector(RTSD) mechanism and evaluate it\`s Performance.

  • PDF

Reliable Measurement Selection for The Small Target Detection and Tracking in The IR Scanning Images (적외선 주사 영상에서 소형 표적의 탐지 및 추적을 위한 신뢰성 있는 측정치 선택 기법)

  • Yang, Yu-Kyung;Kim, Sung-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.75-84
    • /
    • 2008
  • A new automatic small target detection and tracking algorithm for the real-time IR surveillance system is presented. The automatic target detection and tracking algorithm of the real-time systems, requires low complexity and robust tracking performance in the cluttered environment. Linear-array and parallel-scan IR systems usually suffer from severe scan noise caused by the detector non-uniformity. After the spatial filtering and thresholding, this scan noise still remains as high amplitude clutter which degrades the target detection rate and tracking performance. In this paper, we propose a new feature which consists of area and validity information of a measurement. By adopting this feature to the measurements selection and track confirmation, we can increase the target detection rate and reduce both the track loss rate and false track rate. From the experimental results, we can validate the feasibility of the proposed method in the noisy IR images.

Design and Implementation of A Scan Detection Management System with real time Incidence Response (실시간 e-mail 대응 침입시도탐지 관리시스템의 설계 및 구현)

  • Park, Su-Jin;Park, Myeong-Chan;Lee, Sae-Sae;Choe, Yong-Rak
    • The KIPS Transactions:PartC
    • /
    • v.9C no.3
    • /
    • pp.359-366
    • /
    • 2002
  • Nowadays, the hacking techniques are developed increasingly with wide use of internet. The recent type of scanning attack is appeared in against with multiple target systems on the large scaled domain rather than single network of an organization. The development of scan detection management system which can detect and analyze scan activities is necessary to prevent effectively those attacking at the central system. The scan detection management system is useful for effective utilization of various detection information that received from scan detection agents. Real time scan detection management system that can do the integrated analysis of high lever more that having suitable construction in environment of large scale network is developed.

Real Time Spectroelectrochemical Experiments with a Multichannel Detector

  • Sun-Il Mho;Sally N. Holer;Bum-Soo Kim;Su-Moon Park
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.9
    • /
    • pp.739-743
    • /
    • 1994
  • A spectroelectrochemical system assembled with a white light source, bifurcated optical fiber, Oriel Multispec spectrograph, and a charge-coupled device (CCD) detector is described. The system is shown to be capable of acquiring a whole spectrum in the spectral range of 290-800 nm in 25 ms or a longer period during electrochemical experiments at reflective working electrodes such as platinum or mercury. The utility of the system in studying electrochemical reactions during the potential scan, galvanostatic electrolysis, or after the potential step is demonstrated.

A Development of Computer Controlled 5 Axis Ultrasonic Testing System (컴퓨터제어식 5축 자동초음파탐상장치의 개발)

  • Kim, Y.S.;Kim, J.G.;Park, J.C.;Kim, N.I.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.2
    • /
    • pp.32-37
    • /
    • 1990
  • A computer controlled 5 axis ultrasonic testing system is developed in order to detect flaws in special parts with complex shape. The various kinds of ultrasonic test can be performed automatically using computer program which was developed by DHI(Daewoo Heavy Industries Ltd.). By use of this computer program, the detector location can be programed and the amplitude signal of echo can be processed digitally. The test results can be plotted graphically on a high resolution display monitor in real time base. The test data can be also saved in magnetic memory devices(HDD or FDD) as well as in the form of hard copy through color printer. The computer software contains c- scan, c+a scan processing programs as well as statistical analysis for test data.

  • PDF

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF

Development of Portable Arrhythmia Moniter Using Microcomputer(I) (마이크로 컴퓨터를 이용한 휴대용 부정맥 모니터의 개발(I)-하드웨어 설계를 중심으로-)

  • 이명호;안재봉
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.169-182
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

Implementation of Real Time Scan Detector System against Attacks of Applying on Port Scanning Techniques (Port Scanning 기법 기반의 공격을 탐지하기 위한 실시간 스캔 탐지 시스템 구현)

  • 송중석;권용진
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04a
    • /
    • pp.380-382
    • /
    • 2003
  • 현재 네트워크 보안 취약점을 자동으로 검색해주는 다양한 도구들이 인터넷에 공개되어 있어 이러한 도구들을 이용한 취약점 정보수집 및 네트워크 검색공격으로 비롯된 해킹사고가 크게 증가하고 있다. 이와 같은 검색 공격에 대한 탐지 시스템은 "False-Positive(실제 공격이 아닌데 공격이라고 탐지)"와 "False-Negative(실제 공격인데 공격이 아니라고 탐지)"를 줄이는 것이 중요하다. 그러나 현재 공개되어 있는 실시간 스캔 탐지 시스템은 오탐율이 높을 분만 아니라 다양한 스캔 기법에 대해서 탐지를 할 수 없는 것이 사실이다. 본 논문에서는 다양한 포트스캐닝 기법기반의 공격에 대해서 탐지 가능하고 오탐율을 최소화한 실시간 스캔 탐지 시스템을 구현한다.실시간 스캔 탐지 시스템을 구현한다.

  • PDF

Development of Radiometric Scanning System for the Evaluation of the Pipeline (배관 검사용 Radiometric Scanning System 제작 및 시험)

  • Kim, Yong-Kyun;Hong, Seok-Boong;Chung, Chong-Eun;Lee, Yoon-Ho;Jung, Yong-Ha;Lee, Jeong-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.474-482
    • /
    • 2002
  • One dimensional Radiometric scanning system was fabricated and tested as a filmless radiographic inspection system, which could be applied to the evaluation of the corrosion and deposits in the pipeline. This system is composed of the single radioactive source of the collimated focusing beam, and single scintillation detector of BGO, and the mechanical scanning system to transport and align the source and detector, and the operating software to automatically control the mechanical scan system. The performance of the system was simulated using GEANT4 software. This system is applied to one specimen having an artificial falw(flat bottom hole) in the pipe and the other specimen with thickness variation. For the inspection by using the radioactive source in the pipeline, it is possible to evaluate the corrosion and deposits in real time and without film.

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF