• Title/Summary/Keyword: Reactor Operating Condition

Search Result 185, Processing Time 0.027 seconds

Effect of the Molar H2O/ and the Molar O2/C Ratio on Long-Term Performance of Diesel Autothermal Reformer for Solid Oxide Fuel Cell (고체산화물 연료전지용 디젤 자열개질기의 장기성능에 미치는 H2O/C와 O2/C 몰 비의 영향)

  • Yoon, Sang-Ho;Kang, In-Yong;Bae, Gyu-Jong;Bae, Joong-Myeon
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.2
    • /
    • pp.110-115
    • /
    • 2007
  • Solid oxide fuel cell(SOFC) has high fuel flexibility due to its high operating temperatures. Hydrocarbonaceous fuels such as diesel has several advantages such as high energy density and established infrastructure for fuel cell applications. However diesel reforming has technical problems like coke formation in a reactor, which results in catastrophic failure of whole system. Performance degradation of diesel autothermal reforming (ATR) leads to increase of undesirable hydrocarbons at reformed gases and subsequently degrades SOFC performance. In this study, we investigate the degradation of SOFC performance(OCV, open circuit voltage) under hydrocarbon(n-Butane) feeds and characteristics of diesel performing under various ratios of reactants($H_2O/C,\;O_2/C$ molar ratios) for improvement of SOFC performance. Especially we achieved relatively high performance of diesel ATR under $H_2O/C=0.8,\;O_2/C=3$ condition.

Effect of Intermittent Plasma Discharge on the Hydrocarbon Selective Catalytic Reduction of Nitrogen Oxides (간헐적 플라즈마 방전이 질소산화물의 탄화수소 선택적 촉매환원에 미치는 영향)

  • Kyeong-Hwan Yoon;Y. S. Mok
    • Applied Chemistry for Engineering
    • /
    • v.34 no.5
    • /
    • pp.507-514
    • /
    • 2023
  • The selective catalytic reduction (SCR) of nitrogen oxides (NOx) was investigated in a catalyst (Ag/γ-Al2O3) packed dielectric barrier discharge plasma reactor. The intermittent generation of plasma in the catalyst bed partially oxidized the hydrocarbon reductant for NOx removal to several aldehydes. Compared to using the catalyst alone, higher NOx conversion was observed with the intermittent generation of plasma due to the formation of highly reductive aldehydes. Under the same operating conditions (temperature: 250 ℃; C/N: 8), the NOx reduction efficiencies were 47.5%, 92%, and 96% for n-heptane, propionaldehyde, and butyraldehyde, respectively, demonstrating the high NOx reduction capability of aldehydes. To determine the optimal condition for intermittent plasma generation, the high voltage on/off cycle was adjusted from 0.5 to 3 min. The NOx reduction performance was compared between continuous and intermittent plasma generation on the same energy density basis. The highest NOx reduction efficiency was achieved at 2-min high voltage on/off intervals. The reason that the intermittent plasma discharge exhibited higher NOx reduction efficiency even at the same energy density, compared to the continuous plasma generation case, is that the intermediate products, such as aldehydes generated from hydrocarbon, were more efficiently utilized for the reduction of nitrogen oxides.

CO2 Methanation Characteristics over Ni Catalyst in a Pressurized Bubbling Fluidized Bed Reactor (가압 기포 유동층 반응기에서의 Ni계 촉매 CO2 메탄화 특성 연구)

  • Son, Seong Hye;Seo, Myung Won;Hwang, Byung Wook;Park, Sung Jin;Kim, Jung Hwan;Lee, Do Yeon;Go, Kang Seok;Jeon, Sang Goo;Yoon, Sung Min;Kim, Yong Ku;Kim, Jae Ho;Ryu, Ho Jeong;Rhee, Young Woo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.871-877
    • /
    • 2018
  • Storing the surplus energy from renewable energy resource is one of the challenges related to intermittent and fluctuating nature of renewable energy electricity production. $CO_2$ methanation is well known reaction that as a renewable energy storage system. $CO_2$ methanation requires a catalyst to be active at relatively low temperatures ($250-500^{\circ}C$) and selectivity towards methane. In this study, the catalytic performance test was conducted using a pressurized bubbling fluidized bed reactor (Diameter: 0.025 m and Height: 0.35 m) with $Ni/{\gamma}-Al_2O_3$ (Ni70%, and ${\gamma}-Al_2O_3$30%) catalyst. The range of the reaction conditions were $H_2/CO_2$ mole ratio range of 4.0-6.0, temperature of $300-420^{\circ}C$, pressure of 1-9 bar, and gas velocity ($U_0/U_{mf}$) of 1-5. As the $H_2/CO_2$ mole ratio, temperature and pressure increased, $CO_2$ conversion increases at the experimental temperature range. However, $CO_2$ conversion decreases with increasing gas velocity due to poor mixing characteristics in the fluidized bed. The maximum $CO_2$ conversion of 99.6% was obtained with the operating condition as follows; $H_2/CO_2$ ratio of 5, temperature of $400^{\circ}C$, pressure of 9 bar, and $U_0/U_{mf}$ of 1.4-3.

Production of Alternative Coagulant Using Waste Activated Alumina and Evaluation of Coagulation Activity (폐촉매 부산물로부터 대체 응집제 제조 및 응집성능 평가)

  • Lee, Sangwon;Moon, Taesup;Kim, Hyosoo;Choi, Myungwon;Lee, Deasun;Park, Sangtae;Kim, Changwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.514-520
    • /
    • 2014
  • In this study, the production potential of alternative coagulant ($Al_2(SO_4)_3$ solution) having the identical coagulation activity with respect to the commercial coagulant was investigated. The raw material of alternative coagulant was a spent catalyst including aluminium (waste activated alumina) generated in the manufacturing process of the polymer. The alternative coagulant was produced through a series of processes: 1) intense heat and grinding, 2) chemical polymerization and substitution with $H_2SO_4$ solution, 3) dissolution and dilution and 4) settling and separation. To determine the optimal operating conditions in the lab-scale autoclave and dissolver, the content of $Al_2O_3$ in alternative coagulant was analyzed according to changes of the purity of sulfuric acid, reaction temperature, injection ratio of sulfuric acid and water in the dissolver. The results showed that the alternative coagulant having the $Al_2O_3$ content of 7~8% was produced under the optimal conditions such as $H_2SO_4$ purity of 50%, reaction temperature of $120^{\circ}C$, injection ratio of $H_2SO_4$ of 5 times and injection ratio of water of 2.3 times in dissolver. In order to evaluate the coagulation activity of the alternative coagulant, the Jar-test was conducted to the effluent in aerobic reactor. As a result, in both cases of Al/P mole of 1.5 and 2.0, the coagulation activity of the alternative coagulant was higher than that of the existing commercial coagulant. When the production costs were compared between the alternative and commercial coagulant through economic analysis, the production cost reduction of about 50% was available in the case of the alternative coagulant. In addition, it was identified that the alternative coagulant could be applied at field wastewater treatment plant without environmental problem through ecological toxicity testing.

Decomposition of odor using atmospheric-pressure plasma (플라즈마를 이용한 악취물질 분해 특성)

  • Kang, Seok-Won;Lee, Jae-Sik;Lee, Kang-San;Lim, Hee-Ah;Kim, Ji-Seong;Lee, Jeong-Dae;Park, Wol-Su;Park, Young-Koo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.708-718
    • /
    • 2020
  • Offensive odor is recognized as a social environmental problem due to its olfactory effects. Ammonia(NH3), hydrogen sulfide(H2S) and benzene(C6H6) are produced from various petrochemical plants, public sewage treatment plants, public livestock wastes, and food waste disposal facilities in large quantities. Therefore efficient decomposition of offensive odor is needed. In this study, the removal efficiency of atmospheric-pressure plasma operating at an ambient condition was investigated by evaluating the concentrations at upflow and downflow between the plasma reactor. The decomposition of offensive odor using plasma is based on the mechanism of photochemical oxidation of offensive odor using free radical and ozone(O3) generated when discharging plasma, which enables the decomposition of offensive odor at ordinary temperature and has the advantage of no secondary pollutants. As a result, all three odor substances were completely decontaminated within 1 minute as soon as discharging the plasma up to 500 W. This result confirms that high concentration odors or mixed odor materials can be reduced using atmospheric-pressure plasma.