• Title/Summary/Keyword: Reactor Operating Condition

Search Result 185, Processing Time 0.035 seconds

Development of Micro Displacement Extensometer for Environmental Fatigue Test in a High Temperature and High Pressure Autoclave (고온고압 환경피로실험 오토클래이브 내부용 미소변위 측정장치 개발)

  • Jeong, Ill-Seok;Ha, Gak-Hyun;Kim, Tae-Ryong;Jeon, Hyun-Ik;Kim, Young-Sin
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.368-371
    • /
    • 2008
  • An extensometer system to measure strain and displacement of cylindrical fatigue specimen in a autoclave of high temperature and high pressure environment has been developed by KEPRI. The extensometer reads the displacement caused by fatigue loads at the target length of the specimen installed inside the autoclave. The performance of the extensometer were tested at 15MPa, $315^{\circ}C$ of a operating pressurized water reactor. Two LVDT's of magnet type were connected to the extensometer and used for converting the fatigue displacement to electronic signal. The device is being used for developing environmental fatigue curve of CF8M cast austenitic stainless steel (CASS) in the test condition of low cycle and low strain. This paper introduces the background and results of the development.

  • PDF

A Study on the Environment Familiar Technology of High Dense Cyanogen Wastewater by Using High Temperature and High Pressure Materiality (고온 고압 유체를 이용한 고농도 시안폐액의 환경친화 기술에 관한 연구)

  • 황상용;이규성
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.3
    • /
    • pp.141-147
    • /
    • 1998
  • Under high temperature and high pressure, cyanogen disinter gration distruction mechanism brought followings results through continuous plug flow reactor system. 1. The temperature was a important reacting factor in cyanogen disintegration. Over $612.8^{\cird}K$ high disintegration rate or 99.99% was shown even under $2000{\;}mg/{\ell}$ cyanogen density. 2. The conditions of cyanogen disintegration was gained through experimenting the supercrietical condition of water in basic. To gain 99.99% disintegration rate under $1000{\;}mg/{\ell}$ early cyanogen density, the pressure showed 52.8 seconds at $523^{\cird}K$ and 84.2 atm and gained $0.56{\;}mg/{\ell}$ operating density. 3. Here is the reaction velocity formula of cyanogen disintegration by hydrolysis: This formula indicates the high possibility of cyanogen disintegration within a short time. And it also implys the potential possibility on treating NBDICOD and the technology in developing the environment cleaning progress as small size automatic controlling equipment.

  • PDF

Numerical Study on Energy and Environmental System : SNCR, Vortex Tube (환경${\cdot}$에너지 시스템에 관한 수치해석적 연구 : SNCR, 보텍스튜브)

  • Jang Dong-Sun;Sin Na-Il;Seo Jae-Dong;Sin Mi-Su;Eom Tae-In;Kim Dong-Chan
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.162-170
    • /
    • 1999
  • Numerical study has been peformed to develop a computer code for the design & optimal operating condition of SNCR(Selective Noncatalytic Reactor) for NOx reduction together with the analysis of the performance of vortex tube. Especially for the SNCR of the scale of industrial boiler, the required mixing and residence time of $NH_3$ solution was successfully tested numerically by the implementation of some baffle setups in a combustor. The introduction of interesting phenomena of vortex tube and similar system is made together with a theoretical hypothesis and simple cold flow simulation for the flow field analysis.

  • PDF

Estimation of Thermal Aging Embrittlement of LWR Primary Pressure Boundary Components

  • Kim, Sunki;Kim, Yongsoo
    • Nuclear Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.609-616
    • /
    • 1998
  • Cast duplex stainless steels are extensively used for primary pressure boundary components. These components are, however, embrittled due to the precipitation of $\alpha$' phase by spinodal decomposition and other processes when exposed to reactor operating temperature for a design lifetime or life extension conditions. This report presents a procedure for estimating the current condition and the residual life of safety-related stainless steel components by using ANL database and correlations. The database of Charpy impact energy suggests that CF-8M grade is the most susceptible to thermal aging and CF-3 grade is the least. Thus, the integrity of CF-8M alleys may be degraded seriously and the degree of deterioration may exceed acceptance limit after several years of service in the nuclear reactors.

  • PDF

Numerical investigation of steady state characteristics and stability of supercritical water natural circulation loop of a heater and cooler arrangements

  • Rai, Santosh Kumar;Kumar, Pardeep;Panwar, Vinay
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3597-3611
    • /
    • 2021
  • The present paper studies the thermal-hydraulic behaviour of the rectangular supercritical natural circulation loop (SCNCL) using numerical model of one dimensional. Then the results of this model is confirmed with experimental and benchmark results. Variations with several geometric parameters like loop diameter, riser length, and heater length and operating conditions like heater inlet enthalpy, pressure, friction factor, and inlet and exit loss coefficient on steady-state performance are investigated for various orientations like HHHC, HHVC, VHVC and VHHC of the heater and cooler. The chances of existing static instability (Ledinegg excursion) has been investigated, which reveals that it can arise only in a low inlet enthalpy condition, far from the suggested various orientations of heater and cooler.

Effect of electrocoagulation on sludge characteristics in EC-MBR (EC-MBR에서 전기응집이 슬러지 특성에 미치는 영향)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.42-49
    • /
    • 2017
  • The application of electro-coagulation has been attempted to control the membrane fouling problem in a MBR (Membrane Bio-Reactor). This study examined the effects of the operating parameters (current density and contact time) of the electro-coagulation process on the change in the characteristics of activated sludge. The current density changed from 2.5 to 12, $24A/m^2$, and the contact time was varied from 0 to 2 and 6 hr, respectively. At a current density of $24A/m^2$ and 6 hr of operation, the MLSS changed from 6,800 to 7,000 mg/L (3% increase), but the MLVSS did not increase significantly. After 6 hr of operation, the soluble COD decreased from 71 to 37 mg/L under the $24A/m^2$ condition, from 113 to 67 mg/L under the $12A/m^2$ condition, and from 84 to 80 mg/L under the $2.5A/m^2$ condition. On the other hand, soluble-TN and -TP concentration showed slight changes. The soluble-EPS and Bound-EPS concentration decreased slightly with increasing current density. The membrane filtration performance of activated sludge before and after electro-coagulation was compared. The filtration resistances after electro-coagulation decreased from 6 to 61 %, particularly as the current density and contact time were increased. This indicates that electro-coagulation can be used to control membrane fouling in the MBR process.

Study on the optimum operation system of Sequencing Batch Reactor (연속 회분식 반응조의 최적 운전시스템에 관한 연구)

  • Eom, Tae Kyu;Ko, Eun Joo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.54-61
    • /
    • 1999
  • SBR process used to evaluate the removal of organics, nitrogen and phosphorus on the basis of a report of research on a precedence at various operation cycle and condition change. Effluent concentration of COD were 50mg/l, 50mg/l, 90mg/l respectively, The removal rates of COD were nearly over 95% at Run 1, 2 and 4. But at Run 3, Effluent concentration of COD was 255.0mg/l, The removal rate of COD was 87% at Run 3. As Oxic/Anoxic rate was fixed and operating cycle of Oxic/Anoxic was changed, the removal rates of T-N were 74.7%, 46.9%, 28.5%, 63.3% respectively at Run 1~4. The case of Run 1 was best result. The removal rates of T-P was appeared in proportion to T-N removal rates and rest of $NO_2-N$. The removal rates of T-P were 51.2%, 35.5%, 41.5%, 51.9% respectively. The removal rates of COD, T-N, T-P were influenced on the change of SBR operation cycle. As organic loading rate was $1.43kgCOD/m^3day$ and C/N ratio was 3.0, operation cycle of Run 1 was best condition of T-N removal rates and T-P removal.

  • PDF

The Effect of HRT and SRT on Treatment Efficiency of Activated Sludge Process for Low Concentration Municipal Sewage (저농도 도시하수 처리를 위한 활성슬러지공정에서 HRT 및 SRT가 처리효율에 미치는 영향)

  • Whang, Gye Dae;Kim, Min Ho;Ko, Sae Bom
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.64-73
    • /
    • 1997
  • Most of the municipal wastewater treatment plants operated in Korea are designed for high concentrations municipal sewage. However, activated sludge process employed by municipal wastewater treatment plant is operated at low organic loading. The objective of this study was to determine optimum operating condition of activated sludge process for treatment of low concentration municipal sewage. Three bench scale activated sludge reactors were operated to investigate the effect of HRT and SRT on the COD and TSS removal efficiency. The average concentration of TSS, SCOD, SBOD and TKN in influent were 118mg/l, 61mg/l, 21mg/l, and 12mg/l, respectively. The activated sludge reactors operated with various HRT and SRT showed about 89-93% TSS removal efficiency. HRT and SRT does not affect the TSS removal efficiency of actvatied sludge process significantly. However, HRT affected the SCOD removal efficiency slightly. As the HRT decreases from 13hours to 3hours, the SCOD removal efficiency decreases from 67% to 56%. The average effluent TCOD concentration of the reactor operated with 3hours of HRT was approximatly 40-45mg/l. Kinetic coefficient yield (Yt) and decay coefficients(Kd) were 0.594-0.954 mgMLVSS/mgCOD and $0.0197-0.0317day^{-1}$, respectively. Low concentration municipal sewage can be treated with 3 hours of HRT without effluent quality deterioration and SRT does not affect the substrate removal efficiency at this operation condition.

  • PDF

The Button effect of CANFLEX Bundle on the Critical Heat Flux and Critical Channel Power

  • Park, Joohwan;Jisu Jun;Hochun Suk;G.R. Dimmick;D.E. Bullock;W. Inch
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.528-533
    • /
    • 1997
  • A CANFLEX(CANdu FLEXible fuelling) 43-element bundle has developed for a CANDU-6 reactor as an alternative of 37-element fuel bundle. The design has two diameter elements (11.5 and 13.5㎜) to reduce maximum element power rating and buttons to enhance the critical heat flux(CHF), compared with the standard 37-element bundle. The freon CHF experiments have performed for two series of CANFLEX bundles with and without buttons with a modelling fluid as refrigerant H-l34a and axial uniform heat flux condition. Evaluating the effects of buttons of CANFLEX bundle on CHF and Critical Channel Power(CCP) with the experimental results, it is shown that the buttons enhance CCP as well as CHF. All the CHF's for both the CANFLEX bundles are occurred at the end of fuel channel with the high dryout quality conditions. The CHF enhancement ratio are increased with increase of dryout quality for all flow conditions and also with increase of mass flux only lot high pressure conditions. It indicates that the button is a useful design lot CANDU operating condition because most CHF flow conditions for CANDU fuel bundle are ranged to high dryout quality conditions.

  • PDF

Characteristics of Microfauna in Biological Treatment of Landfil Leachate with Reactor Including Porous Media (다공성 Media가 조여된 반응조를 이용한 매립지 침출수의 호기성 생물학적 처리시 미소생물상의 특성)

  • 홍성철;박연규
    • Journal of Environmental Science International
    • /
    • v.5 no.1
    • /
    • pp.61-69
    • /
    • 1996
  • The combined wastewater of municipal landfill leachate and municipal sewage was treated using several sets of bench-scale aerated circulating system including porous media. Investigated items in this experiment were the dominant protozoa and metazoa in this system, the variation of microfauna relationship between operating condition and dominant genera. Also considered the factors determining dominant genera and their role. The outcome of this research is as follows; 1. Aspidisca, Vorticella, Truhellophyllum, Lecane, Philodina, Cyclops were mainly appeared prior to combinding leachate, while Trachelocerca, Bodo, Glaucoma were the dominant genera after combinding leachate. 2. As to metazoa, Nematode and Philodina were not influenced by 5oA leachate mixing ratio, meanwhile Crustacea has high sensitivity for increased leachate mixing ratio and it was not appeared in 5% leachate mixing ratio. 3. The appropriate treatability could'nt be expected at the above 10% leachate mixing ratio. Especially, in the condition of 20% leachate mixing ratio, all of the microfauna were affected damage seriously on their existence. Meanwhile hydraulic retention time, substrate loading rate and slut자e production rate didn't give notable influence on increasing the number of microfauna. 4. As to protozoa, saprozoic and holozoic species were appeared commonly and polysaprobic species were dominent. 5. Filamentous organsms were nearly not affected by leachate mixing. It seems that they could live without any trouble at the 10% leachate mixing ratio, if the substrate is sufficient. 6. Diversity of microfauna had a reducing trernd as the sewage was mixed with leachate.

  • PDF