• Title/Summary/Keyword: Reactive System

Search Result 2,081, Processing Time 0.031 seconds

Calculation of Active Power Transfer Capability using Repeated Power Flow Program

  • Ham, Jung-Pil;Kim, Jung-Hoon;Lee, Byung-Ha;Won, Jong-Ryul
    • KIEE International Transactions on Power Engineering
    • /
    • v.12A no.1
    • /
    • pp.15-19
    • /
    • 2002
  • The power transfer capability is determined by the thermal, dynamic stability and voltage limits of the generation and transmission systems. The voltage stability depends on the reactive power limit and it affects the power transfer capability to a great extent. Then, in most load flow analysis, the reactive power limit is assumed as fixed, relatively different from the actual case. This paper proposes a method for determining the power transfer capability from a static voltage stability point of view using the IPLAN which is a high level language used with PSS/E program. The f-V curve for determining the power transfer capability is determined using Repeated Power Flow method. It Is assumed that the loads are constant and the generation powers change according to the merit order. The maximum reactive power limits are considered as varying similarly with the actual case and the effects of the varied maximum reactive power limits to the maximum power transfer capability are analyzed using a 5-bus power system and a 19-bus practical power system.

Research on Voltage Stability Boundary under Different Reactive Power Control Mode of DFIG Wind Power Plant

  • Ma, Rui;Qin, Zeyu;Yang, Wencan;Li, Mo
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1571-1581
    • /
    • 2016
  • A novel method is proposed to construct the voltage stability boundary of power system considering different Reactive Power Control Mode (RPCM) of Doubly-Fed Induction Generator (DFIG) Wind Power Plant (WPP). It can be used for reflecting the static stability status of grid operation with wind power penetration. The analytical derivation work of boundary search method can expound the mechanism and parameters relationship of different WPP RPCMs. In order to improve the load margin and find a practical method to assess the voltage security of power system, the approximate method of constructing voltage stability boundary and the critical points search algorithms under different RPCMs of DFIG WPP are explored, which can provide direct and effective reference data for operators.

Evaluation of dye-ability and harmfulness of the reactive dyes replacing the metallic acid dyes for wool

  • Park, Ji-Yang;Park, Young-Hwan;Kang, Tae-Jin
    • Journal of Fashion Business
    • /
    • v.14 no.3
    • /
    • pp.116-127
    • /
    • 2010
  • Metal acid dyes are usually used to dye wool fabric to achieve high concentrated color and strong color fastness. However, metal acid dyes contain lots of heavy metal. That causes not only environmental pollution but also diseases to human. In this study, wool reactive dyes instead of metal acid dyes for wool, which are environmental friendly, are compared and analyzed in the evaluation system of their harmfulness, containing heavy metals and examined exhaustion rates and dyeing characteristics.

A Study on Local Coordinative Reactive Power Control between STATCOM and Other Reactive Power Controllers for Voltage Stability Improvement at Substation (변전소 전압안정화를 위한 STATCOM과 기존 조상 설비간의 지역 무효전력 협조제어에 관한 연구)

  • Jeong, Ki-Seok;Chang, Byun-Hoon;Lee, Hyun-Chul;Lee, Geun-Joon;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.525-530
    • /
    • 2010
  • Installation of FACTS(Flexible AC Transmission System) device can maximize utilization of existing power facilities and reliability of power system. STATCOM has excellent characteristics in operating cost, maintaining facilities, loss and so on. However, STATCOM has a disadvantage of facility cost over capacity. So it is effective to coordinate STATCOM and existing external bank(capacitor and reactor) and OLTC(On Load Tap Changer). This paper mainly proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC for voltage stability improvement. The proposed coordinative control method is developed for the STATCOM of Mi-gum substation and the simulation results of EMTP/RV model show the effectiveness of the proposed method.

A New Definition of Short-circuit Ratio for Multi-converter HVDC Systems

  • Liu, Dengfeng;Shi, Dongyuan;Li, Yinhong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.1958-1968
    • /
    • 2015
  • In this paper, a new definition of short-circuit ratio concept for multi-converter HVDC systems is proposed. Analysis results of voltage interaction between converters show that the reactive power-voltage characteristic of a converter has a dominant effect on voltage interaction level compared with its active power-voltage characteristic. Such a relation between converter reactive power and voltage interaction level supports taking the former into account in the definition of short-circuit ratio concept for multi-converter systems. The proposed definition is verified by the method of maximum power curve for various system configurations. Furthermore, a formula to calculate transient overvoltage for multi-converter systems is derived based on the proposed definition, and the efficiency of the derived formula is verified.

The Analysis and Evaluation of the Disturbances and Controller Effects to Power System Dynamic Voltage Stability Design and Control (동적전압붕괴에 대한 외란의 영향평가 및 제어기기 적용 효과 분석)

  • Lee, Geun-Jun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.1
    • /
    • pp.6-12
    • /
    • 2000
  • This paper presents various processes of dynamic voltage collapse which is initiated by various power system disturbances, and the impacts of dynamic voltage controllers. According to the analysis results, the composition of induction motors with short time constants affects the voltage collapse strongly. Also, it is proved that the addition of fast acting reactive compensation devices, such as SVC, at high reactive loss sensitivity($$\delta$$Q$$_luss/\delta$$P$$_L$$) buses could be one of the best countermeasure to escape the voltage collapse.

  • PDF

The depositing characteristics of amorphous carbon thin films by a reactive particle beam assisted sputtering process (Sputter 기반의 활성입자빔 증착장비를 이용한 a-C 박막 증착특성)

  • Lee, Tae-Hoon;Shin, You-Chul;Kwon, Kwang-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.123-123
    • /
    • 2008
  • In this work, amorphous carbon thin films were deposited for hard mask applications by a reactive particle beam (RPB) assisted sputtering system at room temperature. The depositing characteristics of the films were investigated as functions of operating parameters such as reflector bias voltage and RF plasma power. It was confirmed that the deposition rate increased with increasing the reflector bias voltage and RF plasma power. By an atomic force microscope (AFM), it was revealed that the surface roughness was also increased. The total stress in films was determined by the use of the substrate curvature and its result will be discussed.

  • PDF

Removal of Gaseous Elemental Mercury Using Reactive Species Produced by Dielectric Barrier Discharge (저온 플라즈마 반응에 의해 생성된 반응활성종을 이용한 원소상 수은의 제거)

  • Jeong, Ju-Young;Jurng, Jong-Soo
    • Journal of Environmental Science International
    • /
    • v.15 no.5
    • /
    • pp.479-484
    • /
    • 2006
  • Removal of elemental mercury $(Hg^0)$ with the reactive species produced from dielectric barrier discharge (DBD) was studied. We investigated the effect of operating parameters such as the applied voltage, residence time, initial concentration and co-existence of other pollutants. The removal of $(Hg^0)$ was significantly promoted by an increase in the applied voltage of the DBD reactor system. It is important to note that at the same input power, the removal efficiency of $(Hg^0)$ was much higher than that of NO gas. These results imply that if the DBD system is used as a NOx treatment facility, it is capable of removing $(Hg^0)$ simultaneously with NOx.

Minimizing Power Transmission Losses by Optimum Control of Reactive Power Flow (무효전력조류의 최적제어에 의한 전력손실 최소화 연구)

  • 김준현;유석구
    • 전기의세계
    • /
    • v.28 no.10
    • /
    • pp.41-47
    • /
    • 1979
  • The paper develops a method of minimizing power transmission losses by optimum control of reactive power flow. In the past, because the optimizing method considers as the first step the minimization of node voltage deviations and as the second step the minimization of transmission losses within the system, the calculating procedure was more complex and difficult to handle. In this paper, a new computing method for real time control on a digital computer is described which aims at a coordinated use of reactive power sources and voltage regulating devices. The power transmission losses are minimized by a gradient method while satisfying the constrained system voltage conditions and sensitivity parameters are the basis of the method.

  • PDF

Effect of Coloration on the Hydrophilicity and Swelling Properties of Poly-HEMA Hydrogels

  • Jang, Jin-Ho;Park, Hwa-Sung;Jeong, Yong-Kyun
    • Textile Coloration and Finishing
    • /
    • v.19 no.2
    • /
    • pp.7-13
    • /
    • 2007
  • Photopolymerization of 2-hydroxyethyl methacrylate(HEMA), in the presence of ethyleneglycol dimethacrylate(EGDMA) and 1-Hydroxycyclohexyl phenyl ketone as crosslinker and photoinitiator, respectively, produced crosslinked poly-HEMA hydrogels. The hydrogels were colored by the exhaustion of vinylsul-phone-type reactive dyes. Good colorfastness to laundering was achieved when colored with C.I. Reactive Black 5. We investigated that the effect of coloration on the hydrophilicity and swelling properties of the films. More hydrophilic gel-surfaces were generated with in increase in coloration and crosslinking. Higher surface energy was observed with higher crosslinking level. The more rapid and higher water swellability of poly-HEMA gels after coloration may be resulted from a more opened gel structure by the easier hydration of the hydrophilic sulphonic acid groups of the reacted dyes in water.