• Title/Summary/Keyword: Reactive Power Control

Search Result 733, Processing Time 0.03 seconds

Compensation of Voltage Variation Using Active Power-Dependent Reactive Power Control with Multiple VRE Systems Connected in a Distribution Line (배전 선로에 연계된 다수대의 변동성 재생에너지 발전 시스템의 출력 유효전력 변동에 따른 무효전력 제어를 이용한 전압 변동 보상)

  • Lee, Sang-Hoon;Kim, Soo-Bin;Song, Seung-Ho
    • Journal of Wind Energy
    • /
    • v.9 no.4
    • /
    • pp.47-56
    • /
    • 2018
  • This paper introduces an active power dependent standard characteristic curve, Q(P) to compensate for voltage variations due to the output of distributed generation. This paper presents an efficient control method of grid-connected inverters by comparing and analyzing voltage variation magnitude and line loss according to the compensation method. Voltage variations are caused not only by active power, but also by the change of reactive power flowing in the line. In particular, the system is in a relatively remote place in a coastal area compared with existing power plants, so it is relatively weak and may not be suitable for voltage control. So, since it is very important to keep the voltage below the normal voltage limit within the specified inverter capacity and to minimize line loss due to the reactive power. we describe the active power dependent standard characteristic curve, Q(P) method and verify the magnitude of voltage variation by simulation. Finally, the characteristics of each control method and line loss are compared and analyzed.

A Study on Computer Control of Voltage-Rective Power Part 1-Development of Computer Control Seheme (전압, 무효전력의 계산기제어에 관한 연구 1)

  • Kil Yeong Song
    • 전기의세계
    • /
    • v.25 no.6
    • /
    • pp.81-88
    • /
    • 1976
  • The present voltage-reactive power control aims at an overall coordination of reactive power sources and voltage regulation devices to keep the bus voltages within their allowable bounds on one hand and to reduce the transmission losses on the other. This paper presents an efficient computer control scheme for the real-time control of system voltage and reactive power on the basis of a simplified linear equation by using the system characteristic constant. Computational algorithm is used for the minimization of bus voltage deviation in the first phase of optimization and for the reduction of transmission losses under the constraint of vlotage settling condition in the second phase. The numerical example for sample practical system is also given. The present study on the computer control scheme will contribute to the automation of power system operation in the near future.

  • PDF

Active/Reactive Compound Compensation in Distribution System

  • Sul, Yong-Tae
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.4
    • /
    • pp.46-52
    • /
    • 1997
  • In this paper th use of compensation based on a combination of active plus reactive power at distribution model system is proposed. The basic voltage-power relationships for the linearized case on an infinite bus are used and the compensation angle is defined based on the voltage magnitude response to small power injection. Compensation is supplied at several locations, and the system is subjected to varying fault scenarios, with its response observed under different system conditions. As number of control issues for a storage-based active/reactive power compensator as a bus voltage regulator are explored to compare the effectiveness of active/reactive again reactive-only compensation.

  • PDF

An Islanding Microgrid Power Sharing Approach Using Adaptive Virtual Impedance control scheme

  • Hoang, Van-Tuan;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.315-316
    • /
    • 2016
  • This paper proposes an enhanced distributed generation (DG) unit with an adaptive virtual impedance control approachin order to address the inaccurate reactive power sharing problems. The proposed method can adaptively regulate the DG unit thanks to the equivalent impedance, andthe effect of the mismatch in feeder impedance is compensatedto share the reactive power accurately.The proposed control strategy can be implemented directly without any requirement of pre-knowledge of the feeder impedances. Simulations are performed to validate the effectiveness of the proposed control approach.

  • PDF

Novel control algorithm for smart PCS with harmonics and reactive power compensation (고조파와 무효전력 보상기능을 가지는 Smart PCS의 새로운 제어 알고리즘)

  • Seo, Hyo-Ryong;Jang, Seong-Jae;Park, Sang-Soo;Kim, Sang-Yong;Kim, Gyeong-Hun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1053_1054
    • /
    • 2009
  • A significant number of renewable energy systems have been connected to the grids as supplement power source. The renewable energy systems require control algorithm to maintain the power-supply reliability and quality. This paper proposes a novel control algorithm for smart Power Conditioning System (PCS) with harmonics and reactive power compensation. The smart PCS is used to feed Photovoltaic (PV) power to utility and compensate harmonics and reactive power at the same time. The experimentation is carried out on the proposed grid-connected PV generation system, and controlled by digital signal processor. The grid-connected PV generation system injects PV energy into the grid and performs as Active Filter (AF) and Static Synchronous Compensator (STATCOM) without additional devices. The experiment results show that the proposed control algorithm is effective for smart PCS with harmonics and reactive power compensation.

  • PDF

A Knowledge Based System for Reactive Power/Voltage control Based on Pattern Recognition and Set of Indices (패텐인식과 인텍스집합을 이용한 무한전력/전압 전문가 시스템)

  • 박영문;김두현
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.8
    • /
    • pp.731-740
    • /
    • 1991
  • This paper presents a knowledge based system to solve reactive power/voltage control problem in a power system. The methods to reduce inference time are proposed in inferring the solution of problem in the knowledge base which consists of heuristic rules and inowledge of experts. A set of indices drawn from the heuristic knowledge on the power system is utilized to make up for the defect of existing knowledge based systems which determine both the location and the amount of reactive power compensation devices. The concept of set of indices developed in this paper makes it possible to infer the amount of reactive power source only since the bus order list representing priority for the location of reactive power compensator to be switched on can be determined in advance. From the fact that there exists a relationship between the system voltage pattern and the reactive power pattern in operation, the pattern recognition technique is introduced to reduce the inference time in solving the severe voltage problem. To demonstrate the usefulness of the proposed knowledge based system, the IEEE 30 bus system is chosen as a sample system. The results of case study are also presented.

Reactive Power P&O Islanding Detection Method using Positive Feedback (Positive Feedback을 이용한 무효전력 P&O 단독운전 검출기법)

  • Lee, Jong-Won;Park, Sung-Youl;Lee, Jae-Yeon;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.410-416
    • /
    • 2022
  • A grid-connected inverter with critical loads uses mode transfer control to supply stable voltage to the load. An islanding detection method should also be used to quickly detect the grid fault and disconnect the inverter from the grid. However using the existing islanding detection method to detect islanding is difficult due to the small fluctuation of the voltage and frequency of the point of common coupling. This study proposes a reactive power P&O islanding detection method by using the positive feedback technique. The proposed method always injects a small variation of reactive power. When a grid fault occurs, the injected reactive power accelerates the reactive power injection reference. As a result, the reactive power reference value and the sensed reactive power become mismatched, and islanding is detected. Reducing the amount of real-time injected reactive power results in high efficiency and power factor. The simulation and experimental results of a 3 kW single-phase inverter are provided to verify the proposed islanding detection method.

New VFT Grid-Connection System Including Reactive Power Compensation (무효전력 보상을 포함하는 새로운 회전형 변압기 계통 연계 시스템)

  • Oh, Jeong-Sik;Park, Tae-Sik;Kim, Sung-Hwan;Kwak, No-Hong;Park, Jang-Hyun
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.143-150
    • /
    • 2019
  • The back-to-back HVDC asynchronous grid interconnect technology has problems of high harmonic generation, high cost, and low scalability. To solve this problem, research on asynchronous grid interconnect technology using VFT is actively being conducted. However, the reactive power due to the inductance component of the VFT is generated, and the problem of additional installation of the reactive power compensating facility is inevitably generated. Therefore, in this paper, we aim to solve the reactive power compensation problem of existing VFT by designing rectifier AC-DC converter, which is an essential element of the asynchronous grid connection system using VFT, to compensate reactive power as well as active power supply. The performance was verified through simulation.

Research on Voltage Stability Boundary under Different Reactive Power Control Mode of DFIG Wind Power Plant

  • Ma, Rui;Qin, Zeyu;Yang, Wencan;Li, Mo
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1571-1581
    • /
    • 2016
  • A novel method is proposed to construct the voltage stability boundary of power system considering different Reactive Power Control Mode (RPCM) of Doubly-Fed Induction Generator (DFIG) Wind Power Plant (WPP). It can be used for reflecting the static stability status of grid operation with wind power penetration. The analytical derivation work of boundary search method can expound the mechanism and parameters relationship of different WPP RPCMs. In order to improve the load margin and find a practical method to assess the voltage security of power system, the approximate method of constructing voltage stability boundary and the critical points search algorithms under different RPCMs of DFIG WPP are explored, which can provide direct and effective reference data for operators.

Practical Applications of Reactive Power and Voltage Planning In Korea Power System (우리나라 계통에서의 무효전력 수급현황 및 전압특성 분석)

  • Lee, Joo-Ho;Jung, Eung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.158-161
    • /
    • 2004
  • This paper presents practical applications of reactive power and voltage planning to obtain voltage stability and operational voltage level for 2005 year summer peak Korea power system. It also describes the new electric facilities, operation criteria, voltage levels, MVAr flows, reactive power reserves in each control area. And reactive compensation devices are installed to maintain established voltage levels and stability margins. This simulation results show the improvement of voltage levels and the increase of reactive margins & interface flow margins. Finally, the paper reports the necessity of dynamic reactive reserves. It can be applied to analysis reactive compensation requirements and P-V & V-Q curves by PSS/E & VSAT.

  • PDF