• Title/Summary/Keyword: Reactive Method

Search Result 1,519, Processing Time 0.03 seconds

The One Bath One Step Dyeing of Cationized Nylon/Viscose Rayon Mixture Fabrics With Acid Dyes and Reactive Dyes (산성염료와 반응성염료에 의한 카티온화 나일론/비스코스레이온 교직물의 1욕1단 염색)

  • Sung, Woo-Kyung
    • Fashion & Textile Research Journal
    • /
    • v.7 no.3
    • /
    • pp.339-345
    • /
    • 2005
  • It is difficult to dye nylon/viscose rayon mixture fabrics by one-bath one-step dyeing method, because acid dyes and reactive dyes require acidic dyebath for adsorption and alkaline dyebath for fixation respectively. In order to overcome the disadvantage of the conventional two bath two step dyeing method of nylon/viscose rayon mixture fabric, it was pretreated with cationizing agent containing chlorohydrine group in aqueous solution of sodium hydroxide. The pretreated nylon/viscose rayon mixture fabrics produced cationized fabrics that could be dyed with acid dyes and reactive dyes under neutral condition. This study was carried out to investigate dyeing possibilities, surface reflectance spectra and color characteristics of cationized nylon/viscose rayon mixture fabrics with acid dyes and reactive dyes in a non-electrolytic and neutral dyebath by one bath one step dyeing method.

A New Algorithm for Optimal Real and Reactive Power Dispatch (최적유효 및 무요전력배분을 위한 신 앨고리즘)

  • Park, Young-Moon;Lee, Kwang-Yon
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.4
    • /
    • pp.145-154
    • /
    • 1983
  • This paper presents a new method for optimal real and reactive power dispatch for the economic operation of a power system. Unlike the usual approach of minimizing the transmission loss, this method minimizes the total production cost not only for the real power optimization problem, but also for the reactive power optimization. The control variables are real power generation of units for real power optimization, and reactive power optimization. The constraints are the operating limits on these control variables and the limits on the bus voltages. Methematical models are developed to represent the sensitivity relationships between dependent and control variables for both real and reactive power optimization modules, and thus eliminate the use of B-coefficients. In order to handle many functional inequality constraints, a modified version of the gradient projection method is developed for optimization procedure, and has shown a remarkable advantage in computation efficiency.

  • PDF

An Immunohistochemical ana Ultrastructural Studies on the Gut Endocrine Cells in the Hedgehog, Erinaceus koreanus (한국산 고슴도치(Erinaceus koreanus)의 장관 내분비세포에 관한 면역조직화학적 및 전자현미경적 연구)

  • Lee, Jae-Hyun
    • Applied Microscopy
    • /
    • v.18 no.2
    • /
    • pp.59-76
    • /
    • 1988
  • In order to know the distribution, relative frequencies, types and morphology, endocrine cells in the intestinal tract of the hedgehog(Erinaceus koreanus) were studied by light microscopy, immunohistochemistry and electron microscopy. The results obtained are summarized as follows: 1. Two kinds of endocrine cells were demonstrated with two specific staining methods. Argyrophil cells(reactive cells for Grimelius method) were found most frequently in the intestinal region, and were infrequent in the rectum, whereas argentaffin cells (reactive cells for Masson-Hamperl method) were found most frequently in the rectum and in the other legions were infrequent. These reacting cells were mainly found in the intestinal glands, whereas a small number in the mucosa. 2. Twelve kinds of endocrine cells, gastrin(Gas)-, somatostatin (Som)-, serotonin(5-HT)-, glucagon(Glu)-, bovine pancreatic polypeptide(Bpp)-, cholecystokinin(Cck)-, secretin(Sec)-, motilin(Mot)-, glicentin(Gli)-, gastric inhibitor polypeptide(GIp)-, substance P(Sp)-, and neurotensin(Neu)-immunoreactive cells, were identified by immunohistochemical method. Gas-, Som-, 5-HT-, Glu-, Cck-, Sec-, Mot-, Gli-, Sp-, and Neu-reactive cells were observed in the duodenum, and among these Gas- and 5-HT-reactive cells were moderately found while the others were infrequent. In the jejunoileum Gas-, Som-, 5-HT-, Glu-, Cck-, Mot-, Gli-, GIp-, SP-, and Neu-reactive cells were found, and among these 5-HT- and GIp-reactive cells were moderately found while the others were infrequent. In the colon Sec-reactive cell was not detected. 5-HT-reactive cells were found most frequently and the others were infrequent in this region. 5-HT-, Bpp-, GIi- and Neu-reactive cells were found in the rectum. Among these 5-HT-reactive cells were found most frequently. 3. Electron microscopically, five types of endocrine cells, EC, ECL, D, G, A-like cell, were identified in the intestinal region. EC and ECL cells in the duodenum, EC, D and G cells in the jejuno-ileum, EC and A-like cells in the colon and EC cell in the rectum were observed respectively.

  • PDF

On a Goal-Directed Reactive Navigation Method for a Mobile Robot (이동 로봇의 자율주행을 위한 목표점 지향 반사 주행 방식)

  • 오용환;윤도영;오상록;박귀태
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.4
    • /
    • pp.246-257
    • /
    • 2004
  • This paper proposes two contributions. One is an analysis for the limit of the subject of goal-directed reactive robot navigation, and the other is an effective navigation method employing the scheme of the subject. The analysis for the subject is presented in order to clarify the limit of the method. On the basis of the analysis, a safety-guaranteeing and deadlock-free reactive navigation method is newly proposed. The proposed method has a simple behavior-based frame such that it can make the required navigation tasks such as obstacle avoidance, deadlock resolving, and etc. with a very small set of behaviors in entirely unknown environments such as a living room, an office, and etc. Some results of experiments show these validities.

Intervening Firing Method and Passive Filter Design for Harmonic Elimination and Reactive Power Compensation in Three-Phase Thyristor Phase-Controlled Converters Supplying a DC Motor

  • Pattanapongchai, Artite;Wongtongdee, Surached W.;Laohasongkram, Piphat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.813-816
    • /
    • 2005
  • This paper presents a method for harmonic elimination and reactive power compensation using an intervening firing method and passive power filter with is suitable to compensate rapidly changing loads and reactive power. The proliferation of three-phase thyristor phase-controlled converter of DC motor drives into a power system has the potential to increase the harmonic levels in the power system. The design procedure of an intervening firing method and passive power filter capable of reducing the voltage and current harmonics produced by converter supplied from a source having internal large inductive impedance is offered. The analysis uses the or CAD PSpice to model three-phase thyristor phase-controlled converter of DC motor drives as well as the system.

  • PDF

Studies on the One Bath Exhaust Dyeing System of Polyester/Cationized Cotton Blends with Disperse Dye/Reactive Dye (폴리에스테르/카티온화 면 혼방품의 분산염료/반응성염료에 의한 일욕염색계에 관한 연구)

  • 성우경
    • Textile Coloration and Finishing
    • /
    • v.10 no.2
    • /
    • pp.18-28
    • /
    • 1998
  • in order to overcome disadvantage of the conventional two bath dyeing method of polyester/cotton blends, it had prompted significant effort to the development of the one bath dyeing method which can accomplish sayings in time, energy and water usage. Also, when dyeing polyester/cotton blends by the one bath dyeing method, the high salt concentrations needed for the reactive dye can cause particles of disperse dye, used for the polyester component, to aggregate. A supplementary problem that can occasionally be happened is the change of hue that occurs on dyed polyester in an alkaline dyebath. To improve dyeing property of polyester/cotton blends, cotton component was pretreated with epichlolohydrine-trimethylamine hydrochloride in aqueous solution of sodium hydroxide to produce a cationized cotton that can be dyed under neutral conditions with reactive dye in a non-electrolytic or il little electrolytic dyebath. The one bath dyeing method of polyester/cationized cotton blends with disperse dye/reactive dye mixture resulted in a satisfactory dyeing property and color yield in comparison with ordinary two bath dyeing method.

  • PDF

CLHS Driving Method for Reducing Reactive Power Consumption in AC PDP (AC PDP의 무효전력 감소를 위한 CLHS 구동 방법)

  • Shin, Jae-Hwa;Kim, Gun-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.577-583
    • /
    • 2011
  • In AC-PDP, it is necessary to achieve high luminance efficiency, high luminance and high definition by adopting technologies such as high xenon concentration and long gap. However, it is very difficult to apply above technologies because they make many problems such as mis-discharge and high driving voltage. Especially, the reactive power of PDP must be reduced for satisfaction in international standard IEC62087. In this paper, we proposed CLHS driving method which is half sustain driver without energy recovery capacitor. In the experimental results, CLHS driving method reduced reactive power consumption about 10%. Also, CLHS driving method improved the luminance efficiency in all discharge loads. Therefor, the more the discharge load decreases, the more the luminance efficiency improves. When the discharge load is 20%, CLHS driving method improved 5.35%.

Static Voltage Stability Analysis using Reactive Power Loss Sensitivity (무효전력 손실감도를 이용한 정적 전압 안정도 해석)

  • Kim, Weon-Kyum;Lee, Bok-Yong;Lee, Sang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.52-55
    • /
    • 1999
  • In recent years, much attention has been paid to the voltage collapse phenomena. There has been reported many cases about the voltage collapse in many countries. These voltage collapse phenomena are known as the event that can occur due to reactive power deficits. This paper proposes an efficient method that can pursue the reactive power loss changes and gives the simple voltage collapse proximity indicator(VCPI) based on the reactive power loss sensitivities using optimal techniques. By comparing reactive power loss sensitivity with active power loss sensitivity, it is also proved that VCPI based on reactive power loss sensitivities is more effective. The developed VCPI is derived from the Jacobian matrix of Load Flow and the computational burden is very low and on-line implementation is possible. The proposed method is applied to a IEEE-14 bus test system and reliable and promising results are obtained.

  • PDF

Development of Optimal Power Flow for the Ancillary Service of Reactive Power Generation under Restructuring Environment (전력산업 구조개편 환경 하에서 무효전력 보조서비스 운용을 위한 최적조류계산법 개발)

  • Song, T.Y.;Jeong, M.H.;Lee, B.;NamGoong, J.Y.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.58-61
    • /
    • 2001
  • Under restructuring, not only real power pricing but also reactive power pricing is important for the system operation Especially, making a reasonable reactive power pricing is becoming more important than any other time. In this paper, the authors set a proper power factor and price the portion of the reactive power generation that exceeds the power factor. To apply this method to an optimization problem, we developed optimal power flow based on interior point method. By using this IPM for the power system, the System operator can use this strategy for reactive power generation pricing and also the Generators can got the motivation to generate reactive power.

  • PDF

A Study on Voltage Stability Assessment Using the Reactive Reserve Iindex (무효전력 예비력 지수를 이용한 전압안정도 평가 방안에 관한 연구)

  • Seo, Sang-Soo;Lee, Byong-Jun;Nam, Su-Chul;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.457-458
    • /
    • 2007
  • The reactive reserves of generators is close to voltage stability. This characteristic has led to the development of a few year monitoring the reactive reserves. In this paper, the reactive reserves have been calculated considering the generator capability curve. In addition, through dividing the systems using electric distance, the reactive reserves of each area has been calculated. Then, using the correlative relationship between reactive reserves and PV margins, the method for monitoring the voltage stability is proposed. The proposed method is tested on PSS/E test system and KEPCO system.

  • PDF