• Title/Summary/Keyword: Reactive Flow field

Search Result 45, Processing Time 0.031 seconds

Effects of Oxidizer Inject Angle on Combustion Characteristics in Hydro-Reactive Engine (Hydro-Reactive 엔진의 산화제 분사각도에 따른 연소특성에 대한 연구)

  • Won, Jong Han;Lee, Sung Nam;Baek, Seung Wook;Hwang, Chang Hwan;Kim, Kyung Moo
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.2
    • /
    • pp.1-7
    • /
    • 2014
  • In this study, the variation of the flow field in Hydro-reactive engine combustor was numerically studied through 2-dimensional axisymmetric model with aluminum and heated water vapor. For calculating all velocity fields, compressible Navier-Stokes equation was used with Pre-conditioning. AUSM+up(p) method was used to exactly calculate mass flow in the control volume. As using SST model that is a turbulent model, the result had high accuracy for free stream and the flow near the wall. The effects of the temperature, variation of the flow field and distribution of chemical products on inject angle of heated water vapor were studied.

Numerical Analysis of Turbulent Swirling Cold-Flow in a Cyclonic Coal Gasifier (선회분류층형 석탄가스화기내의 비반응 난류 선회유동장 해석)

  • 이진욱;나혜령;윤용승
    • Journal of Energy Engineering
    • /
    • v.6 no.2
    • /
    • pp.137-144
    • /
    • 1997
  • Turbulent swirling cold-flow in a cyclonic gasifier has been analyzed by numerical analysis. Comparison of two dimensional and three dimensional analyses has shown that concept of equivalent slit is appropriate for the two dimensionalization of three dimensional phenomena. Flow characteristics have been scrutinized by varying swirl number which is a crucial parameter in determining the flow pattern of the cyclonic gasifier. Reactive flow field has been estimated by using theoretical swirl number and equivalent slit width for reactive flow. Results show that proper flow field for the reactive coal gasification can be formed by controlling the exit area and azimuthal location of coal burners.

  • PDF

Satistical Analysis of SiO2 Contact Hole Etching in a Magnetically Enhanced Reactive Ion Etching Reactor

  • Liu, Chunli;Shrauner, B.
    • Journal of Magnetics
    • /
    • v.15 no.3
    • /
    • pp.132-137
    • /
    • 2010
  • Plasma etching of $SiO_2$ contact holes was statistically analyzed by a fractional factorial experimental design. The analysis revealed the dependence of the etch rate and DC self-bias voltage on the input factors of the magnetically enhanced reactive ion etching reactor, including gas pressure, magnetic field, and the gas flow rates of $CHF_3$, $CF_4$, and Ar. Empirical models of the DC self-bias voltage and etch rate were obtained. The DC self-bias voltage was found to be determined mainly by the operating pressure and the magnetic field, and the etch rate was related mainly to the pressure and the flow rates of Ar and $CHF_3$.

Formation of Reactive Oxygen Species and Cr(V) Entities in Chromium(VI) Exposed A549 Cells (크롬 6가 투여 후 A549 세포에서의 Reactive Oxygen Species와 크롬 5가의 발생)

  • 박형숙
    • Environmental Analysis Health and Toxicology
    • /
    • v.11 no.1_2
    • /
    • pp.49-57
    • /
    • 1996
  • The production of reactive oxygen species on addition of hexavalent chromium (potassium dichromate, $K_2Cr_2O_7$ ) to lung cells in culture was studied using flow cytometer analysis. A Coulter Epics Profile flow cytometer was used to detect the formation of reactive oxygen species after $K_2Cr_2O_7$ was added to A549 cells grown to confluence. The cells were loaded with the dye, 2',7'-dichlorofluorescein diacetate, after which cellular esterases removed the acetate groups and the dye was trapped intracellularly. Reactive oxygen species oxidized the dye, with resultant fluorescence. Increased doses of Cr(VI) caused increasing fluorescence (10-fold higher than background at 200 gM). Addition of Cr(III) compounds, as the picolinate or chloride, caused no increased fluorescence. Electron paramagnetic resonance (EPR) spectroscopic studies indicated that three (as yet unidentified) spectral "signals" of the free radical type were formed on addition of 20, 50, 100 and 200 gM Cr(VI) to the A549 cells in suspension. Two other EPR 'signals" with the characteristics of Cr(V) entities were seen at field values lower than the standard free radical value. radical value.

  • PDF

Transition temperatures and upper critical fields of NbN thin films fabricated at room temperature

  • Hwang, T.J.;Kim, D.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.3
    • /
    • pp.9-12
    • /
    • 2015
  • NbN thin films were deposited on thermally oxidized Si substrate at room temperature by using reactive magnetron sputtering in an $Ar-N_2$ gas mixture. Total sputtering gas pressure was fixed while varying $N_2$ flow rate from 1.4 sccm to 2.9 sccm. X-ray diffraction pattern analysis revealed dominant NbN(200) orientation in the low $N_2$ flow rate but emerging of (111) orientation with diminishing (200) orientation at higher flow rate. The dependences of the superconducting properties on the $N_2$ gas flow rate were investigated. All the NbN thin films showed a small negative temperature coefficient of resistance with resistivity ratio between 300 K and 20 K in the range from 0.98 to 0.89 as the $N_2$ flow rate is increased. Transition temperature showed non-monotonic dependence on $N_2$ flow rate reaching as high as 11.12 K determined by the mid-point temperature of the transition with transition width of 0.3 K. On the other hand, the upper critical field showed roughly linear increase with $N_2$ flow rate up to 2.7 sccm. The highest upper critical field extrapolated to 0 K was 17.4 T with corresponding coherence length of 4.3 nm. Our results are discussed with the granular nature of NbN thin films.

Identification of Noise Source of the HVAC Using Complex Acoustic Intensity Method (복소음향인텐시티법을 이용한 HVAC의 소음원 검출)

  • Yang, Jeong-Jik;Lee, Dong-Ju
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1089-1096
    • /
    • 2010
  • The relation between the vibration induced from machinery and the radiated sound is complicated. Acoustic intensity method is widely used to obtain the accuracy of noise measurement and noise identification. In this study, as groundwork, the complex acoustic intensity method is performed to identify noise source and transmission path on different free space point source fields. As an industrial application, the complex acoustic intensity method is applied to HVAC to identify sound radiation characteristics in the near field. Experimental complex acoustic intensity method was applied to HVAC, it is possible to identify noise sources in complicated sound field characteristics which noise sources are related with each other, and certificate the validity of complex acoustic intensity. Especially, it can be seen that complex acoustic intensity method using both of active and reactive intensity is vital in devising a strategy for identification of noise. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.

Post-chamber Flow and Performance of the Multi-port Combustor (다공 포트 연소기 후기 챔버의 유동 및 성능 특성 연구)

  • So, Jung-Soo;Kim, So-Ra;Song, Jae-Chon;Lee, Dong-Hoon;Yoon, Chang-Jin;Moon, Hee-Jang
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.15 no.4
    • /
    • pp.17-23
    • /
    • 2007
  • This paper describes the flow and performance characteristics inside the post-chamber of the multi-port hybrid rocket motor. Using the computational fluid dynamics (CFD) technique, the non reactive compressible flow fields in the downstream of the fuel grain was numerically calculated. The motor performance obtained from computational results were in agreement with that conducted by the ground motor firing test. Besides, the flow field characteristics inside the post-chamber were discussed under different port numbers (1 port and 3 ports) of the fuel grain. The flow pattern showed that the performance of multi-port hybrid rocket motor having three grain ports is higher than that of the single-port one due mainly to the difference of incoming mass flow rate irrespective to the pressure field.

  • PDF

Investigation of Turbulent Combustion Characteristics for Different Injector Port Diameter in Hybrid Rocket (하이브리드 로켓 인젝터 포트직경 변화에 따른 난류연소 유동장 해석)

  • Moon, Hee-Jang;Koo, Ja-Ye;Yoon, Chang-Jin;Min, Moon-Ki;Jang, Won-Jae
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.14 no.1
    • /
    • pp.2-8
    • /
    • 2006
  • Numerical analysis of the flow field in the reactive medium of End-Burring combustor is studied in order to investigate the combustion characteristics of hybrid combustion. The main part of this study is focused on the port diameter effects of oxidizer injector on the temperature distribution within the reactive field. It is found that the case having the largest port diameter(25 mm) delivers the optimum conditions for the design of End-Burring combustor where the predicted temperature field showed the most acceptable distribution.

  • PDF

Model Development for Analysis of Nitrate Leaching and Its Field Application in a Rural Area (농촌지역의 질산성질소 거동 해석을 위한 모델 개발 및 현장 적용)

  • Suk, Hee-Jun;Chon, Chul-Min
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.561-574
    • /
    • 2009
  • Unsaturated/saturated groundwater flow and solute transport model, VSFRT2D(Variable Saturated Flow and Reactive Transport model) was developed considering effects of pumping, irrigation, and denitrification. VSFRT2D employed Richards equation as governing equation for groundwater flow and previously existing unsaturated models modified by including computational procedure of evapotranspiration at surface using Thornthwaite method when precipitation doesn't occur. Bioremediation processes based on monod kinetics are described using four nonlinear contaminant transport equations and three nonlinear microbes transport equations. The developed model was applied to field data in Hongsung area contaminated with nitrate. In order to identify the effect of precipitation, pumping, evapotranspiration, irrigation, fertilizer application, and various bioremediations on groundwater flow and contaminant transport, individual processes were separated and simulated. Then all results obtained from the individual processes are compared with each other. The simulation results show that bioremediation had a negligible effect on nitrate concentration change. However, pumping for irrigation, precipitation, and nitrogen fertilizer application showed profound influences on nitrate concentration change.