• Title/Summary/Keyword: Reactive Component

Search Result 278, Processing Time 0.025 seconds

A Novel Method for Anti-Islanding Using Reactive Power Control (무효전력 제어를 통한 새로운 독립운전 검출법)

  • Jeong Jin-Beom;Choi Bong-Ju;Ahn Kang-Soon;Kim Hee-Jun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.4
    • /
    • pp.208-216
    • /
    • 2005
  • Recently, the study of islanding phenomenon, maintains its operation even when the utility grid is removed has lead to the trend of utility interactive inverters in photovoltaic generation systems. In this paper, a novel Anti-islanding method is presented. the proposed method can keep the real average power component constant by MPPT control and cause the load current frequency with only change of reactive power component under the islanding condition. its periodical change of Reactive power component can decrease the NDZ(Non-Detective zone) so that the detection of various loads will be possible. the insufficient effect if additional reactive power component to the grid is proved theoretically and the islanding detection is also confirmed from a experimental result with a inverter for 3kW photovoltaic generation system applied the proposed Anti-islanding method.

Comparison of Two Reactive Power Definitions in DFIG Wind Power System under Grid Unbalanced Condition

  • Ha, Daesu;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.213-214
    • /
    • 2014
  • This paper compares two instantaneous reactive power definitions in DFIG wind turbine with a back-to-back three-level neutral-point clamped voltage source converter under unbalanced grid conditions. In general, conventional definition of instantaneous reactive power is obtained by taking an imaginary component of complex power. The other definition of instantaneous reactive power can be developed based on a set of voltages lagging the grid input voltages by 90 degree. A complex quantity referred as a quadrature complex power is defined. Proposed definition of instantaneous reactive power is derived by taking a real component of quadrature complex power. The characteristics of two instantaneous reactive power definitions are compared using the ripple-free stator active power control algorithm in DFIG. Instantaneous reactive power definition based on quadrature complex power has a simpler current reference calculation control block. Ripple of instantaneous active and reactive power has the same magnitude unlike in conventional definition under grid unbalance. Comparison results of two instantaneous reactive power definitions are verified through simulation.

  • PDF

The Anti-Islanding Method with Compensation of Load Reactive Power for Grid-connected Photovoltaic Generation System (계통 연계형 태양광 발전 시스템의 부하 무효전력 보상이 적용된 단독운전 인지법)

  • Jeong, Jin-Beom;Shin, Dong-Hyun;Kim, Hee-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.58-64
    • /
    • 2008
  • In this paper, we present an active anti-islanding method with a load monitoring system using reactive power control. The proposed method, which is based on reactive power control, has fewer harmonics components than those in conventional methods, and it can minimize the reactive power component of the grid because it compensates the reactive power component with the load monitoring. The proposed quick islanding detection method was confirmed from the experimental results with an inverter for a 3kW photovoltaic system.

Studies on the One Bath Two Step Dyeing of Wool/Cationized Cotton Blends with Acid Dye/Reactive Dye (양모/카티온화 면 혼방품의 산성염료/반응성염료에 의한 1욕2단 염색에 관한 연구)

  • 성우경;이춘길;권오경
    • Textile Coloration and Finishing
    • /
    • v.11 no.2
    • /
    • pp.46-54
    • /
    • 1999
  • The conventional dyeing of wool/cotton blends involves a two bath two step method, i.e., after dyeing of the wool component with acid dyes in an acidic dyebath at $100^\circ{C}$, the dyeing of the cotton component with reactive dyes in an alkaline dyebath is performed. In order to overcome the disadvantage of the conventional two bath two step dyeing method of wool/cotton blends, it had prompted significant effort to the development of the one bath dyeing method which can accomplish savings in time, energy and water usage. To improve dyeing property of wool/cotton blends, cotton component was pretreated with cationizing agent containing chlorohydrine group in aqueous solution of sodium hydroxide. This study was carried out to investigate dyeing possibilities of wool/cationized cotton blends with acid dye/reactive dye by one bath two step method.

  • PDF

Component-Based Load Modeling Updated by Hybrid Technique (하이브리드 방식에 의한 미시적 부하모델링)

  • 지평식
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.179-182
    • /
    • 2003
  • Component-based method for load model not only should include the performances of the load components, but also should take into consideration the core losses of transformers, the line losses and the capacitor banks. Especially, capacitor bank affects the accuracy of reactive load model in load modeling. But it is difficult to identify actual reactive powers of capacitor banks in power system for load modeling. This research improves the component-based modeling method including uncertain capacitor bank. The proposed method is hybrid technique, which adds the measurement-based method to the existing component-based method for reliable information of capacitor band. The results of case studies were presented to verify the validity of the proposed method.

Studies on the One Bath Exhaust Dyeing System of Polyester/Cationized Cotton Blends with Disperse Dye/Reactive Dye (폴리에스테르/카티온화 면 혼방품의 분산염료/반응성염료에 의한 일욕염색계에 관한 연구)

  • 성우경
    • Textile Coloration and Finishing
    • /
    • v.10 no.2
    • /
    • pp.18-28
    • /
    • 1998
  • in order to overcome disadvantage of the conventional two bath dyeing method of polyester/cotton blends, it had prompted significant effort to the development of the one bath dyeing method which can accomplish sayings in time, energy and water usage. Also, when dyeing polyester/cotton blends by the one bath dyeing method, the high salt concentrations needed for the reactive dye can cause particles of disperse dye, used for the polyester component, to aggregate. A supplementary problem that can occasionally be happened is the change of hue that occurs on dyed polyester in an alkaline dyebath. To improve dyeing property of polyester/cotton blends, cotton component was pretreated with epichlolohydrine-trimethylamine hydrochloride in aqueous solution of sodium hydroxide to produce a cationized cotton that can be dyed under neutral conditions with reactive dye in a non-electrolytic or il little electrolytic dyebath. The one bath dyeing method of polyester/cationized cotton blends with disperse dye/reactive dye mixture resulted in a satisfactory dyeing property and color yield in comparison with ordinary two bath dyeing method.

  • PDF

Performance Verification of Anti-Islanding of Reactive Power Variation Method using Positive Feedback (정궤환을 이용한 무효전력 변동기반의 단독운전 방지 성능 검증)

  • Jo, Jongmin;Shin, Chang-Hoon;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.2
    • /
    • pp.105-110
    • /
    • 2019
  • This study proposed a reactive power variation (RPV) method equipped with positive feedback (PF) for detecting the islanding operation of distributed generation systems. The proposed RPV consists of the constant reactive power component and a certain reactive power term and uses the frequency deviation between the rated and the measured frequencies. The constant reactive power is injected from distributed generation system and power factor is to 0.9975 in grid-connected operation. PF is activated from generation of the frequency deviation and the injected reactive power is continuously increased due to PF when islanding occurs. Consequently, the increasing reactive power causes the point of common coupling frequency to deviate from the maximum/minimum threshold level. Performance of the proposed RPV is verified in a 1.7 kW T-type inverter, and the detection times are 53 and 150 ms.

Static Load Modeling Based on Artificial Neural Network and Harmonics (고조파를 고려한 신경회로망 기반의 정태부하모델링)

  • Lee, Jong-Pil;Kim, Sung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.2
    • /
    • pp.65-71
    • /
    • 2013
  • Nonlinear loads with harmonics exist in an actual power system where harmonic currents make voltage distortion. The sum of reactive power measured at individual load is different from the measured reactive power at a bus in a power system with linear and non-linear loads. In this study, ANN(artificial neural network) load modeling technique with consideration of harmonics is introduced for more accurate component load modeling and an impact coefficient is proposed for aggregation of component loads. Results of this research show more accurate load modeling method. Since precise data for power system analysis can be acquired, the proposed method will be used for power system planning and maintenance.

Reactive Power Control of Single-Phase Reactive Power Compensator for Distribution Line (배전선로용 단상 무효전력 보상기의 무효전력제어)

  • Sim, Woosik;Jo, Jongmin;Kim, Youngroc;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.73-78
    • /
    • 2020
  • In this study, a novel reactive power control scheme is proposed to supply stable reactive power to the distribution line by compensating a ripple voltage of DC link. In a single-phase system, a magnitude of second harmonic is inevitably generated in the DC link voltage, and this phenomenon is further increased when the capacity of DC link capacitor decreases. Reactive power control was performed by controlling the d-axis current in the virtual synchronous reference frame, and the voltage control for maintaining the DC link voltage was implemented through the q-axis current control. The proposed method for compensating the ripple voltage was classified into three parts, which consist of the extraction unit of DC link voltage, high pass filter (HPF), and time delay unit. HPF removes an offset component of DC link voltage extracted from integral, and a time delay unit compensates the phase leading effect due to the HPF. The compensated DC voltage is used as feedback component of voltage control loop to supply stable reactive power. The performance of the proposed algorithm was verified through simulation and experiments. At DC link capacitance of 375 uF, the magnitude of ripple voltage decreased to 8 Vpp from 74 Vpp in the voltage control loop, and the total harmonic distortion of the current was improved.

Harmonic and Reactive power compensation of standby power supply(SPS) using digital controller (디지탈 제어기에 의한 예비전원장치 (SPS)에서의 고조파 및 무효전력보상)

  • Park, Ga-Woo;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.498-501
    • /
    • 1994
  • This paper presents a digital calculation method of instantaneous reactive power component for standby power supply(SPS) system. Reactive current is defined in time domain, calculated instantaneously by using a TMS320C25. The theoretical analysis is verified by the digital simulation and experimental results.

  • PDF