• 제목/요약/키워드: Reactive Compensation

검색결과 319건 처리시간 0.027초

A Stable Operation Strategy in Micro-grid Systems without Diesel Generators

  • Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Nam, Yang-Hyun;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.114-123
    • /
    • 2018
  • Recently, as one of the countermeasures to reduce carbon dioxide($CO_2$) for global warming problems, operation methods in micro-grid systems replacing diesel generator with renewable energy sources including wind power(WP) and photovoltaic(PV) system have been studied and presented in energetic manners. However, it is reported that some operation problems in micro-grid systems without diesel generator for carbon-free island are being occurred when large scaled WP systems are at start-up. To overcome these problems, this paper proposes an operation strategy in micro-grid systems by adapting control devices such as CVCF(constant voltage constant frequency) ESS(energy storage system) for constant frequency and voltage regulation, load control ESS for balancing demand and supply and SVC(static-var compensator) for reactive power compensation. From the simulation results based on the various operation scenarios, it is confirmed that the proposed operation strategy in micro-grid systems without diesel generators is a useful tool to perform a stable operation in micro-grid systems without diesel generator and also make a contribution to reduce carbon dioxide in micro-grid systems.

SVM 기반 히스테리시스 제어기를 이용한 D-STATCOM 전류 제어에 관한 연구 (A Study on Current Control using a Novel SVM-Based Hysteresis Controller in D-STATCOM)

  • 최정혜;신은철;유지윤
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.293-301
    • /
    • 2006
  • 배전급 STATCOM(Distribution-network STATic synchronous COMpensator)에 적용 가능한 공간 벡터 변조 (Space Vector Modulation, SVM) 기법을 이용한 히스테리시스 전류제어기를 제안하였다. 히스테리시스 전류제어기는 빠른 응답 특성, 쉬운 구현, 파라미터 변화에 대한 둔감성 등 많은 장점에도 불구하고 높은 스위칭 주파수와 제한되지 않는 전류 오차 때문에 스위칭 주파수에 영향을 받는 배전급 STATCOM 전류제어기로는 적합하지 않았다. 또한 전압 벡터의 인가방식에서도 뚜렷한 근거가 없어 전류오차가 제한되지 않았다. 이에 본 논문에서는 구역판별기, SVM, 그리고 외부와 내부 히스테리시스 제어기를 이용하여 높은 스위칭 주파수를 저감하고 특정 밴드 내에서 전류 오차를 줄인 개선된 SVM 기반의 히스테리시스 전류제어기를 제안하고 모의실험을 통해 제안한 기법의 유효성을 입증하였다.

풍속계와 Motor-Generator 세트를 이용한 DFIG 풍력발전시스템 하드웨어 시뮬레이터 개발 (Development of Hardware Simulator for DFIG Wind Power System Composed of Anemometer and Motor-Generator Set)

  • 오승진;차민영;김종원;정종규;한병문;장병훈
    • 전력전자학회논문지
    • /
    • 제16권1호
    • /
    • pp.11-19
    • /
    • 2011
  • 본 연구에서는 풍력발전시스템의 다양한 특성들을 고려한 DFIG풍력발전시스템 하드웨어 시뮬레이터를 개발하였다. 개발한 하드웨어 시뮬레이터는 유도전동기를 이용한 풍력터빈 모델과 이중여자 유도발전기 그리고 컨버터와 인버터로 구성된 Back-to-Back컨버터로 구성되었다. 특히 풍력터빈 시뮬레이터는 풍속계를 이용하여 실시간으로 풍속을 측정하고 측정된 바람으로 블레이드의 특성을 모의하였다. DFIG풍력발전 시뮬레이터에서 생산되는 전력은 MPPT제어를 수행하는 MSC(Machine Side Converter)와 DC link전압을 일정하게 제어하는 GSC(Grid Side Converter)에 의해 계통에 연계되어 운전한다. 제안하는 시스템은 PSCAD/EMTDC 프로그램을 이용하여 시뮬레이션 하였으며, 축소모형실험을 통해서 성능을 검증하였다.

Compensation of Unbalanced PCC Voltage in Off-shore Wind Farms of PMSG Type Turbine

  • Kang, Jayoon;Han, Daesu;Suh, Yongsug;Jung, Byoungchang;Kim, Jeongjoong;Park, Jonghyung;Choi, Youngjoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.215-216
    • /
    • 2014
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

Type-2 Fuzzy Logic Predictive Control of a Grid Connected Wind Power Systems with Integrated Active Power Filter Capabilities

  • Hamouda, Noureddine;Benalla, Hocine;Hemsas, Kameleddine;Babes, Badreddine;Petzoldt, Jurgen;Ellinger, Thomas;Hamouda, Cherif
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1587-1599
    • /
    • 2017
  • This paper proposes a real-time implementation of an optimal operation of a double stage grid connected wind power system incorporating an active power filter (APF). The system is used to supply the nonlinear loads with harmonics and reactive power compensation. On the generator side, a new adaptive neuro fuzzy inference system (ANFIS) based maximum power point tracking (MPPT) control is proposed to track the maximum wind power point regardless of wind speed fluctuations. Whereas on the grid side, a modified predictive current control (PCC) algorithm is used to control the APF, and allow to ensure both compensating harmonic currents and injecting the generated power into the grid. Also a type 2 fuzzy logic controller is used to control the DC-link capacitor in order to improve the dynamic response of the APF, and to ensure a well-smoothed DC-Link capacitor voltage. The gained benefits from these proposed control algorithms are the main contribution in this work. The proposed control scheme is implemented on a small-scale wind energy conversion system (WECS) controlled by a dSPACE 1104 card. Experimental results show that the proposed T2FLC maintains the DC-Link capacitor voltage within the limit for injecting the power into the grid. In addition, the PCC of the APF guarantees a flexible settlement of real power exchanges from the WECS to the grid with a high power factor operation.

분로리액터 개폐 과전압 해석을 위한 EMTP 모델링 (Electromagnetic Transient Program Modeling for Analysis of Switching Over-Voltage on Shunt Reactor)

  • 오승열;전인영;한기선;강지원
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.393-397
    • /
    • 2020
  • 무효전력 보상설비인 분로리액터는 전력계통의 부하 패턴에 따라서 하루에도 수 회 정도 차단기에 의해 운전되거나 정지된다. 분로리액터개폐 시 몇 가지 요인에 의해 발생하는 과전압은 차단기의 절연 성능을 저하시키며, 계통을 구성하는 전력기기에 심각한 전압 스트레스를 유발한다. 분로리액터 개폐 과정에서 발생하는 과도현상을 측정하는 것은 계통을 모의하여 차단기 성능을 검증하는 시험소 수준에서는 가능하나, 실제 계통 운전 중에 발생하는 과도현상을 측정하는 것은 여러 가지 제약으로 어려움이 있다. 따라서 본 논문에서는 실 계통에서 지상 소전류 차단과정에서 가혹한 과도회복전압(TRV: Transient Recovery Voltage)을 유발하는 재발호(reignition)나 전류재단(current chopping) 현상에 대한 해석을 위해 전자계과도해석프로그램(EMTP: Electro-magnetic Transients Program)을 활용한 모델링 과정과 이를 토대로 분로리액터 개폐 과정에서 차단기의 고장을 유발하는 주된 현상에 대해 해석하고자 한다.

Performance Improvement in Single-Phase Electric Spring Control

  • Wang, Qingsong;Zuo, Wujian;Cheng, Ming;Deng, Fujin;Buja, Giuseppe
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.784-793
    • /
    • 2019
  • Two objectives can be pursued simultaneously with the ${\delta}$ control of a single-phase electric spring (ES). These objectives are the stabilization of the voltage across the critical load (CL) of a power system, and the achievement of a specific functionality similar to the pure compensation of reactive power or the correction of the power factor. However, existing control systems implementing the ${\delta}$ control do not cope with non-ideal operating conditions, such as line voltage distortions, and exhibit a somewhat sluggish regulation of the CL voltage. In an effort to improve both the steady-state and transient performances of an ES power system, this paper proposes implementing the ${\delta}$ control by means of a control system built up on the repetitive control and assisted by state feedback with pole assignment. This paper starts by analyzing the dynamics of an ES power system in terms of its poles and zeros. After that, a reduced second-order model of the dynamics is formulated to avoid a notch filter in the pole assignment. A repetitive control for an ES power system is then designed to meet the two above mentioned objectives. Experimental tests carried out on a laboratory setup demonstrate the effectiveness of the proposed control system in significantly improving the ES power system performance, while reaching the two objectives. In particular, the tests outline the large mitigation of harmonics in the CL voltage under line voltage distortions and its fast stabilization action.

γ-C2S 및 MgO를 다량 혼입한 시멘트 페이스트의 CO2 양생유무에 따른 특성변화 (Properties of Cement Paste Containing High Volume γ-C2S and MgO Subjected to CO2 Curing)

  • 성명진;조형규;이한승
    • 한국건축시공학회지
    • /
    • 제15권3호
    • /
    • pp.281-289
    • /
    • 2015
  • 본 연구에서는 $CO_2$ 양생 효과를 극대화 할 수 있는 ${\gamma}-C_2S$와 MgO와 같은 $CO_2$ 흡수 물질을 혼입한 시멘트 페이스트의 $CO_2$ 양생 효과에 관한 연구를 위하여 W/B를 40%로 설정하고 혼화재료 ${\gamma}-C_2S$와 MgO를 90% 다량 치환하여 혼화재료, $CO_2$ 양생 유무에 따른 압축강도 측정, 미세 화학분석을 실시하였다. 그 결과 $CO_2$ 양생으로 인해 Plain의 경우 약 1.08배~1.26배의 압축강도 증가 효과가 나타났으며 ${\gamma}-C_2S$와 MgO를 90% 치환한 ${\gamma}-C_2S$, MgO 실험체의 경우, 각각 14.56배~45.7배, 6.5배~10.37배 향상 효과가 나타났다. 이에 따라 미세 화학분석을 실시하여 다량의 $CaCO_3$, $MgCO_3$가 생성된 것을 확인하고 공극 감소의 효과를 확인하였다. 따라서 $CO_2$ 흡수물질 ${\gamma}-C_2S$, MgO를 다량 혼입한 시멘트 페이스트의 $CO_2$ 양생에 의한 압축강도 발현효과가 검증됨을 확인할 수 있었다.

Can Lufthansa Successfully Limit its Liability to the Families of the Victims of Germanwings flight 9525 Under the Montreal Convention?

  • Gipson, Ronnie R. Jr.
    • 항공우주정책ㆍ법학회지
    • /
    • 제30권2호
    • /
    • pp.279-310
    • /
    • 2015
  • 몬트리올협약은 국제항공운송에서 발생한 사고에 따른 여객의 사망이나 상해에 관하여 항공운송인의 책임을 배타적으로 규율하고 있다. 국제항공산업의 재정적인 안정과 항공사를 파산으로 이끌 수도 있는 과도한 배상책임으로부터 항공산업을 보호할 목적으로 몬트리올협약은 금전배상에 있어서 책임제한제도를 운영하고 있다. 하지만 여객의 사망이나 상해가 항공사 혹은 그 대리인의 직접적인 과실이나 불법적인 작위 혹은 부작위의 결과라는 점이 인정될 경우에 그러한 책임제한원칙은 유지될 수 없고, 손해배상을 청구하는 자는 협약이 정하는 제한책임액 이상의 배상을 받을 수도 있다. 한편, 몬트리올협약은 손해배상을 청구하는 원고가 소송을 제기할 수 있는 법정지에 관해서도 관할권 관련 조항에서 일정한 제한을 두고 있다. 이러한 관할권은 특히 피고 항공운송인의 영업소나 원고의 주소지가 주요 결정요인이 된다. 지난 2015년 3월, Germanwings 항공사 9525편에 발생한 사고는 당시 심한 우울증을 앓고 있었던 부기장의 의도적인 행동이 원인이었고, 해당 항공기가 프랑스령 알프스산맥에 추락하면서 대부분의 탑승 여객과 승무원의 사망이라는 결과로 이어졌다. 보도 자료에 따르면 사고 직후, 항공사는 사망승객의 국적에 따라 금액의 차이는 있지만 미화 8,300불에서 4백5십만불에 이르는 손해배상액을 합의금으로 제시하였다고 한다. 이러한 합의제안에 대해 몇몇 유가족들은 보다 많은 배상액을 얻기 위하여 미국과 같이 피해자에게 관대한 법정지에서 소송제기를 계획하고 있다고 한다. 본 논문은 위 사고와 관련하여 두 가지 쟁점에 관하여 기술하고 있다. 첫째, 본 논문은 몬트리올협약상 관할권 조항과 관련하여 미국 시민이 아닌 피해자가 미국 법정지에서 소송을 제기할 가능성에 대해 살펴보았다. 둘째, 본 사고의 직접적인 원인이 부기장의 의도된 사고유발 행동이었던 점에서 사안의 항공사는 몬트리올협약이 규정하고 있는 책임제한원칙이 부정될 가능성이 있다. 이에 관하여 본 논문은 해당 항공사가 그럼에도 불구하고 협약상 책임제한규정을 원용할 수 있는 가능성이 있는지 여부를 중점적으로 살펴보았다.