• Title/Summary/Keyword: Ratio of the Window

Search Result 400, Processing Time 0.028 seconds

Comparative Study of Tritium Analysis Method with High-Volume Counting Vial

  • Yoon, Yoon Yeol;Kim, Yongcheol
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.142-146
    • /
    • 2020
  • Background: Tritium (3H) analysis in groundwater was difficult because of its low activity. Therefore, the electrolytic enrichment method was used. To improve the detection limit and for performing simple analysis, a high-volume counting vial with the available liquid scintillation counter (LSC) was investigated. Further, it was compared with a conventional 20-mL counting vial. Materials and Methods: The LSC with the electrolytic enrichment method was used 3H analysis in groundwater. A high-volume 145-mL counting vial was compared with a conventional 20-mL counting vial to determine the counting characteristics of different LSCs. Results and Discussion: When a Quantulus LSC was used, the counting window between channels 35 and 250 was used. The background count was approximately 1.86 cpm, and the counting efficiency increased from 8% to 40% depending on the mixing ratio of the volume of sample and cocktail solution. For LSC-LB7, the optimum counting window was between 1 and 4.9 keV, which was selected by the factory (Hitachi Aloka Medical Ltd., Japan) by considering quenching using a standard external gamma source. The background count of LSC-LB7 was approximately 3.60 ± 0.29 cpm when the 145-mL vial was used and 2.22 ± 0.17 cpm when the 20-mL vial was used. The minimum detectable activity (MDA) of the 20-mL vial was greater for LSC-LB7 than for Quantulus. The MDA with the 145-mL vial was improved to 0.3 Bq/L when compared with the value of 1.6 Bq/L for the 20-mL vial. Conclusion: The counting efficiency when using the 145-mL vial was 27%, whereas it was 18% when using the 20-mL vial. This difference can be attributed to the vial volume. The figure of merit (FOM) of the 145-mL vial was four times greater than that of the 20-mL vial because the volume of the former vial is approximately seven times greater than that of the latter. Further, the MDA for 3H decreased from 1.6 to 0.3 Bq/L. The counting efficiency and FOM of LSC-LB7 was slightly less than those of Quantulus when the 20-mL vial was used. The background counting rate of the Quantulus was lower than that of the LSC-LB7.

Performance Analysis of Noncoherent OOK UWB Transceiver for LR-WPAN (저속 WPAN용 비동기 OOK 방식 UWB 송수신기 성능 분석)

  • Ki Myoungoh;Choi Sungsoo;Oh Hui-Myoung;Kim Kwan-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.11A
    • /
    • pp.1027-1034
    • /
    • 2005
  • IEEE802.15.4a, which is started to realize the PHY layer including high precision ranging/positioning and low data rate communication functions, requires a simple and low power consumable transceiver architecture. To satisfy this requirements, the simple noncoherent on-off keying (OOK) UWB transceiver with the parallel energy window banks (PEWB) giving high precision signal processing interface is proposed. The flexibility of the proposed system in multipath fading channel environments is acquired with the pulse and bit repetition method. To analyze the bit error rate (BER) performance of this proposed system, a noise model in receiver is derived with commonly used random variable distribution, chi-square. BER of $10^{-5}$ under the line-of-sight (LOS) residential channel is achieved with the integration time of 32 ns and signal to noise ratio (SNR) of 15.3 dB. For the non-line-of-sight (NLOS) outdoor channel, the integration time of 72 ns and SNR of 16.2 dB are needed. The integrated energy to total received energy (IRR) for the best BER performance is about $86\%$.

Analysis on the installation criteria and ventilation effect for round roof windows in single-span plastic greenhouses (단동 플라스틱 온실의 천창 환기효과와 설치기준 분석)

  • Nam, Sang-Woon;Kim, Young-Shik;Ko, Gi-Hyuk;Sung, In-Mo
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.2
    • /
    • pp.271-277
    • /
    • 2012
  • Dimensions, operation conditions and improvement items for round roof windows were investigated in arch shape single-span plastic greenhouse with roof vents, and natural ventilation performance was analyzed based on the ventilation theory. Diameter of round roof windows was mostly 60 cm, and chimney height projected on roof was average 30 cm. Installation space was mostly 5 to 6 m but farmhouse of 10 m and over was 16.7% also. A round roof window which has 60 cm diameter was installed to 6 m space generally and 80 cm diameter was installed to 10 m space, but correct standards did not exist. There were a lot of opinions that ventilation effect of round roof windows is fairly good and user satisfaction is generally excellent. It is problem that there is few effects in summer and that vinyl around each vent tears well and rainwater leaks, and improvement hope item required development of automatic control system. In the wind speed of 0.3 m/s, it was estimated that natural ventilation rates were 0.69, 0.55, 0.50 and 0.48 volumes per minute in case of 2, 4, 6 and 8 m installation space for round roof windows, respectively. It was analyzed that the ratio of ventilation due to buoyancy out of total ventilation were 65.2, 41.9, 29.9 and 22.8% in case of 2, 4, 6 and 8m installation space, respectively. By the round roof windows installed at space of 6 m, ventilation rate was estimated to 0.5 volumes per minute, and we can expect the increase in ventilation rate of 30%. In order to meet the recommended ventilation rate for summer season, we have to install the round roof windows at space of 1 to 2 m. However, it is difficult to apply those installation space because of falling productivity due to lower light transmittance as well as rising costs. It is estimated that the installation space of 6m is appropriate for spring or fall season. Therefore it is necessary to encourage installing the roof windows in single-span plastic greenhouses.

The Analysis of Dioxin-like PCBs in Fishes and Shellfishes using Accelerated Solvent Extraction (ASE) System and Multilayer Column Chromatography (가속용매추출장치(ASE) 및 다층크로마토그래피를 이용한 어패류 중의 dioxin-like PCBs의 분석)

  • Oh, Keum-Soon;Park, Seong-Soo;Chung, So-Young;Sho, You-Sub;Kim, Jung-Soo;Jang, Seoung-Chul;Lee, Jong-Ok;Kim, Hee-Yun;Woo, Gun-Jo;Suh, Jung-Hyuck
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.2
    • /
    • pp.122-127
    • /
    • 2007
  • In this study, an analytical method was optimized for detecting dioxin-like PCBs in fish and shellfish. Here, homogenized samples were extracted using an accelerated solvent extraction (ASE) system with 33 mL cell size. Multilayer column chromatography, which consisted of acidic, basic and neutral silica gels, was used for the clean up of the extracts. The instrumental analysis was executed by HRGC/HRMS to a resolution of 10,000 using 4 window multiple ion detection (MID) mode. For the results, the average recoveries ranged from 94.1 to 104.1% (${\pm}8.4$) and the limit of detection was approximately 0.1 pg/g at S/N ratio >3. Finally, the detected concentrations of dioxin-like PCBs for fish and shellfish were in the range of 0.030-1.836 pg TEQ/g.

Characteristics of Pd Catalysts for Methane Oxidation (메탄 산화를 위한 Pd 촉매의 특성)

  • Lee, Jin-Man;Yang, O-Bong;Kim, Chun-Yeong;Woo, Seong-Ihl
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.557-562
    • /
    • 1999
  • The reaction properties of Pd. Pd-Ce and Pd-La catalysts supported on ${\gamma}-Al_2O_3$ were investigated in the oxidation reaction of methane($CH_4$) exhausted from the compressed natural gas vehicle in a U-tube flow reactor with gas hourly space velocity of $72,000h^{-1}$. The catalysts were characterized by X-ray diffraction(XRD), X-ray photoelectron spectroscopy(XPS), BET surface area and hydrogen chemisorption. Pd catalyst prepared by $Pd(NO_3)_2$ as a palladium precursor and calcined at $600^{\circ}C$ showed the highest activity for a methane oxidation. Catalytic activity of calcined $Pd/{\gamma}-Al_2O_3$ in which most of palladium was converted into palladium oxide species was higher than that of reduced $Pd/{\gamma}-Al_2O_3$ in which most of palladium existed in palladium metal by XRD. As increasing the number of reaction cycles in the wide range of redox, the catalytic activity of $Pd/{\gamma}-Al_2O_3$ was decreased and the highly active window became narrower. Lanthanum oxide promoted Pd catalyst, $Pd/La/{\gamma}-Al_2O_3$ showed enhanced thermal stability compared with $Pd/{\gamma}-Al_2O_3$ even after aging at $1000^{\circ}C$, which was ascribed to the role of La as a promoter to suppress the sintering of palladium metal and ${\gamma}-Al_2O_3$ support. Almost all of methane was removed by the reaction with NO at the redox ratio of 1.2 in case of oxygen excluded steam, but that activity was significantly decreased in the steam containing oxygen.

  • PDF

The Understanding and Application of Noise Reduction Software in Static Images (정적 영상에서 Noise Reduction Software의 이해와 적용)

  • Lee, Hyung-Jin;Song, Ho-Jun;Seung, Jong-Min;Choi, Jin-Wook;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • Purpose: Nuclear medicine manufacturers provide various softwares which shorten imaging time using their own image processing techniques such as UlatraSPECT, ASTONISH, Flash3D, Evolution, and nSPEED. Seoul National University Hospital has introduced softwares from Siemens and Philips, but it was still hard to understand algorithm difference between those two softwares. Thus, the purpose of this study was to figure out the difference of two softwares in planar images and research the possibility of application to images produced with high energy isotopes. Materials and Methods: First, a phantom study was performed to understand the difference of softwares in static studies. Various amounts of count were acquired and the images were analyzed quantitatively after application of PIXON, Siemens and ASTONISH, Philips, respectively. Then, we applied them to some applicable static studies and searched for merits and demerits. And also, they have been applied to images produced with high energy isotopes. Finally, A blind test was conducted by nuclear medicine doctors except phantom images. Results: There was nearly no difference between pre and post processing image with PIXON for FWHM test using capillary source whereas ASTONISH was improved. But, both of standard deviation(SD) and variance were decreased for PIXON while ASTONISH was highly increased. And in background variability comparison test using IEC phantom, PIXON has been decreased over all while ASTONISH has shown to be somewhat increased. Contrast ratio in each spheres has also been increased for both methods. For image scale, window width has been increased for 4~5 times after processing with PIXON while ASTONISH showed nearly no difference. After phantom test analysis, ASTONISH seemed to be applicable for some studies which needs quantitative analysis or high contrast, and PIXON seemed to be applicable for insufficient counts studies or long time studies. Conclusion: Quantitative values used for usual analysis were generally improved after application of the two softwares, however it seems that it's hard to maintain the consistency for all of nuclear medicine studies because result images can not be the same due to the difference of algorithm characteristic rather than the difference of gamma cameras. And also, it's hard to expect high image quality with the time shortening method such as whole body scan. But it will be possible to apply to static studies considering the algorithm characteristic or we can expect a change of image quality through application to high energy isotope images.

  • PDF

An Efficient TCP Buffer Tuning Algorithm based on Packet Loss Ratio(TBT-PLR) (패킷 손실률에 기반한 효율적인 TCP Buffer Tuning 알고리즘)

  • Yoo Gi-Chul;Kim Dong-kyun
    • The KIPS Transactions:PartC
    • /
    • v.12C no.1 s.97
    • /
    • pp.121-128
    • /
    • 2005
  • Tho existing TCP(Transmission Control Protocol) is known to be unsuitable for a network with the characteristics of high RDP(Bandwidth-Delay Product) because of the fixed small or large buffer size at the TCP sender and receiver. Thus, some trial cases of adjusting the buffer sizes automatically with respect to network condition have been proposed to improve the end-to-end TCP throughput. ATBT(Automatic TCP fluffer Tuning) attempts to assure the buffer size of TCP sender according to its current congestion window size but the ATBT assumes that the buffer size of TCP receiver is maximum value that operating system defines. In DRS(Dynamic Right Sizing), by estimating the TCP arrival data of two times the amount TCP data received previously, the TCP receiver simply reserves the buffer size for the next arrival, accordingly. However, we do not need to reserve exactly two times of buffer size because of the possibility of TCP segment loss. We propose an efficient TCP buffer tuning technique(called TBT-PLR: TCP buffer tuning algorithm based on packet loss ratio) since we adopt the ATBT mechanism and the TBT-PLR mechanism for the TCP sender and the TCP receiver, respectively. For the purpose of testing the actual TCP performance, we implemented our TBT-PLR by modifying the linux kernel version 2.4.18 and evaluated the TCP performance by comparing TBT-PLR with the TCP schemes of the fixed buffer size. As a result, more balanced usage among TCP connections was obtained.

Study on Applicability of Stereophotogrammetry to Rock Joint Survey (입체사진측량기법의 암반절리조사에 대한 적용성 연구)

  • Han, Jeong-Hun;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.17 no.2 s.67
    • /
    • pp.139-151
    • /
    • 2007
  • Stereophotogrammetry is a method to extract information of an interested area by constructing a stereo-image from two or more photos. In this study, the stereophotogrammetry was adopted to obtain the joint orientation and trace length from a sampling window and its measurements were compared with the result by a clinocompass and measuring tape to evaluate the applicability of the stereophotogrammetry to rock joint survey. A commercial stereophotogrammetry program, ShapeMetriX 3D, was used for this purpose. Firstly, the accuracy of the measuring method using ShpaeMetrix 3D was evaluated by a model test. Secondly, joint orientations on a rock slope and tunnel were obtained by using ShapeMetriX 3D and compared with the measurement by a clinocompass. Finally. the effect of base-depth ratio in photographing was evaluated by comparing images with various base-depth ratios, and the usefulness of closed-up photographing on a rock exposure to increase the measurement accuracy was tested. The dip and dip direction of each model plane obtained by ShapeMetriX 3D showed an error ranged between $-5^{\circ}\;and\; 5^{\circ}$ on the basis of the results by the measuring tape. Base-depth ratio proved not to influence the analysis result by ShapeMetriX 3D if all the images were taken without any hidden area. The close-up photographing turned out useful to obtain the detailed images and therefore precise result when ShapeMetriX 3D was adopted.

The Characteristics of Driving Parameters and CO2 Emissions of Light-Duty Vehicles in Real-Driving Conditions at Urban Area in Seoul (서울 도심의 실제 도로 주행 조건에서 소형자동차의 주행인자와 CO2 배출 특성에 관한 연구)

  • Park, Junhong;Lee, Jongtae;Kim, Sunmoon;Kim, Jeongsoo;Ahn, Keunhwan
    • Journal of Climate Change Research
    • /
    • v.4 no.4
    • /
    • pp.359-369
    • /
    • 2013
  • In this paper, correlations between driving parameters and $CO_2$ of light-duty vehicles have been analyzed. Three test vehicles equipped with PEMS (Portable Emission Measurement System) have been driven in real-road in urban areas of Seoul. Averaged vehicle speed, RPA(Relative Positive Acceleration) and stop ratio have been selected as main driving parameters. The analysis have been conducted in interrupted and uninterrupted road types. Averaged values in various driving conditions have been calculated with distance based moving averaging window method. The multiple linear regression method have been applied to account for correlation between driving parameters and $CO_2$ emissions. This approach has shown statistically that $CO_2$ emission per distance (g/km) have tendencies to be increased as decreased averaged vehicle speed and increased RPA and stop ratio. Compared with uninterrupted traffic, interrupted traffic have shown the lower vehicle speed and the higher RPA and stop ratio. These characteristics of driving parameters in interrupted traffic should cause the higher $CO_2$ emission per distance.

Effect of Doubly Plasma Oxidation Time on TMR Devices (이중절연층 산화공정에서 플라즈마 산화시간에 따른 터널자기저항 효과)

  • Lee, Ki-Yung;Song, Oh-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.4
    • /
    • pp.127-131
    • /
    • 2002
  • We fabricated MTJ devices that have doubly oxidized tunnel barrier using plasma oxidation method to from oxidized AlO$\sub$x/ tunnel barrier. Doubly oxidation I, which sputtered 10 ${\AA}$-bottom Al layer and oxidized it with oxidation time of 10 s. Subsequent sputtering of 13 ${\AA}$-Al was performed and the metallic layer was oxidized for 50, 80 and 120 s., respectively. Doubly oxidation II, which sputtered 10 ${\AA}$-bottom Al layer and oxidized it varying oxidation time for 30∼120 s. Subsequent sputtering of 13 ${\AA}$-Al was performed and the metallic layer was oxidized for 210 sec. Double oxidation process specimen showed MR ratio of above 27% in all experiment range. Singly oxidation process. 13 ${\AA}$-Al layer and oxidized up to 210 s, showed less MR ratio and more narrow process window than those of doubly oxidation. Cross-sectional TEM images would that doubly oxidized barrowers were thinner and denser than singly oxidized ones. XPS characterization confirmed that doubly oxidation of Fe with bottom insulating layer. As a result, doubly oxidation could have superior MR ratio in process extent during long oxidation time because of preventing oxidation of bottom magnetic layer than singly oxidation.