• 제목/요약/키워드: Ratio Error

검색결과 2,588건 처리시간 0.052초

전류변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 현장 평가기술 (On-Site Evaluation Technique of Linearity for Ratio Error and Phase Angle Error of Current Transformer Comparison Measurement Equipment)

  • 정재갑;권성원;이상화;강전홍;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권6호
    • /
    • pp.313-316
    • /
    • 2006
  • A method for evaluation of the linearity of both the ratio error and phase angle error in the current transformer(CT) comparison measurement equipment has been developed by employing the standard resistors with negligible AC-DC resistance difference less than $10^{-5}$. The non-reactive standard resistors for the linearity check of the system are used as the external burden connected with the secondary of CT under test. These burdens consist of nine standard resistors, with the nominal resistance of $0.01{\Omega},\;0.1{\Omega},\;0.2{\Omega},\;0.4{\Omega},\;0.6{\Omega},\;1{\Omega},\;2{\Omega},\;4{\Omega}$, and $10{\Omega}$. For linearity check, the developed method has been applied in the CT comparison measurement equipment belonging to the industry.

전류변성기 비교측정 장치의 현장 평가기술 (On-Site Evaluation Technique of Current Transformer Comparator System)

  • 정재갑;이상화;권성원;강전홍;김명수
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.926-932
    • /
    • 2007
  • A recently developed methods for on-site calibration of the current transformer (CT) comparator system have been reviewed in the paper. The method utilizes several traveling standards, which consist of the CT, non-reactive standard resistors, wide ratio error CT, and shunt resistors. The traveling CT is used for absolute evaluation of a standard CT belonging to industry. The non-reactive standard resistors and a wide ratio error CT are used for the linearity check of errors in the current comparator. The shunt resistors are used for evaluation of CT burden of industry.

66kV급 전압변성기 비교측정 장치의 현장 평가설비 구축 (Construction of On-Site Calibration Facilities of 66 kV Voltage Transformer Comparator System)

  • 정재갑;이상화;권성원;김명수
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1268-1274
    • /
    • 2007
  • A recently developed methods for the on-site calibration of the voltage transformer (VT) comparator system have been reviewed in the paper. The method utilizes the several traveling standards consisting of the VT, the non-reactive standard resistors, the wide ratio error VT, and the decade resistors. The VT is used for the absolute evaluation of a standard VT belonging to the industry. The non-reactive standard resistor and wide ratio error VT are used for the linearity check of errors in the voltage comparator of the industry. The decade resistors are used for evaluation of a VT burden of the industry.

마찰감쇠기가 설치된 비선형 단자유도 건물의 등가감쇠비 (Equivalent Damping Ratio of the Inelastic SDOF Structures with Friction Damper)

  • 김형섭;민경원;이상현;박지훈;문병욱
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.492-499
    • /
    • 2004
  • The purpose of this paper is to present a design procedure of coulomb friction dampers for controlling elastic and inelastic responses of building structures. The equivalent damping and frequency increased by the friction damper are estimated using ATC-40 and ATC-55 procedures which provide equivalent linear system for bilinear one, and then a design formula to achieve target performance response level by friction damper is presented. It is identified that there exists error between the responses obtained by this formula and by performing nonlinear analysis and the features of the error vary according to the hardening ratio, yield strength ratio, and structural period. Equations for compensating this er개r are reposed based on the least square method, and the results from numerical analyses indicate that the error is significantly reduced, and the proposed formula can be used without much error for designing coulomb friction damper for retrofitting a structure showing elastic or inelastic behavior.

  • PDF

길쌈부호를 사용한 Embedded DPCM 방식에 관한 연구 (A Study on an Embedded DPCM with Convolutional Coding)

  • 임종수;이상곤;문상재
    • 전자공학회논문지A
    • /
    • 제28A권1호
    • /
    • pp.1-7
    • /
    • 1991
  • Degradation of communication quality is due to transmission error rather than quantization noise when DPCM signal is transmitted over a heavily noise channel. The communication quality can be improved by employing an error correcting code to the DPCM signal transmission over such a channel. We considered both quantization noise and transmission error simultaneously in evaluating the signal to noise ratio. To efficiently improve the signal to noise ratio, we analyze the unequal symbol error probability of convolutional code, and encoded to more protect significant symbols from channel errors than least ones, so that the signal to noise ratio is improved. We derived related formulas and also made computer simulations.

  • PDF

평면 음향 홀로그래피에서 센서간 특성 차이와 측정 위치의 부정확성에 의한 음압 추정 오차의 정량화 (Quantification of Acoustic Pressure Estimation Error due to Sensor and Position Mismatch in Planar Acoustic Holography)

  • 남경욱;김양한
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1023-1029
    • /
    • 1998
  • When one attempts to construct a hologram. one finds that there are many sources of measurement errors. These errors are even amplified if one predicts the pressures close to the sources. The pressure estimation errors depend on the following parameters: the measurement spacing on the hologram plane. the prediction spacing on the prediction plane. and the distance between the hologram and the prediction plane. This raper analyzes quantitatively the errors when these are distributed irregularly on the hologram plane The sensor mismatch and inaccurate measurement location. position mismatch. are mainly addressed. In these cases. one can assume that the measurement is a sample of many measurement events. The bias and random error are derived theoretically. Then the relationship between the random error amplification ratio and the parameters mentioned above is examined quantitatively in terms of energy.

  • PDF

구형 음향 홀로그래피에서 측정위치 부정확성에 의한 음압 추정 오차의 정량화 (Quantification of Acoustic Pressure Estimation Error due to Sensor Position Mismatch in Spherical Acoustic Holography)

  • 이승하;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1325-1328
    • /
    • 2007
  • When we visualize the sound field radiated from a spherical sound source, spherical acoustic holography is proper among acoustic holography methods. However, there are measurement errors due to sensor position mismatch, sensor mismatch, directivity of sensor, and background noise. These errors are amplified if one predicts the pressures close to the sources: backward prediction. The goal of this paper is to quantitatively examine the effects of the error due to sensor position mismatch on acoustic pressure estimation. This paper deals with the cases of which the measurement deviations are distributed irregularly on the hologram plane. In such cases, one can assume that the measurement is a sample of many measurement events, and the cause of the measurement error is white noise on the hologram plane. Then the bias and random error are derived mathematically. In the results, it is found that the random error is important in the backward prediction. The relationship between the random error amplification ratio and the measurement parameters is derived quantitatively in terms of their energies.

  • PDF

현장여건에 따른 터빈 유량계와 오리피스 유량계의 정확도 비교 (A Comparison of Accuracy Between a Turbine and an Orifice Meter in the Field)

  • 안승희;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.97-105
    • /
    • 1999
  • Orifice flow meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice flow meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested in the standard manuals, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the more the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

전류변성기의 비오차와 위상오차의 절대 평가 기술 (Absolute Evaluation Method to Obtain Ratio Error and Phase Displacement of Current Transformers)

  • 김윤형;정재갑;한상길;구경완;한상옥
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.153-159
    • /
    • 2008
  • We have developed an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) without any precise standard CT by measuring four parameters in a CT equivalent circuit. The excitation admittance in the CT equivalent circuit can be obtained by employing standard resistors with negligible reactive component. The secondary leakage impedance in the CT equivalent circuit can be measured using a universal impedance bridge. The method was applied to CTs under test with the wide current ratios in the range of 5 A / 5 A - 5,000 A / 5 A and 5 A / 1 A - 5,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Canada using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

항만부진동 해석을 위한 적정 유한요소 크기에 대한 소고 (A Note on the Proper Size of a Finite Element for Analysis of Harbor Resonance Problems)

  • 정원무;박우선
    • 한국해안해양공학회지
    • /
    • 제14권1호
    • /
    • pp.86-93
    • /
    • 2002
  • 항만부진등 해석에 사용되는 유한요소의 적정 크기를 검토하기 위해 완전개방 직사각형 항만에 대해서 다양한 크기의 요소를 사용한 수치실험을 실시하였다. 수치실험 결과, 공진주기와 증폭비의 허용 오차율을 모두 2%로 하는 경우 파장당 9개, 1%로 하는 경우 12개의 요소가 필요한 것으로 나타났다. 또한, 요소 수의 증가에 따라 공진주기의 오차율은 선형적으로, 증폭비의 오차는 진동하면서 감소하였으며, 요소 수를 9개보다 적게 하는 경우 증폭비의 오차가 상대적으로 크게 증가하였다