• Title/Summary/Keyword: Ratio Analysis

Search Result 21,311, Processing Time 0.043 seconds

Effects of damping ratio on dynamic increase factor in progressive collapse

  • Mashhadi, Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • v.22 no.3
    • /
    • pp.677-690
    • /
    • 2016
  • In this paper, the effect of damping ratio on nonlinear dynamic analysis response and dynamic increase factor (DIF) in nonlinear static analysis of structures against column removal are investigated and a modified empirical DIF is presented. To this end, series of low and mid-rise moment frame structures with different span lengths and number of storeys are designed and the effect of damping ratio in DIF is investigated, performing several nonlinear static and dynamic analyses. For each damping ratio, a nonlinear dynamic analysis and a step by step nonlinear static analysis are carried out and the modified empirical DIF formulas are derived. The results of the analysis reveal that DIF is decreased with increasing damping ratio. Finally, an empirical formula is recommended that relates to damping ratio. Therefore, the new modified DIF can be used with nonlinear static analysis instead of nonlinear dynamic analysis to assess the progressive collapse potential of moment frame buildings with different damping ratios.

Evaluation of J-R Curve for Aluminum 5083 Alloy Weldment by Load Ratio Analysis (Load Ratio 해석에 의한 알루미늄 5083 합금 용접부의 J-R곡선 평가)

  • 윤한기;김연겸
    • Journal of Welding and Joining
    • /
    • v.15 no.4
    • /
    • pp.178-186
    • /
    • 1997
  • The purpose of this study is to evaluate the J-R curve characteristics for the 5083 aluminum alloy weldment by the load ratio analysis. The results of the load ratio analysis are compared with those of the J-R curve which are obtained by the ASTM unloading compliance method. The crack length calculated by the load ratio analysis is agrees well with the measured final crack length. The slope of the exponential J-R curve estimated by the load ratio analysis is slightly smaller than that by the ASTM unloading compliance method. The exponential correlation of the J-R curve for the 5083 aluminum alloy base metal by the load ratio analysis is J = 93.88 ${\Delta}{\alpha}^{0.375}$. That for the weld metal and HAZ is J = 69.87 ${\Delta}{\alpha}^{0.389}$ and J = 70.59 ${\Delta}{\alpha}^{0.359}$ respectively. The J-R curve obtained by the ASTM unloading compliance method is overpredicted and should be offsetted due to the initial negative crack. On the other hand, the load ratio analysis method can evaluate the J-R curve by only load displacement curve without particular crack measurement equipment.

  • PDF

Validity Examination on Evaluation of J-R Curve in the Nuclear Reactor Pressure Vessel Steels and Aluminum Alloys by Load Ratio Analysis (원자로 압력용기강 및 Al 합금재의 J-R곡선평가시 Load Ratio 해석의 유효성 검토)

  • Yoon, H.K.;Woo, D.H.;Kim, Y.K.;Cha, G.J.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.80-90
    • /
    • 1997
  • The purpose of this study is to evaluate the validity examination of the J-R curve characteristics for the nuclear reactor pressure vessel steels and Al alloys by the load ratio analysis. The results of the load ratio analysis are compared with those of the J-R curve which are obtained by the ASTM unloading compliance method. The crack length calculated by the load ratio analysis is agree well with the measured final crack length. The slope of the exponential J-R curve estimated by the load ratio analysis is slightly smaller than that by the ASTM unloading compliance method. The J-R curve obtained by the ASTM unloading compliance method is over-predicted and should be offsetted due to the initial negative crack. On the other hand, the load ratio analysis method can evaluate the J-R curve by only load-displacement curve without particular crack measurement equipment.

  • PDF

Probabilistic Analysis of Liquefaction Cyclic Stress Ratio Considering Soil Variability (지반변동성을 고려한 액상화 진동전단응력비의 확률론적 해석)

  • Heo, Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.95-101
    • /
    • 2018
  • The objective of this study is to evaluate the liquefaction cyclic shear stress ratio considering the soil uncertainty. In this study, the probabilistic ground response analysis and the cyclic shear stress ratio analysis for the liquefaction potential evaluation are performed considering the soil variability. The statistical properties of input ground parameters were analyzed to investigate the parameters affecting the seismic response analysis. The Probabilistic analysis was carried out by Monte Carlo Simulation method. The ground response analysis was performed considering the soil variability and the probability distribution characteristics of the ground acceleration. The probability distribution of the peak ground acceleration by seismic characteristics was presented. The differences of liquefaction shear stress ratio results according to soil variability were compared and analyzed. The maximum acceleration of the ground by the deterministic method was analyzed to be overestimation of the ground amplification phenomenon. Also, the shear stress ratio was overestimated.

An Analysis on the Management Situation of a Hansalim Consumer Cooperatives (A생협에 대한 경영성과 분석)

  • Kim, Ho
    • Korean Journal of Organic Agriculture
    • /
    • v.28 no.1
    • /
    • pp.59-68
    • /
    • 2020
  • This study analyzed and suggested management situations and improving issues on a consumer cooperatives which has supplied environmentally friendly agricultural products from the year 2002. Indices of management analysis are stability ratio, activity ratio and profitability ratio. Management Stability ratio indices are debt ratio, net worth ratio, fixed ratio and current ratio. Management activity ratio ones include fixed assets turnover and net worth turnover. And profitability ratio is showed through return on investment, net return on sales and return on equity. In order to analyze these indices, financial statements after the closing entires are used each year.

Efficiency evaluation of water leakage management methods in local small and medium cities (지방중소도시의 누수관리방법에 대한 효율성 평가)

  • Hwang, Jinsoo;Choi, Taeho;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.2
    • /
    • pp.121-133
    • /
    • 2021
  • This study set up the estimates of leakage management efficiency evaluation and leakage management goal that could be used in local water distribution networks efficiency business and modernization business. The data were analyzed using data envelopment analysis and multiple regression analysis. To this end, with leakage management input indices concerning leakage reduction activities (e.g., aged pipe replacement, water meter replacement, leakage restoration, and leakage detection) and leakage management calculation indices (e.g., the increase of revenue water ratio and the reduction of leakage ratio), the data on 22 K-water consignment local water supply systems were analyzed for the years from 2004 through 2018. Using the results of efficiency analysis by data envelopment analysis, the other DMUs (Decision Making Unit) benchmarked the DMU with the highest efficiency to maximize the leakage management efficiency for all DMUs. Through this, leakage management goal estimates were drawn with the input indices of four leakage reduction activities and calculation indices of the increase of revenue water ratio and the reduction of leakage ratio by multiple regression analysis for each group based on the revenue water ratio and leakage ratio. The correlation coefficients of the leakage management goal estimate for the criteria for the revenue water ratio amounted to 0.553 and 0.771. The correlation coefficients of the leakage management goal estimate for the criteria for leakage ratio were 0.397 and 0.865. Accordingly, we estimated the quantity and priority of four leakage reduction activities for the target leakage ratio and revenue water ratio.

Evaluation on J-R Curve of 5083 aluminum Alloy Weldment by Load Ratio analysis (Load Ratio 해석에 의한 Al 5083 알루미늄합금 용접부의 J-R곡선 평가)

  • 윤한기;김연겸;우대호
    • Proceedings of the KWS Conference
    • /
    • 1997.05a
    • /
    • pp.91-98
    • /
    • 1997
  • This research is to evaluate of the J-R curve characteristic in 5083 aluminum alloy weldment by utilizing the load ratio analysis. This analysis method can be evaluated the J-R curve only with load-displacement curve without any particular precision instrument equipment in CT specimen. For validity, the results of the load ratio analysis are compared with the those of the J-R curve, which are obtained by the ASTM standard unloading compliance method. The calculated crack length of the load ratio analysis is well appropriate that the measured final crack length. And the J-R curve slope estimated by the load ratio analysis is slightly smaller than that by the ASTM unloading compliance method.

  • PDF

A Study on Glazing Ratio of Certified Green Building Apartment (국내 친환경 아파트의 채광창 면적비에 관한 연구)

  • Kim, Sang-Bum;Park, Jong-Hoon;Yang, Byoung-E
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.95-100
    • /
    • 2010
  • Buildings receive solar radiation through windows and the solar radiation helps to save heating energy in winter. Therefore the bigger the glazing ratio is, the larger the amount of solar radiation we can receive. In this study we analysed the glazing ratio of Certified Green Building Apartments. And we verified whether the glazing ratio reflects energy saving through accepting solar radiation with correlation analysis. For glazing ratio analysis, we selected 116 apartment buildings of 19 apartment complexes that certified in 2008-2009 and took pictures of outside windows of the buildings. After that, we analysed the building's glazing ratio with 4 azimuth and checked distinction of the glazing ratio between 6 coupled azimuths. And we analysed the correlation between importance order of azimuth for energy saving and the glazing ratio change with the azimuth. The analysis showed that the glazing ratio does not reflect energy saving through accepting solar radiation.

Crack Damages in Exterior Wall Structures of Korean High-Rise Apartment Buildings Based on Nonlinear Finite Element Analysis (비선형 유한요소해석 기반 국내 고층아파트 외벽구조의 균열손상 특성 분석)

  • Kim, Sung Hyun;Mo, Sang Yeong;Kim, Si Hyun;Choi, Kyoung Kyu;Kang, Su Min
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.47-57
    • /
    • 2024
  • Recently, in newly constructed apartment buildings, the exterior wall structures have been characterized by thinness, having various openings, and a significantly low reinforcement ratio. In this study, a nonlinear finite element analysis was performed to investigate the crack damage characteristics of the exterior wall structure. The limited analysis models for a 10-story exterior wall were constructed based on the prototype apartment building, and nonlinear static analysis (push-over analysis) was performed. Based on the finite element (FE) analysis model, the parametric study was conducted to investigate the effects of various design parameters on the strength and crack width of the exterior walls. As the parameters, the vertical reinforcement ratio and horizontal reinforcement ratio of the wall, as well as the uniformly distributed longitudinal reinforcement ratio and shear reinforcement ratio of the connection beam, were addressed. The analysis results showed that the strength and deformation capacity of the prototype exterior walls were limited by the failure of the connection beam prior to the flexural yielding of the walls. Thus, the increase of wall reinforcement limitedly affected the failure modes, peak strengths, and crack damages. On the other hand, when the reinforcement ratio of the connection beams was increased, the peak strength was increased due to the increase in the load-carrying capacity of the connection beams. Further, the crack damage index decreased as the reinforcement ratio of the connection beam increased. In particular, it was more effective to increase the uniformly distributed longitudinal reinforcement ratio in the connection beams to decrease the crack damage of the coupling beams, regardless of the type of the prototype exterior walls.

The Sensitivity Analysis of Parameters of Urban Runoff Models due to Variations of Basin Characteristics (I) - Development of Sensitivity Analysis Method - (유역특성 변화에 따른 도시유출모형의 매개변수 민감도분석(I) -민감도분석방법의 개발-)

  • Seo, Gyu-U;Jo, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.3
    • /
    • pp.243-252
    • /
    • 1998
  • In this study, the new dimensionless values were defined and proposed to determine the parameters of urban runoff models based on the relative sensitivity analysis. Also, the sensitivity characteristics of each parameter were investigate. In order to analyze the parameter sensitivities of each model, total runoff ratio, peak runoff ratio, runoff sensitivity ratio, sensitivity ratio of total runoff, and sensitivity ratio of peak runoff were defined. $$Total\;runoff\;ratio(Q_{TR})\;=\;\frac{Total\;runoff\;of\;corresponding\;step}{Maximum\;total\;runoff}$$$$Peak\;runoff\;ratio(Q_{PR})\;=\;\frac{Peak\;runoff\;of\;corresponding\;step}{Maximum\;peak\;runoff}$$$$Runoff\;sensitivity\;ratio(Q_{SR})\;=\;\frac{Q_{TR}}{Q_{PR}}$$ And for estimation of sensitivity ratios based on the scale of basin area, rainfall distributions and rainfall durations in ILLUDAS & SWMM, the reasonable ranges of parameters were proposed.

  • PDF