• 제목/요약/키워드: Rating system

검색결과 1,411건 처리시간 0.027초

주변압기 용량증설에 따른 배전계통의 차단기 정격차단전류 검토 (An Investigation of the nominal rating current for breakers in distribution system due to the increased capacity of power transformer)

  • 조성수;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.396-397
    • /
    • 2008
  • In order to evaluate the nominal rating of breakers in distribution system due to the increased capacity of power transformer from 60 to 100 MVA, the fault currents are calculated in the condition of 3-phase fault and single line-to-ground fault. Consequently, under the condition of the parallel operation of transformers the fault currents were exceed the nominal rating current of breakers in some areas.

  • PDF

쳬계신뢰성에 기초한 사장교의 안전도 및 내하력 평가 (System Reliability-Based Safety and Capacity Evaluation of Cable-Stayed Bridges)

  • 조효남;이승재;임종권;김보헌
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.105-112
    • /
    • 1996
  • A practical approach for the assessment of system reliability-based safety and load carring capacity under vehicle traffics is proposed for the realistic evaluation of safety and rating of cable-stayed bridges. A partial event tree analysis model incorporating major critical failure paths is suggested as a practical tool for the system reliability analysis and system reliability-based capacity rating. The proposed approach for the system reliability analysis and system reliability-based rating is applied to the safety assessment of the Jindo Bridge which is one of two existing cable-stayed bridges in Korea. The results of analyses at the system level based on the system reliability are compared with those at the element level.

  • PDF

건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가 (A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating)

  • 장철용;김치훈;안병립;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.1-6
    • /
    • 2010
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend.In addition, the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1) The insulation performance of super window system is $1.44\;W/m^2^{\circ}C$ 2) Super Window compared to a normal window reduce heating energy requirements have been 5.3% 3) Compared to a normal window, Super window savings rate was 4.1% lower 4) Building energy efficiency rating was up to 1 rating from 2 rating.

다변량분석을 이용한 터널에서의 효율적인 암반분류에 관한 연구 (A Study of Efficient Rock Mass Rating for Tunnel Using Multivariate Analysis)

  • 위용곤;노상림;윤지선
    • 한국터널지하공간학회 논문집
    • /
    • 제2권2호
    • /
    • pp.41-49
    • /
    • 2000
  • 지하 터널 굴착 등의 암반 공학적 문제에 있어서 암반분류가 널리 적용되고 있다. 하지만, 조사 방법이 체계화되어 있지 않아서 터널 지질 전문가라 할지라도 암반분류에 어려움이 많은 문제점을 가지고 있다. 본 연구에서는 다변량분석을 이용하여 객관적이고 사용하기 간편한 암반분류법을 제시하였다. RMR 요소는 RQD, 절리상태, 지하수, 강도, 보정, 절리간격 순으로 중요도가 결정되었으며, 각각의 단계에서 RMR에 관한 최적의 다중회귀모형식을 제시하였다.

  • PDF

공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석 (Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings)

  • 이한솔;김서훈;김종훈;김준태;장철용
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

Dynamic Thermal Rating of Overhead Transmission Lines Based on GRAPES Numerical Weather Forecast

  • Yan, Hongbo;Wang, Yanling;Zhou, Xiaofeng;Liang, Likai;Yin, Zhijun;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • 제15권4호
    • /
    • pp.724-736
    • /
    • 2019
  • Dynamic thermal rating technology can effectively improve the thermal load capacity of transmission lines. However, its availability is limited by the quantity and high cost of the hardware facilities. This paper proposes a new dynamic thermal rating technology based on global/regional assimilation and prediction system (GRAPES) and geographic information system (GIS). The paper will also explore the method of obtaining any point meteorological data along the transmission line by using GRAPES and GIS, and provide the strategy of extracting and decoding meteorological data. In this paper, the accuracy of numerical weather prediction was verified from the perspective of time and space. Also, the 750-kV transmission line in Shaanxi Province is considered as an example to analyze. The results of the study indicate that dynamic thermal rating based on GRAPES and GIS can fully excavate the line power potential without additional cost on hardware, which saves a lot of investment.

동력전달용 베벨기어의 강도평가 시스템 개발 연구 (Development of Rating Systems for Power Transmission Bevel Gears)

  • 정태형;지중조;변준형
    • 한국정밀공학회지
    • /
    • 제12권7호
    • /
    • pp.66-73
    • /
    • 1995
  • Rating systems of bevel gears(straight, spiral, and zerol bevel gears) which are commonly used as power transmission devices for non-papallel axes are developed on the personal computer, which analyze and/or evaluate the gear design and the service performance at the point of view of strength and durability. The typical considerations of the ratings are the bending strength, the surface durability, and the scoring resistance. The ratings are carried out using the reliable standards of AGMA & Gleason Works. Therefore, the system is built so that the variables or factors considered differently in those standards and the strength, dura- bility, and scoring partially in Gleason are appraised seperately by each method, and a series of the estimation processes is integrated into the system so as to compare each result. The developed rating systems can be used in the initial stage of gear design process, and also a better design can be performed by the evaluation of the initial design at the view point of gear strength and durability. Additionally, it is useful for the trouble-shooting of bevel gear system and to the purpose of introducing the methods for maintaining design strength in service, with appraising the gear strength after design or with appraising the influencing factor as a whole. Therefore, this rating systems can help the aim of design automation of bevel gears.

  • PDF

Differences among Credit Rating Agencies and the Information Environment

  • PARK, Hyunjun;YOO, Youngtae
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제6권2호
    • /
    • pp.25-32
    • /
    • 2019
  • In the Korean capital market, there are three credit rating agencies. Potential credit ratings based on credibility in the financial market are calculated independently for each rating agency. It often happens that despite the fact that the grades of the rating agencies are the same and have the same rating system, their actual ratings are different, even for the same firm. In such circumstances, investors may wonder why. In this study, we assume that the cause is the information environment in which the company operates. The credit ratings of rating agencies are mainly classified into bonds or commercial papers. The bonds are rated primarily for long-term of three years or more, and commercial papers specify ratings for less than one year. The information environment to be verified in this study was observed with a commercial paper. Under the assumption the larger the analyst following is, the more transparent is the information environment, we analyzed the influence of the number of analysts following on the degree to which ratings conflicted among credit rating agencies. The results of our analysis confirmed that opinion conflict among credit rating agencies is clearly reduced for companies with good information environments.

추천 시스템의 예측 정확도 향상을 위한 고객 평가정보의 신뢰도 활용법 (Applying Rating Score's Reliability of Customers to Enhance Prediction Accuracy in Recommender System)

  • 최준연;이석기;조영빈
    • 한국콘텐츠학회논문지
    • /
    • 제13권7호
    • /
    • pp.379-385
    • /
    • 2013
  • 인터넷에서 고객들에 의해 생성된 평가정보는 해당 상품에 대한 고객별 선호도 정보로도 간주할 수 있기 때문에 개인화 추천을 위한 고객 프로필 생성에 효과적으로 활용될 수 있다. 하지만, 온라인에서의 상품평가는 누구나 작성할 수 있고, 왜곡된 목적으로 가지고 평가 행위를 하는 경우도 많아 평가정보의 신뢰도 편차가 크다. 따라서 본 연구에서는 상품에 부여된 평가정보 자체의 신뢰도를 측정하고 이를 추천시스템의 고객 프로필 생성 과정에 선별적으로 반영하는 방법론을 제안하고자 한다. 몇몇 추천 시스템 관련 연구에서 평가정보 작성자 수준에서 신뢰도를 측정하고 이를 활용하려 했던 것과 달리 본 연구에서는 개별 평가 정보 수준에서 신뢰도를 측정한다. 실험 결과 신뢰도가 일정수준 이상의 신뢰도를 갖는 평가정보만을 선별하여 고객 프로필을 생성할 경우 추천 시스템의 선호도 예측 정확도가 향상되는 것으로 나타났다.

VAV 및 VWV시스템 적용에 따른 업무용 건축물의 에너지저감에 관한 연구 (A Study of applying VAV and VWV System to reduce Energy Consumption of Office building)

  • 송지용;홍원화;김지연;박효순
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.57-63
    • /
    • 2013
  • Building Energy Efficiency Rating system was enforced in 2001 to enhance spreading high-energy performance and saving buildings. It was only for the new apartments, but expanded to new office buildings in 2010, and moreover, government offices require 1st grade of Building Energy Efficiency Rating system. Green Building Act, which is established to reduce the emissivity of carbon dioxide by reducing building energy consumption, will be enforced in 2013, and new apartments and office buildings will be subjected to it. Henceforward, it will extend to other types of buildings and will be phased in. In general, pumps and fans consume approximately half of the air-conditioning energy consumption, and about a quarter of the total building energy consumption when office buildings have total floor area of more than 10000 square meters. This study analyzed the energy demand when applying VAV(Variable Air Volume) and VWV(Variable Water Volume) System to reduce energy returns of the pumps and the fans by ECO2, which is a computer simulation program used for Building Energy Efficiency Rating system.