• Title/Summary/Keyword: Rated current line

Search Result 55, Processing Time 0.023 seconds

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.

Voltage Applicable to $Au/YBa_2Cu3O_7$ Meander Lines ($Au/YBa_2Cu3O_7$ 곡선에 인가가능 전압)

  • Kim, H.R.;Yim, S.W.;Yu, S.D.;Park, C.R.;Yang, S.E.;Kim, W.S.;Hyun, O.B.
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.62-67
    • /
    • 2010
  • We investigated the voltage applicable to $Au/YBa_2Cu3O_7$ (YBCO) meander lines. The meander line was fabricated by patterning Au/YBCO thin films grown on sapphire substrates by photolithography. It was subjected to simulated AC fault currents, and the resistance was measured and analyzed. The samples were immersed in liquid nitrogen during the experiment for effective cooling. The voltage applicable to the meander lines depended on the fault duration. Dependence was strong at short fault durations, and weak at long durations. When the voltage was plotted as a function of the fault duration on a log-log scale, data fell more or less on straight lines for all meander lines. In other words, the voltage applicable to Au/YBCO meander lines on sapphire substrates was inversely proportional to $t^b$, where t is the fault duration and b ranges from 0.4 to 0.5. The results were analyzed quantitatively with the concept of heat balance. Under adiabatic condition, the voltage is to be inversely proportional to $t^{0.5}$ for all samples. Less value of b for some samples is thought to be due to cooling of the samples by liquid nitrogen.

Development of electric safety control system for incapable operation of ELB and MCB using the low voltage distribution line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 전기안전 제어장치 개발)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young;Kim, Hyo-Jin;Baek, Seong-Hyun;Choi, Byung-Seub
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.371-372
    • /
    • 2007
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is Earth Leakage Circuit Breaker(ELB) and Molded_case Circuit Breaker (MCB), of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

A Study on the Application of Graphic Metaphor to the Web Interface - concentrating on the homework supporting domains for higher classes in the elementary schools- (웹 인터페이스에서의 그래픽 메타포 활용에 관한 연구 -초등학교 고학년 숙제도우미 영역을 중심으로-)

  • 이미경;김혜경
    • Archives of design research
    • /
    • v.16 no.4
    • /
    • pp.385-394
    • /
    • 2003
  • An investigation by KRNIC (Korea Network Information Center) on the real state of usage of internet has shown that 96.9% of children investigated had experiences of using internet. Especially the firstly ranked item that had been answered by children as a necessity of internet was 'Studying to solve tasks' rated by 83.9%. As seen from the research result, the need as a homework sonics is actually so dominant that it cannot be ignored when considering the profitability at the area of education contents, but any profound research has not been accomplished yet. Internet has been positioned as a more effective and fruitful learning tool, and also all activities done by users for exploring informations and choosing learning items under the on-line circumstances are based on the successive mutual reactions between users and computers. Up to now much of the web based learning circumstances has been introducing the User Interface using metaphor, and the same is found dominantly from the sites for children. But in spite of the availability of metaphor mentioned above the current status is much lack of profound researches about metaphor interface; and what is more, in the case of the site for elementary school students the gap of the ability recognizing metaphor is very large between lower classes and higher classes according to the degree of mental growth but that is used to be simply ignored, then a common concept is adapted to interface for all grades of classes and moreover for infant and kindergarten without any objections. Based on foregoing problems this research has put the main focus on the groping and presenting desirable directions on the prospect design of interface for children-oriented sites by analyzing the status of practical usage of metaphor interface in the field of the sites for children-oriented learning sites with concentration upon homework supporting domains.

  • PDF