• Title/Summary/Keyword: Rated Load

Search Result 315, Processing Time 0.044 seconds

The Study on the Active Power Filter in Unbalanced Load (불평형 부하에서의 능동필터에 관한 연구)

  • Choi, See-Young;Lee, Woo-Cheol;Lee, Taeck-Kie;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.3
    • /
    • pp.130-140
    • /
    • 2001
  • This paper presents the performance of a parallel active power filter(PT) system in unbalanced load condition. The unbalanced load leads to negative sequence of current, and makes 120Hz ripple in the DC-link voltage forcing large capacitance and increases the rating of APF. thus, the separation of negative sequence is performed in synchronous reference frame and controlled to flow into supply network. The validity of the scheme is investigated through simulation and the experimental results for a prototype active power filter system rated at 10kVA.

  • PDF

Auto-Diagnosis for Stator Winding Faults Using Distortion Ratio of Park's Vector Pattern (Park's 벡터 패턴의 왜곡률을 이용한 고정자 권선 고장 자동진단)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Yang, Chul-Oh
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.160-163
    • /
    • 2008
  • In this paper, an auto-diagnosis method of the stator winding fault for small induction motor is suggested. 3-phase stator currents are sampled, filtered, and transformed with Park's vector transformation. After then Park's vector patterns are obtained. To detect the stator winding fault automatically, a distortion ratio is newly defined and compared with the one of healthy motor, and the threshold levels of distortion ratio are suggested. The 2-turn, 4-turn, 8-turn winding fault are tested with no load, 25%, 50%, 75%, and 100% rated load. The distortion ratio of the Park's vector patterns are increased as the increase of the faulted turns, but are same as the increase of the load.

A Study on the Improvement of Performance and Stability of Induction Heating System (유도 가열 시스템의 성능과 안정성 향상에 관한 연구)

  • Gwon, Yeong-Seop;Yu, Sang-Bong;Hyeon, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.417-425
    • /
    • 1999
  • This paper presents an effective control scheme with the voltage-fed half-bridge series resonant inverter for induction heating system, which is based upon a load-adaptive tuned frequency tracking control strategy using PLL(Phase Locked Loop) and its peripheral control circuits. The proposed control strategy ensures a stable operation characteristics of overall inverter system and ZVS(Zero Voltage Switching) irrespective of sensitive load parameter variations, specially in the non-magnetic materials as well as power regulation. The detail operation principle and the characteristics of inverter system with the proposed control scheme are described and its validity is verified by the simulation and the experimental results for a prototype induction cooking system rated at 1.2kW.

  • PDF

A simulation test of lone rejection for steam turbine generator in nuclear power plant (원자력발전소 증기터빈 발전기의 부하차단 모의시험)

  • Choi, In-Kyu;Jeong, Tae-Woon;Lee, Ki-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2301-2303
    • /
    • 2003
  • A steam turnine in thermal/nuclear power plant drives generator and maintains it at rated speed using high temperature and high pressure steam energy. After synchronization in parallel with the power system, generator output increases according as the governor, that is the controller, increases steam flow into turbine. By the way, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is to limit the speed to its overspeed trip setpoint by stopping the steam flow as soon as possible, the test of which is called load rejection test. It is introduced in this paper for a simulation test of generator load rejection to be implemented on the turbine governor in a 600MW nuclear power plant before its startup.

  • PDF

Automatic Diagnosis for Stator Winding Faults Using Distortion Ratio (왜곡률을 이용한 고정자 권선고장 자동진단)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Yang, Chul-Oh
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.358-360
    • /
    • 2007
  • In this paper, an auto-diagnosis method of the stator winding fault for small induction motor is suggested. 3-phase stator currents are sampled, filtered, and transformed with Park's vector transformation. After then Park's vector patterns are obtained. To detect the stator winding fault automatically, a distortion ratio (id/iq) is newly defined and compared with the one of healthy motor, and the threshold levels are suggested. The 2-turn, 4-turn, 8-turn winding fault are tested with no load, 25%, 50%, 75%, and 100% rated load. The distortion ratio of the Park's vector patterns are increased as the increase of the faulted turns, but are same as the increase of the load.

  • PDF

The Control of load Commutated Current Source Inverter for Induction Motor Drive (유도전동기(誘導電動機) 구동(驅動)을 위한 부하전류식(負荷轉流式) 전류형(電流型) 인버터의 제어(制御))

  • Chung, Y.T.;Sim, J.M.;Lee, S.Y.;Soh, Y.C.;Lee, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.255-257
    • /
    • 1994
  • The V/F slip frequency constant control methods are used for driving induction motor with load commutated current source inverter, that is. constant V/F and slip frequency driving is used to load commutate the inverter below the critical frequency, while constant voltage and variable frequency and slip frequency driving are used in above the critical region. In order to applicate the load commutated current source inverter to the general use, speed control range of induction noter is selected to two times at rated frequency. Therefore, economical application is possible because of the maximum reduction of the condenser of the inverter output port. The use of the proposed force commutated circuit improves the false operation of force commutated circuit and inverter commutation failure which are produced by the influence of the lower-order harmonics of the conventional load commutated current source inverter at starting.

  • PDF

New control strategy of Static Inverter for the Light Rail Transit (경량전철용 보조전원장치의 새로운 제어 기법)

  • Lee, Eun-Kyu;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.190-193
    • /
    • 2003
  • This paper Proposes 40 [KVA] rated SIV(Static Inverter) system for Light Rail Transit. The SIV Provide power of a fluorescent light in the car, Air-conditioner. and other equipments. To control output voltage it is used voltage control loop for constant voltage control and simultaneously used current control loop for instantaneous control at load changing. The Performance of SIV system will be verified by experimental results.

  • PDF

Efficiency Improvement of VVCF-Induction Motor Drives with Counter EMF Estimation (역기전력 추정에 의한 VVCF-유도전동기 시스템의 운전효율개선)

  • Moon, Sang-Chun;Lee, Seung-Chul;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.271-273
    • /
    • 1995
  • This paper proposes the efficiency improvement method of vvcf-induction motor drives, which operates always at rated speed, regardless of load conditions, with counter emf estimation. The counter emf is estimated by detecting the fundamental component of motor input current, which is employed in speed control algorithm through the comparison with the actual counter emf during the nonconduction interval. The input power reduction by speed control is confirmed through simulations and experimental results.

  • PDF

Development of Static Inverter for the Light Rail Transit (경량전철용 보조전원장치의 개발)

  • 이은규;염상구;최재호
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.522-527
    • /
    • 2002
  • This paper proposes 40 [KVA] rated SW(Static Inverter) system for Light Rail Transit. The SIV provide power of a fluorescent light in the car, Air-conditioner, and other equipments. To control output voltage it is used voltage control loop for constant voltage control and simultaneously used current control loop for instantaneous control at load changing. The performance of SW system will be verified by experimental results.

  • PDF

A method for inductor design to improve efficiency in PFC boost converter

  • Liang, Dong;Kang, Woong-Jae;Shin, Hwi-Beom
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.1-2
    • /
    • 2017
  • In this paper a method is proposed to optimize the inductor design of PFC boost converter with maximum efficiency at rated load. The variables of switching frequency, the number of turns, core size and permeability are selected to improve the efficiency. The experimental result shows the proposed inductor design method can lead a higher efficiency when compared with the typical inductor design method.

  • PDF