• Title/Summary/Keyword: Rate of penetration

Search Result 868, Processing Time 0.031 seconds

Effect of Wet Curing Duration on Long-Term Performance of Concrete in Tidal Zone of Marine Environment

  • Khanzadeh-Moradllo, Mehdi;Meshkini, Mohammad H.;Eslamdoost, Ehsan;Sadati, Seyedhamed;Shekarchi, Mohammad
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.4
    • /
    • pp.487-498
    • /
    • 2015
  • A proper initial curing is a very simple and inexpensive alternative to improve concrete cover quality and accordingly extend the service life of reinforced concrete structures exposed to aggressive species. A current study investigates the effect of wet curing duration on chloride penetration in plain and blended cement concretes which subjected to tidal exposure condition in south of Iran for 5 years. The results show that wet curing extension preserves concrete against high rate of chloride penetration at early ages and decreases the difference between initial and long-term diffusion coefficients due to improvement of concrete cover quality. But, as the length of exposure period to marine environment increased the effects of initial wet curing became less pronounced. Furthermore, a relationship is developed between wet curing time and diffusion coefficient at early ages and the effect of curing length on time-to-corrosion initiation of concrete is addressed.

CT Findings of Perforation of the Stomach after Ingestion of Glacial Acetic Acid (빙초산 음독 후 발생한 위천공: CT 소견을 중심으로)

  • Kim, Hohyun;Yeom, Seok Ran;Cho, Hyun Min;Yeo, Kwang-Hee;Kim, Jae-Hun
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.16 no.2
    • /
    • pp.161-164
    • /
    • 2018
  • The ingestion of corrosive substances often leads to severe morbidity and mortality. Acids produce coagulation necrosis with a lesser degree of penetration, whereas alkalis produce liquefactive necrosis with penetration. Acetic acid is a clear, colorless organic acid with a pungent, vinegar-like odor. The ingestion of highly concentrated acetic acid (glacial acetic acid) may cause a range of complications. On the other hand, perforation of the stomach is extremely rare but it has a high mortality rate. This paper reports a case of perforation of the stomach after the ingestion of glacial acetic acid with suicidal intent in an otherwise healthy 76-year-old woman.

An experimental study on initial dispersion process of diesel fuel spray (디젤유분무의 초기분산과정에 관한 실험적 연구)

  • 허종철;구자왕;양옥룡
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.42-49
    • /
    • 1991
  • This study is to investigate the dispersion characteristics of diesel fuel spray in the initial stage of the beginning of the injection under the condition of room temperature and atmospheric pressure. It is difficult to analyse that the diesel fuel spray in diesel engine has unsteady intermittent spray. So author installed a fuel accumulator and an electromagnetic controller in order to keep the constant fuel injection rate with the time variation. With this modified fuel injection system, spray tip penetration, spray angle and initial spray development process are investigated by instantaneous photographic method. The results obtained in this study are as follows : 1) The initial shape of injection of diesel fuel spray shows the form of non-disintegrated intact core, but the formation of ligaments increasingly grows as the time increases. It can also be shown that fine droplets become disintegrated out from the ligaments. 2) The slope of spray tip penetration was changed to two different tendencies with time. The transition point of the slope is shown at the time of around between 0.09 msec and 0.4 msec from the beginning of injection. This is transition time from non-disintegrated intact core to formation of ligaments.

  • PDF

Effect of L-Menthol on the Percutaneous Absorption of Ketorolac Tromethamine Across Human Cadaver Skin (사람 카다베르 피부를 통한 케토롤락 트로메타민의 경피 흡수에 L-menthol이 미치는 영향)

  • Lee, Yong-Seok;Oh, Heung-Seol;Kim, Ha-Hyung;Lee, Kwang-Pyo
    • YAKHAK HOEJI
    • /
    • v.44 no.6
    • /
    • pp.595-600
    • /
    • 2000
  • Transdermal delivery of ketorolac tromethamine, a potent non-narcotic analgesic, through human cadaver skin was investigated in vitro. A mixture of ethanol/water (40/60) containing 0, 1, 3, 5, and 8 (w/v)% L-menthol were used as a vehicle and penetration enhancer respectively. The permeation of ketorolac through human cadaver skin from saturated drug solution was evaluated at $37^{\circ}C$ with modified Franz diffusion cell. The in vitro skin flux and lag time were $1.23\;{\pm}\;0.11\;{\mu}g/cm^2{\cdot}hr$ and $5.56\;{\pm}\;0.34\;hr$, respectively. The cumulative amount of penetrated ketorolac containing L-menthol in ethanol/water (40/60) binary system was increased by the following order; 3%, 5%, 8%, 1%, 0%, and the lag time was decresed by the following order; 3%, 5%, 8%, 0%, 1%. The results suggested that a potential use of 3% L-methol is an effective penetration enhancer of ketorolac tromethamine through the human cadaver skin.

  • PDF

Effect of Injector-driven Type on Spray Behavior and Fuel Atomization Characteristics (인젝터 구동 방식에 따른 분무 거동 및 분무 미립화 특성)

  • Park, Ji-Hong;Suh, Hyun-Kyu;Park, Sung-Wook;Kim, Jae-Wook;Lee, Chang-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • This study was performed to figure out spray behavior and fuel atomization characteristics of a piezo-driven injector and a solenoid-driven injector in the common-rail injection system under the same design parameters and test conditions. The process of spray injection was visualized by using the spray visualization system composed of a Nd:YAG laser and an ICCD camera. The atomization characteristics were investigated in terms of axial mean velocity, Sauter mean diameter(SMD) and droplet distributions obtained from a phase Doppler particle analyzer system. Compared with solenoid-driven injector, the piezo-driven injector has short injection delay and reaches quickly to the maximum injection value. Spray tip penetration shows some difference, however, spray angle of piezo-driven injector is wider than that of solenoid-driven injector. Sauter mean diameter of piezo-driven type injector is smaller than that of solenoid-driven type.

Characteristics of SMD and Volume Flux of Two-phase Jet Injected into Cross-flow with Various Gas-liquid Ratio and Reynolds Number (횡단 유동장의 기액비 및 레이놀즈수 변화에 따른 외부혼합형 이상유체 제트의 액적크기 및 체적유속 특성)

  • Kim, Jong-Hyun;Lee, Bong-Soo;Koo, Ja-Ye
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.75-81
    • /
    • 2009
  • A study was performed to investigate the characteristics of two-phase jet injected into subsonic cross-flow using the external mixed gas blast two-phase nozzle. The shadowgraph method was adopted for the cross-flow jet visualization and PDPA system was used to measure droplet size, velocity, and volume flux. The atomization of two-phase jet is initially determined according to gas to liquid mass flow-rate ratio and the Reynolds number of cross-flows. The highest penetration trajectories of two-phase jet injected into cross-flow are governed by the momentum ratio at subsonic cross-flow. As GLR of two-phase jet injected into cross-flow increases, the droplet size decreases and the distribution area of volume flux increases. The distribution of volume flux that influenced by the counter vortex pair at the downstream of cross-flow is symmetric in shape of horseshoe.

The Application of Piezocone Penetration Test at Inchon International Airport (인천국제공항지역의 피에조콘조사와 결과의 적용)

  • 김종국;성기광;김학중;김영웅
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.2
    • /
    • pp.115-123
    • /
    • 2000
  • Piezocone Penetration Test has been performed in the soft ground over the site preparation area at Inchon International Airport(IIA). With the pore pressure dissipation test results, the changes in the permeability and the coefficient of consolidation in clayey soil were checked and the differences of the undrained shear stength verified the soft ground improvement effect from vane test and piezocone test both before and after the improvement. From the results, thin sand seam was found and this caused a big difference in the coefficient of permeability and consolidation. The coefficient of consolidation was high in the upper marine deposit and relatively low in lower marine deposit. It was found that the reduction of void ratio by preloading resulted in the reduction of coefficient of consolidation after the ground improvement. In addition, there were some variations of undrained shear strength when the number of 15 or 18 was used as the coefficient of piezocone(Nkt). However, when the average value of undrained shear strength calculated using Nkt=10 was applied, the result indicated the similar average value with the result of vane test and the increasing rate of strength( Δsu/Δ$\sigma$≒0.38) also showed the similar distribution.

  • PDF

Design of a piezovibrocone and calibration chamber

  • Samui, Pijush;Sitharam, T.G.
    • Geomechanics and Engineering
    • /
    • v.2 no.3
    • /
    • pp.177-190
    • /
    • 2010
  • This paper presents the details of indigenous development of the piezovibrocone and calibration chamber. The developed cone has a cylindrical friction sleeve of $150cm^2$ surface area, capped with a $60^{\circ}$ apex angle conical tip of $15cm^2$ cross sectional area. It has a hydraulic shaker, coupled to the cone penetrometer with a linear displacement unit. The hydraulic shaker can produce cyclic load in different types of wave forms (sine, Hover sine, triangular, rectangular and external wave) at a range of frequency 1-10 Hz with maximum amplitude of 10 cm. The piezovibrocone can be driven at the standard rate of 2 cm/sec using a loading unit of 10 ton capacity. The calibration chamber is of size $2m{\times}2m{\times}2m$. The sides of the chamber and the top as well as the bottom portions are rigid. It has a provision to apply confining pressure (to a maximum value of $4kg/cm^2$) through the flexible rubber membrane inlined with the side walls of the calibration chamber. The preliminary static as well as dynamic cone penetration tests have been done sand in the calibration chamber. From the experimental results, an attempt has been made to classify the soil based on friction ratio ($f_R$) and the cone tip resistance ($q_c$).

Studies on the Optimal Sterilization Conditions of Red Pepper Paste Packed in Retort Pouch. (레토르트 파우치 고추장의 적정 고온 살균조건에 관한 연구)

  • Lee, Shin-Young;Choi, Kook-Chi;Lee, Sang-Kyu
    • Journal of Industrial Technology
    • /
    • v.3
    • /
    • pp.87-94
    • /
    • 1983
  • Heating characteristics of red pepper paste packed in report pouches of various thicknesses and their storage stability were investigated to determine the adequate processing conditions that good bacteriological safty and minimal quality changes could be obtained, when sterilized by using a steam-air system retort. A heat penetration into pouch-packed red pepper paste was carried out through by a conductive heat transfer, indicating a simple logarithmic heating curve, and the smaller thickness revealed the higher heat penetration rate, suggesting the possibility of high temperature-short time sterilization of red pepper paste. The processing conditions with Fo-value of 4.5 or higher were sufficient for keeping up bacterial safty, but based on C-value, better quality retention was obtained at pouch thickness of 15mm under the processing temperature of $120^{\circ}C$. Subsequent storage study revealed that the red pepper paste packed in 15mm and processed at $120^{\circ}C$ with Fo=4.5 could be held without any spoilage and overall acceptance change, when stored for 6 months at room temperature under the relative humidity of 70%. After 3 months storage in $38^{\circ}C$ under saturation humidity, overall acceptance of red pepper paste were judged not to be maintainable on the acceptable level, but it may be suggested that above the results could be kept up a desirable quality without any remarkable deterioration.

  • PDF

Theoretical Analysis of a Rotary Heat Exchanger Based on a Simplified Model (단순모델에 의한 회전형 열교환기 이론해석)

  • Son, Sung Gyun;Kim, Yongchan;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.409-417
    • /
    • 2015
  • A simplified rotary heat-exchanger model was developed with an assumption of a linear temperature distribution along the flow direction. Based on the model, the exact fluid solution and solid temperature variations were obtained and verified from a comparison with previous numerical studies. The heat transfer in the rotary heat exchanger was investigated using the theoretical solutions. The heat exchanger's effectiveness was shown to be saturated, with a rotational-speed increase that is higher than a critical value that is solely dependent on the thermal capacity of the solid matrix but independent of the fluid flow rate; the saturated value of the effectiveness was determined only by the NTU of the heat exchanger. Where the thermal diffusivity of the solid matrix is so slight that the thermal penetration depth becomes smaller than the matrix thickness, the effective thermal capacity of the solid matrix decreased according to the penetration depth.