• Title/Summary/Keyword: Rate Test

Search Result 13,585, Processing Time 0.048 seconds

Corrosion Fatigue Cracking of Low Alloy Steel in High Temperature Water

  • Lee, S.G.;Kim, I.S.;Jang, C.H.;Jeong, I.S.
    • Corrosion Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.93-97
    • /
    • 2003
  • Fatigue crack growth test or low alloy steel was performed in high temperature water. Test parameters were dissolved oxygen content. loading frequency and R-ratio ($P_{min}/P_{max}$). Since the sulfur content or the steel was low, there were no environmentally assisted cracks (EAC) in low dissolved oxygen(DO) water. At high DO, the crack growth rate at R = 0.5 tests was much increased due to environmental effects and the crack growth rate depended on loading frequency and maximized at a critical frequency. On the other hand, R = 0.7 test results showed an anomalous decrease of the crack growth rate as much different behavior from the R = 0.5. The main reason of the decrease may be related to the crack tip closure effect. All the data could be qualitatively understood by effects of oxide rupture and anion activity at crack tip.

Development of Flow Control Valves for Hot Water Distribution Manifolds (온수분배기용 유량제어밸브의 개발)

  • Kwon, Woo-Chul;Yoon, Joon-Yong;Yoo, Sun-Hak
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).

Empirical Capacity Degradation Model for a Lithium-Ion Battery Based on Various C-Rate Charging Conditions

  • Dong Hyun Kim;Juhyung Lee;Kyungseop Shin;Kwang-Bum Kim;Kyung Yoon Chung
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.414-420
    • /
    • 2024
  • Lithium-ion batteries are widely used in many applications due to their high energy density, high efficiency, and excellent cycle ability. Once an unknown Li-ion battery is reusable, it is important to measure its lifetime and state of health. The most favorable measurement method is the cycle test, which is accurate but time- and capacity-consuming. In this study, instead of a cycle test, we present an empirical model based on the C-rate test to understand the state of health of the battery in a short time. As a result, we show that the partially accelerated charge/discharge condition of the Li-ion battery is highly effective for the degradation of battery capacity, even when half of the charge/discharge conditions are the same. This observation provides a measurable method for predicting battery reuse and future capacity degradation.

Mixed double-embryo transfer: A promising approach for patients with repeated implantation failure

  • Stamenov, Georgi Stamenov;Parvanov, Dimitar Angelov;Chaushev, Todor Angelov
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.44 no.2
    • /
    • pp.105-110
    • /
    • 2017
  • Objective: The purpose of this study was to evaluate the efficacy of frozen mixed double-embryo transfer (MDET; the simultaneous transfer of day 3 and day 5 embryos) in comparison with frozen blastocyst double-embryo transfer (BDET; transfer of two day 5 blastocysts) in patients with repeated implantation failure (RIF). Methods: A total of 104 women with RIF who underwent frozen MDET (n = 48) or BDET (n = 56) with excellent-quality embryos were included in this retrospective analysis. All frozen embryo transfers were performed in natural cycles. The main outcome measures were the implantation rate, clinical pregnancy rate, multiple pregnancy rate, and miscarriage rate. These measures were compared between the patients who underwent MDET or BDET using the chi-square test or the Fisher exact test, as appropriate. Results: The implantation and clinical pregnancy rates were significantly higher in patients who underwent MDET than in those who underwent BDET (60.4% vs. 39.3%, p=0.03 and 52.1% vs. 30.4%, p=0.05, respectively). A significantly lower miscarriage rate was observed in the MDET group (6.9% vs. 10.7%, p=0.05). In addition, the multiple pregnancy rate was slightly, but not significantly, higher in the MDET group (27.1% vs. 25.0%). Conclusion: MDET was found to be significantly superior to double blastocyst transfer. It could be regarded as an appropriate approach to improve in vitro fertilization success rates in RIF patients.

A study on the strain rate sensitivity according to the temperature for steel sheets of an auto-body (차체용 강판의 온도에 따른 변형률 속도 민감도 연구)

  • Lee H. J.;Song J. H.;Cho S. S.;Kim S. B.;Huh H.;Park S. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.148-151
    • /
    • 2005
  • This paper is concerned with the thermo-mechanical behavior and temperature dependent strain rate sensitivity of steel sheet for an auto-body. In order to Identify the temperature dependent strain rate sensitivity of SPRC35R and SPRC45E, uniaxial tension tests are performed with the variation of the strain rates from 0.001/sec to 200/sec, and the variation of environmental temperatures from $-40^{\circ}C\;to\;200^{\circ}C$. The thermo-mechanical response at the quasi-static state is obtained with the static tensile test and at the intermediate strain rate is from the high speed tensile test. The experimental results show that the strain rate sensitivity increases at low temperature and it decreases at high temperature. It means that as the strain rate getting increasing, the variation of flow stress is more sensitive on the temperature. The results also indicates that the material properties of SPRC35R is more depend on the changes of strain rates and temperature than those of SPRC45E.

  • PDF

Analysis about relation of Won/Dollar Foreign Exchange Rate and Interest Rate of Korea (한국 원/달러환율과 금리의 관계분석)

  • 김종권
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.48
    • /
    • pp.133-144
    • /
    • 1998
  • International capital movement has made progress at global liberalization of finance and foreign exchange, international monetary norm changing into floating exchange rate system, easiness of collection of information and trade at improvement of information communication technology from early of 1970's. Results of empirical test for relation between foreign exchange rate or various determination factors of foreign exchange rate and interest rate are followed by next sentences. First, according to relation between foreign exchange rate and interest rate, correlation for each of variables after OECD entrance is increased. But, long-term & short-term interest rate is affected by Hanbo & Kia's bankruptcy, continuous large scale corporates bankruptcy and crisis of foreign exchange. Therefore, financial instability is occured. If portfolio investment fund has been inflow as it is mollified by continuous shortage of foreign exchange and fall of country's credit rating, it is expected to have positive effect for long-term & short-term interest rate from appreciation of won against dollar. Second, results from relation between determination factor of foreign exchange rate and interest rate are followed by next sentences. If surplus of current account and goods account is continued, yield of corporate bond is to be stable. But, margin of surplus is expected to diminish after second quarter 98, and difference between external and domestic interest (after adjusting foreign exchange rate) is to be diminished. And if net inflows of foreign investor's fund (stock and bond) is diminished, it is to have negative effect for yield of corporate bond. According to foreign investor's investment movement of previous years, hedge fund were stayed at least during two years in Mexico. It means that sudden capital outflow is not to be happened at Korea. But if external factors from depreciation of yen and China's renminbi are instable, interest rate is expected to increase from capital's outflows. Third, if it is to decrease instability of foreign exchange rate from increase in surplus of future current account, credit rating's upwardness, stability of yen and renminbi, foreign exchange rate is expected to be stable. It is expected to have continuous stability from short-term interest rate to long-term interest rate in this empirical test.

  • PDF

Analysis about relation of Won/Dollar Foreign Exchange Rate and Interest Rate of Korea (한국 원/달러환율과 금리의 관계분석)

  • 김종권
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2002.11a
    • /
    • pp.305-319
    • /
    • 2002
  • International capital movement has made progress at global liberalization of finance and foreign exchange, international monetary norm changing into floating exchange rate system, easiness of collection of information and trade at improvement of information communication technology from early of 1970's. Results of empirical test for relation between foreign exchange rate or various determination factors of foreign exchange rate and interest rate are followed by next sentences. First, according to relation between foreign exchange rate and interest rate, correlation for each of variables after OECD entrance is increased. But, long-term &short-term interest rate is affected by Hanbo & Kia's bankruptcy, continuous large scale coporates bankruptcy and crisis of foreign exchange. Therefore, financial instability is occured. If portfolio investment fund has been inflow as it is mollified by continuous shortage of foreign exchange and fall of country's credit rating, it is expected to have positive effect for long-term & short-term interest rate from appreciation of won against dollar. Second, results from relation between determination factor of foreign exchange rate and interest rate are followed by next sentences. If surplus of current account and goods account is continued, yield of corporate bond is to be stable. But, margin of surplus is expected to diminish after second quarter 98, and difference between external and domestic interest (after adjusting foreign exchange rate) is to be diminished. And if net inflows of foreign investor's fund (stock and bond) is diminished, it is to have negative effect for yield of corporate bond. According to foreign investor's investment movement of previous years, hedge md were stayed at least during two years in Mexico. It means that sudden capital outflow is not to be happened at Korea. But if external factors from depreciation of yen and China's renminbi are instable, interest rate is expected to increase from capital's outflows. Third, if it is to decrease instability of foreign exchange rate from increase in surplus of future current account, credit rating's upwardness, stability of yen and renminbi, foreign exchange rate is expected to be stable. It is expected to have continuous stability from short-term interest rate to long-term interest rate in this empirical test.

  • PDF

A Study of the Effect, Safety and Saving Expense by Reusing Hemodialyzer (재사용(再使用) 투석기(透析器)의 효과(效果) ${\cdot}$ 안정성(安定性) 및 비용절감(費用節減)에 관한 연구(硏究))

  • Jung, Ha-Chung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.93-106
    • /
    • 1997
  • By the increase of the rate of existence of the hemodialyzing patients, they were required the long run treatment. Regardless of medical insurance expansion, hemodialyzing cost much expenses so that hospital has been considering the reuse of hemodialyzer and flowing euqipments along with the diverse study and progress of the ways of hemodialyzing and medical instruments. This study was aimed to provide the basic materials regarding the reuse of hemodialyzer which is used for the patients of chronic renal disease. The reusing program in the artificial kidney center of K hospital has been used for this study from 50 patients aften one year result from Sep. 1995 through Aug. 1996. Automatic equipment of DRS-4 made by Seratronic Co., was used as the equipment and it was retreated with the function test simultaneously. Compliaction and confirmation of the infection were by the records of the hemodialysis of the patients. SPSS was used for the analysis of the materials by computerization. The character of the patients and the rate of removal was by mistake and percentage, function test and rate of complication by Ftest(ANOVA) and the rate of complication per items by ${\chi}^2$ and Ftest. As the post test the Duncan's test was used for the statistically significant different variables in the standard of p<.05 after Ftest. The followings are the summary of the result : 1) In the function test of the new hemodialyzer and the reused one, and in all of CA110 and CF15.11, the dialyzer ultrafiltration coeffient(KUf) was appeared to have been higher in the reusing groups than the first use ones. This has been the normal limit showing no troubles with them. 2) In the function test of the new and reused hemodialyzer, in all of CA110 and CF15.11, the total blood volume was appeared to have been the less value in the reuse groups than the new ones. This was the price within 80% of the first price that both showed possible for use. 3) The result of reuse hemodialyzer of CA110 was $29.48{\pm}7.83$ in average in the test of leak test while $17.3{\pm}7.96$ in reuse of CF15.11. The normal limit of <60 was the leak test result. So both of the hemodialyzer was normal for reuse. 4) The rate of removal of Blood Urea Nitrogen(BUN) was 72.25% in CA110 hemodialyzer by reusing 16-20 times as the highest rate showing the better result in the reuse hemodialyzer, while in CF15.11 hemodialyzer showed 71.16% by highest rate in the first use by the highest rate with no difference from the reuse. 5) The rate of removal of serum creatinine of CA110 was 64.08% by highest rate in reuse of 1-5 times by showing better result in reuse hemodialyzer. While in CF15.11 66.47% the highest by reuse of 16-20 times showing no difference from each other. 6) No patients were admitted or precribed by antibiotics in relation with reuse dialyzer and no reports were shown about hepatitis $B{\cdot}C$. AIDS in fection. 7) Of the total 248 episods of complication due to the hemodialyzing, 86 by first use, 73 by 1-5 times, 35 by 6-10 times, 35 by 11-15 times and 19 by 16-20 times have been shown which have had no significant difference between the groups. 8) In the comparison of the expense for the hemodialyzer, there was the effect of saving 11,597.6 Won between the first and reuse hemodialyzer. And by decreasing the extracted materials, they did the great role of disposing the waste matters.

  • PDF

CARIES PREDICTION MODEL USING LASER FLUORESCENCE (레이저 형광법을 이용한 우식유발 예측모형)

  • Lee, Sang-Ho;Lee, Chang-Seop;Jeong, Yeon-Hwa
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.16-24
    • /
    • 2001
  • The purpose of this study was to evaluate the specificity, sensitivity, and diagnostic power of caries activity test using laser fluorescence. The subjects of this study were 50 children of $7\sim9$ years old. Fluorescence from initial carious lesion of teeth illuminated by an argon laser(480nm) was observed and photographed with barrier filter. Visual examination for the dDfFtT rate and Streptococcus mutans colony counting was done to evaluate correlation with caries activity test using laser fluorescence. Data analysis was accomplished by Axelsson's method. The results from the present study can be summarized as follows: 1. There was positive correlation $(\gamma=0.48)$ between laser fluorescence test and Streptococcus mutans count. And also positive correlation $(\gamma=0.39)$ exists between laser fluorescence test and dDfFtT rate (P<0.01). 2. Positive correlation $(\gamma=0.27)$ between Streptococcus mutans colony count and dDfFtT rate was found(P<0.05). 3. When dDfFtT rate was defined to standard testing method, the specificity, senstivity, and diagnostic power of laser fluorescence test were 44.4%, 85.7%, and 87.8%. 4. When dDfFtT rate was defined to standard testing method, the specificity, senstivity, and diagnostic power of S. mutans colony counting were 77.8%, 92.9%, 84.8%. 5. When S. mutans colony counting was defined to standard testing method, sensitivity, specificity and diagnostic power of laser fluorescence test were 40.0%, 84.8%, 95.1%. In regard to above results, laser fluorescence test considered to be accurate and reliable method for determining caries activity because of it's close relationship with caries susceptibility test and caries experience measurements. And it was also considered to be practical because it would be simple, inexpensive, and time saving method.

  • PDF

The Study on Estimating Life Cycle of 2.5 Inch Hard disk base on PC using enviroment (PC 사용 환경에 기반한 2.5 인치 하드 디스크의 수명주기 예측에 대한 연구)

  • Cho, Euy-Hyun;Park, Jeong-Kyu;Lee, Min-Woo;Kwon, Soon-Mu
    • Journal of Digital Contents Society
    • /
    • v.15 no.2
    • /
    • pp.301-308
    • /
    • 2014
  • The mass storage of data and the importance of storage capacity lately has emerged. In this paper, we suggest the new method which estimate life cycle from acceleration life test about 2.5 inch hard disk driver as mass storage, which minimize the difference between real market annual failure rate and estimated failure rate. we obtain market transfer capacity per hours from returned 2.5inch hard disk drives about 309 numbers and accelerating transfer capacity per hours from acceleration life test. we calculate acceleration factor about duty cycle and estimate annual failure rate from failure rate and acceleration factors: temperature acceleration factor, duty cycle acceleration factor, the transfer capacity per hour represent the 93.4 % of user is 5.8 GB/hour, the transfer capacity per hour from acceleration life test is 81.4 GB/hour. the acceleration factor of duty cycle is 14.1. annual failure rate is stabilized at market one year after, annual failure rate is between 0.3 and 0.378. estimated annual failure rate is 0.4, so it is matched at 75~94 % between estimate annual failure rate and market annual failure rate. This study influence the estimate method of annual failure rate by the result of acceleration life cycle of manufacture.