• 제목/요약/키워드: Range of variation

Search Result 3,245, Processing Time 0.035 seconds

Fabrication of ZnO Nanorod based Robust Nanogenerator Metal Substrate (금속 기판적용을 통한 ZnO 나노로드기반 나노제너레이터 제조)

  • Baek, Seong-Ho;Park, Il-Kyu
    • Journal of Powder Materials
    • /
    • v.22 no.5
    • /
    • pp.331-336
    • /
    • 2015
  • We report on the succesful fabrication of ZnO nanorod (NR)-based robust piezoelectric nanogenerators (PNGs) by using Cu foil substrate. The ZnO NRs are successfully grown on the Cu foil substrate by using all solution based method, a two step hydrothermal synthesis. The ZnO NRs are grown along c-axis well with an average diameter of 75~80 nm and length of $1{\sim}1.5{\mu}m$. The ZnO NRs showed abnormal photoluminescence specrta which is attributed from surface plasmon resonance assistant enhancement at specific wavelength. The PNGs on the SUS substrates show typical piezoelectric output performance which showing a frequency dependent voltage enhancement and polarity dependent charging and discharging characteristics. The output voltage range is 0.79~2.28 V with variation of input strain frequency of 1.8~3.9 Hz. The PNG on Cu foil shows reliable output performance even at the operation over 200 times without showing degradation of output voltage. The current output from the PNG is $0.7{\mu}A/cm^2$ which is a typical out-put range from the ZnO NR-based PNGs. These performance enhancement is attributed from the high flexibility, high electrical conductivity and excellent heat dissipation properties of the Cu foil as a substrate.

Dielectric Relaxation in Ethylene Glycol - Dimethyl Sulfoxide Mixtures as a Function of Composition and Temperature

  • Undre, P.B.;Khirade, P.W.;Rajenimbalkar, V.S.;Helambe, S.N.;Mehrotra, S.C.
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.4
    • /
    • pp.416-423
    • /
    • 2012
  • Using time domain reflectometry, the complex dielectric spectra between 10 MHz to 20 GHz has been measured in the whole composition range at 10, 20, 30 and $40^{\circ}C$ for the binary mixtures of ethylene glycol and dimethyl sulfoxide. For all the mixtures, only one dielectric loss peak was observed in this frequency range. The relaxation in these mixtures can be described by a single relaxation time using the Debye model. A systematic variation is observed in dielectric constant (${\varepsilon}_0$) and relaxation time (${\tau}$). The excess permittivity (${\varepsilon}^E$), excess inverse relaxation time $(1/{\tau})^E$, Kirkwood correlation factor (g) and thermodynamic parameters viz. enthalpy of activation (${\Delta}H$) and Gibbs free energy of activation (${\Delta}G$) have been determined, to confirm the formation of hydrogen bonded homogeneous and heterogeneous cooperative domains, the dynamics of solute - solute interaction and the hindrance to molecular rotation in the hydrogen bonded glass forming ethylene glycol - dimethyl sulphoxide system.

NUMERICAL PREDICTION OF THE OPTIMAL STAGGER ANGLES FOR A HIGH-POWER TURBO BLOWER (고마력 터보 블로어의 최적 깃배치각에 관한 수치 예측)

  • Park, T.G.;Chung, H.T.;Park, J.Y.;Sung, B.I.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.75-81
    • /
    • 2011
  • The turbo blowers having large power capacity are generally composed of the variable inlet guide vane, the impeller and the variable diffuser. In the present study, the effect of the stagger angles on the aerodynamic performances has been investigated by CFD methods. The design specifications of the reference model having 400kW power were given as 7.43kg/s of mass flow rate, 1.66 of pressure ratio with 12000rpm of impeller rotating speed. As the first simulation parameter, the diffuser vane angle was varied in the range of ${\pm}$20 degree from the initial-design point. The inlet guide vane angles, as the second one, was changed in the range of ${\pm}$40 degree from the initial-design point. The commercial Navier-Stokes solver, ANSYS-CFX, was applied to solve the three-dimensional unsteady flow fields inside the turbo blower. Through the numerical results, the desirable setting angles were proposed to fit the best performance to the variation of the operating conditions.

A Study on the Mechanism with the Electrode Ratio of Driving and Generation Part of a Disk-Type Piezoelectric Transformer (디스크형 압전변압기의 전극 면적비에 따른 구동 메카니즘에 관한 연구)

  • Lee, Jong-Pil;Chae, Hong-In;Jin, Woong-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.17-22
    • /
    • 2005
  • In this study, a disk-type piezoelectric transformer was fabricated. Its diameter was 50[mm] and thickness was 4.5[mm]. The driving and generating electrode with their gap of 1[mm] were fabricated on the top surface. But the common electrode was fabricated on the whole bottom surface. The electrode surface ratio of driving and generating part on the top surface was the range of 1.4:1 to 3:1. We investigated the electrical characteristics with the variation of its thickness and the electrode surface ratio of driving and generating part in the range of load resistance of 100${[\Omega]}\~70{[k\Omega]}$.. Form the experimental results, their influence on the set-up voltage ratio were investigated quantitively and qualitatively.

A Sensitivity Analysis of the OZIPR Modeling Result for the Seoul Metropolitan Area (OZIPR 모델링 결과의 민감도 분석)

  • Lee, Sun-Hwa;Jin, Lan;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.7 no.3
    • /
    • pp.99-108
    • /
    • 2011
  • To establish area specific control strategies for the reduction of the ozone concentration, the Ozone Isopleth Plotting Package for Research(OZIPR) model has been widely used. However, the model results tend to changed by various input parameters such as the background concentration, emission amount of NOx and volatile organic compounds (VOCs), and meteorological condition. Thus, sensitivity analysis should be required to ensure the reliability of the result. The OZIPR modeling results for five local government districts in the Seoul Metropolitan Area (SMA) in June 2000 were used for the sensitivity analysis. The sensitivity analysis result showed that the modeling result of the SMA being VOC-limited region be still valid for a wide range of input parameters' variation. The estimated ozone concentrations were positively related with the initial VOCs concentrations while were negatively related with the initial NOx concentrations. But, the degree of the variations at each local district was different suggesting area specific characteristics being also important. Among the five local governments, Suwon was chosen to identify other variance through the period from April to September in 2000. The monthly modeling results show different ozone values, but still showing the characteristics of VOCs-limited region. Limitations due to not considering long range transport and transfer from neighbor area, limitation of input data, error between observed data and estimated data are all discussed.

An Experimental Study on Loss Coefficient of Turbine Cascade with Incidence Angles (입사각의 변화에 따른 터빈 캐스케이드에서 손실계수에 관한 실험적 연구)

  • Lee, Ju-Hyung;Hur, Won-Hae;Jeon, Chang-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.4 s.5
    • /
    • pp.48-56
    • /
    • 1999
  • For the study on loss coefficients of turbine cascade with variation of incidence angle, the wind-tunnel tests were performed under the ranges in velocity of 10 m/s, 15 m/s, 20 m/s and incidence angles from $-20^{\circ}\;to\;20^{\circ}$ by intervals of $5^{\circ}$. Comparing our results with Soderberg's prediction, differences in loss coefficient were $2.5\%\;and\;2.8\%$ each for 10 m/s and 15 m/s. A large disagreement of $30.3\%$ was showed at 20 m/s freestream velocity. The comparisons of these test results with Ainley's prediction showed an $8\%$ difference in the case of 20 m/s freestream velocity. Test results were approximately comparable with Ainley's loss prediction's in incidence angles. Generally, averaged total pressure loss seemed to be decreased as Reynolds number increased. The total pressure loss coefficients were increased parabolically, as incidence angles were increased negatively and positively from $0^{\circ}$, in all speed ranges. At the far low freestream velocities, minimum loss accurred between $-5^{\circ}\;and\;+5^{\circ}$. But this minimum range narrowed the location of this range by shifting to the direction of the angle as freestream velocity was increased.

  • PDF

Compositional Variations of Sphalerites and Their Genetic Characteristics from Gold and/or Silver Deposits in Central Korea (한국 중부지역 금은광상산 섬아연석의 조성변화와 성인적 특성)

  • Choi, Seon-Gyu
    • Economic and Environmental Geology
    • /
    • v.26 no.2
    • /
    • pp.135-143
    • /
    • 1993
  • Chemical compositions of sphalerites from 25 gold and/or silver deposits in central Korea were obtained with an electron probe microanalyzer. The FeS contents of sphalerites depend generally upon the assemblage of associated iron sulphides (pyrite and/or pyrrhotite) especially. The sphalerites coexisting with pyrrhotite show a narrow range of FeS variation, but the sphalerites associated with pyrite and/or pyrrhotite have the variable and wide range of FeS contents. The sphalerites from Au-dominant deposits, which vary considerably in each deposit, are generally characterized by high CdS content and low MnS content. On the contrary, the sphalerites from Ag-dominant and Au-Ag deposits tend to be characterized by relatively high MnS and very low CdS content. Based upon the mineralogy, fluid inclusions and stable isotope data, the Au-dominant deposits were formed under higher temperature and deeper depth than the Ag-dominant and Au-Ag deposits. The results suggest the possibility that the diverse sources and evolution of ore fluid at the time of ore deposition are responsible for the deposition of Cd and Mn components in sphalerites.

  • PDF

Sex differences in repeatability of measurement for hamstring strength during maximal voluntary contractions (최대 수의적 수축 동안 뒤넙다리근 근력 반복성의 남녀 차이)

  • Lim, Woo Taek
    • Journal of Korean Physical Therapy Science
    • /
    • v.27 no.1
    • /
    • pp.9-17
    • /
    • 2020
  • Background: This study aimed to examine the repeatability of hamstring strength during maximal voluntary contractions (MVCs) and to examine the sex difference. Design: Quasi-experiment design. Methods: The study recruited 23 healthy young individuals as participants. Hamstring flexibility was measured before and after MVCs by active knee extension test. Five trials of MVCs were performed, and hip extension forces were measured using a strain gauge during MVCs. Repeatability was confirmed by intraclass correlation coefficient (ICC) and coefficient of variation, and the difference between male and female participants was confirmed by independent samples t-test. Results: The forces measured during MVCs were significantly different between men and women over five trials. We observed the minimum and maximum force production at the first and fifth trial of MVCs in both men and women. Excellent to moderate reliability of the hamstring strength during MVCs was found in men (ICC range, 0.70-0.98) and women (ICC range, 0.66-0.90). There was no significant difference in hamstring flexibility between men and women. Conclusion: In clinical settings, we recommend excluding the first trial of MVCs in both men and women. Additionally, performing at least three trials of MVCs would be useful to improve the reliability of the baseline measures in women.

On the Thermal Low-pressure Onset using Analytical Model around Daegu in Summer (해석학적모델을 이용한 하계 대구지방의 열적저기압 형성에 관한 연구)

  • 김해동;정우식
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1133-1140
    • /
    • 2002
  • The growth and extent of the local pressure field at any point is of primary importance as it supplies the driving force for the local wind circulation which causes a medium-range transport of air pollutants. The local pressure field is produced by the variation of temperature in the lower layers of the atmosphere, and is called the thermal wave. The thermal wave is influenced by the difference in the diurnal variations between two regions with different surface condition, for example land and sea. This difference produces the land- and sea-breeze phenomenon, and brings corresponding variations in the form of the thermal wave. Daytime temperature over the inland area (Daegu) was higher than that of the coastal area (Busan). The temperature difference reached about 5~6$^{\circ}C$ in the late afternoon(30-31 May 1999). The low pressure system of Daegu was most fully developed at the time. In this study, we investigated the possibility of thermal low onset around Daegu in summer with an analytical model. The topography effect was neglected in the model. We could predict a thermal low-pressure of about 3.4hPa at Daegu with wide flat land surface, when the inland area is about 6K warmer than the coastal area temperature. The pressure decrease is somewhat less than the observed value(4~5 hPa).

Correct Posture Guidance System using 3-axis Acceleration Sensor for Scoliosis Patient (3축 가속도 센서를 이용한 자세 교정 유도 시스템)

  • An, Yang-Soo;Kim, Keo-Sik;Seo, Jeong-Hwan;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.220-224
    • /
    • 2010
  • In this study, we designed a device for consecutively observing position, utilizing 3-axises acceleration sensor. This method offer to check his or her wrong position and developed could to help derived a position appliance. And, we developed a Cobb's angle value in three dimensional using 3-axises acceleration sensor. A proposed device with integrated accelerometers, which can detect postural changes in terms of curvature variation of the spine in the sagittal and coronal planes, has been developed with intention to facilitate posture training. The proposed device was evaluated with 3 normal subjects daily activities. We evaluated the performance of our designed device as calculating the correlation coefficients and mean errors between the angle measured by an electro-goniometer and that estimated by a gravity accelerometer and verified the accuracy and sensitivity. The results showed that the angle obtained from the proposed device revealed a linear characteristic at the range of $\pm60^{\circ}$(correlation coefficient 0.99, error range $\pm2^{\circ}$). We demonstrated that our device could detect the changes of the motion in upper trunk accurately. Also, our device showed good potential for treatment of the patients with scoliosis and prevention of the unbalance position during a daily life.