• Title/Summary/Keyword: Range of variation

Search Result 3,245, Processing Time 0.04 seconds

Analytical Modeling for Short-Channel MOSFET I-V Characteristice Using a Linearly-Graded Depletion Edge Approximation (공핍층 폭의 선형 변화를 가정한 단채널 MOSFET I-V 특성의 해석적 모형화)

  • 심재훈;임행삼;박봉임;여정하
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.4
    • /
    • pp.77-85
    • /
    • 1999
  • By assuming a linearly graded depletion edge approximation in the intrinsic MOS region and by taking into account the mobility variation dependent on both lateral and vertical fields, a physics-based analytical model for a short-channel(n-channel) MOSFET is suggested. Derived expressions for the threshold voltage and the drain current of typical MOSFET is structures could be used in a unified manner for all operating range. The threshold voltage was calculated by changing following variables : channel length, drain-source voltage, source-substrate voltage, p-substrate doping level, and oxide thickness. It is shown that the threshold voltage decreases almost exponentially as the channel length decreases. In addition, the short-channel threshold voltage roll-off, the channel length modulation and the electron mobility degradation can be derived within a satisfactory accuracy.

  • PDF

Wind tunnel test for the 20% scaled down NREL wind turbine blade (NREL 풍력터빈 블레이드 20% 축소모델 풍동시험 결과)

  • Cho, Taehwan;Kim, Cheolwan;Kim, Yangwon;Rho, Joohyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.33.2-33.2
    • /
    • 2011
  • The 'NREL Phase VI' model with a 10.06m diameter was tested in the NASA Ames tunnel to make a reference data of the computational models. The test was conducted at the one rotational speed, blade tip speed 38m/s and the Reynolds number of the sectional airfoils in that test was around 1E6. The 1/5 scale down model of the 'NREL Phase VI' model was used in this paper to study the power characteristics in low Reynolds number region, 0.1E6 ~ 0.4E6 which is achievable range for the conventional wind tunnel facilities. The torque generated by the blade was directly measured by using the torque sensor installed in the rotating axis for a given wind speed and rotational speed. The power characteristics below the stall condition, lambda > 4, was presented in this paper. The power coefficient is very low in the condition below the Re. 0.2E6 and rapidly increases as the Re. increases. And it still increases but the variation is not so big in the condition above the Re. 0.3E6. This results shows that to study the performance of the wind turbine blade by using the scaled down model, the Re. should be larger than the 0.3E6.

  • PDF

A load-bearing structural element with energy dissipation capability under harmonic excitation

  • Pontecorvo, Michael E.;Barbarino, Silvestro;Gandhi, Farhan S.;Bland, Scott;Snyder, Robert;Kudva, Jay;White, Edward V.
    • Advances in aircraft and spacecraft science
    • /
    • v.2 no.3
    • /
    • pp.345-365
    • /
    • 2015
  • This paper focuses on the design, fabrication, testing and analysis of a novel load-bearing element with energy dissipation capability. A single element comprises two von-Mises trusses (VMTs), which are sandwiched between two plates and connected to dashpots that stroke as the VMTs cycle between stable equilibrium states. The elements can be assembled in-plane to form a large plate-like structure or stacked with different properties in each layer for improved load-adaptability. Also introduced in the elements are pre-loaded springs (PLSs) that provide high initial stiffness and allow the element to carry a static load even when the VMTs cannot under harmonic disturbance input. Simulations of the system behavior using the Simscape environment show good overall correlation with test data. Good energy dissipation capability is observed over a frequency range from 0.1 Hz to 2 Hz. The test and simulation results show that a two layer prototype, having one soft VMT layer and one stiff VMT layer, can provide good energy dissipation over a decade of variation in harmonic load amplitude, while retaining the ability to carry static load due to the PLSs. The paper discusses how system design parameter changes affect the static load capability and the hysteresis behavior.

A Study on the Weavingless Arc Sensor System in GMA Welding (II) -Torch Height Control in Weld Seam Tracking (GMA 용접에서 강제적인 위빙이 없는 아크센서 시스템에 관한 연구 (II) -용접선 추적의 토치방향 높이제어-)

  • 안재현;김재웅
    • Journal of Welding and Joining
    • /
    • v.16 no.3
    • /
    • pp.55-63
    • /
    • 1998
  • Among the position sensing methods available, the arc sensor which utilizes the electrical signal obtained from the welding arc itself is one of the most prevalently used methods, because it has an advantage that no particular sensing device is necessary and real-time sensing of a groove position is possible directly under the arc. The authors have already developed a seam tracking system that contains a new arc sensor algorithm, which uses the relative welding current variation according to the tip-to-workpiece distance in GMA welding. In this study a torch height control algorithm for automatic weld seam tracking was proposed for completing the previous system, which uses an on-off control technique. To implement the torch height control algorithm during weld seam tracking the system parameters which include 2nd averaging range, weighting factor for 2nd moving averaging, and Z-directional basic compensation distance were determined by experimental analysis. Finally the two different height control methods, one is simple on-off control and the other on-off control using a reference current value , were compared in their tracking abilities.

  • PDF

Image Distortion Correction Processing System Realization for Fisheye Lens Camera (어안렌스 카메라의 영상왜곡보정처리 시스템 구현)

  • Ryu, Kwang-Ryol;Kim, Ja-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.11
    • /
    • pp.2116-2120
    • /
    • 2007
  • A realization for image distortion correction processing system with DSP processor is presented in this paper. The image distortion correcting algorithm is realized by DSP processor for focusing on more real time processing than image quality. The lens and camera distortion coefficients are processed by the Lookup Tables and the correcting algorithm is applied to reverse mapping method for geometrical transform. The system experimentation results in the processing time about 31.3 msec $720{\times}480$ wide range image, and the image is stable and spontaneous to be about 8.3% average PSNR variation with changing a wide angle.

A Fully Digital Automatic Gain Control System with Wide Dynamic Range Power Detectors for DVB-S2 Application (넓은 동적 영역의 파워 검출기를 이용한 DVB-S2용 디지털 자동 이득 제어 시스템)

  • Pu, Young-Gun;Park, Joon-Sung;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.58-67
    • /
    • 2009
  • This paper presents a fully digital gain control system with a new high bandwidth and wide dynamic range power detector for DVB-S2 application. Because the peak-to-average power ratio (PAPR) of DVB-S2 system is so high and the settling time requirement is so stringent, the conventional closed-loop analog gain control scheme cannot be used. The digital gain control is necessary for the robust gain control and the direct digital interface with the baseband modem. Also, it has several advantages over the analog gain control in terms of the settling time and insensitivity to the process, voltage and temperature variation. In order to have a wide gain range with fine step resolution, a new AGC system is proposed. The system is composed of high-bandwidth digital VGAs, wide dynamic range power detectors with RMS detector, low power SAR type ADC, and a digital gain controller. To reduce the power consumption and chip area, only one SAR type ADC is used, and its input is time-interleaved based on four power detectors. Simulation and measurement results show that the new AGC system converges with gain error less than 0.25 dB to the desired level within $10{\mu}s$. It is implemented in a $0.18{\mu}m$ CMOS process. The measurement results of the proposed IF AGC system exhibit 80-dB gain range with 0.25-dB resolution, 8 nV/$\sqrt{Hz}$ input referred noise, and 5-dBm $IIP_3$ at 60-mW power consumption. The power detector shows the 35dB dynamic range for 100 MHz input.

Characteristics of Radon Variability in Soils at Busan Area (부산광역시 일대의 토양 내 라돈 농도 변화 특성)

  • Kim, Jin-Seop;Kim, Sun-Woong;Lee, Hyo-Min;Choi, Jeong-Yun;Moon, Ki-Hoon
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.277-294
    • /
    • 2012
  • The characteristics of temporal spacial radon variation in soil according to parent rock type and affecting factors were studied in Busan, Korea. The concentration of $^{222}Rn$ in soils and their parent elements ($^{226}Ra$,$^{228}Ra$, U and Th) in rocks and soils were measured at 24 sites in Busan area. The distribution and transportation behavior of these parent elements were analyzed and their correlations to radon concentration in soil were determined. Topographic effects were also evaluated. Two in-situ radon measurement (soil probe and buried tube) methods were applied to measure radon concentration in soil and their accuracies were evaluated. The spatial variation of radon in soil generally reflected U concentration in the parent rock. Average radon concentrations were higher in plutonic rocks than in volcanic rocks and were decreased in the order of felsic>intermediate>mafic rock. However, the radon concentrations were significantly varied in soils developed from same parent rocks due to the disequilibrium of U and $^{226}Ra$ between rock and soil. As results, the correlation of these element concentrations between rocks and soils was very low and radon concentrations in soils had highly co-related to the concentrations of these elements in soils. Th and $^{228}Ra$ show complex enrichment characteristics, differing significantly with U, in soils developed from same parent rock because the geochemical behavior of these elements during weathering and soil developing process was different with U. The radon concentrations in the same depth of soil in slope area were also different according to positions. The radon concentrations in soils developed from same parent rocks (19 sites at Pusan National University) varied 6.8~29.8Bq/L range because of small scale topographic variation. The opposite seasonal variation pattern of radon were observed according to soil properties. It was determined that buried tube method is more accurate method than soil probe method and was very advantageous application for the analysis for the characteristics of temporal spacial radon variation in soil.

Seasonal Variations of Environmental Factors and Distribution of Anabaena cylindrica Growth-Inhibiting Bacteria in the Lower Daechung Reservoir (대청호 하류에서 환경요인과 Anabaena cylindrica 생장억제세균의 계절별 분포 변화)

  • Lee, Jung-Ho;Kim, Chul-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.2 s.90
    • /
    • pp.128-135
    • /
    • 2000
  • The authors surveyed the seasonal variations of environmental factors, the distributions of heterotrophic bacteria and Anabaena cylindrica growth-inhibiting bacteria at each water layer in Daechung Reservoir to verify the role of bacteria during the extinction of bloom. Average water depth at site 1, 2, and 3 were 25.5 m, 15.0 m and 12.3 m, respectively. Water temperature showed a typical pattern seasonally. The variation of DO was relatively inverse proportional to that of water temperature, although it was irregular during summer time. DO decreased gradually to early May, fluctuated sharply after then, and followed by gradual increasement after middle of September. This variation pattern was notable at surface layer. There was remarkable difference in DO concentraion between surface layer and the other water layers during the period in which DO irregulary varied. The variation range of chlorophyll-a concentraion at surface layer in summer time was broad, and it was relatively high when DO was high. The population size of heterotrophic bacteria was high from Spring to Autumn, an declined after September when the water temperature droped rapidly. Especially this variation pattern was prominent at the surface layer. Bacteria that inhibit the growth of A. cylindrica was almost not detected by June, and its distribution increased in July. Afterward, it showed different variation pattern between each site. The distribution of A. cylindrica growth-inhibiting bacteria was higher at the middle and bottom layer than the surface layer in July and October, when it was larger at all sites for the study period. This result suggests that the antagonistic bacteria exhibit higher activity when host activity drops. These results also suggest that natural water bacteria control the distirbution of cyanobacteria, especially its activity as controller is remarkable when cyanobacterial growth declines.

  • PDF

Characteristics of Diurnal Variation of High PM2.5 Concentration by Spatio-Temporal Wind System in Busan, Korea (시·공간적 풍계에 따른 부산지역 고농도 PM2.5의 일변화 특성)

  • Kim, Bu-Kyung;Lee, Dong-In;Kim, Jeong-Chang;Lee, Jun-Ho
    • Journal of the Korean earth science society
    • /
    • v.33 no.6
    • /
    • pp.469-480
    • /
    • 2012
  • This study was to analyze the characteristics of diurnal variation of high $PM_{2.5}$ concentration, $PM_{2.5}/PM_{10}$ concentration ratio by spatio-temporal wind system (wind speed and wind direction) for high $PM_{2.5}$ concentration (over the 24 hr environmental standard of $PM_{2.5}$, $50{\mu}g/m^3$) in the air quality observation sites (Jangrimdong: Industrial area, Jwadong: Residential area) that were measured for 3 years (2005. 12. 1-2008. 11. 30) in Busan. The observation days of high $PM_{2.5}$ concentration were 182 at Jangrimdong and 27 at Jwadong. The seasonal diurnal variation of hourly mean of high $PM_{2.5}$ concentration and of $PM_{2.5}/PM_{10}$ concentration ratio showed a similar pattern that had higher variation at dawn, and night and in the morning than in the afternoon. Durning daytime in summer at Jwadong, the $PM_{2.5}/PM_{10}$ concentration ratio increased because a secondary particulate matter, which was created by photochemical reaction, decreased the coarse particles of $PM_{10}$ more than the fine particles of $PM_{2.5}$ concentrations in ocean condition. We did an analysis of spatio-temporal wind system (wind speed range and wind direction) in each time zone. The result showed that high $PM_{2.5}$ concentration at Jangrimdong occurred due to the congestion of pollutants emissions from the industrial complex in Jangrimdong area and the transportation of pollutants from places nearby Jangrimdong. It also showed that high $PM_{2.5}$ concentration occurred at Jwadong because of a number of local residential and commercial activities that caused the congestion of pollutants.

Preliminary study on the use of near infrared spectroscopy for determination of plasma deuterium oxide in dairy cattle

  • Purnomoadi, Agung;Nonaka, Itoko;Higuchi, Kouji;Enishi, Osamu;Amari, Masahiro;Terada, Fuminori
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4101-4101
    • /
    • 2001
  • Information of body composition (fat and protein) in living animal is important to determine the nutrients requirement. Deuterium oxide (D2O) dilution techniques, as one of isotope dilution techniques have been useful for the prediction of body composition. However, the determination of D2O concentration is time consuming and complicated. Therefore this study was conducted to develop a new method to predict D2O concentration in plasma using near infrared spectroscopy technique (NIRS). Four dairy cows in early lactation were used. They were fed total mixed ration containing conr silage, timothy hay, and concentrates to make 17.0%CP and 14.0 MJDE/kgDM. Dosing D2O was at week 1,3 and 5 after parturition. After dosing D2O, the blood was collected from hour 0 to 72. Blood samples were then centrifuge at 3,000 rpm for 10 minutes to obtain plasma. D2O concentration was analyzed by gas chromatograph (deuterium oxide analyzable system, HK102, Shokotsusyou) after extracted from plasma by liophilization. Plasma sample was scanned by NIRS using Pacific Scientific (Neotec) model 6500 (Perstorp Analytical, Silver Spring, MD) in the range of wavelength from 1100 to 2500 nm. Calibration equation was developed using multiple linear regression. Sample from one animal (cow #550; n: 74) was used for developing the calibration while the rest three animals were used for validating the equation. The range, R and SEC of the calibration set samples were 135-925 ppm, 0.93 and 48.1 ppm, respectively. Validation of the calibration equation for three individual cows was done and the average of NIR predicted value of D2O at each collection time from three weeks injection showed a high correlation. The range, r and 53 of plasma from cow #474 were 322-840 ppm,0.93 and 53.1; cow #478 were 146-951 ppm,0.95 and 39.8; cow #942 were 313-885 ppm,0.95 and 37.2, respectively. Judgement of accuracy based on ratio of standard deviation and standard error in validation set samples (RPD) for cow #474, #478 and #942 were 2.2,4.3 and 3.4, respectively. The error in application due to the variation between individual was considered smaller than the bias from collection period, however, this prediction can be overcome with correction of standard zero-minute concentration of blood. The results of this preliminary study on the use of NIRS for determination of D2O in plasma showed very promising as shown by a convenient and satisfy accuracy. Further study on various physiological stage of animal should be done.

  • PDF