• Title/Summary/Keyword: Range of variation

Search Result 3,245, Processing Time 0.03 seconds

관리형 매립시설 침출수 중 $SCN^-$제거를 위한 SBR 공정

  • Seong, Se-Hyeon;Hwang, Seok-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.274-277
    • /
    • 2001
  • This research was conducted as a part of continuous development of a bioprocess to treat thiocyanate($SCN^-$) in the leachate from an industrial landfill site. Detailed characteristics of the leachate, physical and chemical, was analyzed in this study. Time to reach equilibrium in $SCN^-$ degradation at different temperature, similar to the annual variation. was investigated for posssible adaptation of the bioprocess in the treatment site. Complete mineralization of $SCN^-$ to ammonia. bicarbonate and sulfate at all temperature range with except $5^{\circ}C$ trial was observed with different time elapsed to reach equilibrium. which shortened as the process of Fill-Draw proceeded. The final metabolites were mainly nitrate and sulfate. No fouling odor was detected and the settling characteristic of the biomass after the treatment was good(i.e., sludge volume index(SVI) ${\le}$80). Using MWT sludge as an inoculum showed better performance with respect to the elapsed time for treatment and sedimentation characteristics than those of using 2BET sludge.

  • PDF

Characterization of NOx Emission from Soils in Southwest Korea and Their Atmospheric Chemistry (질소산화물의 토양배출량 추정과 지구 환경에 미치는 대기화학적 특성 연구)

  • 김득수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.6
    • /
    • pp.451-461
    • /
    • 1997
  • The soil NO flux measurements in Korea were made from 17 May 1997 to 16 June 1997 on grass land at Kunsan National University in southwestern Korea by using flow-through chamber technique. The experiment was conducted in an effort to determine the role of natural emissions of NO on rural atmospheric photochemistry, and to understand the soil NO emission mechanism with respect to soil parameters. Soil NO fluxes were measured every minutes and averaged in every 15 minutes as well as soil temperature. Soil samples were analyzed for $NO_3^-, NH_4^+$, and moisture in soil. Soil nitrate was not detected in most times, and total N-containing was limited in site soils. There was a optimum range of soil moisture and temperature for soil NO flux. The overall average of soil NO emission rates were found to be 1.30 $\pm 0.92 ngNm^{-2}s^{-1}$ (n=1219), and ranged from 0.01 ngNm^{-2}s^{-1}$ to 5.62 ngNm^{-2}s^{-1}$. Diurnal variation of soil NO emission was typical, which was in higher level during daytime, and was in lower level over the night. NO flux showed a strong soil temperature dependence $(r^2=0.78)$, but not with soil moisture and soil N-containing during this experimental period; NO fluxes increased exponentially as soil temperature increased. In order to assure the relevant relationship between soil NO flux and the soil parameters, long-term soil flux measurement on different types of land use should be planned and conducted continuously.

  • PDF

A Study on the Limiting Factors in Wastewater Treatment by Contact Oxidation Process (접촉담화공정에 의한 폐수처이에 있어서의 제한요권에 관한 연구)

  • 황상용;손종열;우완기
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.2
    • /
    • pp.45-52
    • /
    • 1990
  • This study is to discuss limiting factors influenced on the removal efficiency of organic materials investigated using the polypropyrene biofilter which appropriate to attach micro-organism in order to apply the contact oxidation proce,:5. The results obtained in the experiment were as follows : 1. In the range o: pH 4.0~ 12.0 was obtained the removal efficiency of COD higher than 85% It was proved that variation of pH(4.0 ~ 12.0) was nothing to do with the removal efficiency of substrate in continuous reactor. 2. Temperature to obtain removal efficiency of COD higher than 85% was $10^{\circ}$ ~$40^{\circ}$. Removal efficiency of COD was no less than those at high temperature if MLVSS concentration was maintained 8,000~ 15,000 m/1. 3. In the continuous reactor, the volumetric loading of COD for removal efficiency higher than 95% had to be 0.5~1.5 kg COD/.d below. And then the HRT was Bhrs. 4. In comparison with the conventional activate sludge process, the contact oxidation process was excellent in removal efficiency, sludge production rate and maintenance.

  • PDF

Performance and Internal Flow Analysis on the 80kW-Class Cross-Flow Hydro Turbine with the Variation of Effective Head (유효낙차에 따른 80kW급 횡류수차의 성능 및 내부유동 해석)

  • Choi, Young-Do;Lim, Jae-Ik;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.703-710
    • /
    • 2010
  • Recently, small hydropower attracts attention because of its clean, renewable and abundant energy resources to develop. However, suitable turbine type is not determined yet in the range of small hydropower and it is necessary to study for the effective turbine type. Therefore, a 80kW-Class cross-flow turbine is adopted in this study because of its simple structure and high possibility of applying to small hydropower. The result shows that as effective head increases, tangential and radial flow velocities increase and thus, the increased tangential velocity contributes to the increase of angular momentum and output torque.

Prediction and Analysis of Photovoltaic Modules's Output using MATLAB (MATLAB을 이용한 태양광 모듈의 출력 예측 및 해석)

  • Heo, Yun-Seok;Kim, Jae-Gyu;Kim, Ji-Man;Kwon, Bo-Min;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2963-2967
    • /
    • 2010
  • In this paper, we have predicted and analyzed the MSX 60 photovoltaic module's output according to the temperature and solar radiation conditions by MATLAB program. 2 and 3-dimensional I-V curves of the PV module considered temperature, series resistance and solar radiation variation. are shown. Also, calculated PV's electrical parameters are Isc = 3.8 A, Voc = 21 V, Pmax = 60 W. Compared with the actual photovoltaic module's data, these simulated results agreed well with within the manufacturer's maximum error range 3%.

Studies on the Performance Variation of a Variable Speed Vapor Compression System under Fault and Its Detection and Diagnosis (가변속 증기압축 냉동시스템에서 고장시의 성능변화와 고장 감지 및 진단에 관한 연구)

  • Kim Minsung;Kim Min Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.47-55
    • /
    • 2005
  • An experimental study has been peformed to develop a scheme for fault detection and diagnosis(FDD) in a vapor compression refrigeration system. This study is to analyze fault effect on the system performance and to find efficient diagnosis rules for easy determination of abnormal system operation. The refrigeration system was operated with a variable speed compressor to modulate cooling capacity. The FDD system was designed to consider transient load conditions. Four major faults were considered, and each fault was detected over wide operating load range by separating the system response to the load change. Rule-based method was used to diagnose and classify the system faults. From the experimental results, COP degradation due to the faults in a variable speed system is severer than that in a constant speed system. The method developed in this study can be used in the fault detection of refrigeration systems with a variable speed compressor.

A Study for Measurement of the Fuel Surface Temperature in Hybrid Rocket (하이브리드 로켓에서의 연료 표면 온도 측정에 관한 연구)

  • Kim, Hak-Chul;Woo, Kyoung-Jin;Lee, Jung-Pyo;Kim, Gi-Hun;Cho, Jung-Tae;Kim, Soo-Jong;Moon, Hee-Jang;Sung, Hong-Gye;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.237-240
    • /
    • 2009
  • To estimate the surface temperature for the hybrid solid fuels correctly is very important for the modelling of the hybrid combustion. Because it is used for the calculation of regression rate. In this study, The measurement of the surface temperature were performed with the solid fuels inserted the thermocouple. Its variation was investigated in the range of mass flux for an oxidizer.

  • PDF

Dielectric Characteristics of $Ta_2O_5$ Thin Films Prepared by ECR-PECVD (ECR-플라즈마 화학 증착법에 의해 제조된 $Ta_2O_5$ 박막의 유전 특성)

  • 조복원;안성덕;이원종
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.11
    • /
    • pp.1330-1336
    • /
    • 1994
  • Ta2O5 films were deposited on the p-Si(100) substrates by ECR-PECVD and annealed in O2 atmosphere. The thicknesses of Ta2O5/SiO2 layers were measured by an ellipsometer and a cross-sectional TEM. Annealing in O2 atmosphere enhanced the stoichiometry of the Ta2O5 film and reduced the impurity carbon content. Ta2O5 films were crystallized at the annealing temperatures above 75$0^{\circ}C$. The best leakage current characteristics and the maximum dielectric constant of Ta2O5/SiO2 film capacitor were observed in the specimen annealed at $700^{\circ}C$ and 75$0^{\circ}C$, respectively. The flat band voltage of the Al/Ta2O5/SiO2/p-Si MOS capacitor was varied in the range of -0.6~-1.6 V with the annealing temperature. The conduction mechanism in the Ta2O5 film, the variation of the effective oxide charge density with the annealing temperature, and the effective electric field distribution in the Ta2O5/SiO2 double layer were also discussed.

  • PDF

Development of A X-band 12 W High Power Amplifier MMIC (X-대역 12-W 급 고출력증폭기 MMIC 개발)

  • Chang, Dong-Pil;Noh, Youn-Sub;Lee, Jeong-Won;Ahn, Ki-Burm;Uhm, Man-Seok;Yom, In-Bok;Na, Hyung-Ki;Ahn, Chang-Soo;Kim, Sun-Joo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.446-451
    • /
    • 2009
  • In this paper, we described the design and test results of a high output power amplifier MMIC developed by using 0.5um power pHEMT processes on a 6-inch GaAs wafer for the X-band T/R module application. In the MMIC design, we have used a simple on-chip gate active bias technology to compensate the threshold-voltage variation of pHEMT during the fabrication process and 16-to-1 power combining method to achieve the output power over 10watt. The fabricated chip has an output power over 12watts and maximum PAE of 32% over the frequency range of fo +/-750MHz.

Design and Fabrication of Broadband Phase Shifter Based on Vector Modulator (벡터 모듈레이터형 광대역 위상 변위기의 설계 및 제작)

  • 류정기;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.7
    • /
    • pp.734-740
    • /
    • 2003
  • In this paper, A Vector Modulator based a wideband analog phase shifter is realized with four P-I-N diode attenuators, an asymmetric coupled line coupler, a symmetric coupled line coupler, and a power combiner. Simple configuration to have advantages in cost, size, power, and the number of passive circuits is presented. The phase variation due to phase and amplitude error of a P-I-N diode attenuator is derived and used to optimize the overall circuit. The phase shifter shows a total phase shift of 360$^{\circ}$, a 8.2$^{\circ}$maximum phase error, and a 16${\pm}$2.5 dB insertion loss over the wide frequency range of 1 GHz to 3 GHz.