• Title/Summary/Keyword: Range of variation

Search Result 3,245, Processing Time 0.032 seconds

The Characteristic of Control Response of BLDC using a Fuzzy PI Controller (퍼지 PI 제어기를 사용한 BLDC 제어 응답특성)

  • Yoon, Yong-Ho;Kim, Jae-Moon;Kim, Duk-Heon;Won, Chung-Yuen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1978-1983
    • /
    • 2011
  • BLDC motor is used in a wide variety of industrial and servo applications. Its features and advantages mainly consist in high value of torque/inertia ratio, high efficiency with speed range and high dynamic performance. This paper deals with the speed control of a trapezoidal type brushless DC motor using Fuzzy PI controller. The conventional PI controller has been widely used in industrial applications. If we select a optimal PI control gain, the PI controller shows very good control performance. But it is very difficult to find the optimal PI control gain. Fuzzy control does not need any model of plant and is basically adaptive and gives robust performance for plant parameter variation. Therefore the combinations of conventional PI controller and fuzzy controller seem to be very effective. This paper deals with PI controller with 4-rule based fuzzy controller. The proposed fuzzy PI controller increases the control performance of the conventional PI controller. Simulation and experimental results show that fuzzy PI controller has a good robustness regarding the improper tuned PI controller.

Fabrication and Microstructure/Properties of Bulk-type Tantalum Material by a Kinetic Spray Process (Kinetic Spray 공정을 이용한 벌크형 탄탈륨 소재의 제조 및 미세조직/물성)

  • Lee, Ji-Hye;Kim, Ji-Won;Lee, Kee-Ahn
    • Journal of Powder Materials
    • /
    • v.23 no.1
    • /
    • pp.8-14
    • /
    • 2016
  • A bulk-type Ta material is fabricated using the kinetic spray process and its microstructure and physical properties are investigated. Ta powder with an angular size in the range $9-37{\mu}m$ (purity 99.95%) is sprayed on a Cu plate to form a coating layer. As a result, ~7 mm-sized bulk-type high-density material capable of being used as a sputter material is fabricated. In order to assess the physical properties of the thick coating layer at different locations, the coating material is observed at three different locations (surface, center, and interface). Furthermore, a vacuum heat treatment is applied to the coating material to reduce the variation of physical properties at different locations of the coating material and improve the density. OM, Vickers hardness test, SEM, XRD, and EBSD are implemented for analyzing the microstructure and physical properties. The fabricated Ta coating material produces porosity of 0.11~0.12%, hardness of 311~327 Hv, and minor variations at different locations. In addition, a decrease in the porosity and hardness is observed at different locations upon heat treatment.

High-Speed SD-OCT for Ultra Wide-field Human Retinal Three Dimensions Imaging using GPU (병렬처리 그래픽 기술 기반의 Spectral Domain-Optical Coherence Tomography를 이용한 3차원 광 대역 망막 촬영)

  • Park, Kibeom;Cho, Nam Hyun;Wijesinghe, Ruchire Eranga Henry;Kim, Jeehyun
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.135-140
    • /
    • 2013
  • We have developed an ultra wide-field of view Optical Coherence Tomography(OCT) which has capability to 2D and 3D views of cross-sectional structure of in vivo human retina. Conventional OCT has a limitation in visualizing the entire retina due to a reduced field of view. We designed an optical setup to significantly improve the lateral scanning range to be more than 20 mm. The entire human retinal structure in 2D and 3D was reported in this paper with the developed OCT system. Also, we empirically searched an optimized image size for real time visualization by analyzing variation of the frame rate with different lateral scan points. The size was concluded to be $1024{\times}2000{\times}300$ pixels which took 9 seconds for visualization.

Structural and Magnetic Properties of Fe50Cr50 Alloys Prepared by Mechanical Alloying Method

  • Yang, Dong-Seok;Park, Ji-Yeon;Yoo, Yong-Goo;Kim, Kyeong-Sup;Yu, Seong-Cho
    • Journal of Magnetics
    • /
    • v.15 no.3
    • /
    • pp.108-111
    • /
    • 2010
  • Fe50Cr50 metastable alloys were prepared by the mechanical alloying method with milling periods of 1, 2, 4, 6, 12 and 24 hours, respectively. The structural evolution was analyzed by the extended x-ray absorption fine structure (EXAFS). In this work, the EXAFS analysis provided the local structural information around Fe central atom. The saturation magnetization was also measured by VSM. The magnetization decreased as the process mechanical alloying progressed. The magnetic property was related to the local structural variation as a function of processing time. The analysis showed that the diffusion Cr atoms into Fe clusters caused the reduction of magnetization. EXAFS analysis exhibited that the local ordering of magnetic atoms caused the magnetic ordering. Also, EXAFS analysis showed that the long range order of Fe atoms was destroyed completely in 24 hour milling.

A Study on Pre-bonding of 3C-SiC Wafers using CVD Oxide (CVD 절연막을 이용한 3C-SiC 기판의 초기직접접합에 관한 연구)

  • ;;Shigehiro Nishino
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.10
    • /
    • pp.883-888
    • /
    • 2002
  • SiC direct bonding technology is very attractive for both SiCOI(SiC-on-insulator) electric devices and SiC-MEMS(micro electro mechanical system) fields because of its application possibility in harsh environments. This paper presents pre-bonding techniques with variation of HF pre-treatment conditions for SiC wafer direct bonding using PECVD(plasma enhanced chemical vapor deposition) oxide. The PECYD oxide was characterized by XPS(X-ray photoelectron spectrometer) and AFM(atomic force microscopy). The characteristics of the bonded sample were measured under different bonding conditions of HF concentration and an applied pressure. The bonding strength was evaluated by the tensile strength method. The bonded interface was analyzed by using SEM(scanning electron microscope). Components existed in the interlayer were analyzed by using FT-IR(fourier transform infrared spectroscopy). The bonding strength was varied with HF pre-treatment conditions before the pre-bonding in the range of 5.3 kgf/cm$^2$to 15.5 kgf/cm$^2$.

Mean energy of electrons in $SF_6$-Ar Mixtures Gas ($SF_6$-Ar 혼합기체(混合氣體)의 전자(電子) 평균(平均)에너지)

  • Kim, Sang-Nam;Seong, Nak-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.75-78
    • /
    • 2003
  • Energy distribution function for electrons in $SF_6$-Ar mixtures gas used by MCS-BEq algorithm has been analysed over the E/N range $30\sim300$[Td] by a two term Boltzmann equation and by a Monte Carlo Simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2[%] and 0.5[%] $SF_6$-Ar mixtures were measured by time-of-flight(TOF) method. The results show that the deduced electron drift velocities, the electron ionization or attachment coefficients, longitudinal and transverse diffusion coefficients and mean energy agree reasonably well with theoretical for a rang of E/N values. The transport coefficients for electrons in (0.2[%])$SF_6$-Ar and (0.5[%]$SF_6$ - Ar mixtures were measured by time-of-flight method, and the electron energy distribution function and the parameters of the velocity and the diffusion were determined by the variation of the collision cross-sections with energy. The results obtained from Boltzmann equation method and Monte Carlo simulation have been compared with present and previously obtained data and respective set of electron collision cross sections of the molecules.

  • PDF

Theoretical and Experimental Considerations for Improving Elastomer Drug Infusers (탄성체 약물주입기 개선을 위한 이론적·실험적 고찰)

  • Kim, Dong Hoon;Kang, Taewon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.3
    • /
    • pp.320-327
    • /
    • 2017
  • The main function of an infuser is to ensure constant dosage of a drug. Elastomer drug infusers have been used widely owing to their economic advantages. The mechanism of the device is primarily based on the pressure created from the elastic material that contains the drugs. However, as the drug is infused and the internal pressure is reduced, the drug is not linearly infused at all times. This study involves investigating factors to improve the design of the infuser. The first factor is the range of proper deformation, which does not affect a significant amount of stress variation during infusion. The second is concerned with the flow restrictor and the associated design variables are recommended by employing finite element analysis and the factorial experiment technique. The last factor is related to the spring device connected to balloon. The results showed that the drug reservoir can compensate for unexpected pressure gradient drops.

Lack of KRAS Gene Mutations in Chronic Myeloid Leukemia in Iran

  • Kooshyar, Mohammad Mahdi;Ayatollahi, Hossein;Keramati, Mohammad Reza;Sadeghian, Mohammad Hadi;Miri, Mohsen;Sheikhi, Maryam
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6653-6656
    • /
    • 2013
  • Background: The single most common proto-oncogene change in human neoplasms is a point mutation in RAS genes. A wide range of variation in frequency of KRAS mutations has been seen in hematologic malignancies. Despite this, RAS roles in leukemogenesis remain unclear. The frequency of KRAS mutations in CML has been reported to be between zero an 10%. Many attempts have been done to develop an anti-RAS drug as a therapeutic target. Materials and Methods: This cross sectional study was performed in Mashhad University of Medical Sciences, Mashhad, Iran from 2010-2012. In 78 CML patients (diagnosed according to WHO 2008 criteria) in chronic or accelerated phases, KRAS mutations in codons 12 and 13 were analyzed using a modified PCR-restriction fragment length polymorphism (RFLP) method. Results: We did not detect any KRAS mutations in this study. Conclusions: KRAS mutations are overall rare in early phase CML and might be secondary events happening late in leukemogenesis cooperating with initial genetic lesions.

Effect of Temperature on the Critical Micelle Concentration of Decylpyridinium Chloride (Decylpyridinium Chloride 용액의 Critical Micelle Concentration에 미치는 온도의 영향)

  • Han Man-Woon;Lee Chong-Man
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.4
    • /
    • pp.201-204
    • /
    • 1972
  • The critical micelle concentrations of decylpyridinium chloride in aqueous solutions have been determined by the electrical conductance measurements in the range of $10^{\circ}C$-$50^{\circ}C$. The temperature variation of the critical micelle concentrations has shown the minimum at the vicinity of $15^{\circ}C$. The Clausius-Clapeyron type equation of log (c.m.c.) versus temperature has been established. The values ${\Delta}Hm$ and the other thermodynamic properties associated with micelle formation have been determined using the above equation and compared with that of dodecylpyridinium chloride and dodecylpyridinium bromide.

  • PDF

Vertical variations of heavy metals in tailings site of the Sangdong W mine, Korea

  • Jung Myungchae;Jung Moonyoung;Choi Yunwang;Kang Manhee
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.511-514
    • /
    • 2003
  • The objective of this study is to investigate the vertical variation of heavy metals in tailings from the Sangdong W mine. Tailings samples were taken at 6 drilling sites with 50cm intervals up to 21 meters in depth and dried at room temperature. The pH value, loss-on-ignition and water contents were measured. In addition, chemical compositions of the samples were determined by AAS after 0.1 N HCl leaching and ICP-AES after aqua regia leaching. The pH values were in the range of 7.4 to 9.5 due to chemical reactions of carbonate minerals. The ranges of heavy metals (mg/kg) extracted by 0.1N HCl were from 0.17 to 0.93 for Cd, 0.04 to 4.39 for Cu, 0.03 to 10.9 for Pb and 0.06 to 14.1 for Zn and those extracted by aqua regia were $3.10\~10.5,\;23.61\~251,\;63.7\~337\;and\;42.6\~134$ for Cd, Cu, Pb and Zn, respectively. Generally, the metal concentrations in tailings extracted by 0.1N HCl decreased with depth, whilst those extracted by aqua regia have a tendency to increase with depth in some case. Those trends might be due to the change of oxidation-reduction condition of the tailings.

  • PDF