• Title/Summary/Keyword: Range Correlation Effect

Search Result 493, Processing Time 0.023 seconds

A Study on the Simulation Method of the Code Correlation Range (코드상관 거리측정센서의 시뮬레이션 기법 연구)

  • Kim, Ung-Sik;Kang, Byoung-Moo;Kim, Wan-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.459-461
    • /
    • 1997
  • This paper describes a simulation method of the correlation-signal output, which has Doppler effect (variation of amplitude, phase, and frequency) caused by the moving-effect of target and encounter conditions. Using these results, we can develope and verify the algorithm of the signal processing parts of the code correlation range sensor with ease.

  • PDF

A GENERALIZATION OF THE INTRACLASS CORRELATION IN CLUSTER SAMPLING

  • KIM KYU-SEONG
    • Journal of the Korean Statistical Society
    • /
    • v.34 no.3
    • /
    • pp.185-195
    • /
    • 2005
  • This article is concerned with the intraclass correlation in survey sampling. From a design-based viewpoint the intraclass correlation is generalized to a finite population with unequal sized clusters. Under simple random cluster sampling the intraclass correlation is given in an explicit form, which is a generalization of the usual one. The range of it is found and the design effect is expressed by means of it. An example is given to compare the intraclass correlation with the homogeneity measure numerically, which shows that two measures are not the same except some limited cases.

Performance Analysis of the UHF RFID Reader with the Range Correlation Effects of the Phase Noise (위상 잡음의 거리 상관 효과에 따른 UHF RFID 리더의 성능 분석)

  • Jang, Byung-Jun;Kang, Min-Soo;Lim, Jae-Bong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.152-160
    • /
    • 2008
  • In this paper, we analyze the performance of a direct-conversion UHF RFID reader with the range correlation effects of the phase noise. Since a UHF RFIB system uses the same oscillator to generate the transmitted carrier and the local oscillation, the periodic interference and phase noise reduction effects occur due to time delay between two signals. Through exact theory and simulation, we verify how to cancel the periodic interference phenomena using I/Q diversity combining technique. And, we analyze phase noise reduction effects due to range correlation as a function of the tag-reader distance and the offset frequency Using these results, we simulate the symbol-error-rate performance with respect to phase noise with and without range correation effects. We show that the phase noise of the local oscillator has little effect on the symbol-error-rate performance because of phase noise reduction by range correlation.

Correlation of Convective Boiling Heat Transfer in a Horizontal Tube for Pure Refrigerants and Refrigerant Mixtures (순수 및 혼합냉매의 유동증발 열전달 상관식)

  • Shin, J.Y.;Kim, M.S.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.254-266
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants(R22, R32, R125, R134a, R290, and R600a) and refrigerant mixtures(R32/R134a and R290/R600a) are measured experimentally and compared with several correlations. Convective boiling term of Chen's correlation predicts experimental data for pure refrigerants fairly well(root-mean-square error of 12.1% for the quality range over 0.2). An analysis of convective boiling heat transfer of refrigerant mixtures is performed for an annular flow to study degradation of heat transfer. Annular flow is the subject of this analysis because a great portion of the evaporator in refrigeration or air conditioning system is known to be in the annular flow regime. Mass transfer effect due to composition difference between liquid and vapor phases, which is considered as a driving force for mass transfer at interface, is included in this analysis. Correction factor $C_F$ is introduced to the correlation for the pure substances through annular flow analysis to apply the correlation to the mixtures. The flow boiling heat transfer coefficients are calculated using the correlation considering nucleate boilling effect in the low quality region and mass transfer effect for nonzazeotropic refrigerant mixtures.

  • PDF

The Correlation between Groundwater Level and the Moving Average of Precipitation considering Snowmelt Effect and Critical Infiltration in Han River Watershed (융설효과와 한계침투량을 고려한 한강유역의 지하수위와 강우이동평균간의 상관관계)

  • Yang, Jeong-Seok;Kim, Nam-Ki
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.313-321
    • /
    • 2009
  • The relationship between precipitation and groundwater level and the correlation between the moving average of precipitation and goundwater level were analyzed for the Han river watershed in Korean peninsular. Fourteen regions in the watershed were selected and there were somewhat different patterns of seasonal fluctuation of groundwater level data. The groundwater level data tends to decrease in dry spell and increase in wet spell however the range between maximum and minimum values is quite different for each gauging point. We could have stronger correlation between groundwater level for fractured rock aquifer and the moving average of precipitation than the groundwater level for alluvial aquifer. The critical infiltration, which is the maximum daily infiltration averaged throughout watershed, value is turned out to have the range of 10 to 90 mm. We could have stronger correlation when we consider critical infiltration and modify the original precipitation data than we use original precipitation data. We also could have higher correlation coefficient when we consider snowmelt effect for the watershed that has considerable snow event.

A study of the correlation coefficients with respect to the degrees of the global models in the kriging metamodel (크리깅 메타모델에서 전역 모델에 따른 상관계수의 연구)

  • Cho, Su-Kil;Lee, Tae-Hee
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.701-705
    • /
    • 2008
  • Design analysis and computer experiments (DACE) model is widely used to express efficiently the nonlinear responses in the field of engineering design. Kriging model, a DACE model, can approximately replace a simulation model that is very expensive or highly nonlinear. The kriging model is composed of the summation of a global model and a local model representing deviation from global model. The local model is determined by correlation coefficient of the pre-sampled points, where determination of the correct correlation coefficient has an effect on accuracy and robustness of the kriging model. Therefore, robustness of the correlation coefficient is explored with respect to degrees of the global model. Then we propose the range of correlation coefficient to make correct and robust kriging model and the influence of the correlation coefficients on the degrees of global model with respect to the nonlinearity of the pre-sampled responses.

  • PDF

Simulations of Two-Dimensional Electronic Correlation Spectra

  • Kim, Hak Jin;Jeon, Seong Jun
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.8
    • /
    • pp.807-815
    • /
    • 2001
  • Two-dimensional (2D) correlation method, which generates the synchronous and the asynchronous 2D spectrum by complex cross correlation of the Fourier transformed spectra, is an analysis method for the changes of the sample spectrum induced by vari ous perturbations. In the present work, the 2D electronic correlation spectra have been simulated for the cases where the sample spectrum composed of two gaussian bands changes linearly. When only the band amplitudes of the sample spectrum change, the synchronous spectrum shows strong peaks at the band centers of the sample spectrum, but the asynchronous spectrum does not make peaks. When the sample spectrum shifts without changing intensity and width, the synchronous spectrum shows peaks around the initial and final positions of the band maximum and the asynchronous spectrum shows long peaks spanning the shifting range. The band width change produces the complex 2D correlation spectra. When the sample spectrum shifts with band broadening, the width change by 50% of full width at half maximum (FWHM) does not give so large an effect on the correlation spectrum as the spectral shift by one half of FWHM of the sample spectrum.

Dietary Thiamin Intake and TPP Effect of Elderly Women

  • Jung, Eun-Hee;Han, Kyung-Hee
    • Journal of Community Nutrition
    • /
    • v.2 no.2
    • /
    • pp.141-145
    • /
    • 2000
  • The present study was conducted to assess the dietary and nutritional status of thiamin in fourty-two elderly women. Dietary intake was determined by 24hour recall method and nutritional status of thiamin was determined by measurement of transketolase activity in erythrocytes. Average dietary intake of energy and thiamin were found to be low, and not more than 78% and 63.2% of Recommended dietary allowances(RDA) respectively. Transketolase activity in erythrocytes was distributed in the range of 0.227-0.589mU/mgHb and the mean value and 0.434mU/mgHb. The mean value of Thiamin pyrophosphate effect(TPP effect) was 24.0% and the range was from 9.36% to 83.9%. It appeared that 95% of 42 elderly women were severely or marginally deficient in thiamin status, showing 22 persons to be above 20% and 18 persons to be 15-20% of TPP effect. Transketolase activity and TPP effect did not show any significant correlation with dietary thiamin intake.

  • PDF

Analysis of Rheological Properties of Cement Paste with Binder Type and Composition Ratio (결합재 타입 및 구성비 변화에 따른 시멘트 페이스트의 레올로지 특성 분석)

  • Jeon, Sung IL;Nam, Jeong Hee;Lee, Moon Sup;Nho, Jae Myun
    • International Journal of Highway Engineering
    • /
    • v.19 no.5
    • /
    • pp.77-88
    • /
    • 2017
  • PURPOSES : It is necessary to clarify the rheological properties of cement paste as a basic research in the development of mechanistic concrete mix design. The rheological properties of cement paste with different binder types, mix propositions, and with/without high range water reducers have been analyzed. METHODS : In this study, ordinary Portland cement, fly-ash, blast furnace slag, silica fume, and limestone powder were used as binders. The range of water-binder ratio was 0.3-0.5, and a total of 30 different mixes have been tested. The slump flow test, V-funnel test, and Dynamic Shear Rheometer (DSR) test were performed to analyze the rheological properties of cement paste. RESULTS : As a result of the slump flow test, it was found that the composition ratio of the binder contents greatly affected the paste flow when the high range water reducers were added. The results of V-funnel test showed that when the water-binder ratio was decreased without high range water reducers, the binder composition ratio had a large effect on the passing time of the V-funnel tester, but with high range water reducers the impact of the binder composition ratio was decreased. The slump flow and V-funnel have a certain relationship with the rheological factors (yield stress and plastic viscosity), but the correlation was not significant. Finally, we proposed the M-value considering the density and specific surface area of the binder. The correlation between rheological factors and M-value were better demonstrated than experimental values, but there is still a limit to predict the rheological factor in general mix design. CONCLUSIONS :In this study, the rheological properties of cement paste were analyzed. The binder type, composition ratio of binder, and with/without high range water reducers have combined to provide the complex effects on the rheological properties of cement paste. The correlation between the proposed M-value and rheological factor was found to be better than experimental results, but needs to be improved in the future.

Boiling Heat Transfer Characteristics of R-290 in Horizontal Smooth Minichannel (수평미세관내 R-290의 비등열전달 특성)

  • Choi, Kwang-Il;Pamitran, A.S.;Oh, Jong-Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.906-914
    • /
    • 2006
  • The present paper dealt with an experimental study of boiling heat transfer characteristics of R-290. Pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel were obtained with inner tube diameter of 3.0 mm and length of 2,000 mm. The direct electric heating method was applied for supplying a heat to the refrigerant uniformly. The experiments were conducted with R-290 purity of 99.99%, at saturation temperature of 0 to $10^{\circ}C$, a mass flux range of $50{\sim}250kg/m^2s$, and a heat flux range of $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increased with increasing mass flux and saturation temperature, wherein the effect of mass flux was higher than that of the saturation temperature. Heat flux has a low effect on the increasing of heat transfer coefficient. The heat transfer coefficient was compared with six existing heat transfer coefficient correlations. The Zhang et al.'s correlation (2004) gave the best prediction of heat transfer coefficient. A new correlation to predict the two-phase flow heat transfer coefficient was developed based on the Chen correlation. The new correlation predicted the experimental data well with a mean deviation of 11.78% and average deviation of -0.07%.