• Title/Summary/Keyword: Range Accuracy

Search Result 2,670, Processing Time 0.025 seconds

Remote Measurements of the Geological Structures, Using Photogrammetric Method (입체사진을 이용한 원거리 면구조 측정)

  • Hwang Sang-Gi
    • The Journal of Engineering Geology
    • /
    • v.15 no.2 s.42
    • /
    • pp.201-212
    • /
    • 2005
  • A photogrammetric camera system and a software have been built for capturing planned stereo images. To evaluate the system,25 planar data from a constructed rock slope were measured using both geological compass and photo system. Comparison of the data groups from both system showed matching relationship that falls within the error range of $5.25\pm4.53$ in strike and $3.18\pm3.17$ in dip angles, when the 2 standard deviation error distributions were considered. To evaluate the errors of the Photo matching and non planarity of the surface, orientations of the same plane were repeatedly measured 20times. These measurements showed error ranges of $8.2\pm3.4$in strike and $6.6\pm3.4$ in dip angle, considering the same error distributions. Measured strikes and dips were compared with the corresponding compass measurements in 5 constructed. slopes to test the system. Stereonet plots showed that the photo system measured data coincided well with the compass measurements. With these evaluations, the photo system can measure the planar structure in inaccessible locations with reliable accuracy at the same time reducing the data gathering period therefore resulting to an efficient geological survey.

Source Apportionment and Chemical Characteristics of Atmospheric PM2.5 in an Agricultural Area of Korea (농촌지역 대기 중 PM2.5의 화학적 특성과 오염원 정량 평가)

  • Jeong, Jin-Hee;Lim, Jong-Myoung;Lee, Jin-Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.5
    • /
    • pp.431-446
    • /
    • 2018
  • In this study, chemical characteristics of $PM_{2.5}$ samples collected in an agricultural area in Nonsan of Korea were investigated focusing on of black carbon, 3 inorganic ions and 22 trace elements. It was found that the relative error and relative standard deviation of many trace elements fell below 10%, which indicates good analytical accuracy and precision. The mean values of $PM_{2.5}$ in an agricultural area were exceeded by new Korean air quality standard of March 2018. The concentration of $PM_{2.5}$ was well correlated with those of black carbon and ions. The concentrations of trace elements were in a wide range of seven orders of a magnitude. Based on these $PM_{2.5}$ data sets, a total of 6 sources were identified using PMF (Positive Matrix Factorization; secondary aerosol (34.4%), soil/road dust (20.1%), biomass burning (16.9%), incineration/fuel combustion (13.2%), vehicle exhaust(12.2%), sea-salt (3.17%). Results of our study indicate that it is very important to control illegal burning activities in agricultural area.

Multiresidue Determination of Tetracyclines in Eggs using Liquid Chromatography with Ultraviolet Detection (액체크로마토그래피를 이용한 계란 중 테트라사이클린계 항생물질의 동시분석법 개발)

  • Lee, Sang-Hee;Shim, You-Sin;Choi, Yoon-Hee;Lee, Beom-Gil;Kim, Hyun-Ju;Shin, Dong-Bin
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.4
    • /
    • pp.370-374
    • /
    • 2007
  • An analytical method for the simultaneous determination of four tetracycline (oxytetracycline, tetracycline, chlortetracycline, doxycycline) in egg samples was developed and validated using liquid chromatography with ultraviolet detection. Egg samples were extracted by the liquid-liquid extraction based on acetonitrile. The chromatographic separation was achieved on a reverse phase C8 column with gradient elution using a mobile phase of 20 mM oxalic acid (pH 1.5)/acetonitrile. The procedure was validated according to the Food Drugs Administration guideline determining accuracy, precision, and limit of detection. Mean recovery of tetracyclines from spiked egg samples (50, 100, 200, 400, and $800{\mu}g/kg$) were 78.8-109.3%. Linearity in concentration range of $50-800{\mu}g/kg$ was obtained with the correlation coefficient $(r^2)$ of 0.994-0.999. The intra- and inter-day precision (relative standard deviation; RSD) was between 0.3-12.8 and 0.2-11.7%, respectively. Limit of detection (LOD) and limit of quantification (LOQ) for the investigated tetracyclines were 30 and $50{\mu}g/kg$ depending on egg samples, respectively. This method was reliable, sensitive, economical and suitable for routine monitoring of tetracycline residues in dairy egg.

Analysis on Force Tracking Capabilities of Healthy Adults (정상인 힘 추적 능력 분석)

  • Lee, Baekhee;Park, Hyunji;Kim, Sungho;Lee, Byung Wha;Na, Duk L.;You, Heecheon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.2
    • /
    • pp.121-127
    • /
    • 2015
  • A reduction of motor performance due to brain disorders can be screened by evaluating force tracking capabilities (FTCs). Existing studies have examined FTCs mainly using simple sinusoidal waves, of which repeated profiles have a critical limitation due to a learning effect in force tracking. The present study examined the effects of personal factors (age and gender) and sinusoidal wave factors (central force and complexity) on FTCs of healthy adults using composite sinusoidal wave profiles (CSWPs). FTCs were measured using Finger $Touch^{TM}$ for 30 seconds and quantified in terms of time within the target range (TWR, accuracy measure) and relative RMSE (RRMSE, variability measure). A total of 90 healthy adults in 20s to 70s with the equal gender ratio participated in the experiment consisting of combinations of 2 central force levels (6 N and 10 N) and 2 complexity levels (approximate entropy, ApEn = 0.03 and 0.06) of CSWPs. Significantly decreased FTCs (lower TWR and higher RRMSE) were found in aged adults, females, the low central force, and the high complexity. The detailed FTC decrements include a 43% reduced TWR and a 85% increased RRMSE of older adults in 70s as compared to those in 20s, a 17% reduced TWR and a 17% increased RRMSE of female as compared to those of male, a 30% reduced TWR and a 108% increased RRMSE at central force = 6N when compared to those at central force = 10N, and a 19% reduced TWR and a 30% increased RRMSE at ApEn = 0.06 as compared to those at ApEn = 0.03. The characteristics of FTCs for CSWPs can be of use in establishing an assessment protocol of motor performance for screening brain disorders.

Comparative Reliability Evaluation on Semantic Service Platforms (시맨틱 서비스 플랫폼상에서의 신뢰성 비교 평가)

  • Jung, Han-Min;Lee, Mi-Kyoung;You, Beom-Jong;Kim, Do-Wan
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.1
    • /
    • pp.105-109
    • /
    • 2010
  • While numerous information services are provided on the Web as a core infrastructure of information society, semantic services using the Semantic Web technologies still stay deployed number and application range. This situation would be mainly originated from the failure of securing reliability to the user. Thus, this paper introduces an evaluation method for measuring reliabilities of the semantic services comparatively. To measure the reliability of the compared systems, the observer assesses 'precision in task performance' as a quantitative analysis and 'reliability of expectation-result' as a qualitative analysis described by the test persons. On the other hand, the test person should rate the functional reliability and reliability of the served information on the vector graph by himself with a scale from 0 to 5. Experimental results show that assessment by the observer is very similar to rating value by test persons, and that the accuracy of the served information has a close effect on the functional reliability. Through this paper, we can verify the essential factors for evaluating the reliability of semantic service systems. These are functional reliability and reliability of served information resulting from function execution. In particular, it has been proven that the reliability of the semantic information services largely influences the "Quality in Use" and therefore determines the major factors of the semantic service reliability.

The Study about Measuring Method in Radius of Eyeglasses Lens Curvature by using Keratometer (각막곡률계를 이용한 안경렌즈 곡률반경 측정방법에 관한 연구)

  • Cha, Jung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.127-133
    • /
    • 2012
  • Perpose: The aim of this study is to investigate the measuring method in radius of eyeglasses lens curvature by using keratometer in noncontact method. Methods: A trial lens for vision test in diopter range from -9.00 D to -11.50 D were attached in front part of keratometer, after that we set eyeglasses lens at the place where eyeglasses lens is apart about 25 cm from front position of keratometer. We measured the radius of curvature from observation of clear mire image while the position of eyeglasses lens is changed in a small quantity. After that, we made some formulas for compensation of radius of curvature by using spherometer. Results: The radius of curvature was successfully measured by keratometer with trial lens in front part of it. The measured radius of curvature was changed to compensation value using spherometer data, and the 5 kind of linear equation to make compensation value was made. Any kind of lenses measured by using keratometer that trial lens was attached in front part of it, after that it was confirmed that the result of calculation from line equation is exact in error ratio below 3.5%. Conclusions: It was confirmed that radius of eyeglasses lens curvature can be measured by using keratometer by noncontact method, and the accuracy is higher than "lens measure".

Development and Validation Test of Effective Wet Scavenging Contribution Regression Models Using Long-term Air Monitoring and Weather Database (장기간 대기오염 및 기상자료를 이용한 유효강수세정 기여율 회귀모델의 개발 및 유효성 검사)

  • Lim, Deukyong;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.3
    • /
    • pp.297-306
    • /
    • 2013
  • This study used long-term air and weather data from 2000 to 2009 as raw data sets to develop regression models in order to estimate precipitation scavenging contributions of ambient $PM_{10}$ and $NO_2$ in Korea. The data were initially analyzed to calculate scavenging ratio (SR), defined as the removal efficiency for $PM_{10}$ and $NO_2$ by actual precipitation. Next, the effective scavenging contributions (ESC) with considering precipitation probability density were calculated for each sector of precipitation range. Finally, the empirical regression equations for the two air pollutants were separately developed, and then the equations were applied to test the model validity with the raw data sets of 2010 and 2011, which were not involved in the modeling process. The results showed that the predicted $PM_{10}$ ESC by the model was 23.8% and the observed $PM_{10}$ ESCs were 23.6% in 2010 and 24.0% in 2011, respectively. As for $NO_2$, the predicted ESC by the model was 16.3% and the observed ESCs were 16.4% in 2010 and 16.6% in 2011, respectively. Thus the developed regression models fitted quite well the actual scavenging contribution for both ambient $PM_{10}$ and $NO_2$. The models can then be used as a good tool to quantitatively apportion the natural and anthropogenic sink contribution in Korea. However, to apply the models for far future, the precipitation probability density function (PPDF) as a weather variable in the model equations must be renewed periodically to increase prediction accuracy and reliability. Further, in order to apply the models in a specific local area, it is recommended that the long-term oriented local PPDF should be inserted in the models.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Fexofenadine in Human (테르페나딘 체내동태 연구를 위한 혈청 중 펙소페나딘의 HPLC 정량법 개발 및 검증)

  • Cho, Hye-Young;Kang, Hyun-Ah;Kim, Yoon-Gyoon;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.6
    • /
    • pp.437-443
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of a major metabolite of terfenadine, fexofenadine, in human serum was developed, validated, and applied to the pharmacokinetic study of terfenadine. Fexofenadine and internal standard, haloperidol were extracted from human serum by liquid-liquid extraction with acetonitrile and analyzed on a $Symmetry^{TM}$ C8 column with the mobile phase of 1% triethylamine phosphate (pH 3.7)-acetonitrile (67:33, v/v, adjusted to pH 5.6 with triethylamine). Detection wavelength of 230 nm for excitation, 280 nm for emission and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed fexofenadine concentration (50 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 10-500 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 10 ng/mL, which was sensitive enough for the pharmacokinetic studies of terfenadine. The overall accuracy of the quality control samples ranged from 95.70 to 114.58% for fexofenadine with overall precision (% C.V.) being 3.53-14.39%. The relative mean recovery of fexofenadine for human serum was 90.17%. Stability studies (freeze-thaw, short-term, extracted serum sample and stock solution) showed that fexofenadine was stable during storage, or during the assay procedure in human serum. However, the storage at $-70^{\circ}C$ for 4 weeks showed that fexofenadine was not stable. The peak area and retention time of fexofenadine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of fexofenadine in human serum samples for the pharmacokinetic studies of orally administered Tafedine tablet (60 mg as terfenadine) at three different laboratories, demonstrating the suitability of the method.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Fenoprofen in Human (페노프로펜 체내동태 연구를 위한 혈청 중 페노프로펜의 HPLC 정량법 개발 및 검증)

  • Cho, Hye-Young;Kang, Hyun-Ah;Kim, Yoon-Gyoon;Sah, Hong-Kee;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.6
    • /
    • pp.423-429
    • /
    • 2005
  • A selective and sensitive reversed-phase HPLC method for the determination of fenoprofen in human serum was developed, validated, and applied to the pharmacokinetic study of fenoprofen calcium. Fenoprofen and internal standard, ketoprofen, were extracted from human serum by liquid-liquid extraction with diethyl ether and analyzed on a Luna C18(2) column with the mobile phase of acetonitrile-3 mM potassium dihydrogen phosphate (32:68, v/v, adjusted to pH 6.6 with phosphoric acid). Detection wavelength of 272 nm and flow rate of 0.25 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed fenoprofen concentration $(2\;{\mu}g/mL)$ with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of $0.05-100\;{\mu}g/mL$ with correlation coefficients greater than 0.999. The lower limit of quantification using 1 mL of serum was $0.05\;{\mu}g/mL$, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 92.27 to 109.20% for fenoprofen with overall precision (% C.V.) being 5.51-11.71 %. The relative mean recovery of fenoprofen for human serum was 81.7%. Stability (freeze-thaw, short and long-term) studies showed that fenoprofen was not stable during storage. But, extracted serum sample and stock solution were allowed to stand at ambient temperature for 12 hr prior to injection without affecting the quantification. The peak area and retention time of fenoprofen were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of fenoprofen in human serum samples for the pharmacokinetic studies of orally administered Fenopron tablet (600 mg as fenoprofen) at three different laboratories, demonstrating the suitability of the method.

Simultaneous Determination of Urinary Phytoestrogens and Estrogens by Gas Chromatography/Mass spectrometry (GC/MS에 의한 뇨 중 Phytoestrogen과 Estrogen의 동시 분석)

  • Yang, Yoon Jung;Lee, Seon Hwa;Chung, Bong Chul
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.374-385
    • /
    • 1998
  • Phytoestrogens are biologically active compounds derived from plants foods. It had been suggested that phytoestrogens, by inhibiting aromatase in peripheral and/or cancer cells and lowering estrogen levels, may play a protective role as antipromotional compounds during growth of estrogen-dependent cancers. Therefore, simultaneous analysis of estrogens and phytoestrogens is necessary to elucidate the possible involvement of phytoestrogens in estrogen metabolism. In this view, we developed a simple and reproducible procedure to quantitatively determine estrogen and phytoestrogen metabolites. The proposed method consisted of solid phase extraction using preconditioned Serdolit AD-2 resin, enzyme hydrolysis with ${\beta}$-glucuronidase/arylsulfatase from Helix pomatia, liquid-liquid extraction and TMS-ether derivatization. And the final determination was carried out by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring mode (SIM). The precision and accuracy of this method was evaluated through within-a-day and day-to-day test. Recovery range and detection limit were 71.96~105.66%, 2~4 ng/mL, respectively. Using this method, 17 estrogen and 5 phytoestrogen compositions in urine of normal subjects were analyzed. It was found that amounts and relative distribution of urinary phytoestrigens and estrogens showed different pattern in male and female subjects.

  • PDF