• Title/Summary/Keyword: Range

Search Result 62,217, Processing Time 0.076 seconds

Electroglottographic Spectral Tilt in Frequency Ranges of Vowel Sound (모음 주파수 범위에 따른 성문전도 스펙트럼 기울기)

  • Kim, Ji-Hye;Jang, Ae-Lan;Jung, Dong-Keun
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.247-251
    • /
    • 2015
  • In this study, electroglottographic spectral tilt (EST) was investigated for characterization of vocal cords vibration. EST was analyzed from the power spectrum of electroglottographic signals by dividing frequency analysis range as full range (0~4 octave), low range (0~2 octave), and high range (2~4 octave). EST of all ranges in female were greater than those in male. In female and male groups, EST of high range was higher than that of low range. This result suggests that EST has at least two components and dividing frequency range in analysis of EST is effective for investigating characteristics of vocal cords vibration.

Audiological Benefits in Dynamic Range Compression Hearing Aids (가청범위압축방식 보청기의 청각학적 이득에 관한 연구)

  • Heo, Seung-Deok;Kim, Lee-Suk;Jung, Dong-Keun;Ko, Do-Heung;Park, Byung-Gun
    • Speech Sciences
    • /
    • v.11 no.2
    • /
    • pp.19-25
    • /
    • 2004
  • Hearing aids play an very important role in aural rehabilitation for hearing impaired person who could not be medically treated. Especially, hearing aids with dynamic range compression (level dependent frequency response: LDFR) method concentrated dynamic output range of receiver into the narrowing dynamic range of sensorineural hearing impaired person. Thus, if aided hearing threshold level is improved and uncomfortable loudness level rises, then the users of hearing aids are favored with extended dynamic range. This study aims to evaluate audiological benefits in dynamic range compression hearing aids. To achieve this, pure tone and speech audiometry were examined to 15 children and 3 adults with narrow dynamic range moderate-to-severe binaural sensorineural hearing loss.

  • PDF

A Study on the accuracy of Rangefinder between vessels by use of GPS (GPS를 이용한 선간거리계의 정확도에 관한 연구)

  • 김광홍
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.215-226
    • /
    • 1999
  • The experimented rangefinder consist of sets of V/A-Code GPS and sets of L1 C/A-code & carrier phase receivers connected by two spread spectrum radio modems in order to measure relative range and bearing between two ship antennas by real time, comparing and analyzing accuracy of both GPS receivers at the fix point on the land by means of executing zero baseline test by C/A code and by carrier phase as well as measuring distance range 5m, 10m, 15m between each other receivers. The results from the measurement of relative range and bearing are as follows as ;1. According to the results from zero baseline test, the average error by C/A-code receiver is less than 0.1m, which proves theories from published books but when each GPS receivers track different satellites, the range accuracy error becomes up to 100m by means of S/A. Because of this sudden wide range error, rangefinder is not appropriate at relative range measurement without additional modification of the algorism of the GPS receiver itself.2. According to relative range measurement by Carrier Phase and zero baseline test at static condition, the range error is less than 3.5cm in case that it passes more than 5 minutes after GPS sets can track simultaneously more than 6 satellites. Its main reason is understood that the phase center of antenna is bigger than geodetic antenna.3. When range measurement of two receivers from 5m, to 10m to 15m, the each range error is 0.340m, 0.190m, 0.011m and each standard variation is 0.0973m, 0.0884m, 0.0790m. The range error and standard variation are in inverse proportion to distance between two receivers. 4. L1 Carrier Phase GPS generally needs 5 minutes to fix and during this ambiguity search, the relative range and bearing angle is shown to be various.

  • PDF

Antenna Test Range for Telecommunication Satellite (통신위성용 안테나 테스트 레인지)

  • Lim, Seong-Bin;Kim, Tae-Youn;Choi, Seok-Won;Sim, Eun-Sup
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.52-59
    • /
    • 2007
  • Telecommunication satellite consists of a bus system and an RF payload system with high efficiency and high gain reflector antennas. Antenna measurement and also RF system performance (antenna under test, payload and satellite level) have to be evaluated enough before launching in the far-field range or equivalent test range. Basically far-field range is required in a range from two hundred meters to several kilo meters, and it is highly constrained to the externa1 environment, like the RF and the whether environment So the compact antenna test range is developed and used efficiently without external environments as in-door facility. This paper describes the configuration of the compact antenna test range, the range error, and the physical concept of the plane wave illumination Also, it provides a overall design of the anechoic chamber and range parameter values to accommodate the precision measurements in antenna test range.

  • PDF

Influence of Intravenous Contrast Medium on Proton range and SOBP(Spread-Out Bragg peak) (조영제 사용이 양성자 Range와 SOBP(Spread-Out Bragg peak)에 미치는 영향)

  • Kim, Ho Sik;Choi, Seung Oh;Kim, Eun Sook;Jeon, Sang Min;Youm, Doo Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.183-189
    • /
    • 2014
  • Purpose : Intravenous contrast medium is a substance used to enhance the contrast of normal tissues or malignant tissues within the body. For this reason, intravenous contrast media have been extensively used form treatment-planning CT. However, when the patient is receiving proton therapy, there is no contrast medium in that moment. In this study, evaluate the influence of intravenous contrast medium on proton range and Spread-Out Bragg peak(SOBP) in Treatment Planning System(TPS). Materials and Methods : Hounsfield Unit(HU) value were measured by 20 liver cancer patients with phase change. and evaluate the proton range and SOBP on 5 liver proton treatment plan. By using the hand made water phantom measure the proton range and SOBP on proton treatment plan with changing HU and Depth. Results : Changing value(Pre contrast, Arterial phase, Portal phase) in liver cancer patient were ($58{\pm}5.7$, $75{\pm}9.5$, $117{\pm}14.6$ for liver tissue) and ($40{\pm}6.1$, $279{\pm}49.0$, $154{\pm}22.8$ for aorta), respectively. The mean difference of range was 2.5mm and SOBP was 1.4mm according to HU change. In phantom study, proton range was shorter and SOBP was narrowed with increasing HU. Conclusion : We verify that HU change lead to range and SOBP change in TPS. Additional study is required to verify that change of HU make range and SOBP be changed in actual substance.

A Study on the Effective Method to Producing Data for The ROKA Live Fire Training Range Safety (한국군 실 사격 훈련간 효율적인 안전지대 데이터 구축 방안 연구)

  • Lee, June-Sik;Choi, Bong-Wan;Oh, Hyun-Seung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.3
    • /
    • pp.64-77
    • /
    • 2015
  • An effective method for produce munitions effectiveness data is to calculate weapon effectiveness indices in the US military's Joint Munitions Effectiveness Manuals (JMEM) and take advantage of the damage evaluation model (GFSM) and weapon Effectiveness Evaluation Model (Matrix Evaluator). However, a study about the Range Safety that can be applied in the live firing exercises is very insufficient in the case of ROK military. The Range Safety program is an element of the US Army Safety Program, and is the program responsible for developing policies and guidance to ensure the safe operation of live-fire ranges. The methodology of Weapon Danger Zone (WDZ) program is based on a combination of weapon modeling/simulation data and actual impact data. Also, each WDZ incorporates a probability distribution function which provides the information necessary to perform a quantitative risk assessment to evaluate the relative risk of an identified profile. A study of method to establish for K-Range Safety data is to develop manuals (pamphlet) will be a standard to ensure the effective and safe fire training at the ROK military education and training and environmental conditions. For example, WDZs are generated with the WDZ tool as part of the RMTK (Range Managers Tool Kit) package. The WDZ tool is a Geographic Information System-based application that is available to operational planners and range safety manager of Army and Marine Corps in both desktop and web-based versions. K-Range Safety Program based on US data is reflected in the Korean terrain by operating environments and training doctrine etc, and the range safety data are made. Thus, verification process on modified variables data is required. K-Range Safety rather than being produced by a single program, is an package safety activities and measures through weapon danger zone tool, SRP (The Sustainable Range Program), manuals, doctrine, terrain, climate, military defence M&S, weapon system development/operational test evaluation and analysis to continuously improving range safety zone. Distribution of this K-range safety pamphlet is available to Army users in electronic media only and is intended for the standing army and army reserve. Also publication and distribution to authorized users for marine corps commands are indicated in the table of allowances for publications. Therefore, this study proposes an efficient K-Range Safety Manual producing to calculate the danger zones that can be applied to the ROK military's live fire training by introducing of US Army weapons danger zone program and Range Safety Manual

Development and validation of Speech Range Profile task (발화범위 프로파일 과제 개발 및 타당성 검증)

  • Kim, Jaeock;Lee, Seung Jin
    • Phonetics and Speech Sciences
    • /
    • v.11 no.3
    • /
    • pp.77-87
    • /
    • 2019
  • The study aimed to develop Speech Range Profile (SRP) and to examine and validate its clinical application. Forty-five participants without voice disorders aged 18-29 years were compared using SRP and Voice Range Profile (VRP). The authors developed the "Fire!" paragraph as a SRP task compromising 14 sentences including all Korean spoken phonemes and sentence types. To compare SRP and VRP results, the participants read the paragraph (reading) and counted from 21 to 30 (counting) as a part of SRP tasks, and produced a vowel /a/ from low to high frequencies (gliding) and a shortened form of the VRP as a part of VRP tasks. $F0_{max}$, $F0_{min}$, $F0_{range}$, $I_{max}$, $I_{min}$, and $I_{range}$ for each task were measured and compared, showing that $F0_{max}$, $F0_{min}$, $F0_{range}$, $I_{max}$, and $I_{range}$ were not different between reading and gliding. $I_{min}$, had the lowest value in counting. It is concluded that the newly developed SRP task, reading the "Fire" paragraph, can yield a maximum phonation range similar to that found by VRP. Therefore, it is expected that voice evaluation can be effectively performed in a relatively short time by applying SRP with the "Fire" paragraph, a functional utterance task, in place of VRP, which may be difficult to measure long term or in cases of severe voice disorders.

An active system for unnecessary noise reduction in kitchen range hoods

  • Kim, Eunhee;Jang, Jaechun;Lim, Changmok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.3
    • /
    • pp.91-96
    • /
    • 2016
  • We have surrounded undesired living noises in our life. One of biggest noises coming out of range hood during cooking in the kitchen. A range hood is one of the most important appliances in the kitchen because it ventilates polluted air out during cooking, and maintains air quality in the kitchen. But current kitchen range hoods bring up some issues; First, the range hoods consume massive amount of standby power not in use condition. Second, current models have designed manual fan operating system with sudden onset of noise with starting. In this paper, we propose an auto control system entire processes from air ventilation to noise reduction. Our system is consist of three parts (Eco-sensors pack, Main Controller and Active Noise Controller); Eco-sensors pack detects air pollution of kitchen areas and sends the detection values to Main Controller. Main Controller determines operation of range hood by detected values. Active Noise Controller is located inside of the range hood. It received starting signals from Main Controller which elicits degrees of polluted air condition and fan operating speed from 1 to 3. Once Active Noise Controller detected the signals, it runs a ventilating fan until new value from Main Controller becomes 0. while the range hood works, A noise cancellation algorithm inside of Active Noise Controller become activated to reduce levels of noise. As a result, the proposed system clearly shows reduction in power consumption include standby power and decreases in levels of noise.

A Study of Reportable Range Setting through Concentrated Control Sample (약물검사에서 관리시료의 농축을 이용한 보고 가능 범위의 설정에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Choi, Ho Sung;Park, Yong Won;Yun, Keun Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • This study was designed to establish working range for reoportable range in own laboratory in order to cover the upper and lower limits of the range in test method. We experimented ten times during 10 days for setting of reportable range with between run for method evaluation. It is generally assumed that the analytical method produces a linear response and that the test results between those upper and lower limits are then reportable. CLIA recommends that laboratories verify the reportable range of all moderate and high complexity tests. The Clinical Laboratory Improvement Amendments(CLIA) and Laboratory Accreditation Program of the Korean Society for Laboratory Medicine states reportable range is only required for "modified" moderately complex tests. Linearity requirements have been eliminated from the CLIA regulations and from others accreditation agencies, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. It is important to assess the useful reportable range of a laboratory method, i.e., the lowest and highest test results that are reliable and can be reported. Manufacturers make claims for the reportable range of their methods by stating the upper and lower limits of the range. Instrument manufacturers state an operating range and a reportable range. The commercial linearity material can be used to verify this range, if it adequately covers the stated linear interval. CLIA requirements for quality control, must demonstrate that, prior to reporting patient test results, it can obtain the performance specifications for accuracy, precision, and reportable range of patient test results, comparable to those established by the manufacturer. If applicable, the laboratory must also verify the reportable range of patient test results. The reportable range of patient test results is the range of test result values over which the laboratory can establish or verify the accuracy of the instrument, kit or test system measurement response. We need to define the usable reportable range of the method so that the experiments can be properly planned and valid data can be collected. The reportable range is usually defined as the range where the analytical response of the method is linear with respect to the concentration of the analyte being measured. In conclusion, experimental results on reportable range using concentrated control sample and zero calibrators covering from highest to lowest range were salicylate $8.8{\mu}g/dL$, phenytoin $0.67{\mu}g/dL$, phenobarbital $1.53{\mu}g/dL$, primidone $0.16{\mu}g/dL$, theophylline $0.2{\mu}g/dL$, vancomycine $1.3{\mu}g/dL$, valproic acid $3.2{\mu}g/dL$, digitoxin 0.17ng/dL, carbamazepine $0.36{\mu}g/dL$ and acetaminophen $0.7{\mu}g/dL$ at minimum level and salicylate $969.9{\mu}g/dL$, phenytoin $38.1{\mu}g/dL$, phenobarbital $60.4{\mu}g/dL$, primidone $24.57{\mu}g/dL$, theophylline $39.2{\mu}g/dL$, vancomycine $83.65{\mu}g/dL$, valproic acid $147.96{\mu}g/dL$, digitoxin 5.04ng/dL, carbamazepine $19.76{\mu}g/dL$, acetaminophen $300.92{\mu}g/dL$ at maximum level.

  • PDF

Anatomical Differences of the Fibular Incisura of the Tibia between Ankle Fracture with Syndesmotic Injury and without Syndesmotic Injury (족관절 골절 환자에서 원위 경비 인대 결합 손상 유무에 따른 경골의 비골 구에 대한 해부학적 차이)

  • Kim, Hyong-Nyun;Kim, Soo-Bum;Park, Yong-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.2
    • /
    • pp.150-155
    • /
    • 2008
  • Purpose: This study was performed to compare the anatomic differences of the fibular incisura of the tibia between ankle fractures with and without syndesmotic injuries. Materials and Methods: 42 patients were involved in this study: Group I was composed with 14 cases of ankle fractures with syndesmotic injuries; Group II was composed with 14 cases of ankle fractures without syndesmotic injuries; Group III was composed with 14 cases of volunteers. The height averaged 170.1 cm (range, $159{\sim}181$ cm) in group I, 168.9 cm (range, $156{\sim}184$ cm) in group II, and 170.4 cm (range, $161{\sim}77$ cm) in group III. The mean height did not show a statistically significant difference between groups (p>0.05). All patients were taken axial computed tomography. The length of anterior and posterior facets, angle between anterior and posterior facet, and depth of the fibular incisura of the tibia were measured. Results: The mean length of the anterior facet was 11.5 mm (range, $9.2{\sim}15.7$ mm) in group I, 12.2 mm (range, $7.3{\sim}17.0$ mm) in group II, and 10.3 mm (range, $8.7{\sim}14.0$ mm) in group III (p>0.05). The mean length of the posterior facet was 12.3 mm (range, $9.0{\sim}14.5$ mm) in group I, 11.0 mm (range, $7.3{\sim}16.2$ mm) in group II, and 13.0 mm (range, $9.2{\sim}15.9$ mm) in group III (p>0.05). The mean angle between anterior and posterior facet was 139.1 degrees (range, $125.5{\sim}154.0$ degrees) in group I, 144.2 degrees (range, $134.7{\sim}152.6$ degrees) in group II, and 131.5 degrees (range, $117.6{\sim}144.4$ degrees) in group III (p<0.05). The mean depth of the fibular incisura of the tibia was 4.1 mm (range, $3.2{\sim}15.8$ mm) in group I, 4.6 mm (range, $3.1{\sim}7.1$ mm) in group II, and 3.1 mm (range, $1.5{\sim}4.0$ mm) in group III (p<0.05). Conclusion: There are some statistical differences of angle between anterior and posterior facet and depth of the fibular incisura of the tibia between ankle fractures with and without syndesmotic injuries.

  • PDF