• 제목/요약/키워드: Ramp rate

검색결과 129건 처리시간 0.026초

Improvement of Critical Current In Bi-2223/Ag HTS Tapes by the Bubbling Control

  • 하홍수;오상수;하동우;이남진;김상철
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.247-251
    • /
    • 2002
  • In general, the bubbling, generated during the fabrication of the tapes, breaks the superconducting filament, and critical current of the tapes will be decreased. Heat-treatment schemes of Bi-2223/Ag HTS tapes were modified, such as pre-annealing of multi-stacked billet, 2-step main sintering and ramp rate etc. The generation of bubbling was drastically decreased from 20 bubbles/m to 0 ~ 1 bubble/m by the modified heat-treatment. Therefore, the value of critical current of the tapes without bubbling was increased almost twice higher than that of already existing tapes. Critical current up to 42 A in 40 m length Bi-22231Ag tapes have been measured at 77K, self-field, 1$mutextrm{V}$/cm criterion. It could be confirmed that elimination of bubbling is effective to maintain the superconducting property along the tape length.

  • PDF

장애인편의시설 외부접근 공간 개선을 위한 기초조사 연구 (A Preliminary Study for the Outdoor Accessibility Improvement on The Handicapped Facilities)

  • 김대희;이강희;장정희
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.97-100
    • /
    • 2005
  • The handicapped as a member of a society should possess the same opportunity of a perfect participation in public affairs and an equal opportunity in parity of treatment. All sorts of physical and social barriers surrounding the handicapped who can not having a impairment and disability give a less chance to have a share in their society. Therefore, this discrimination barriers must be phased off not only by handicapped but also by normal social members so as to perfect and free access to movement, all of social institution and social activities. Therefor, this paper provides a basic data which conducts investigation and analysis on the outdoor access environment for the handicapped's easy access to public building or facilities. It would be most import rules to make a decision between improvement rate and object for public building or public facilities.

  • PDF

대구경 초전도 코일의 ?치 전류 특성 (Characteristics of the Quench Current of Superconducting Coils with Large Bore)

  • 조전욱;배준한;김해종;심기덕;성기철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권6호
    • /
    • pp.368-371
    • /
    • 2004
  • The quench current characteristics of the superconducting solenoids with large diameter were experimentally investigated. Three solenoids with inside diameter of 450mm were fabricated with different tensions and different types of epoxy applications. The quench current of each solenoid was measured according to the various ramping rates of current. The highest quench current was obtained in the solenoid impregnated with epoxy after winding with tension of 20 percents of the yield strength of the superconducting wire. It was found that the quench currents were almost independent of the ramp rate of current. From the results, although the training effect in the solenoid appeared with epoxy impregnation, the quench current of solenoid impregnated with epoxy was higher than that without epoxy impregnated The test results are presented and discussed.

Designing Test Methods for IT-Enabled Energy Storage System to Evaluate Energy Dynamics

  • Kim, Young Gon;Kim, Dong Hoon;Lee, Eun-Kyu
    • Journal of Information Processing Systems
    • /
    • 제13권6호
    • /
    • pp.1487-1495
    • /
    • 2017
  • With increasing interests in renewables, more consumers are installing an energy storage system (ESS) in their backyards, and thus, the ESS will play a critical role in the emerging smart grid. Due to mechanical properties, however its operational dynamics must be well understood before connecting the ESS to the smart grid (and eventually to an IT system). To this end, we investigate charging and discharging processes in detail. This paper, then, proposes methods for four type tests (state of charge test, conversion efficiency test, response time test, and ramp rate test) that can assess the dynamics of the ESS. The proposed methods can capture accurate delay values of mechanical processes in the ESS, and it is expected for those values to help design real-time communication systems in the smart grid involving the ESS.

Lessons Learned from Energy Storage System Demonstrations for Primary Frequency Control

  • Yu, Kwang-myung;Choi, In-kyu;Woo, Joo-hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권2호
    • /
    • pp.107-114
    • /
    • 2018
  • In recent years, ESS (Energy Storage System) has been widely used in various parts of a power system. Especially, due to its fast response time and high ramp rate, ESS is known to play an important role in regulating grid frequency and providing rotational inertia. As the number of installed and commercially operating ESSs increases, the reliability becomes an important issue. This paper introduces control schemes and presents its test method for grid-connected ESS for primary frequency regulation. The test method allows to verify the control operation in the individual operation mode and state. A validation of the method through actual ESS test in a electrical substation is presented in the case study section.

비만여성의 지방연소를 위한 최적운동강도에 관한 연구 (A Study on the Optimal Exercise Intensity for the Fat Oxidation of Fat Women)

  • 최영덕;오경환;임종수
    • 대한물리치료과학회지
    • /
    • 제8권2호
    • /
    • pp.1039-1045
    • /
    • 2001
  • The aim of this study is to show the results which we analyse the interrelation among the physiological variable elements. We survey thirty fat women who don't do exercise regularly and are thirties. in order to offer basic data for setting the optimal exercise intensity through the efficient fat oxidation. We use RAMP II protocol of the Ever Green Hospital. The results are followings: 1. When the optimal exercise intensity for fat oxidation is done, there's a meaningful relation among the fat oxidation, $O_2$ max, and respiratory change. 2. When the optimal exercise intensity for fat oxidation is done, there's no meaningful relation statistically in $O_2$ max, heart rate, respiratory change, and caloric rate. 3. When the optimal exercise intensity for fat oxidation is done, there's a meaningful difference among three groups in %$VO_2$ max. However, there's a meaningful difference between group C and group A. B, and there's no meaningful difference between group B and group A.

  • PDF

Nano-Mechanical and Tribological Characteristics of Ultra-Thin Amorphous Carbon Film Investigated by AFM

  • Chung, Koo-Hyun;Lee, Jae-Won;Kim, Dae-Eun
    • Journal of Mechanical Science and Technology
    • /
    • 제18권10호
    • /
    • pp.1772-1781
    • /
    • 2004
  • The mechanical as well as tribological characteristics of coating films as thin as a few nm become more crucial as applications in micro-systems grow. Especially, the amorphous carbon film has a potential to be used as a protective layer for micro-systems. In this work, quantitative evaluation of nano-indentation, scratching, and wear tests were performed on the 7nm thick amorphous carbon film using an Atomic Force Microscope (AFM). It was shown that AFM-based nano-indentation using a diamond coated tip can be feasibly utilized for mechanical characterization of ultra-thin films. Also, it was found that the critical load where the failure of the carbon film occurred was about 18${\mu}$N by the ramp load scratch test. Finally, the wear experimental results showed that the quantitative wear rate of the carbon film ranged 10$\^$-9/~10$\^$-8/ ㎣ /N cycle. These experimental methods can be effectively utilized for a better understanding the mechanical and tribological characteristics at the nano-scale.

전하주입조건에 따른 비휘발성 MNOS 기억소자의 기억유지특성에 관한 연구 (A Study on the Retention Characteristics with the Charge Injection Conditions in the Nonvolatile MNOS Memories)

  • 이경륜;이상배;이상은;서광열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1265-1267
    • /
    • 1993
  • The switching and the retention characteristics with the injection conditions(pulse height and pulse width) were investigated in the nonvolatile MNOS memories with thin oxide layer of $23{\AA}$ thick. The shift of flatband voltage was measured using the fast ramp C-V method and experimental results were analized using the previously developed models. It was shown that the experimental results were described quit well by the trap-assisted and modified Fowler-Nordheim tunneling models for the voltage pulse of $15V{\sim}19V,\;24V{\sim}25V$, respectively. However, the direct tunneling model was agreement with experimental values in all range of pulse height. As increasing the initial shift of the flatband voltage, the decay rate was increased. But for the same initial shift of the flatband voltage, the decay rate was smaller for low and long pulse than for high and short one.

  • PDF

ATM망에서 신속한 폭주통지 기능을 지닌 멀티캐스트 ABR 흐름제어 알고리즘의 성능비교 (Performance Comparison of Multicast ABR Flow Control Algorithms with Fast Overload Indication in ATM Networks)

  • 김동호;김병철;조유제;권율
    • 한국정보과학회논문지:정보통신
    • /
    • 제27권1호
    • /
    • pp.98-107
    • /
    • 2000
  • 본 논문에서는 멀티캐스트 가용비트율 (Available Bit Rate: ABR) 서비스를 위해 현재 ATM 포럼 등을 통해 제안되고 있는 신속한 폭주 통지 (fast overload indication) 기능을 기존 피드백통합 알고리즘들에 적용하여 이들의 성능을 시뮬레이션을 통해 비교 분석하였다. 성능 분석의 지표로 송신원의 허용된 셀률 (Allowed Cell Rate: ACR), 스위치에서의 큐 길이, 링크 이용 효율, 공평성, 역방향 자원관리 셀 (Backward Resource Management: BRM) 셀의 오버헤드 등을 사용하였다. 분석 결과, 신속한 폭주 통지 기능이 추가된 피드백 통합 알고리즘들은 망에 심각한 폭주가 발생한 경우에 매우 효과적임을 알 수 있었다. 신속한 폭주 통지 기능은 기본적인 피드백 통합 알고리즘에 관계없이 쉽게 추가될 수 있는 반면에, 이러한 기능이 추가된 알고리즘들의 성능은 기본적인 피드백 통합 알고리즘들의 성능에 매우 의존적임을 알 수 있었다.

  • PDF

수소 저장용 탱크의 튜브 형상에 따른 온도분포 특성에 대한 수치해석 연구 (A Study on the Characteristics of Temperature Distribution Related to Geometry of Tube in Hydrogen Storage Vessel)

  • 오승준;윤정환;전경숙;김재규;박준홍;최정주
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.205-211
    • /
    • 2021
  • Recently, it is necessary for study on renewable energy due to environmental pollution and fossil fuel depletion. Therefore, in this study, the filling temperature according to the nozzle geometry was evaluated based on the limit temperature specified in SAEJ2601 for charging hydrogen, a new energy. There are three types of nozzles, normal, angle and round, fixed the average pressure ramp rate at 52.5 MPa/min, and the injection temperature was set at 293.4 K. As a result, the lowest temperature distribution was found in the round type, although the final temperature did not differ significantly in the three types of nozzles. In addition, Pearson's coefficient was calculated to correlate the mass flow rate with the heat transfer rate at the inner liner wall, which resulted in a strong linear relationship of 0.98 or higher.