• Title/Summary/Keyword: Rainwater storage tank

Search Result 27, Processing Time 0.024 seconds

Rainwater Harvesting System as an Alternative Water Source

  • Kim, Phil-S.;Yoo, Kyung-H.;Kim, Sun-Joo;Lee, Nam-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.524-528
    • /
    • 2009
  • The objectives of this study were to install RCR systems at a typical single family house and a school in Alabama, and evaluate the feasibility and efficiency of using the RCR systems for water harvesting in Alabama. The RCR systemswere equipped with a control system and a CR10X data logger to monitor the system operation and to collect data on precipitation, temperature, overflow, water depth in the storage tank and daily uses of toilet flushing. Daily average water use of the home for toilet flushing was 95 liter and 2100 liter was used at the school during the school days. Rainwater harvesting efficiency was 83.3 and 89 percent and RCR use efficiency was 18 and 98 percent from the home and the school, respectively. A computer program was developed to estimate potential effectiveness of RCR systems. From the analysis result with 10 years rainfall data, a total of 67,000 liters of rainwater could be harvested for domestic uses from a typical single family house which supplies 190 liters per day.

  • PDF

The effect of Temperature Reduction of Green roof for building energy-saving using Rainwater Storage Tank (건물 에너지 절약을 위한 저류 옥상 녹화의 온도 저감 효과)

  • Yun, Seok-hwan;Kim, Eun-sub;Piao, Zheng-gang;Kim, Sang-hyuck;Kim, Na-yeon;Hwang, Hye-mee;Je, Sang-woo;Kang, Han-min;Ham, Eun-kyung;Lee, Dong-kun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.26 no.4
    • /
    • pp.51-59
    • /
    • 2023
  • Despite countries' efforts to reduce carbon emissions, carbon emissions have increased in recent decades along with energy use, of which building energy uses account for a large proportion. Energy savings are essential as a strategy to reduce carbon emissions in existing buildings. The field experiment on the roof of a building located in Seoul was designed to measure the temperature reduction effect of green roof with rainwater storage tank to reduce cooling energy consumption in summer. The results showed that the mean mean surface temperature under the green roof was 14.77 degrees lower than that of the non-green roof from 13:00 P.M. to 15:00 P.M., which would have a great effect on reducing cooling energy. From 01:00 A.M. to 03:00 A.M., the effect was 3.36 degrees, showing that tropical nights could be improved. The temperature reduction effect due to the rainwater storage system increased by 1.45 degrees during the day and decreased by 0.63 degrees at night. The storage system can be strategically utilized to reduce carbon emissions during the week when cooling energy increases significantly.

Development of a Long-slope Water Harvesting System in Natural Channel for Drought Mitigation in Upland (밭작물 가뭄피해 경감을 위한 소류천 유출수 저수 시스템 개발)

  • Kim, Youngjin;Choi, Yonghun;Lee, Sangbong;Kim, Minyoung;Jeon, Jonggil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.6
    • /
    • pp.111-118
    • /
    • 2020
  • This study developed a rainwater harvesting system for the irrigation of upland on sloping area. The assessment of water supply capacity was evaluated in farm field experience. This system consists of a water catchment device and a collapsible storage tank. The water catchment device was designed to collect runoff water in natural channel of 500 mm width into a pipe of 50 mm inner diameter. The device has funnel-shaped plan and cross-section of square. The storage capacity of the collapsible water tank was caculated to meet the water demand for irrigation in 30 a cultivated land for 10-year frequancy drought. The tank has a cuboid shape with a capacity of 30 ㎥, 5 m in width and length, 1.2 m in height. This system can supply 92% of the water required for drop irrigation of red pepper and 88% of the water required for drop irrigation of onions in 30 a cultivation land during the month of May and June. In the case of 16-dry days of 10-years frequency, this system is capable to irrigate 100% of required water for red pepper and onion, 76.7% of required water for Omija (Schisandra chinensis), and 51.5% of required water for autumn kimchi cabbage.

Comparison of rainwater utilization rate according to actual capacity-standard capacity of storage tank of rainwater harvesting system (빗물이용시설 저류조 실제용량-기준용량에 따른 빗물이용률 비교)

  • Sim, Inkyeong;Park, Yoonkyung;Kim, Reeho;Park, Jongpyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.418-418
    • /
    • 2022
  • 본 연구에서는 수문학적 물수지 분석을 통한 물수요-공급 시계열 분석을 수행하여 빗물이용률을 산정하였다. 물수지 분석 도구를 개발하였으며, 이를 통해 빗물이용시설 공급충족률(필요수량 대비 빗물이용량), 빗물보장률(전체일수 대비 빗물이용일수), 빗물이용률(빗물이용시서용량 대비 빗물이용가능량)에 대해 분석을 수행하였다. 업무시설, 학교, 체육시설(공원), 공동주택에 대해 수요처별 수요 시나리오를 작성하였으며, 고수요 75%, 중수요 50%, 저수요 25%를 적용하였다. 시나리오별 실제 용량과 기준용량에 따른 빗물이용률을 비교함으로써 현재 설치된 빗물이용시설이 잘 계획되었는지, 과소 계획되었는지 파악할 수 있다. 빗물이용률 분석을 위해 빗물이용시설 유형별 2개소씩 선정하였으며, 빗물이용시설 실제용량 및 기준용량(집수면적(m2)×0.05 적용)에 따른 수요 시나리오별 빗물이용률을 비교하였다. 이와 같이 물수지 분석 도구를 이용하면 다양한 시나리오 적용에 따른 운영 결과를 향후 설치될 빗물이용시설의 설치 이전에 확인하여 최적 운영방안 도출 및 저류조 용량 계획에 참고할 수 있을 것으로 판단된다.

  • PDF

Design and Operation of the Rainwater-Greywater Hybrid System : SNU No. 39 Building (빗물-저농도 오수 하이브리드 시스템의 설계 및 운전 평가 : 서울대 39동)

  • Shim, In-tae;Park, Hyun-ju;Kim, Tschung-il;Jung, Sung-un;Han, Moo-young;Namkung, Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.676-682
    • /
    • 2016
  • In this study, rainwater-greywater hybrid system was installed and operated for 1 year in order to evaluate its water quantity, water quality, and economic efficiency in building no. 39. This system was expected to overcome each disadvantages of and maximize each advantages. Low-greywater that was washed up from shower room was treated by MBR (Membrane Bioreactor) and ozone oxidation. Rainwater that was collected from the rooftop was stored in a reservoir, and then transferred to the storage tank that was mixed with treated greywater. After 1 year operating in building no. 39, rainwater and greywater was used to supply $2,599m^3$ of toilet flushing water. In terms of water quality, rainwater was satisfied far the greywater reuse standards except for E.coli. Moreover, low greywater quality was acceptable except for E. coli, BOD, SS, and turbidity. In addition, economic analysis was obtained from benefit-cost ratio (B/C) with 1.11. It implies that the feasibility of the project was reasonable. Furthermore, various research and policy to improve the economic efficiency of water recycling facilities is required to expand the use of water recycling facilities.

A Study on Design of Vacuum Silo for Batch Treatment System for Dredged Soil (준설토 일괄처리시스템을 위한 진공사이로 설계에 관한 연구)

  • Kim, Yong-Seok;Yang, Hae-Rim;Kim, Hac-Sun;Jeoung, Chan-Se;Yang, Soon-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.571-577
    • /
    • 2012
  • In this study, a small movable batch treatment system for dredging soil deposited in a rain water tube is proposed; further, a vacuum silo sorting separation device with a vacuum silo, first-stage sorting separator, and conveyor is designed. The vacuum silo sorting separation device also consists of a storage tank, transferring screw, vacuum gate, screen bar, screen bar cleaner, and vacuum discharging device. In view of the fact that the flow of drawn air in the storage tank is a major factor influencing the sorting separation performance, the optimum shape of the tank is determined by CFD flow analysis. In addition, by using CAE structure analysis, the safety of a storage tank made of boards is examined. The specifications of the vacuum silo sorting separation device are determined by conducting mechanical and dynamic simulations of the driving mechanism of the vacuum silo sorting separation device through 3D-CAD modeling. Following this study, we will design a drum-screen-type second sorter, a decanter-type dehydration device, and waste water tank and pump as a secondary device. Further, on the basis of this design, we will construct a prototype model and carry out a field test.

The effect of Temperature Reduction of Green Roof using Rainwater Storage Tank (빗물 저류 시스템을 활용한 옥상 녹화의 온도 저감 효과)

  • Yun, Seok-Hwan;Kim, Eun-Sub;Piao, Zheng-Gang;Jeon, Yoon-Ho;Kang, Hye-Won;Kim, Sang-Hyuck;Kim, Ji-Yeon;Kang, Han-Min;Ham, Eun-Kyung;Lee, Dong-Kun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.6
    • /
    • pp.109-119
    • /
    • 2021
  • Thermal environment of city is getting worse due to severe urban heat island caused by climate change and urbanization. Green roof improves the urban thermal environment and save the cooling energy in buildings. This study presented a green roof combined with a storage system that stores rain-water and supplies water through a wick and evaluated the temperature reduction effect as surface temperature and amount of evapotranspiration. For about a week, the surface temperature using a infrared thermal imager and the evapotranspiration by recording change of module weight were measured at intervals of 30 minutes from sunrise to sunset. The results show that the mean surface temperature of the green roof was 15.4 degrees lower than that of the non-green roof from 12:00 P.M. to 14:00 P.M. There was no significant difference between mean surface temperature of green roof with and without storage system immediately after rain, but more than a week after rain, there was a difference with average of 2.49 degrees and maximum of 4.72 degrees. The difference in daily amount of evapotranspiration was measured to be 1.66 times on average. As drought stress increased over time, the difference in daily amount of evapotranspiration and surface temperature between with/without storage system increased simultaneously. The results of the study show a more excellent cooling effect of green roof combined with the rainwater storage system.