• Title/Summary/Keyword: Rainwater chemistry

Search Result 17, Processing Time 0.017 seconds

A Study on Chemical Composition of Dustfall Samples in Cheju Area - 1. Chemical composition and deposition (제주지역 강하 먼지의 조성에 관하여 - 1. 화학적 조성 및 침적량)

  • 이기호;허철구;송문호;박용이
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.1
    • /
    • pp.13-22
    • /
    • 1999
  • This study is carried out to investigate the chemical composition of atmospheric deposition in Cheju Island, Korea. For this purpose, dustfall matter samples are collected by dust jar from August, 1995 to July, 1996 at five sampling sites and total suspended particulate matters (TSP) and rain are also collected at one site from October, 1995 to July, 1996. All the samples collected are analyzed, and then the information of the 19 chemical species and deposition amount of each species is obtained. These data are used to determine the regional trends in dustfall chemistry and deposition, and compare the characteristics of chemical compositions between dustfall, TSP and rainwater.

  • PDF

Simulation for the Flowing Water Purification with Spring Shape Inside Chamber (챔버 내측에 스프링형상을 갖는 유수형 자외선 살균장치 시뮬레이션)

  • Jung, Byung-Gyeon;Jeong, Byeong-Ho;Lee, Jin-Jong;Jung, Byeong-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.411-416
    • /
    • 2010
  • Interest in application of ultraviolet light technology for primary disinfection of potable water in drinking water treatment plants has increased significantly in recent years. The efficacy of disinfection processes in water purification systems is governed by several key factors, including reactor hydraulics, disinfectant chemistry, and microbial inactivation kinetics. The objective of this work was to develop a computational fluid dynamics(CFD) model to predict velocity fields, mass transport, chlorine decay, and microbial inactivation in a continuous flow reactor. In this paper, It describe the how to design optimal UV disinfection device for ground water, BWT and rainwater. Spring shape instrument silver coated located in inner side of disinfection chamber. It make lead the active flowing movement target water and maximize disinfection performance. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method, performed simulation and proved satisfied performance.

Chemical Composition of Rainwater in Chonju-city, Korea (전주시에서 채수된 강수의 화학적 조성)

  • 나춘기;정재일
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.5
    • /
    • pp.371-381
    • /
    • 1997
  • Precipitation sampls were collected in Chonju-city during October 1994 to September 1995 and were analysed for major ions (N $a^{+}$, $K^{+}$, $Ca^{2+}$, $Mg^{2+}$, C $l^{[-10]}$ , NO/$_3$, S $O_4$$^{2-}$) and trace metals (Al, Cd, Ni, Pb, Sr, Zn) in addition to pH, in order to understand the chemical characteristics of acid rain and to estimate the origin of the determined ions. Most rain showed a neutral or alkaline character, and only 35% had a pH lower than 5.6. S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ are identified as the primary contributors to precipitation acidity in this region. Neutralization of precipitation acidity occurs as a result of the dissolution of alkaline compounds containing $Ca^{2+}$, $Mg^{2+}$ and $K^{+}$. S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ precipitation concentrations exhibit a seasonal pattern in which higher concentrations are observed during spring months and lower concentrations during summer months. However, the seasonal behavior of $H^{+}$ concentrations differs from this pattern, in that the highest concentrations occur during autumn months, owing to the different influence of neutralization processes. In all rain, S $O_4$$^{2-}$ concentration exceeded NO/$_3$$^{[-10]}$ concentration. The contribution of maritime sources to the total S $O_4$$^{2-}$ concentration was very low or negligible. For rain strongly affacted by yellow sand, $Ca^{2+}$, $Mg^{2+}$ and $K^{+}$ ions show a sharp increase in concentration, reflecting the increased amount of dust and soil suspended in atmosphere. At the same time, S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ concentrations are at their highest levels while $H^{+}$ values are not comparably elevated, presumably beacause much of the acidity has been neutralized by alkaline substances. The seasonal variance of trace metal concentrations in rainwater is similar to that of major cations. The annual wet flux of acidic pollutants and trace metals wat calculated to be as follows: N $O_3$$^{[-10]}$ ; 2.32 g/$m^2$, S $O_4$$^{2-}$, 5.34 g/$m^2$, Al; 6.30 mg/$m^2$, Cd; 0.62 mg/$m^2$, Ni; 4.08 mg/$m^2$, Pb: 9.76 mg/$m^2$, Sr; 5.94 mg/$m^2$, Zn; 111 mg/$m^2$./$m^2$.

  • PDF

Simulation Method for the Flowing Water Purification with UV Lamp (자외선램프을 이용한 유수처리장치 설계 시뮬레이션)

  • Jeong, Byeong-Ho;Lee, Kang-Yeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.17-23
    • /
    • 2009
  • Interest in application of ultraviolet light technology for primary disinfection of potable water in drinking water treatment plants has increased significantly in recent years. The efficacy of disinfection processes in water purification systems is governed by several key factors, including reactor hydraulics, disinfectant chemistry, and microbial inactivation kinetics. The objective of this work was to develop a computational fluid dynamics(CFD) model to predict velocity fields, mass transport, chlorine decay, and microbial inactivation in a continuous flow reactor. The CFD model was also used to evaluate disinfection efficiency in alternative reactor designs. In a typical operation, water enters the inlet of a UV lamp and flows through the annular space between the quartz sleeve and the outside chamber wall. The irradiated water leaves through the outlet nozzle. In this paper, it describe the how to design optimal ultraviolet disinfection device for ground water and rainwater. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method, performed simulation and proved satisfied performance.

Spatio-temporal Water Quality Variations at Various Streams of Han-River Watershed and Empirical Models of Serial Impoundment Reservoirs (한강수계 하천에서의 시공간적 수질변화 특성 및 연속적 인공댐호의 경험적 모델)

  • Jeon, Hye-Won;Choi, Ji-Woong;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.4
    • /
    • pp.378-391
    • /
    • 2012
  • The objective of this study was to determine temporal patterns and longitudinal gradients of water chemistry at eight artificial reservoirs and ten streams within the Han-River watershed along the main axis of the headwaters to the downstreams during 2009~2010. Also, we evaluated chemical relations and their variations among major trophic variables such as total nitrogen (TN), total phosphorus (TP), and chlorophyll-a (CHL-a) and determined intense summer monsoon and annual precipitation effects on algal growth using empirical regression model. Stream water quality of TN, TP, and other parameters degradated toward the downstreams, and especially was largely impacted by point-sources of wastewater disposal plants near Jungrang Stream. In contrast, summer river runoff and rainwater improved the stream water quality of TP, TN, and ionic contents, measured as conductivity (EC) in the downstream reach. Empirical linear regression models of log-transformed CHL-a against log-transformed TN, TP, and TN : TP mass ratios in five reservoirs indicated that the variation of TP accounted 33.8% ($R^2$=0.338, p<0.001, slope=0.710) in the variation of CHL and the variation of TN accounted only 21.4% ($R^2$=0.214, p<0.001) in the CHL-a. Overall, our study suggests that, primary productions, estimated as CHL-a, were more determined by ambient phosphorus loading rather than nitrogen in the lentic systems of artificial reservoirs, and the stream water quality as lotic ecosystems were more influenced by a point-source locations of tributary streams and intense seasonal rainfall rather than a presence of artificial dam reservoirs along the main axis of the watershed.

Spatial and Temporal Variability of Water Quality in Geum-River Watershed and Their Influences by Landuse Pattern (금강 수계의 시.공간적 수질특성과 토지이용도의 영향)

  • Han, Jeong-Ho;Bae, Young-Ju;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.3
    • /
    • pp.385-399
    • /
    • 2010
  • The objective of this study was to analyze long term temporal trends of water chemistry and spatial heterogeneity for 83 sampling sites of Geum-River watershed using water quality dataset during 2003~2007 (obtained from the Ministry of Environment, Korea). The water quality, based on multi-parameters of temperature, dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (SS), total nitrogen (TN), total phosphorus (TP), and electric conductivity (EC), largely varied depending on the landuse patterns, years and seasons. The watershed was classified into three different landuse types: forest stream (Fo), agricultural stream (Ag), and urban stream (Ur). Largest seasonal variabilities in most parameters occurred during the two months of July to August and these were closely associated with large spate of summer monsoon rain. Conductivity, used as a key indicator for an ionic dilution during rainy season, and nutrients of TN and TP had inverse functions of precipitation. BOD, COD decrease during the rainy season. Minimum values in the conductivity, TN, and TP were observed during the summer monsoon, indicating an ionic and nutrient dilution of river water by the rainwater. In contrast, major inputs of suspended solids (SS) occurred during the period of summer monsoon. The landuse patterns analyses, based on the variables of BOD, COD, TN, TP and SS, showed that the values were greater in the agricultural stream (Ag) than in the forest stream (Fo) and urban stream (Ur) and that water quality was worst in the urban stream (Ur). The overall dataset suggest that efficient water quality management, especially in Gap-Stream and Miho-Stream, which showed worst water quality is required along with some of urban stream (Ur), based on the analysis of landuse patterns.

Spatio-temporal Variation Analysis of Physico-chemical Water Quality in the Yeongsan-River Watershed (영산강 수계의 이화학적 수질에 관한 시공간적 변이 분석)

  • Kang, Sun-Ah;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.73-84
    • /
    • 2006
  • The objective of this study was to analyze long-term temporal trends of water chemistry and spatial heterogeneity for 10 sampling sites of the Yeongsan River watershed using water quality dataset during 1995 to 2004 (obtained from the Ministry of Environment, Korea). The water quality, based on multi-parameters of biological oxygen demand (BOD), chemical oxygen demand (COD), conductivity, dissolved oxygen (Do), total phosphorus (TP), total nitrogen (TN) and total suspended solids (TSS), largely varied depending on the sampling sites, seasons and years. Largest seasonal variabilities in most parameters occurred during the two months of July to August and these were closely associated with large spate of summmer monsoon rain. Conductivity, used as a key indicator for a ionic dilution during rainy season, and nutrients of TN and TP had an inverse function of precipitation (absolute r values> 0.32, P< 0.01, n= 119), whereas BOD and COD had no significant relations(P> 0.05, n= 119) with rainfall. Minimum values in conductivity, TN, and TP were observed during the summer monsoon, indicating an ionic and nutrient dilution of river water by the rainwater. In contrast, major inputs of total suspended solids (TSS) occurred during the period of summer monsoon. BOD values varied with seasons and the values was closely associated (r=0.592: P< 0.01) with COD, while variations of TN were had high correlations (r=0.529 : P< 0.01) with TP. Seasonal fluctuations of DO showed that maximum values were in the cold winter season and minimum values were in the summer seasons, indicating an inverse relation with water temperature. The spatial trend analyses of TP, TN, BOD, COD and TSS, except for conductivity, showed that the values were greater in the mid-river reach than in the headwater and down-river reaches. Conductivity was greater in the down-river sites than any other sites. Overall data of BOD, COD, and nutrients (TN, TP) showed that water quality was worst in the Site 4, compared to those of others sites. This was due to continuous effluents from the wastewater treatment plants within the urban area of Gwangju city. Based on the overall dataset, efficient water quality management is required in the urban area for better water quality.