• Title/Summary/Keyword: Rainfall type

Search Result 429, Processing Time 0.025 seconds

The Characteristics of Heavy Rainfall in Summer over the Korean Peninsula from Precipitation Radar of TRMM Satellite : Case Study (TRMM/PR 관측에 의한 한반도에서의 여름철 호우의 특성 : 사례연구)

  • 박혜숙;정효상;노유정
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.1
    • /
    • pp.55-64
    • /
    • 2000
  • The Tropical Rainfall Measuring Mission(TRMM) Satellite was launched in November 1997, carving into orbit the first space-borne Precipitation Radar(PR). The main objective of the TRMM is to obtain and study multi-year science data sets of tropical and subtropical rainfall measurements. In the present investigation, the characteristics of heavy rainfall cases over Korea in 1998 and 1999 are analyzed using the TRMM/PR dat3. We compare the rainrate measured from TRMM/PR with the accumulated rainfall data for 10 minutes tv Automatic Weather System(AWS). Especially, horizontal cross-section of rainrate with height and longitude in the precipitating clouds are investigated. As a result of the comparison with GMS-5 IR1, the TRMM/PR data delineate well the rain type( i.e. convective, stratiform cloud and others), height of storm top and instantaneous rainrate in the precipitating clouds. The vertical structure with height and horizontal cross-section of rainrate along the longitude show the orographic effect on the rainfall. TRMM/PR instrument measures the rainrate below 6 ㎜/hr more than AWS rainguages and inclined to underestimate the rainrate than rainguages for the whole area.

Patterns on Sewer Transfer Flow for Rain Weather Period in the Area with Combined Sewer System for the Management of TMDLs (수질오염총량관리 합류식지역의 우기시 관거이송 변화유형)

  • Park, Jun Dae;Oh, Seung Young;Kim, Ji-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1008-1015
    • /
    • 2010
  • Discharged pollution load is varied as rainfall changes in the area with combined sewer system. Changes in discharged pollution load are directly related with those of sewer transfer flow. Therefore, it is important to identify the pattern of sewer transfer flow for the analysis of changes in discharged pollution load. This study reviewed the type of distribution of sewer transfer flow for 17 sewage treatment plants and developed simple formular to estimate sewer transfer flow as rainfall changes. 11 facilities showed to have some relation with rainfall in the change of sewer transfer flow but 6 facilities to have no relation. Relationships between rainfall amount and sewer transfer flow showed that 6 facilities out of 11 had relatively strong relationships above R2=0.5, which were considered to be affected directly by rainfall changes. The formular which explain the relationship between rainfall and sewer transfer flow can be applied in the analysis of rainfall effects on discharged pollution load, therefore, the more appropriate evaluation will be done.

A Review for Caluculation of the Formula for Probable Rainfall Intensities Following Return Periods in the Hydrological Statistics. -On Cheong-Ju district- (재현기간별 확률 향우강도식 산정에 관한 수문통계학적 고찰-청주 지방을 중심으로-)

  • 이순혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.3
    • /
    • pp.3848-3859
    • /
    • 1975
  • The author attempted to find most suitable formulas for probable rainfall intensities with analysis and consideration for characteristics of rainfall intensities according to the short and long period return periods at Cheong-Joo district. Above mentioned formulas induced by this study can be contributed to the credibility of runoff estimation for urban sewerage system, drainage works in small catchment area and embankment works in the rivers. The results of this study are summarized as follows: 1 Calculation values by Gumbel-Chow method were selected as a mean values for the calculation of probable rainfall intensities according to return periods in the short period. 2. Calculations for probable rainfall intensities for long period are based upon to the result by Iwai's method. Talbot type, {{{{I= {a} over {t+b} }}}} is confirmed as a most suitable formula for probable rainfall intensities among calculation methods in the short periods at Cheong-Joo district. 4. Specific coefficient method, I24=RN24${\beta}$N was selected as a means of calculation for suitable formulas of probable rainfall intensities according to return periods in case of long period. 5. Runoff estimation with high credibility by rational formula can be anticipated by establishment for the most suitable probable rainfall intensities at Cheong-Joo district.

  • PDF

Relationship between Pollutant and Influence Factors in Highway runoff (강우시 고속도로 노면 유출 오염부하 발생 특성 분석)

  • Kang, Hee-Man;Lee, Doo-Jin;Bae, Woo-Keun;Kang, Hye-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.47-54
    • /
    • 2012
  • This study analyzed influence factors and the correlation among pollutants which affect occurrence of leaked pollution based on the long-term runoff flow and water quality investigation results to understand the characteristics of highway rainfall runoff pollution load. According to the result of correlation analysis on TSS (Total Suspended Solid) concentration, anteceded dry days, rainfall intensity, traffic volume and etc. as major influence factors of highway rainfall runoff pollution loads, the correlations were weak or scarce in most items. These results might be attributed that runoff pollutant concentration changes vary severely on changes of rainfall intensity and rainfall duration within rainfall and it is affected by disturbances of vehicles and street cleaning and etc. as characteristics of the highway. While Cu, Fe and Zn which are discharged with high concentrations out of heavy metals showed high correlation with particulate matter, organic matter(COD), nutrient(TN, TP), Ni and Pb showed relatively low correlation in a correlation evaluation by pollutant. Significant correlation with traffic volumes was not shown and TSS concentration even decreased in accordance with increase of the traffic volume. In the comparison with precedent studies, it was considered necessary additional analysis of the effects of rainfall section analysis, road type, disturbances of surface contaminants by vehicles, rainfall and climate conditions, surrounding terrains etc.

Study on Slope Prevention Effect of Eco-environmental Riprap Structure (친환경 호안구조물의 사면보호 효과에 관한 연구)

  • Kim, Khi-Woong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.4
    • /
    • pp.47-51
    • /
    • 2009
  • The slope failure in the country is caused by mainly rainfall and its type is reported shallow slope failures in general. To investigate the cause of slope failure, the unsaturated soil slope behavior in accordance with rainfall amount studies actively, but there are little studies related the slope erosion and scour by rainfall. The slope erosion and scour by rainfall cause environmental pollution and slope instability, however there are few methods to effectively control them. This research analyzed experimentally how infinite gradients are infiltrated according to the changes of amount of rainfall and the slope of gradients by manufacturing the model of gradient in order to investigate how rainfall infiltrates regarding homogeneous gradients and slope protection method. For this, this experiment measured and analyzed discharge, storage rate occurring in gradients by going on changing amount of rainfall, slope of gradients.

  • PDF

Application of Percentile Rainfall Event for Analysis of Infiltration Facilities used by Prior Consultation for LID (Low Impact Development)

  • Kwon, Kyung-Ho;Song, Hye-Jin
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.5-12
    • /
    • 2015
  • Purpose: Retention and infiltration of small and frequently-occurring rainfall by LID facilities account for a large proportion of the annual precipitation volume. Based on 4 standard facilities such as Porous Pavement, Infiltration Trench, Cylindrical Infiltration Well, Rectangular Infiltration Well by Seoul Metropolitan Handbook of the Prior Consultation for LID. The total retention volume of each facility was calculated according to the type and size. The Purpose of this study is to find out the quantitative relationship between Percentile Rainfall Event and Design Volume of Infiltration Facilities. Methode: For the estimation of Percentile Rainfall Event, Daily Precipitation of Seoul from 2005 to 2014 was sorted ascending and the distribution of percentile was estimated by PERCENTILE spreadsheet function. The managed Rainfall Depth and Percentile of each facility was calculated at the several sizes. In response to the rainwater charge volume of 5.5mm/hr by the Category "Private large site", the 3 types of facilities were planned for example. The calculated Rainfall Depth and Percentile were 54.4mm and 90% by the use of developed Calculation-Module based on the Spreadsheet program. Result: With this Module the existing Designed Infiltration volume which was introduced from Japan was simply converted to the Percentile-Rainfall-Event used in USA.

Particle Scavenging Properties of Rain Clarified by a Complementary Study with Bulk and Semi-bulk Samples

  • Ma, Chang-Jin;Kang, Gong-Unn
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.177-186
    • /
    • 2018
  • It is a well-known fact that precipitation plays an important role in capturing ambient particles, however, the details of particle scavenging properties have not been fully proved. To clarify the particle scavenging properties, a complementary study was carried out with the bulk and semi-bulk rain samples collected in an urban city of Japan. pH showed a continued downturn for a little bit at the beginning rainfall and then a turn-up in the following rainfall. The recorded pH values of rainwater (ranged from 3.5-4.6) demonstrated that the strong acid rain was observed during our field measurements. Compared to the subsequent rainfall, electrical conductivity in the beginning rainfall had about 1.3 times higher level. Sulfur showed an overwhelmingly high concentration compared to other elements in both ambient total suspended particles (TSP) and rain samples. On the contrary to ambient TSP, every element including Ca and Zn in rain showed a continued rise in concentration accompanied by increasing of rainfall amount. During the first period of the rainfall there was no meaningful change in elemental carbon concentration, however, it was largely increased (up to $0.2mg\;L^{-1}$) in the sequential rainfall (4.0-4.5 mm rainfall amount). The theoretically calculated number concentration of particles scavenged by raindrops showed a strong decrease of with the increasing droplet diameter regardless of particle type.

Estimation of Design Rainfall Considering the Change of the Number of Years for Observed Data (관측년수변화를 고려한 설계강우량 산정)

  • Ryoo, Kyong-Sik;Lee, Soon-Hyuk;Hwang, Man-Ha;Lee, Sang-Jin
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.284-287
    • /
    • 2005
  • The objective of this study is to check into variation trends of design rainfall according to change of the number of years for observed data. To make comparative study of the relation between design rainfall and recorded year, this study was used maximum rainfall for 24-hr consecutive duration at Gangneung, Seoul, Incheon, Chupungnyeong, Pohang, Daegu, Jeonju, Ulsan, Gwangju, Busan, Mokpo and Yeosu rainfall stations. The tests for Independence, Homogeneity and detection of outliers were used Wald-Wolfowitz's test, Mann-Whitney's test and Grubbs and Beck test respectively. To select appopriate distribution, the distribution of genaralized pareto(GPA), generalized extreme value(GEV), generalized logistic(GLO), lognormal and pearson type 3 distribution is judged by L-moment ratio diagram and Kolmogorov-Smirnov (K-S) test. Design rainfall was estimated by at-site frequency analysis using L-moments and Generalized extreme value(GEV) distribution according to change of the number of years for observed data. Through the comparative analysis for design rainfall induced by L-moments and GEV distribution, relationship between design rainfall and recorded year is provided.

  • PDF

Appropriateness analysis of design rainfall factors using the rainfall data of an inundated flood events (침수 홍수사상의 강우자료를 활용한 설계강우 요소의 적정성 분석)

  • Yu, Byeong-Wook;Kim, Seon-Ho;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.4
    • /
    • pp.237-247
    • /
    • 2020
  • The purpose of this study is to analyze whether design rainfall and hyetograph, which are the main elements of design rainfall, can properly reflect the those of observed rainfalls through inundated rainfall events. The target areas were selected at seven large cities with high damages regarding to the flooding. Comparative analysis between probability and observed rainfall shows that 57% of the cases, in which rainfall amount through the IDF curve is estimated lower than the observed rainfall, do not properly reflect the observed rainfalls. In particular, this trend is exacerbated by the cases in low return period and the rain type of typhoon or frontal rain. The comparative results of rainfall intensity formula showed that the Talbot and Japanese formula were stable in the short- and long-term return periods, respectively. The comparison of hyetograph results also showed that the Mononobe method properly reflects the maximum rainfall intensity and the Huff method properly reflects the shape of rainfall pattern.

Peak Discharge Change by Dirrerent Design Rainfall on Small Watershed

  • Jun, Byong-Ho;Jang, Suk-Hwan
    • Korean Journal of Hydrosciences
    • /
    • v.3
    • /
    • pp.97-104
    • /
    • 1992
  • To design the minor structures in the small watersheds, it is required to calculate the peak discharge. For these calculations the simple peak flow prediction equations, the unit hydrograph method. the syntheic unit hydrograph methods or the runoff simulation models are adopted. To use these methods it is generally requried to know the amount and the distributions of the design rainfall; which are the uniform distribution, the trangular distribution, the trapezoidal distribution, or the Huff type distribution. In this study, the peak discharges are calculated by the different rainfall distributions and the results are compared.

  • PDF