• Title/Summary/Keyword: Rain storage tank

Search Result 10, Processing Time 0.027 seconds

Study on Utilizing Resources in Environment-friendly City - Operation method of rain storage tank for using rainwater as multipurpose - (친환경 도시에서의 자원활용에 관한 연구 -빗물의 다목적 활용을 위한 빗물저장조의 운전방법 -)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.12 no.3
    • /
    • pp.359-366
    • /
    • 2003
  • Ecological society and energy conservative systems has become a subject of world wide attention. To examine the technologies of such systems as resource recycling society, this study is proposed for using rainwater as energy source and water resources in urban area. Useful informations for planning of utilizing rainfall as energy source, water resources, emergency water and controlling flood are discussed with model systems in urban area. It is calculated that the rate of utilizing rainwater, amounts of utilizing rainwater, substitution rate of supply water, amounts of overflow rainwater according to rain storage tank volume. By applying the past weather data, The optimum volume of rain water storage was calculated as 200m$^3$ which mean no benefits according to the increase of storage tank volumes. For optimum planing and control method at the model system, several running method of rainwater storage tank was calculated. The optimum operating method was the using weather data as 3hours weather forecast.

A Discussion on Determination of Suitable Size of Rain Tank Connected to Building Roof in Suwon District (건축물 지붕과 연결된 빗물저류조의 적정 규모 결정에 관한 고찰: 수원지역을 중심으로)

  • Noh, Huiseong;Ahn, Taejin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.161-169
    • /
    • 2022
  • In this study to estimate suitable size of rain tank in Suwon district, monthly rainfall, daily rainfall duration curve and daily rainy days have been analyzed. Annual rainwater consumption and daily average amount of storage with respect to size of rain tank have been calculated by applying continuity equations that take account of daily rainfall, daily consumptive use, storage of rain tank, It has been shown that above 50 mm of rainfall in the ordinance related to reclamation water may be inappropriate regulation if annual amount of rainfall captured, efficiency of utilized rainwater, number of days for utilized rain tank, daily average amount of storage and daily consumptive use have been considered. Thus, it has been shown that suitable size of rain tank should be determined considering reasonable daily consumptive use with respect to district, constructed cost of rain tank and benefit of rain tank constructed.

Nature-adapted Rainwater Management Facility Cases in Korean Apartment Complexes (국내 공동주택단지 자연 순응형 빗물관리시설 사례 분석)

  • Hyun, Kyoung Hak;Chang, Sun Young;Ahn, Sung Sik
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.2
    • /
    • pp.111-119
    • /
    • 2006
  • In Korea, an environment-friendly concept of "rain re-cycling" was initially introduced in apartment complex planning and designs in the late 1990s. Although its application cases are extremely few, with the growing importance of rainwater utilization, introduction of rainwater management facilities in urban areas began to drawn keen attention. In urban areas also, plans to introduce rainwater management facilities in apartment complexes as infrastructure improving living environment, such as sewage treatment facilities are very urgently required. In order to introduce rainwater management facilities as infrastructure in an apartment complex, apartment complex cases that had introduced the facilities were reviewed first. In this study, a few applied rainwater management facilities in an apartment complex were surveyed(Infiltration barrel, Rubble porosity storage tank, Underground storage tank). As a result, problems in introducing rainwater management facilities in apartment complexes in Korea were identified.

Volume of Water Storage and Evapotranspiration by Inserted Materials at a Reservoir of Porous Grass Block (저수형 잔디블록 저수조 내 충진재료에 따른 저수량 및 초종별 증발산량)

  • Han, Seung-Ho;Choi, Joon-Soo;Yang, Geun-Mo;Yang, Byoung-E;Kang, Jin-Hyoung;Kim, Won-Tae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.5 s.118
    • /
    • pp.76-83
    • /
    • 2006
  • The purpose of this study was to investigate the performance of porous grass block. For the investigation, Festuca arundinacea and Zoysia japonica 'Zenith' were planted, and the volume of evapotranspiration and remains were examined based on different materials in the water tank in the experiment of Festuca arundinacea, the volume of water storage of treatment with perlite ($10.84{\iota}/m^2$) was higher than that with drainage ($7l/m^2$). The difference between the two was $3.84/m^2$. The drainage treatment without water storage capacity showed the higher degree of dryness in turf grass. The volume of evapo-transpiration of treatment with perlite was the highest (21.57mm/week). The volume of evapotranspiration of treatment with sand was 19.57mm/week, and with treatment with drainage was 18.24mm/week. Based on the measured volume of daily evapotranspiration of $2.60{\sim}3.08mm\;d^{-1}$, it was determined that the unit with water storage capacity would store water of one to two days usage compared to unite without such storage capacity. In the experiment of Zoysia japonica 'Zenith', the volume of water storage of treatment with perlite was $10.77l/m^2$ which was similar to the former experiment. The volume of evapotranspiration of treatment with perlite and sand were 21.64mm/week and 20.64mm/week, respectively. In case of airtight water tank, the volume was measured as 22.06mm/week. Each treatment has no notable difference in the volume of evapotranspiration. In conclusion, from the investigation in this study, porous grass block with water tank was found to be effective in plant growth under low irrigation. As the ecological area ratio and vegetated porous pavement have became more emphasized, additional study of rain infiltration and reservoir effect are needed in the future.

Heavy Rain and Flood Prevention in Urban (뉴스초점: 집중호우와 도시지역 홍수방어)

  • Jeong, Sun-Gil
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.6
    • /
    • pp.31-34
    • /
    • 2010
  • Recently, due to localized heavy rain and flash floods in urban areas is becoming more frequent flood damage. To prevent flood inundation damage, to formulate the diverse directions in connection with the drainage system of buildings, roads, sewerage, pump stations, detention (retention) pond, and streams is very important. In addition, it is important for the uniform design criteria, the consistent of hydrologic and hydraulic analysis method, and a flood disaster mitigation systems connected with structural and nonstructural measures. To accomplish this, the method such as installation of storage facilities, infiltration facilities, and underground water tank, the optimal size of the design gutter and grate of the road, ensure the capacity of pumping stations, and the installation of a flood control channel into the deep underground requires comprehensive measures dimension in urban areas.

  • PDF

A Study on the Properties of Hwangto Permeable Block Using Ferro Nickel Slag (페로니켈슬래그를 혼입한 황토투수블럭 물성에 관한 연구)

  • Kim, Soon-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.607-618
    • /
    • 2022
  • This study involves the development of a Hwangto permeable block for rainwater storage tanks. The permeable products that form continuous voids between Hwangto binders and aggregates are fine milled slag powder, which is an industrial by-product generated during the production of Hwangto and iron, and ferro nickel slag. The properties of Hwangto permeable blocks were studied using recycled resource aggregates. The target quality is based on KSF 2394. The Hwangto permeable block for a rainwater storage tank is made of water-permeable material, and the permeability of the Hwangto permeable block itself is 0.1mm/sec or higher, with a physical performance of over 5.0MPa in flexural strength and over 20.0MPa in compressive strength. The physical properties of Hwangto permeable block for rainwater storage tanks were researched and developed. In order to prevent flooding due to heavy rain in summer and the urban heat island phenomenon due to depletion of ground water, continuous pores are formed in the block to secure a permeability function to prevent rainwater from accumulating in the pavement of the floor, and to prevent slippage for comfortable and safe storage.

The effect of Temperature Reduction of Green Roof using Rainwater Storage Tank (빗물 저류 시스템을 활용한 옥상 녹화의 온도 저감 효과)

  • Yun, Seok-Hwan;Kim, Eun-Sub;Piao, Zheng-Gang;Jeon, Yoon-Ho;Kang, Hye-Won;Kim, Sang-Hyuck;Kim, Ji-Yeon;Kang, Han-Min;Ham, Eun-Kyung;Lee, Dong-Kun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.6
    • /
    • pp.109-119
    • /
    • 2021
  • Thermal environment of city is getting worse due to severe urban heat island caused by climate change and urbanization. Green roof improves the urban thermal environment and save the cooling energy in buildings. This study presented a green roof combined with a storage system that stores rain-water and supplies water through a wick and evaluated the temperature reduction effect as surface temperature and amount of evapotranspiration. For about a week, the surface temperature using a infrared thermal imager and the evapotranspiration by recording change of module weight were measured at intervals of 30 minutes from sunrise to sunset. The results show that the mean surface temperature of the green roof was 15.4 degrees lower than that of the non-green roof from 12:00 P.M. to 14:00 P.M. There was no significant difference between mean surface temperature of green roof with and without storage system immediately after rain, but more than a week after rain, there was a difference with average of 2.49 degrees and maximum of 4.72 degrees. The difference in daily amount of evapotranspiration was measured to be 1.66 times on average. As drought stress increased over time, the difference in daily amount of evapotranspiration and surface temperature between with/without storage system increased simultaneously. The results of the study show a more excellent cooling effect of green roof combined with the rainwater storage system.

A Study on Design of Vacuum Silo for Batch Treatment System for Dredged Soil (준설토 일괄처리시스템을 위한 진공사이로 설계에 관한 연구)

  • Kim, Yong-Seok;Yang, Hae-Rim;Kim, Hac-Sun;Jeoung, Chan-Se;Yang, Soon-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.571-577
    • /
    • 2012
  • In this study, a small movable batch treatment system for dredging soil deposited in a rain water tube is proposed; further, a vacuum silo sorting separation device with a vacuum silo, first-stage sorting separator, and conveyor is designed. The vacuum silo sorting separation device also consists of a storage tank, transferring screw, vacuum gate, screen bar, screen bar cleaner, and vacuum discharging device. In view of the fact that the flow of drawn air in the storage tank is a major factor influencing the sorting separation performance, the optimum shape of the tank is determined by CFD flow analysis. In addition, by using CAE structure analysis, the safety of a storage tank made of boards is examined. The specifications of the vacuum silo sorting separation device are determined by conducting mechanical and dynamic simulations of the driving mechanism of the vacuum silo sorting separation device through 3D-CAD modeling. Following this study, we will design a drum-screen-type second sorter, a decanter-type dehydration device, and waste water tank and pump as a secondary device. Further, on the basis of this design, we will construct a prototype model and carry out a field test.

A Study on the Effect of. Oil Leakage for Soil Contamination, Plants and Groundwater (오일의 누출이 토양오염, 식생 및 지하수에 주는 영향에 관한 연구)

  • 진성기;도덕현;최규홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.1
    • /
    • pp.141-152
    • /
    • 1994
  • Our experiment investigated the degree of soil contaimination caused by oil leakage. Each soil sample was taken by boring 5, 8m below the test areas, located 5 to 30m from storage tanks at oil stations. According to the results from a series of laboratory tests(both soxhiet extract test and gas chromatograph test), Traces of a light oil were found in all samples except in Dj8, rocky soil and gasoline and petroleum were not detected. We concluded that soil contamination was caused by the corrosion of storage tanks or alternatively by oil overflow caused during the flooding of underground water seeping into the tank during heavy rain fall or the spillage caused by carelessness during lubrication. Old stations without a concrete box enclosing their metal tanks run a greater risk of oil leakage. To research the effect of oil leakage on plant growth and underground water, We examined the results of research conducted overseas. According to these results, when oil leakage occurs, plant growth is repressed and agricultural crops experience low productivity levels. Also, the contamination of underground water can be serious when oil spreads to the aquifer layer. As a result of these problems, to prevent oil leakage and minimize its contaminating effects at oil stations, it is necessary to improve facilities of storage tanks and have the monitoring system of oil leakage.

  • PDF

Analysis for flood reduction by rain storage tank (빗물저류조 설치에 의한 침수저감 분석)

  • Seung Wook Lee;Seung Jin Maeng;Da Ye Kim;In Seong Park
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.356-356
    • /
    • 2023
  • 충청북도 청주시 상당구 월오동 251-7번지와 251-15번지 2곳에 각각 50m3 규모의 빗물저류조를 대상으로 2017년 7월 16일 호우사상을 적용하여 설치 전·후의 침수저감 효과를 분석하였다. 침수분석을 위해 지형자료는 국토정보플랫폼에 있는 1:25,000 자료를 활용하였으며, 모의 전 대상지역의 관망구축에 따른 지형자료를 구축하였고 관망은 노드 40개와 링크 39개로 구성하였다. SWMM 모형을 구동하여 유역내 유출량을 분석하기 위해 유역과 관련한 입력자료와 이외 유역간의 연결부인 관거 하도 입력자료 구축 및 하도와 하도를 연결하는 모델상의 Junction인 실제 맨홀과 관련한 입력자료를 구축하였다. 관거 입력자료로는 관거의 제원, 길이, 깊이 등의 자료를 수집하여 사용하였다. 빗물저류조 설치전·후의 침수저감효과를 분석하기 위해 빗물저류조 설치전의 침수양상을 모의 하였으며 각각 강우발생 후 30분, 50분, 70분, 90분, 110분, 130분 및 150분으로 구분하여 분석하였다. 강우발생 후 150분의 모의분석 결과, 침수심은 0.2<깊이<0.4의 면적이 600m2로 가장 넓은 침수분포를 나타내었으며, 총 침수면적은 2,225m2로 모의되었다. 이는 강우발생 후130분 보다 125m2 더 침수되었으며, 0.8<깊이<1.0의 면적은 150m2로 모의되었다. 전체적인 침수심도 커진 것으로 분석되었다. 빗물저류조 설치 후의 침수양상을 모의하였으며 각각 강우발생 후 30분, 50분, 70분, 90분, 110분, 130분 및 150분으로 분석하였다. 강우발생 후 150분의 모의분석 결과, 침수심은 0.2<깊이<0.4의 면적이 250m2로 가장 많은 침수분포가 나타났으며, 총 침수면적은 550m2으로 모의 되었다. 이는 강우발생 후 110분과 침수면적은 동일하게 모의 되었으며, 침수심 0.2<깊이<0.4의 면적은 250m2로 모의 되었다. 따라서 해당 지역에 50m3 규모의 빗물저류조 2개를설치 할 경우 침수피해가 저감되는 것으로 분석되었다. 이러한 분석 결과를 바탕으로 향후 도시내 상습침수구역에 빗물저류조를 설치하여 기후변화에 따른 극한 강우에 대비할 수 있도록 해야 할 것이다.

  • PDF