• Title/Summary/Keyword: Radionuclide imaging

Search Result 92, Processing Time 0.025 seconds

Comparison of planar scintigraphy and bone SPECT with clinical findings and other imaging modalities in temporomandibular disorder patients (측두하악관절장애 환자에서의 평면 골 스캔 및 Bone SPECT 소견과 임상적 및 영상학적 소견과의 비교)

  • Jeong Hee-Jeong;Cho Bong-Hae;Jung Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.34 no.2
    • /
    • pp.91-97
    • /
    • 2004
  • Purpose : This study was performed to evaluate the diagnostic value of both planar and SPECT imagings by comparing the results with the clinical and other imaging modalities findings. Materials and Methods: A total of 578 joints with TMJ complaints were examined using planar scintigraphy and SPECT. The planar scintigraphy and SPECT findings were analyzed and compared to the clinical findings of pain, clicking, crepitus and limitation of mouth opening. Moreover we compared the accuracy of the planar scintigraphy and SPECT methods with the one of the panoramic, transcranial, tomographic and MR imaging methods. Results: The planar scintigraphy and SPECT methods showed a high sensitivity of 0.76-0.84 and low specificity of 0.25-0.45 toward the clinical findings: pain, clicking, crepitus and mouth opening restriction. Simple radionuclide uptake ratio was high in each group of patients with pain, crepitus, limitation of mouth opening (p < 0.05) complaints, in each group with positive bone changes on panoramic, transcranial or tomographic images, and in disc displaced group. Conclusion: Although both planar and SPECT imagings have limited specificity, these techniques are sensitive for detection of internal derangement of the TMJ.

  • PDF

Tc-99m hydroxymethylene diphosphonate scintigraphy, computed tomography, and magnetic resonance imaging of osteonecrosis in the mandible: Osteoradionecrosis versus medication-related osteonecrosis of the jaw

  • Ogura, Ichiro;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki;Kameta, Ayako;Hayama, Kazuhide
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.53-58
    • /
    • 2019
  • Purpose: To present characteristic findings of Tc-99m hydroxymethylene diphosphonate (HMDP) scintigraphy, computed tomography (CT), and magnetic resonance (MR) imaging for osteonecrosis in the mandible, especially osteoradionecrosis(ORN) and medication-related osteonecrosis of the jaw(MRONJ). Materials and Methods: Thirteen patients with MRONJ and 7 patients with ORN in the mandible underwent Tc-99m HMDP scintigraphy, CT, and MR imaging (T1-weighted images[T1WI], T2-weighted images[T2WI], short inversion time inversion recovery images[STIR]), diffusion-weighted images[DWI], and apparent diffusion coefficient [ADC] mapping). The associations of scintigraphy, CT, and MR imaging findings with MRONJ and ORN were analyzed using the chi-square test with the Pearson exact test. Results: Thirteen patients with MRONJ and 7 patients with ORN in the mandible showed low signal intensity on T1WI and ADC mapping, high signal intensity on STIR and DWI, and increased uptake on scintigraphy. Periosteal bone proliferation on CT was observed in 69.2% of patients with MRONJ(9 of 13) versus 14.3% of patients with ORN(1 of 7)(P=0.019). Conclusion: This study presented characteristic imaging findings of MRONJ and ORN on scintigraphy, CT, and MR imaging. Our results suggest that CT can be effective for detecting MRONJ and ORN.

Combined Intrathoracic and Intraperitoneal Splenosis after Splenic Injury: Case Report and Review of the Literature

  • Moon, Chansoo;Choi, Yun-Jung;Kim, Eun Young;Lee, In Sun;Kim, Sae Byol;Jung, Sung Mo;Kim, Se Kyu;Chang, Joon;Jung, Ji Ye
    • Tuberculosis and Respiratory Diseases
    • /
    • v.74 no.3
    • /
    • pp.134-139
    • /
    • 2013
  • Splenosis is defined as an autotransplantation of the splenic tissue after splenic rupture or splenectomy, and occurs most frequently in the peritoneal cavity. Splenosis is usually asymptomatic and is found incidentally. We report a case of combined intrathoracic and intraperitoneal splenosis in a 54-year-old male who worked as a miner for 10 years in his twenties, and was a current smoker. He was referred to our hospital for further evaluation of an incidental left diaphragmatic mass. Positron emission tomography-computed tomography and bronchoscopy were performed to evaluate the possibility of malignancy. There was no evidence of malignancy, but the spleen was not visualized. Reviewing his medical history revealed previous splenectomy, following a dynamite explosion injury. Therefore, splenosis was suspected and technetium-99m-labeled heat-damaged red blood cell scan confirmed the diagnosis. Radionuclide imaging is a useful diagnostic tool for splenosis, which could avoid unnecessary invasive procedures.

Comparison of functional Images obtained by radionuclide angiocardiography and gated blood pool scan (방사성핵종 심혈관조영술의 기능적영상화에 대한 고찰)

  • Bom, Hee-Seung;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.186-191
    • /
    • 1991
  • Radionuclide cardiac studies lend themselves exceptionally well to functional imaging. This is especially true for gated blood pool scan (GBP). Making functional images is also possible in radionuclide angiocardiography (RNAC). In this study we tried to validate the functional images obtained from RNAC by comparing it with GBP. Twenty three patients (16 patients with coronary artery diseases, 5 with hypertensive heart diseases, and 2 with nonspecific chest pains) underwent simultaneous RNAC and GBP at the same position (LAO $45^{\circ}$). From both studies, global ejection fraction, regional ejection fraction, phase image, amplitude image, stroke image, paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox images of RNAC are very similar to those of GBP. However, amplitude and stroke images are different. Regional ejection fractions of the left ventricular base, maximum ejection and maximum filling rates obtained from RNAC are significantly different from those of GBP. In conclusion, albeit all of functional images of RNAC is not same as GBP, regional walt motions and global left ventricular function are expected to be successfully analyzed by phase and paradox image and ejection fraction.

  • PDF

A Feasibility Study of a SiPM Based Intraoperative Beta Imaging/Gamma Probe using the Depth of Interaction Measurement (실리콘 광증폭기와 반응깊이 측정방법을 이용한 수술용 베타 영상/감마 프로브 가능성 연구)

  • Kwak, In-Suk;Kang, Han Gyu;Son, Jeong-Whan;Lee, Jae Sung;Hong, Seong Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • Radiopharmaceutical agents for positron emission tomography (PET), such as $^{18}F$-FDG and $^{68}Ga$, have been used not only for whole-body PET imaging but also for intraoperative radionuclide-guided surgery due to their quantitative and sensitive imaging characteristics. Current intraoperative probes detect gamma or beta particles, but not both of them. Gamma probes have low sensitivities since a collimator has to be used to reduce backgrounds. Positron probes have a high tumor-to-background ratio, but they have a 1-2 mm depth limitation from the body surface. Most of current intraoperative probes produce only audible sounds proportional to count rates without providing tumor images. This research aims to detect both positrons and annihilation photons from $^{18}F$ using plastic scintillators and a GAGG scintillation crystal attached to silicon photomultiplier (SiPM). The depth-of-interaction (DOI) along the plastic scintillator can be used to obtain the 2-D images of tumors near the body surface. The front and rear part of the intraoperative probe consists of $4{\times}1$ plastic scintillators ($2.9{\times}2.0{\times}12.0mm^3$) for positron detection and a Ce:GAGG scintillation crystal ($12.0{\times}12.0{\times}9.0mm^3$) for annihilation photon detection, respectively. The DOI resolution of $4.4{\pm}1.6mm$ along the plastic scintillator was obtained by using the 3M enhanced specular reflector (ESR) with rectangular holes between the plastic scintillators, which showed the feasibility of a 2-D image pixel size of $2.9{\times}4.4mm^2$ (X-direction ${\times}$ Y-direction).

Three-Phase Bone Scintigraphic Diagnosis of Acute Transient Synovitis (3상 골신티그램을 이용한 급성 일과성 활막염의 진단)

  • Chung, Soo-Kyo;Lee, Myung-Hee;Kim, Choon-Yul;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.1
    • /
    • pp.73-75
    • /
    • 1985
  • Acute transient synovitis of the hip presents clinically pain and limping. But in the majority of the cases, definite positive findings are not manifest in roentgenogram in its early phase. However radionuclide bone imaging combines with the assessment of vascularization and bone tracer uptake is of great value in solving this diagnostic problem. The materials for this study consisted of 29 children with acute transient synovitis of the hip, characterized by symptoms and physical signs of an arthritis, negative X-ray findings and disappearance of all symptoms and signs within a short period of time. They were twenty males and 9 females and age ranged from 1 to 12 years. We took pelvic reontgenogram in AP and frog-leg views. After intravenous bolus injection of 10 to 15 mCi of $^{99m}Tc-methylene$ diphosphonate, 24 sequential image of the pelvis was taken at 2-second interval for blood flow study. The scintigrams were made using a gamma camera with high resolution parallel hole collimator. Blood pool imaging was obtained at 2 minutes after tracer administration. After 3 hours, static images were taken and then closeup image of the hip using pin-hole collimator was followed. The results were as follows: 1) Bone scintigram was much more sensitive than conventional roentgenogram in diagnosis of acute transient synovitis of the hip. 2) Three-phase imagings showed increased vascular activities in blood pool scintigrams in 96%. 3) Pin-hole imaging showed increased tracer uptake in the regional bones of the hip, par ticularly in the medial aspect of femoral head and acetabulum. 4) We confirmed that three-phase imaging reinforced with pin-hole technique were very useful in diagnose of acute transient synovitis of the hip.

  • PDF

Radiologic Diagnosis of Gastrointestinal Bleeding (위장관 출혈의 영상의학적 진단법)

  • Se Hyung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.520-535
    • /
    • 2023
  • Gastrointestinal (GI) bleeding is not a single disease but a symptom and clinical manifestation of a broad spectrum of conditions in the GI tract. According to its clinical presentation, GI bleeding can be classified into overt, occult, and obscure types. Additionally, it can be divided into upper and lower GI bleeding based on the Treitz ligament. Variable disease entities, including vascular lesions, polyps, neoplasms, inflammation such as Crohn's disease, and heterotopic pancreatic or gastric tissue, can cause GI bleeding. CT and conventional angiographies and nuclear scintigraphy are all radiologic imaging modalities that can be used to evaluate overt bleeding. For the work-up of occult GI bleeding, CT enterography (CTE) can be the first imaging modality. For CTE, an adequate bowel distention is critical for obtaining acceptable diagnostic performance as well as minimizing false positives and negatives. Meckel's scintigraphy can be complementarily useful in cases where the diagnosis of CTE is suboptimal. For the evaluation of obscured GI bleeding, various imaging modalities can be used based on clinical status and providers' preferences.

Evaluation of Peritoneo-venous Shunt Patency with $^{99m}Tc-phytate$ ($^{99m}Tc-phytate$를 이용한 LeVeen 복막대정맥문합폐쇄의 진단)

  • Hur, Dal-Young;Chung, June-Key;Lee, Jong-Suk;Lee, Chang-Su
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.2
    • /
    • pp.93-95
    • /
    • 1985
  • A simple imaging procedure has been devised for patients with peritoneo-venous shunts when ascites reaccumulates and a decision must be made on whether or not to revise the shunt. We recently experienced a patient with reaccumulated ascites in whom obstruction of peritoneo-venous shunt was suspected. 5 mCi of $^{99m}Tc-phytate$ was injected into the peritoneal cavity and imaging of the abdomen was performed $1\sim30$ minutes later. With a proper funtioning shunt, radioactivity in the liver and spleen were easily identifiable in this case. If the shunt is obstructed, tracer activity will remain in the peritoneal cavity and thus can not be identifiable in the liver or spleen. Conclusively, radionuclide methods might be very useful for evaluation of peritoneo-venous shunt patency.

  • PDF

A Study on the Thyroid Scan Images by Different Radionuclides ($^{99m}Tc$ pertechnetate and $^{131}I$) and Multiple Views (사용핵종(使用核種) 및 주사방향(走査方向)에 따른 갑상선주사상(甲狀腺走査像)의 차이(差異)에 관한 연구(硏究))

  • Whang, Il-Yong;Chung, Soon-Il;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 1986
  • Thyroid scans using $Na^{131}I\;and\;^{99m}TcO_4^-$ in two (anterior and anterior oblique) projections were done simultaneously in 50 patients with single palpable nodule and in euthyroid state(nodular nontoxic goiter) and 20 normal subjects to evaluate the imaging ability of each radionuclide and the necessity of oblique view. In detection of a nodule as a cold or cool area, $^{99m}TcO_4^-$ was slightly superior to $^{131}I$(82 % to 78% with anterior view alone, 92% to 84% when oblique view is added in detectability), with addition of an oblique view, 5 more cold or cool area in $^{99m}Tc$ scan and 3 more $^{131}I$ scan were detected. In normal subjects $^{99m}TcO_4^-$ scan was significantly superior to $^{131}I$ scan(90% to 70%) in getting normal pattern of tracer uptake in the glands. For routine imaging study of the thyroid, $^{99m}Tc$ pertechnetate scan with multiple projection is considered to be a preferable method.

  • PDF

Radioimmunotherapy (I): Development of Radioimmunoconjugates (방사면역치료(I): 방사면역접합체 개발)

  • Choi, Tae-Hyun;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.2
    • /
    • pp.66-73
    • /
    • 2006
  • Monoclonal antibodies are designed to bind specifically to certain antigen, give therapeutic effect to the target and to be produced in large scale with homogeneity. The monoclonal antibodies conjugated with radionuclide can deliver therapeutic irradiation to the target, and showed successful results in certain malignancies, which is known as radioimmunotherapy. The target-to-background ratio depends on the antigen expression in the target and normal tissues, which is related to the therapeutic efficacy and toxicity in radioimmunotherapy. For the solid tumor beta-ray energy should be high, but lower beta energy is better for the hematological malignancies. I-l31 is widely used in thyroid cancer with low cost and high availability. Labeling monoclonal antibody with I-131 is relatively simple and reproducible. Some preclinical data for the I-131 labeled monoclonal antibodies including acute toxicity and efficacy are available from already published literatures in KIRAMS, physician sponsored clinical trial protocols using Rituximab, KFDA approved anti-CD20 chimeric monoclonal antibody and I-131 were approved by KFDA and currently are ongoing.