• Title/Summary/Keyword: Radiometric quality

Search Result 44, Processing Time 0.025 seconds

Ocean Scanning Multi-spectral Imager (OSMI) Pre-Launch Radiometric Performance Analysis

  • Cho, Young-Min
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.390-395
    • /
    • 1999
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the Korean Multi-purpose SATellite (KOMPSAT) to perform worldwide ocean color monitoring for the study of biological oceanography KOMPSAT will be launched in the middle of November this year. The radiometric performance of OSMI is analyzed for various gain settings in the viewpoint of the instrument developer for OSMI calibration and application based on its ground performance measurement data for 8 primary spectral bands of OSMI. The radiometric response linearity and dynamic range are analyzed for the image radiometric calibration and the estimation of OSMI image quality for the ocean remote sensing area. The dynamic range is compared with the nominal input radiance for the ocean and the land. The noise equivalent radiance (NER) corresponding to the instrument radiometric noise is compared with the radiometric resolution of signal digitization (1-count equivalent radiance). The best gain setting of OSMI for ocean monitoring is recommended. This analysis is considered to be useful for the OSMI mission and operation planning, the OSMI image data calibration, and users' understanding about OSMI image quality.

  • PDF

RADIOMETRIC CHARACTERISTICS OF KOMPSAT-2 HIGH RESOLUTION IMAGES

  • Chi, Jun-Hwa;Yoon, Jong-Suk;Lee, Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.390-393
    • /
    • 2007
  • KOMPSAT-2, the first Korean high resolution earth observing satellite, continuously acquires high resolution images since July 2006. The quality of satellite images should be geometrically and radiometrically ensured before distribution to users. This study focused on absolute radiometric calibration which is a prerequisite procedure to ensure the radiometric quality of optical satellite images. In this study, we performed reflectance-based vicarious calibration methods on several uniform targets collected through several field campaigns in 2007. The radiative transfer model, MODTRAN, was used to estimate the amount of energy received at the sensor. The energy reached at the sensor are affected by several factors such as reflectance of targets, atmospheric condition, geometry condition between Sun and the sensor, etc. This study proposes the absolute radiometric calibration coefficients of KOMPSAT-2 MSC images combining several types of collected data through field works and tried to compare dynamic range of sensor-detected energy with other commercial high resolution sensors.

  • PDF

Prelaunch Radiometric Performance Analysis of Ocean Scanning Multi-spectral Imager (OSMI)

  • Cho, Young-Min
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.2
    • /
    • pp.135-143
    • /
    • 2000
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the Korean Multi-Purpose SATellite (KOMPSAT) to perform global ocean color monitoring for the study of biological oceanography. HOMPSAT was launched 21 December 1999. The radiometric performance of OSMI is analyzed for various gain settings in the viewpoint of the instrument developer for OSMI calibration and application based on its ground performance data measured before launch. The radiometric response linearity and dynamic range are analyzed and the dynamic range is compared with the nominal input radiance for the ocean and the land. The noise equivalent radiance (NER) corresponding to the instrument radiometric noise is compared with the radiometric resolution of signal digitization (1-count equivalent radiance). The best gain setting of OSMI for ocean monitoring is recommended. This analysis is considered to be useful for the OSMI mission and operation planning, the OSMI image data calibration, and users' understanding about OSMI image quality.

Investigation on Image Quality of Smartphone Cameras as Compared with a DSLR Camera by Using Target Image Edges

  • Seo, Suyoung
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.1
    • /
    • pp.49-60
    • /
    • 2016
  • This paper presents a set of methods to evaluate the image quality of smartphone cameras as compared with that of a DSLR camera. In recent years, smartphone cameras have been used broadly for many purposes. As the performance of smartphone cameras has been enhanced considerably, they can be considered to be used for precise mapping instead of metric cameras. To evaluate the possibility, we tested the quality of one DSLR camera and 3 smartphone cameras. In the first step, we compare the amount of lens distortions inherent in each camera using camera calibration sheet images. Then, we acquired target sheet images, extracted reference lines from them and evaluated the geometric quality of smartphone cameras based on the amount of errors occurring in fitting a straight line to observed points. In addition, we present a method to evaluate the radiometric quality of the images taken by each camera based on planar fitting errors. Also, we propose a method to quantify the geometric quality of the selected camera using edge displacements observed in target sheet images. The experimental results show that the geometric and radiometric qualities of smartphone cameras are comparable to those of a DSLR camera except lens distortion parameters.

Verification of GEO-KOMPSAT-2A AMI Radiometric Calibration Parameters Using an Evaluation Tool (분석툴을 이용한 천리안2A 기상탑재체 복사 보정 파라미터 검증)

  • Jin, Kyoungwook;Park, Jin-Hyung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_1
    • /
    • pp.1323-1337
    • /
    • 2020
  • GEO-KOMPSAT-2A AMI (Advanced Meteorological Imager) radiometric calibration evaluation is an essential element not only for functional and performance verification of the payload but for the quality of the sensor data. AMI instrument consists of six reflective channels and ten thermal infrared ones. One of the key parameters representing radiometric properties of the sensor is a SNR (Signal-to-Noise Ratio) for the reflective channels and a NEdT (Noise Equivalent delta Temperature) for the IR ones respectively. Other important radiometric calibration parameters are a dynamic range and a gain value related with the responsivity of detectors. To verify major radiometric calibration performance of AMI, an offline radiometric evaluation tool was developed separately with a real-time AMI data processing system. Using the evaluation tool, validation activities were carried out during the GEO-KOMPSAT-2A In-Orbit Test period. The results from the evaluation tool were cross checked with those of the HARRIS, which is the AMI payload vendor. AMI radiometric evaluation activities were conducted through three phases for both sides (Side 1 and Side 2) of AMI payload. Results showed that performances of the key radiometric properties were outstanding with respect to the radiometric requirements of the payload. The effectiveness of the evaluation tool was verified as well.

Image Radiometric Quality Assessment of the Meteorological Payload on GEO-KOMPSAT-2A (정지궤도복합위성 기상탑재체 영상의 복사 성능 품질 측정)

  • Jin, Kyoung-Wook;Yang, Koon-Ho;Choi, Jae-Dong
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.30-39
    • /
    • 2013
  • In this study, calibration processes and methods of evaluating the radiometric quality of satellite images from the meteorological payload on the GEO-KOMPSAT-2A were described. MTF(Modulation Transfer Function), SNR(Signal-To-Noise Ratio), NEdT(Noise Equivalent Delta Temperature), and Dynamic Range, which are the major parameters for assessment of data radiometric quality of space-borne visible and infrared sensors, are focused. Key process of the quality check of the satellite data is the comparing the image radiometric performance parameters during the In-Oribit Test with those acquired from the ground tests. Validation plan of the image quality of the GEO-KOMPSAT-2A Meteorological Imager is addressed based on the analyses results of COMS MI data during the COMS In-Orbit Test period

Validation of the Radiometric Characteristics of Landsat 8 (LDCM) OLI Sensor using Band Aggregation Technique of EO-1 Hyperion Hyperspectral Imagery (EO-1 Hyperion 초분광 영상의 밴드 접합 기법을 이용한 Landsat 8 (LDCM) OLI 센서의 방사 특성 검증)

  • Chi, Junhwa
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.4
    • /
    • pp.399-406
    • /
    • 2013
  • The quality of satellite imagery should be improved and stabilized to satisfy numerous users. The radiometric characteristics of an optical sensor can be a measure of data quality. In this study, a band aggregation technique and spectral response function of hyperspectral images are used to simulate multispectral images. EO-1 Hyperion and Landsat-8 OLI images acquired with about 30 minutes difference in overpass time were exploited to evaluate radiometric coefficients of OLI. Radiance values of the OLI and the simulated OLI were compared over three subsets covered by different land types. As a result, the index of agreement shows over 0.99 for all VNIR bands although there are errors caused by space/time and sensors.

EVALUATION OF THE RADIOMETRIC AND SPECTRAL CHARACTERISTICS OF THE CAISS

  • Lee, Kwang-Jae;Yong, Sang-Soon;Kim, Yong-Seung
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.243-246
    • /
    • 2008
  • The Compact Airborne Imaging Spectrometer System (CAISS) was jointly designed and developed as the hyperspectral imaging system by Korea Aerospace Research Institute (KARI) and ELOP inc., Israel. The primary mission of the CAISS is to acquire and provide full contiguous spectral information with high quality spectral and high spatial resolution for advanced applications in the field of remote sensing. The CAISS consists of six physical units; the camera system, the gyro-stabilized mount, the jig, the GPS/INS, the power inverter and distributor, and the operating system. These subsystems shall be tested and verified in the laboratory before the flight. Especially the camera system of the CAISS shall be calibrated and validated with the calibration equipments such as the integrated sphere and spectral lamps. To improve data quality and availability, it is the most important to understand the mechanism of hyperspectral imaging system and the radiometric and spectral characteristics. This paper presents the major characteristics of camera system on the CAISS and summarizes the results of radiometric and spectral experiment during preliminary system verification.

  • PDF

Absolute Radiometric Calibration for KOMPSAT-3 AEISS and Cross Calibration Using Landsat-8 OLI

  • Ahn, Hoyong;Shin, Dongyoon;Lee, Sungu;Choi, Chuluong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.4
    • /
    • pp.291-302
    • /
    • 2017
  • Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remotely sensed data. This paper presents absolute radiometric calibration of the KOMPSAT-3 (KOrea Multi Purpose SATellite-3) and cross calibration using the Landsat-8 OLI (Operational Land Imager). Absolute radiometric calibration was performed using a reflectance-based method. Correlations between TOA (Top Of Atmosphere) radiances and the spectral band responses of the KOMPSAT-3 sensors in Goheung, South Korea, were significant for multispectral bands. A cross calibration method based on the Landsat-8 OLI was also used to assess the two sensors using near simultaneous image pairs over the Libya-4 PICS (Pseudo Invariant Calibration Sites). The spectral profile of the target was obtained from EO-1 (Earth Observing-1) Hyperion data over the Libya-4 PICS to derive the SBAF (Spectral Band Adjustment Factor). The results revealed that the TOA radiance of the KOMPSAT-3 agree with Landsat-8 within 5.14% for all bands after applying the SBAF. The radiometric coefficient presented here appears to be a good standard for maintaining the optical quality of the KOMPSAT-3.

Eliminating Color Mixing of Projector-Camera System for Fast Radiometric Compensation (컬러 보정의 고속화를 위한 프로젝터-카메라 시스템의 컬러 혼합 성분 제거)

  • Lee, Moon-Hyun;Park, Han-Hoon;Park, Jong-Il
    • Journal of Broadcast Engineering
    • /
    • v.13 no.6
    • /
    • pp.941-950
    • /
    • 2008
  • The quality of projector output image is influenced by the surrounding conditions such as the shape and color of screen, and environmental light. Therefore, techniques that ensure desirable image quality, regardless of such surrounding conditions, have been in demand and are being steadily developed. Among the techniques, radiometric compensation is a representative one. In general, radiometric compensation is achieved by measuring the color of the screen and environmental light based on an analysis of camera image of projector output image and then adjusting the color of projector input image in a pixel-wise manner. This process is not time-consuming for small sizes of images but the speed of the process drops linearly with respect to image size. In large sizes of images, therefore, reducing the time required for performing the process becomes a critical problem. Therefore, this paper proposes a fast radiometric compensation method. The method uses color filters for eliminating the color mixing between projector and camera because the speed of radiometric compensation depends mainly on measuring color mixing between projector and camera. By using color filters, there is no need to measure the color mixing. Through experiments, the proposed method improved the compensation speed by 44 percent while maintaining the projector output image quality. This method is expected to be a key technique for widespread use of projectors for large-scale and high-quality display.