• 제목/요약/키워드: Radiometric correction coefficients

검색결과 5건 처리시간 0.019초

PROTOTYPE ALGORITHM OF RADIOMETRIC CALIBRATION FOR IR CHANNELS ON GOES-12

  • Chang Ki-Ho;Oh Tae-Hyung;Ahn Myung-Hwan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.691-693
    • /
    • 2005
  • The prototype of the radiometric calibration algorithm, including the correction of scan mirror's angle, has been developed for the stationary meteorological sensor, firstly in Korea. We use this system on GOES-12 to evaluate two coefficients, slope and intercept. The evaluated coefficients show good agreement with the NESDIS's results for the five-case data. The calculated coefficients have been applied to the conversion from the measured counts to the radiance and the converting methods according to the scanning are investigated to enhance the radiometric accuracy.

  • PDF

초분광센서와의 상호교정을 통한 RedEdge-MX 다분광 카메라의 보정계수 산출 (Calculation of correction coefficients for the RedEdge-MX multispectral camera through intercalibration with a hyperspectral sensor)

  • 백승일;고수윤;김원국
    • 한국측량학회지
    • /
    • 제38권6호
    • /
    • pp.707-716
    • /
    • 2020
  • 원격탐사 분야에서 물체의 특성을 정략적으로 추정할 수 있는 분광센서에 대한 관심이 늘어나고 있으며, 특히, 최근 드론에 탑재하여 운영할 수 있는 경량 다분광 카메라의 활용이 주목받고 있다. 정량적 원격탐사를 위해서는 카메라 또는 센서에서 획득된 복사량의 정확도가 중요하지만, 저가의 다분광 카메라의 경우 복사정확도에 대한 독립적인 검증이 충분히 수행되지 않았다. 본 연구에서는 최근 농작물 모니터링, 식생 분석, 수질 분석 등에 다양하게 활용되고 있는 MicaSense사의 RedEdge-MX 카메라에 대한 복사 정확도 분석을 수행하였다. 미국 NIST 표준에 따라 교정된 초분광 센서인 TriOS RAMSES를 이용하여, RedEdge-MX 센서의 복사휘도 및 복사조도에 대한 상대 보정계수를 산출하였다. 분석결과, RedEdge-MX의 복사휘도는 밴드별로 RAMSES보다 5~16% 가량 낮게 나타났고, 복사조도 역시 1~20% 가량 낮은 것이 확인되었다. 본 연구에서는 RedEdge-MX의 관측값을 RAMSES에 상응하는 값으로 변환시키기 위한 보정계수를 1차 그리고 3차 회귀분석을 통하여 제공한다.

Atmospheric Correction Problems with Multi-Temporal High Spatial Resolution Images from Different Satellite Sensors

  • Lee, Hwa-Seon;Lee, Kyu-Sung
    • 대한원격탐사학회지
    • /
    • 제31권4호
    • /
    • pp.321-330
    • /
    • 2015
  • Atmospheric correction is an essential part in time-series analysis on biophysical parameters of surface features. In this study, we tried to examine possible problems in atmospheric correction of multitemporal High Spatial Resolution (HSR) images obtained from two different sensor systems. Three KOMPSAT-2 and two IKONOS-2 multispectral images were used. Three atmospheric correction methods were applied to derive surface reflectance: (1) Radiative Transfer (RT) - based absolute atmospheric correction method, (2) the Dark Object Subtraction (DOS) method, and (3) the Cosine Of the Uun zeniTh angle (COST) method. Atmospheric correction results were evaluated by comparing spectral reflectance values extracted from invariant targets and vegetation cover types. In overall, multi-temporal reflectance from five images obtained from January to December did not show consistent pattern in invariant targets and did not follow a typical profile of vegetation growth in forests and rice field. The multi-temporal reflectance values were different by sensor type and atmospheric correction methods. The inconsistent atmospheric correction results from these multi-temporal HSR images may be explained by several factors including unstable radiometric calibration coefficients for each sensor and wide range of sun and sensor geometry with the off-nadir viewing HSR images.

Investigation of NESDIS's Calibration Algorithm of the Imagers for IR Channels on GOES-12

  • Chang, Ki-Ho;Oh, Tae-Hyung;Ahn, Myung-Hwan;Cho, Nam-Seo;Oh, Sung-Nam
    • 대한원격탐사학회지
    • /
    • 제23권1호
    • /
    • pp.55-58
    • /
    • 2007
  • The prototype radiometric calibration algorithm of the imagers for IR channels has been developed according to the Weinreb's method. Applying the algorithm to the GOES-12 count data, we have shown that the calibration coefficients (slope and intercept) evaluated by the algorithm gives good agreement with the NESDIS's ones, and that the scanning error due to the scan mirror emissivity and stripe error are almost eliminated by the East/West angle dependent scan-mirror correction and the respective calculation of intercept for each North/South scan line, respectively.

지상 초분광카메라 영상의 복사보정 (Vicarious Radiometric Calibration of the Ground-based Hyperspectral Camera Image)

  • 신정일;;김선화;강성진;이규성
    • 대한원격탐사학회지
    • /
    • 제24권2호
    • /
    • pp.213-222
    • /
    • 2008
  • 초분광영상의 활용 가능성은 증대하고 있으나, 연구에 필요한 초분광센서의 공급은 비교적 제한되어 있다. 초분광영상으로부터 정보 획득을 위한 처리와 분석은 대부분 영상에서 획득되는 분광반사율에 기반을 두고 있다. 본 연구의 목표는 사전 복사보정 자료가 없는 지상 초분광카메라 영상의 복사보정 과정을 개발하여 영상의 화소값을 분광반사율로 변환하고자 한다. 다양한 분광반사특성을 가진 22개 클래스로 구성된 모의지표물을 대상으로 분광측정기를 이용한 대리 복사보정 절차를 수행하였다 분광측정기로 측정된 복사량과 영상의 화소값의 관계를 이용하여 120개 밴드 초분광영상의 화소값을 센서감지 복사량(radiance)로 변환하는 보정계수를 도출하였다. 영상 촬영 및 분광측정이 대기의 영향이 거의 없는 지상 근접 촬영으로 이루어졌기 때문에, 화소값을 반사율(reflectance)로 직접 변환하는 보정계수도 산출하였다. 그러나 원거리 촬영이나 공중 촬영으로 획득된 영상의 경우 산출된 복사보정 계수는 센서감지 복사량 변환에만 유효하며, 반사율을 얻기 위해서는 추가적인 대기보정 절차가 별도로 수행되어야 한다.