• Title/Summary/Keyword: Radiometric Calibration

Search Result 107, Processing Time 0.023 seconds

Development of relative radiometric calibration system for in-situ measurement spectroradiometers (현장관측용 분광 광도계의 상대 검교정 시스템 개발)

  • Oh, Eunsong;Ahn, Ki-Beom;Kang, Hyukmo;Cho, Seong-Ick;Park, Young-Je
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.4
    • /
    • pp.455-464
    • /
    • 2014
  • After launching the Geostationary Ocean Color Imager (GOCI) on June 2010, field campaigns were performed routinely around Korean peninsula to collect in-situ data for calibration and validation. Key measurements in the campaigns are radiometric ones with field radiometers such as Analytical Spectral Devices FieldSpec3 or TriOS RAMSES. The field radiometers must be regularly calibrated. We, in the paper, introduce the optical laboratory built in KOSC and the relative calibration method for in-situ measurement spectroradiometer. The laboratory is equipped with a 20-inch integrating sphere (USS-2000S, LabSphere) in 98% uniformity, a reference spectrometer (MCPD9800, Photal) covering wavelengths from 360 nm to 1100 nm with 1.6 nm spectral resolution, and an optical table ($3600{\times}1500{\times}800mm^3$) having a flatness of ${\pm}0.1mm$. Under constant temperature and humidity maintainance in the room, the reference spectrometer and the in-situ measurement instrument are checked with the same light source in the same distance. From the test of FieldSpec3, we figured out a slight difference among in-situ instruments in blue band range, and also confirmed the sensor spectral performance was changed about 4.41% during 1 year. These results show that the regular calibrations are needed to maintain the field measurement accuracy and thus GOCI data reliability.

Development of SOC DATS C&M (Control and Monitoring) S/W

  • Koo, In-Hoi;Kim, Su-Jin;Ahn, Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.602-605
    • /
    • 2007
  • COMS SOC is supposed to operate IDACS as a backup of MSC. For the backup operation, there is a route between SOC and MSC for exchanging current version such as radiometric calibration for IMPS, dissemination schedule, encryption key and conversion table for LHGS. DATS C&M S/W is basically designed to control and monitor DATS equipment. However, its capability is extended to monitor the working status of IMPS, LHGS and even MSC IDACS. In addition, DATS C&M SIW can display discrepancy between MSC and SOC when applied version is different each other. This paper presents detailed description on the development of DATS C&M S/W.

  • PDF

Relative radiometric calibration for the SOC700 hyperspectral image with spectroradiometer (분광측정기를 이용한 초분광카메라 영상의 상대 복사보정)

  • Shin, Jung-Il;Maghsoudi, Yasser;Kang, Sung-Jin;Lee, Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.69-73
    • /
    • 2008
  • 초분광영상을 이용한 정량적인 분석이나 분광라이브러리를 이용한 목표물의 탐지를 위해서는 복사보정이 필수적이지만 사전 검보정 자료가 없는 센서의 경우 절대 복사 보정을 실시할 수 없다. 본 연구의 목표는 사전 검보정 자료가 없는 지상 초분광 카메라 (SOC700) 영상의 화소값을 spectroradiometer의 radiance로 변환하기 위한 상대 변환계수(gain, offset coefficient)를 산출하고 그 적합성을 판단하는 것이다. 초분광영상의 DN과 동시에 측정된 radiance의 밴드별 선형 회귀분석을 통하여 상대 radiance 변환계수를 산출하였다. 산출된 선형 회귀식의 적합도($R^2$)는 대부분이 0.9 이상으로 매우 양호하였으며 상대 radiance를 이용할 경우 상대 분광반사율 획득이 가능하며 이를 통해 보다 초분광영상에 적합한 정량적인 분석을 할 수 있다.

  • PDF

Radiation and Decommissioning Laboratory, an R&D Center for the Back-end Cycle of Nuclear Power Plants

  • Cheon-Woo Kim
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.3
    • /
    • pp.419-425
    • /
    • 2023
  • The Radiation and Decommissioning Laboratory of Central Research Institute (CRI) of Korea Hydro and Nuclear Power Co. (KHNP) performs research to technically support the effective management of radiological hazards to avoid risks to civilians, the workers, and the environment from the radiological risks. The laboratory mainly consists of three technical groups: decommissioning and SF technology group, radiation and chemistry group, and radwaste and environment group. The groups carry out various R&D such as decommissioning, spent fuel management, radiation protection, water chemistry management, and radioactive waste management. The laboratory also technically supports the calibration of radiometric instruments as a Korea Laboratory Accreditation Scheme (KOLAS), approval for decommissioning, guidance for radioactive waste management, state-of-the-art technology evaluations, and technology transfer.

APPLICATION OF MERGED MICROWAVE GEOPHYSICAL OCEAN PRODUCTS TO CLIMATE RESEARCH AND NEAR-REAL-TIME ANALYSIS

  • Wentz, Frank J.;Kim, Seung-Bum;Smith, Deborah K.;Gentemann, Chelle
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.150-152
    • /
    • 2006
  • The DISCOVER Project (${\underline{D}}istributed$ ${\underline{I}}nformation$ ${\underline{S}}ervices$ for ${\underline{C}}limate$ and ${\underline{O}}cean$ products and ${\underline{V}}isualizations$ for ${\underline{E}}arth$ ${\underline{R}}esearch$) is a NASA funded Earth Science REASoN project that strives to provide highly accurate, carefully calibrated, long-term climate data records and near-real-time ocean products suitable for the most demanding Earth research applications via easy-to-use display and data access tools. A key element of DISCOVER is the merging of data from the multiple sensors on multiple platforms into geophysical data sets consistent in both time and space. The project is a follow-on to the SSM/I Pathfinder and Passive Microwave ESIP projects which pioneered the simultaneous retrieval of sea surface temperature, surface wind speed, columnar water vapor, cloud liquid water content, and rain rate from SSM/I and TMI observations. The ocean products available through DISCOVER are derived from multi-sensor observations combined into daily products and a consistent multi-decadal climate time series. The DISCOVER team has a strong track record in identifying and removing unexpected sources of systematic error in radiometric measurements, including misspecification of SSM/I pointing geometry, the slightly emissive TMI antenna, and problems with the hot calibration source on AMSR-E. This in-depth experience with inter-calibration is absolutely essential for achieving our objective of merging multi-sensor observations into consistent data sets. Extreme care in satellite inter-calibration and commonality of geophysical algorithms is applied to all sensors. This presentation will introduce the DISCOVER products currently available from the web site, http://www.discover-earth.org and provide examples of the scientific application of both the diurnally corrected optimally interpolated global sea surface temperature product and the 4x-daily global microwave water vapor product.

  • PDF

High Resolution Spaceborne SAR Operation and Target Recognition Simulator Using STK (STK를 이용한 고해상도 위성 SAR 운용 및 표적물 추출 기법)

  • Lee, Bo-Yun;Lee, Seul-Ki;Lee, Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.299-309
    • /
    • 2013
  • A comprehensive SAR(Synthetic Aperture Radar) simulation is considered to be a complicated task since a full knowledge of the signal propagation characteristics, antenna pattern, system internal errors and interference noises should be taken into account. In high resolution target application modes, the time varying nature of target RCS(Radar Cross Section) strongly affects the generated SAR images. In this paper, in-depth SAR simulations are performed and analyzed incorporating the STK tools and MATLAB software. STK provides realistic orbit parameters while its radar module helps to extract accurate radiometric parameters of ground targets. SAR raw data corresponding to a given target is generated and processed using MATLAB simulator. The performance is measured by PSLR(Peak Sidelobe Ratio) and ISLR(Integrated Sidelobe Ratio) for a point target, which can be used as reference parameters for accurate radiometric calibration. Finally, high resolution target simulations are performed by adopting time varying target RCS characteristics.

Degradation Monitoring of Visible Channel Detectors on COMS MI Using Moon Observation Images (달 관측 영상을 이용한 천리안위성 기상탑재체 가시채널 검출기의 성능감쇄 분석)

  • Seo, Seok-Bae;Jin, Kyoung-Wook
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.1
    • /
    • pp.115-121
    • /
    • 2013
  • The first geostationary satellite in Korea, COMS (Communication, Ocean, and Meteorological Satellite), has been operating properly since its successful completion of the IOT (In Orbit Test). COMS MI (Meteorological Imager) acquires Earth observation images from visible and infrared channels. This paper describes a method to compute the degradation of the COMS visible detectors and the result of the degradation during the two years of the operation. The visible channel detectors' performance was determined based on the comparison between the instrument-based measurements and ROLO model-based values. The degradation rate of the visible channel detectors of COMS MI showed a normal condition.

ATMOSPHERIC AEROSOL DETECTION AND ITS REMOVEAL FOR SATELLITE DATA

  • Lee, Dong-Ha;Lee, Kwon-Ho;Kim, Young-Joon
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.598-601
    • /
    • 2006
  • Satellite imagery may contain large regions covered with atmospheric aerosol. A high-resolution satellite imagery affected by non-homogenous aerosol cover should be processed for land cover study and perform the radiometric calibration that will allow its future application for Korea Multi-Purpose Satellite (KOMPSAT) data. In this study, aerosol signal was separated from high resolution satellite data based on the reflectance separation method. Since aerosol removal has a good sensitivity over bright surface such as man-made targets, aerosol optical thickness (AOT) retrieval algorithm could be used. AOT retrieval using Look-up table (LUT) approach for utilizing the transformed image to radiometrically compensate visible band imagery is processed and tested in the correction of satellite scenery. Moderate Resolution Imaging Spectroradiometer (MODIS), EO-1/HYPERION data have been used for aerosol correction and AOT retrieval with different spatial resolution. Results show that an application of the aerosol detection for HYPERION data yields successive aerosol separation from imagery and AOT maps are consistent with MODIS AOT map.

  • PDF

Retrieval of surface parameters in tidal flats using radar backscattering model and multi-frequency SAR data

  • Choe, Byung-Hun;Kim, Duk-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.3
    • /
    • pp.225-234
    • /
    • 2011
  • This study proposes an inversion algorithm to extract the surface parameters, such as surface roughness and soil moisture contents, using multi-frequency SAR data. The study areas include the tidal flats of Jebu Island and the reclaimed lands of Hwaong district on the western coasts of the Korean peninsula. SAR data of three frequencies were accordingly calibrated to provide precise backscattering coefficients through absolute radiometric calibration. The root mean square (RMS) height and the correlation length, which can describe the surface roughness, were extracted from the backscattering coefficients using the inversion of the Integral Equation Method (IEM). The IEM model was appropriately modified to accommodate the environmental conditions of tidal flats. Volumetric soil moisture was also simultaneously extracted from the dielectric constant using the empirical model, which define the relations between volumetric soil moistures and dielectric constants. The results obtained from the proposed algorithm were verified with the in-situ measurements, and we confirmed that multi-frequency SAR observations combined with the surface scattering model for tidal flats can be used to quantitatively retrieve the geophysical surface parameters in tidal flats.

위성 영상 탑재체에 관련된 영상품질 인자의 특성

  • Cho, Young-Min
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.66-74
    • /
    • 2002
  • The characteristics of the satellite image quality parameters driven by satellite imaging instrument are investigated. Since the satellite image is directly produced by the satellite imaging instrument, the satellite image quality depends on the imager performance highly. This is why the imager performance parameters are considered as an important part of the satellite image quality parameters. The imager performance parameters consist of spectral band parameters, ground sample distance(GSD) parameters, swath width parameters, imager Modulation Transfer Function (MTF), imager Signal to Noise Ratio(SNR), radiometric response characteristics parameters, pixel registration, and imager calibration.

  • PDF