• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.029 seconds

Volumetric accuracy of cone-beam computed tomography

  • Park, Cheol-Woo;Kim, Jin-ho;Seo, Yu-Kyeong;Lee, Sae-Rom;Kang, Ju-Hee;Oh, Song-Hee;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.165-174
    • /
    • 2017
  • Purpose: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Materials and Methods: Four geometric objects(cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. Results: The mean VE ranged from -4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. Conclusion: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.

Enzymatic properties of the N- and C-terminal halves of human hexokinase II

  • Ahn, Keun-Jae;Kim, Jong-Sun;Yun, Mi-Jin;Park, Jeon-Han;Lee, Jong-Doo
    • BMB Reports
    • /
    • v.42 no.6
    • /
    • pp.350-355
    • /
    • 2009
  • Although previous studies on hexokinase (HK) II indicate both the N- and C-terminal halves are catalytically active, we show in this study the N-terminal half is significantly more catalytic than the C-terminal half in addition to having a significantly higher $K_m$ for ATP and Glu. Furthermore, truncated forms of intact HK II lacking its first N-terminal 18 amino acids ($\Delta$18) and a truncated N-terminal half lacking its first 18 amino acids ($\Delta$18N) have higher catalytic activity than other mutants tested. Similar results were obtained by PET-scan analysis using $^{18}F-FDG$. Our results collectively suggest that each domain of HK II possesses enzyme activity, unlike HK I, with the N-terminal half showing higher enzyme activity than the C-terminal half.

The effects of digital image processing for noise reduction on observer performance (노이즈 감소 필터 사용이 판독능에 미치는 효과)

  • Jung, Young-Chul;Choi, Bo-Ram;Huh, Kyung-Hoi;Yi, Yon-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.40 no.3
    • /
    • pp.103-107
    • /
    • 2010
  • Purpose : This study was performed to examine the effects of image filter on observer performance by counting the number of holes at each wedge step on a radiographic image. Materials and Methods : An aluminum step wedge with 11 steps ranged in thickness from 1.5 mm to 16.5 mm in 1.5 mm increments was fabricated for this study. Each step had 10 notched holes with 1.0 mm diameter on the bottom of the step wedge which were ranged in depths from 0.1 mm to 1.0 mm in 0.1 mm increments. Digital radiographic raw images of the aluminum step wedge were acquired by using CCD intraoral sensor. The images were processed using several types of noise reduction filters and kernel sizes. Three observers counted the number of holes which could be discriminated on each step. The data were analyzed by ANOVA. Results : The number of holes at each step was decreased as the thickness of step was increased. The number of holes at each step on the raw images was significantly higher than that on the processed images. The number of holes was different according to the types and kernel sizes of the image filters. Conclusions : The types and kernel sizes of image filters on observer performance were important, therefore, they should be standardized for commercial digital imaging systems.

A Comparative Study of Survivor Outcomes between Preoperative Evaluation Using CT Alone and Combined CT and MRI in Patients with Pancreatic Ductal Adenocarcinoma (췌장선암 환자의 수술 전 CT 단독 평가와 추가적 MRI 평가에 따른 생존 결과 비교 분석)

  • Ji Eun Lee;Seong Hyun Kim;Soon Jin Lee;Seo-Youn Choi;Sunyoung Lee;Bo Ra Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.638-653
    • /
    • 2021
  • Purpose To compare the recurrence pattern, disease-free survival (DFS), and overall survival (OS) after curative surgery for pancreatic ductal adenocarcinoma (PDAC) in patients who underwent preoperative evaluation with CT alone or in combination with MRI, and to compare the prognosis according to the first recurrence site. Materials and Methods We retrospectively evaluated 152 patients who underwent R0 resection of PDAC. Preoperative CT or combined CT and MRI were performed for 103 and 49 patients, respectively. Two radiologists recorded the location and date of the first recurrence in consensus. The recurrence pattern, DFS, and OS were compared between the two groups. OS was analyzed according to the first recurrence site. Results In both groups, liver metastasis was the most common recurrence pattern. DFS (p = 0.247) or OS (p = 0.067) showed no significant difference between the two groups. OS according to the first recurrence site was the lowest for liver metastasis, followed by locoregional recurrence (p < 0.001). Conclusion There were no significant differences in the recurrence pattern, DFS, or OS between patients evaluated with preoperative CT alone or with CT and MRI after curative resection of PDAC. Liver metastasis was the most common tumor recurrence pattern with the lowest OS.

Findings of Endoscopic US and CT of Esophageal Disease (식도 질환의 내시경 초음파 및 전산화단층촬영 소견)

  • Su Min Yun;Jeong A Yeom;Ji Won Lee;Gwang Ha Kim;Kyung Jin Nam;Yeon Joo Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.5
    • /
    • pp.883-901
    • /
    • 2024
  • Various diseases can affect the esophagus. Endoscopic ultrasound (EUS), which provides precise information about the layers of the esophageal wall, is the primary approach used to investigate esophageal diseases. However, CT is one of the most important imaging modalities for diagnosing esophageal diseases as it can elucidate mediastinal involvement, adjacent lymphadenopathy, and distant disease spread. These two modalities complement each other in the diagnosis of esophageal diseases. Although radiologists may be unfamiliar with EUS procedures and their interpretation, understanding them aids in the differential diagnosis of esophageal conditions. This pictorial essay illustrates the EUS and CT findings of various esophageal diseases originating in the esophageal wall.

Comparison of static MRI and pseudo-dynamic MRI in tempromandibular joint disorder patients (측두하악관절장애 환자에서의 static MRI와 pseudo-dynamic MRI의 비교연구)

  • Lee, Jin-Ho;Yun, Kyoung-In;Park, In-Woo;Choi, Hang-Moon;Park, Moon-Soo
    • Imaging Science in Dentistry
    • /
    • v.36 no.4
    • /
    • pp.199-206
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate comparison of static MRI and pseudo-dynamic (cine) MRI in temporomandibular joint (TMJ) disorder patients. Materials and Methods: In this investigation, 33 patients with TMJ disorders were examined using both conventional static MRI and pseudo-dynamic MRI. Multiple spoiled gradient recalled acquisition in the steady state (SPGR) images were obtained when mouth opened and closed. Proton density weighted images were obtained at the closed and open mouth position in static MRI. Two oral and maxillofacial radiologists evaluated location of the articular disk, movement of condyle and bony change respectively and the posterior boundary of articular disk was obtained. Results: No statistically significant difference was found in the observation of articular disk position, mandibular condylar movement and posterior boundary of articular disk using static MRI and pseudo-dynamic MRI (P<0.05). Statistically significant difference was noted in bony changes of condyle using static MRI and pseudo-dynamic MRI (P<0.05). Conclusion: This study showed that pseudo-dynamic MRI didn't make a difference in diagnosing internal derangement of TMJ in comparison with static MRI. But it was considered as an additional method to be supplemented in observing bony change.

  • PDF

3D Reconstruction of Color Volume Data (칼라 볼륨 데이터의 3차원 입체 영상 재구성)

  • Kim, Bo-Hyoung;Lee, Cheol-Hi;Jung, Dong-Kyun;Shin, Yeong-Gil;Kim, Jong-Hyo;Kang, Heung-Sik
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.197-200
    • /
    • 1997
  • In this paper, we present a 3D reconstruction method of color volume data or a computerized human atlas. Binary volume rendering which takes the advantages of shear-warp factorization and new normal vector calculation method visualizes 3D organs in real time. Various manipulations such as rotation, multiple object rendering, removal, and transparency effect improve the usefulness and comprehensiveness of the computerized atlas.

  • PDF

Intraindividual Comparison of Hepatocellular Carcinoma Washout between MRIs with Hepatobiliary and Extracellular Contrast Agents

  • Yeun-Yoon Kim;Young Kon Kim;Ji Hye Min;Dong Ik Cha;Jong Man Kim;Gyu-Seong Choi;Soohyun Ahn
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.725-734
    • /
    • 2021
  • Objective: To intraindividually compare hepatocellular carcinoma (HCC) washout between MRIs using hepatobiliary agent (HBA) and extracellular agent (ECA). Materials and Methods: This study included 114 prospectively enrolled patients with chronic liver disease (mean age, 55 ± 9 years; 94 men) who underwent both HBA-MRI and ECA-MRI before surgical resection for HCC between November 2016 and May 2019. For 114 HCCs, the lesion-to-liver visual signal intensity ratio (SIR) using a 5-point scale (-2 to +2) was evaluated in each phase. Washout was defined as negative visual SIR with temporal reduction of visual SIR from the arterial phase. Illusional washout (IW) was defined as a visual SIR of 0 with an enhancing capsule. The frequency of washout and MRI sensitivity for HCC using LR-5 or its modifications were compared between HBA-MRI and ECA-MRI. Subgroup analysis was performed according to lesion size (< 20 mm or ≥ 20 mm). Results: The frequency of portal venous phase (PP) washout with HBA-MRI was comparable to that of delayed phase (DP) washout with ECA-MRI (77.2% [88/114] vs. 68.4% [78/114]; p = 0.134). The frequencies were also comparable when IW was allowed (79.8% [91/114] for HBA-MRI vs. 81.6% [93/114] for ECA-MRI; p = 0.845). The sensitivities for HCC of LR-5 (using PP or DP washout) were comparable between HBA-MRI and ECA-MRI (78.1% [89/114] vs. 73.7% [84/114]; p = 0.458). In HCCs < 20 mm, the sensitivity of LR-5 was higher on HBA-MRI than on ECA-MRI (70.8% [34/48] vs. 50.0% [24/48]; p = 0.034). The sensitivity was similar to each other if IW was added to LR-5 (72.9% [35/48] for HBA-MRI vs. 70.8% [34/48] for ECA-MRI; p > 0.999). Conclusion: Extracellular phase washout for HCC diagnosis was comparable between MRIs with both contrast agents, except for tumors < 20 mm. Adding IW could improve the sensitivity for HCC on ECA-MRI in tumors < 20 mm.

Immunoglobulin G4-Related Disease in the Diaphragm: A Case Report (횡격막에 발생한 면역글로불린 G4 연관 질환: 증례 보고)

  • Jin Woo Kim;Taehwa Kim;Kun-Il Kim;Yeon Joo Jeong;Dohyung Kim;Dong Hoon Shin;Yun Seong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.5
    • /
    • pp.954-959
    • /
    • 2024
  • Immunoglobulin G4-related disease (IgG4-RD) is an immune-mediated condition characterized by mass-forming inflammation with a sclerosing pattern that can affect nearly any organ. However, involvement of the diaphragm in IgG4-RD is exceptionally rare. We present the case of a 62-year-old male patient with chest radiographic abnormalities. Further investigation with CT revealed an infiltrative mass in the right hemidiaphragm. This mass, composed of engorged feeding vessels, an atypical manifestation of IgG4-RD, was also associated with lymphadenopathy. Surgical excision confirmed the presence of IgG4-positive cell infiltration, solidifying the diagnosis of IgG4-RD. Notably, the patient remained asymptomatic and did not require any treatment postoperatively. This case highlights the uncommon presentation of IgG4-RD as an infiltrative diaphragmatic mass.

Radiomics Analysis of Gray-Scale Ultrasonographic Images of Papillary Thyroid Carcinoma > 1 cm: Potential Biomarker for the Prediction of Lymph Node Metastasis (Radiomics를 이용한 1 cm 이상의 갑상선 유두암의 초음파 영상 분석: 림프절 전이 예측을 위한 잠재적인 바이오마커)

  • Hyun Jung Chung;Kyunghwa Han;Eunjung Lee;Jung Hyun Yoon;Vivian Youngjean Park;Minah Lee;Eun Cho;Jin Young Kwak
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.185-196
    • /
    • 2023
  • Purpose This study aimed to investigate radiomics analysis of ultrasonographic images to develop a potential biomarker for predicting lymph node metastasis in papillary thyroid carcinoma (PTC) patients. Materials and Methods This study included 431 PTC patients from August 2013 to May 2014 and classified them into the training and validation sets. A total of 730 radiomics features, including texture matrices of gray-level co-occurrence matrix and gray-level run-length matrix and single-level discrete two-dimensional wavelet transform and other functions, were obtained. The least absolute shrinkage and selection operator method was used for selecting the most predictive features in the training data set. Results Lymph node metastasis was associated with the radiomics score (p < 0.001). It was also associated with other clinical variables such as young age (p = 0.007) and large tumor size (p = 0.007). The area under the receiver operating characteristic curve was 0.687 (95% confidence interval: 0.616-0.759) for the training set and 0.650 (95% confidence interval: 0.575-0.726) for the validation set. Conclusion This study showed the potential of ultrasonography-based radiomics to predict cervical lymph node metastasis in patients with PTC; thus, ultrasonography-based radiomics can act as a biomarker for PTC.