• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.028 seconds

A rare case of Ewing sarcoma metastasis to the oral cavity

  • Schulz, Rieli Elis;de Lima, Matheus Henrique Alves;Lopes, Rodrigo Nascimento;Pinto, Clovis Antonio Lopes;Nicolau, Ulisses Ribaldo;Araujo, Juliane Piragine
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.217-222
    • /
    • 2021
  • Ewing sarcoma in the head and neck is rare, and metastasis from other bones to the mandible accounts for 0.7% of cases. This report presents a case of oral metastasis in a 24-year-old male patient diagnosed with Ewing sarcoma of the femur (p53 gene mutation and EWSR1-ERG fusion). The chief complaint was numbness in the mandible and pain for 1 month and a hardened, ulcerated exophytic lesion in the right retromolar region. Imaging exams revealed an unspecified thinning of the cortical bone of the inferior alveolar canal in the right mandibular ramus, associated with erosion of the alveolar bone. Histopathological analysis confirmed metastasis of Ewing sarcoma. The patient presented an aggressive disease progression and died 1 month after the oral diagnosis. It is important to recognize the signs and symptoms compatible with rare clinical outcomes, leading to an early diagnosis that can improve patients' quality of life and survival.

Importance of 3-dimensional imaging in the early diagnosis of chondroblastic osteosarcoma

  • Laura Althea Cuschieri;Rebecca Schembri-Higgans;Nicholas Bezzina;Alexandra Betts;Arthur Rodriguez Gonzalez Cortes
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.247-256
    • /
    • 2023
  • The aim of this report is to present a case of chondroblastic osteosarcoma located in the right maxillary premolar region of a 17-year-old female patient. The initial clinical presentation and 2-dimensional (2D) radiographic methods proved inadequate for a definitive diagnosis. However, a cone-beam computed tomography scan revealed a hyperdense, heterogeneous lesion in the right maxillary premolar region, exhibiting a characteristic "sun-ray" appearance. To assess soft tissue involvement, a medical computed tomography scan was subsequently conducted. A positron emission tomography scan detected no metastasis or indications of secondary tumors. T1- and T2-weighted magnetic resonance imaging showed signal heterogeneity within the lesion, including areas of low signal intensity at the periphery. Histological examination conducted after an incisional biopsy confirmed the diagnosis of highgrade chondroblastic osteosarcoma. The patient was then referred to an oncology department for chemotherapy before surgery. In conclusion, these findings suggest that early diagnosis using 3-dimensional imaging can detect chondroblastic osteosarcoma in its early stages, such as before metastasis occurs, thereby improving the patient's prognosis.

Laparoscopic distal pancreatosplenectomy for left-sided pancreatic cancer in patients with radical subtotal gastrectomy for gastric cancer

  • Kang Hee Lee;Seung Soo Hong;Seung-seob Kim;Ho Kyoung Hwang;Woo Jung Lee;Chang Moo Kang
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.26 no.4
    • /
    • pp.395-400
    • /
    • 2022
  • After radical subtotal gastrectomy (RSTG) for stomach cancer, the remnant stomach is supposed to be perfused through the short gastric vessels. What if a patient who received previous RSTG is diagnosed with resectable distal pancreatic cancer? Can radical distal pancreatosplenectomy (DPS) be performed safely without ischemic damage to the remnant stomach? Unfortunately, there are limited studies on this specific clinical issue. Notably, in spite of rare clinical presentation, it is expected to increase due to prolonged survival of patients with resected gastric cancer. Therefore, we aimed to demonstrate the safety and feasibility of the radical DPS in patients with previous RSTG. In this study, we investigated perioperative and long-term survival outcomes of DPS for left-sided pancreatic cancer in patients with previous RSTG.

In vivo quantification of mandibular bone remodeling and vascular changes in a Wistar rat model: A novel HR-MRI and micro-CT fusion technique

  • Song, Dandan;Shujaat, Sohaib;Zhao, Ruiting;Huang, Yan;Shaheen, Eman;Van Dessel, Jeroen;Orhan, Kaan;Velde, Greetje Vande;Coropciuc, Ruxandra;Pauwels, Ruben;Politis, Constantinus;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.199-208
    • /
    • 2020
  • Purpose: This study was performed to introduce an in vivo hybrid multimodality technique involving the coregistration of micro-computed tomography (micro-CT) and high-resolution magnetic resonance imaging (HR-MRI) to concomitantly visualize and quantify mineralization and vascularization at follow-up in a rat model. Materials and Methods: Three adult female rats were randomly assigned as test subjects, with 1 rat serving as a control subject. For 20 weeks, the test rats received a weekly intravenous injection of 30 ㎍/kg zoledronic acid, and the control rat was administered a similar dose of normal saline. Bilateral extraction of the lower first and second molars was performed after 10 weeks. All rats were scanned once every 4 weeks with both micro-CT and HR-MRI. Micro-CT and HR-MRI images were registered and fused in the same 3-dimensional region to quantify blood flow velocity and trabecular bone thickness at T0 (baseline), T4 (4 weeks), T8 (8 weeks), T12 (12 weeks), T16 (16 weeks), and T20 (20 weeks). Histological assessment was the gold standard with which the findings were compared. Results: The histomorphometric images at T20 aligned with the HR-MRI findings, with both test and control rats demonstrating reduced trabecular bone vasculature and blood vessel density. The micro-CT findings were also consistent with the histomorphometric changes, which revealed that the test rats had thicker trabecular bone and smaller marrow spaces than the control rat. Conclusion: The combination of micro-CT and HR-MRI may be considered a powerful non-invasive novel technique for the longitudinal quantification of localized mineralization and vascularization.

Evaluation the absorbed dose in brain of dental radiography (치과방사선 검사에서 두부(brain)의 흡수선량 평가)

  • Jeon, Woon-Sun;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.343-349
    • /
    • 2011
  • This study was aimed to evaluate the absorbed dose in brain of dental radiography. For radiographic exposure, PLD(photoluminescence dosimetry) chips placed in Rando phantom to measurement the absorbed dose to pituitary gland, orbit, maxillary sinus and submandibular glands, thyroid gland, esophagus. Equipments were used Kodak 2200, Kodak 8000C dental radiographic systems and computed tomography(Lightspeed VCT). The absorbed doses were measured at the same exposure parameters and distance by the clinical factor(kV, mA, sec). The result were as follows ; The absorbed dose for intra-oral radiography were 0.02~2.47cGy, the greatest absorbed dose was 2.47cGy for thyroid gland in maxillary right molar projection. the lowest adsorbed dose was 0.02cGy for submandibular glands in lower anterior projection. The absorbed dose for extra-oral radiography were 0.36~3.44cGy of cephalometric method, 0.14~12.82cGy of panoramic method, 8.17~253.63cGy of computed tomography, the greatest adsorbed dose was 253.63cGy for submandibular glands in maxillary CT scan. the lowest adsorbed dose was 0.14cGy for orbit in panoramic method. As a result, extra-oral radiography was measured more than intra-oral radiography. In particular, method which used computed tomography was measured more than 100 times than intra-oral radiography highly. Therefore, you must show a guideline in extra-oral radiography and an effort to reduce absorbed dose is demanded.

A retrospective observational study of the BMD for 5-years in older men (성인 남성에서 5년간의 골밀도 변화 관찰)

  • Kim, Sun-Geun;Kweon, Dae-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.171-178
    • /
    • 2011
  • To investigate the decrease of BMD by age and the risk factor of osteoporosis in Korean men. We describe the study of a five-years retrospective observational study with male patients. Eighty Korean men who visited hospital for health screening were assessed for this study from 2002 to 2006. We evaluated the BMD of the femoral neck and L-spine, and the preferences and habits in the life. The data were collected for 5 years, and we analysed the five-years change of BMD and the relations between BMD and other factors. Subjects were divided into 3 group by 1st assessment of femoral neck BMD, and were compared with each other. The age of subjects was $43.15{\pm}4.82$ and BMD of femoral neck was $-0.61{\pm}0.97$ and BMD of L-spine was $-0.67{\pm}1.10$ in the first year assessment. The femoral neck BMD of 4th and 5th assessment was decreased significantly compared to that of 1st assessment. The L-spine BMD of 2nd assessment was decreased significantly compared to the 1st assessment. There was no significant correlation between the changes of BMD and preferences or habits-drinking, smoking, eating habit, exercise. The femoral neck BMD of 5th assessment was decreased significantly compared to that of 1st assessment in the high femoral neck BMD group. And there was no significant change of femoral BMD and L-spine BMD in other groups. Low BMD group in the 1st assessment showed lowest BMD in the 5th assessment and high BMD group in the 1st assessment showed highest BMD in the 5th assessment. We can guess that the young men who has low BMD could have high risk of osteoporosis when he became older. And the femoral BMD should be considered important in anticipating the changes of BMD in middle aged men.

Usefulness of Color-overlay Pattern of Breast Elastic Ultrasonography (유방 탄성초음파의 Color overlay pattern에 대한 유용성)

  • An, Hyun;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.401-406
    • /
    • 2017
  • Breast cancer rates are increasing every year, biopsy for diagnosing breast cancer is increasing as well. Biopsy also invasive test, have bad side effects from patients anxiety, infection, bleeding. In this study, Conduct a survey of 69 patients who brest lesion patient, both B-mode ultrasound and elastography exam and B-mode ultrasound was classified according to the BI-RADS category, and the elastography exam was classified according to the Color overlay pattern that the value of the kPa expressed in relation to the propagation velocity of Transverse waves. The optimal cut off value of the highest sensitivity and specificity was 54.70 kPa. In the color overlay pattern, Dark Blue 42 people, Light blue ~ Red 27 people classified results and BI-RADS classification results, benign 40 people and malignant 29 people classified results showed similar results. Therefore, It is judged that the color overlay pattern is positive when classified into Dark Blue, and malignant when classified into Light blue ~ Red. In conclusion, breast elastography is expected to play a innovative role in reducing the number of breast cancer examinations and classify between benign and malignant tumor.

The Anode Heel Effect caused by changing the Angle of X-Ray Tube (X-선관 각도 변경에 따른 Anode Heel Effect)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.435-442
    • /
    • 2016
  • This study was an investigation of the anode heel effect caused by changing the angle of the x-ray tube. We established the following conditions for experimental measurements: 70 kV, 30 mAs, focus-detector distance of 100cm, and a collimator setting of $35{\times}43cm^2$. The measurement points were set up at the center of the collimator and extended to each side in intervals of 3.5cm, with points A1, A2, A3, A4, A5, A6 on the anode side and points C1, C2, C3, C4, C5, C6 on the cathode side. We measured the entrance surface dose from point A6 to point C6 with each point perpendicular to an x-ray tube. And we did the same when measuring different angles of the x-ray tube from 15 to 30 degrees for every point on the anode and cathode sides. Using perpendicular x-ray tube, we found that the entrance surface dose of the A5 point was three times higher than that of the C5 point. Thus, we conclude that if the anode side is placed near highly radiosensitive organs, then there will be less radiation exposure when using a perpendicular x-ray tube. When imaging using x-ray tube angles, an angle to the cathode side can reduce the gap of the entrance surface dose on both the anode and cathode sides. When imaging areas where there are differences in thickness between the upper and lower sides, the angle to the cathode side that is closer to the thicker area can reduce the gap of the entrance surface dose and capture a higher quality image.

Application of Computer-Aided Diagnosis for the Differential Diagnosis of Fatty Liver in Computed Tomography Image (전산화단층촬영 영상에서 지방간의 감별진단을 위한 컴퓨터보조진단의 응용)

  • Park, Hyong-Hu;Lee, Jin-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.443-450
    • /
    • 2016
  • In this study, we are using a computer tomography image of the abdomen, as an experimental linear research for the image of the fatty liver patients texture features analysis and computer-aided diagnosis system of implementation using the ROC curve analysis, from the computer tomography image. We tried to provide an objective and reliable diagnostic information of fatty liver to the doctor. Experiments are usually a fatty liver, via the wavelet transform of the abdominal computed tomography images are configured with the experimental image section, shows the results of statistical analysis on six parameters indicating a feature value of the texture. As a result, the entropy, average luminance, strain rate is shown a relatively high recognition rate of 90% or more, the control also, flatness, uniformity showed relatively low recognition rate of about 70%. ROC curve analysis of six parameters are all shown to 0.900 (p = 0.0001) or more, showed meaningful results in the recognition of the disease. Also, to determine the cut-off value for the prediction of disease six parameters. These results are applicable from future abdominal computed tomography images as a preliminary diagnostic article of diseases automatic detection and eventual diagnosis.

An Evaluation of Usefulness of FEES Method using Full HD Video that Improves Diagnostic Value of VFSS (Full HD 동영상을 이용한 FEES법이 VFSS의 진단적 가치를 향상 시키는 유용성에 대한 평가)

  • Kim, Young-Ran;Kim, Young-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.678-685
    • /
    • 2016
  • Deglutition inspection has been the gold standard for inspection of dysphagia using a penetration device of the division of radiology to date. However, inspection using an endoscope has facilitated diagnosis of dysphagia in recent days. In this study, we compared the results of VFSS alone with those of VFSS combined with FEES to determine if the detection rate of penetration, aspiration, and pharyngeal residue increased. This study evaluated at 130 persons who underwent both VFSS and FEES from December 2013 through March 2014, and used VFSS (FELAVISION, SHIMADZU) and FESS (EVIU LUCERA CV-260SL, OLYMPUS) as devices. After preparing barium diluted solution, yogurt that diluted barium and rice that diluted barium in 2.5 ml, 5 ml, 10 ml by modifying Logemann's protocol in part, and having subjects take the solution, this study confirmed pharyngeal residue, penetration, aspiration etc. VFFS and FEES using full HD video revealed aspiration in 36 of the 130 patients in both inspections. Additionally, aspiration was discovered in 36 patients upon VFFS, but in 41 upon FESS. Although FEES was more sensitive at diagnosing dysphagia, the two inspection methods are complementary, so diagnostic value will be greatly improved when the endoscope operating method and accurate fluoroscopic inspection are combined.