• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.032 seconds

Mandibular canal branches supplying the mandibular third molar observed on cone beam computed tomographic images: Reports of four cases (콘빔형 전단화단층영상에서 관찰되는 하악관 분지 4 증례)

  • Lee, Jae-Seo;Yoon, Suk-Ja;Kang, Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.39 no.4
    • /
    • pp.209-212
    • /
    • 2009
  • Bifid mandibular canal can be an anatomic variation. This condition can lead to complication when performing mandibular anesthesia or during extraction of lower third molar, placement of implants and surgery in the mandible. Four patients underwent preoperative imaging for extraction of third molars using CBCT (CB Mercuray, Hitachi, Japan). The axial images were processed with CBworks program 2.1 (CyberMed Inc., Seoul, Korea). The branches for supplying the lower third molar were identified mainly on cross-sectional and panoramic images of CBCT. Since the location and configuration of mandibular canal variations are important in any mandibular surgical procedures, we report 4 cases of bifid mandibular canal with panoramic and the CBCT images.

  • PDF

Measurement of Focal Spot Size of Heavy Loaded X-ray Tubes (X선관의 실효초점 측정에 관한 고찰)

  • Chang, Kwang-Hyun;Lim, Oh-Soo;Kim, Hyung-Kee;Song, Chang-Wook;Cheung, Kyung-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.101-106
    • /
    • 1993
  • In order to assure safety of both patient and operator, and to provide uniform quality radiographs, it is necessary to perform periodic calibration of diagnostic X-ray equipment. A basic parameter of diagnostic equipment's and its image sharpness is the size(and shape the energy distribution) of the focal spot as viewed along the central X-ray beam. This size determines the resolution possible with the equipment and also determines the heat characteristics of an anode. A fine focus tube gives high resolution but causes high local heating of target. In past, the pin-hole and star pattern image measurement for evaluation of resolution have been widely used, but it produced blurring and inaccuracy of image. So newly inverted Ug-meter has advantage in more convenient measurement method and less out-put bias than other image measurement. The authors intended to compare measured focal size between Ug-meter and focal spot test tool, changed state from setting to now of units.

  • PDF

A case report of an unusual temporomandibular joint mass: Nodular fasciitis

  • Han-Sol Lee;Kyu-Young Oh;Ju-Hee Kang;Jo-Eun Kim;Kyung-Hoe Huh;Won-Jin Yi;Min-Suk Heo;Sam-Sun Lee
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.83-89
    • /
    • 2023
  • Nodular fasciitis (NF) is a benign myofibroblastic proliferation that grows very rapidly, mimicking a sarcoma on imaging. It is treated by local excision, and recurrence has been reported in only a few cases, even when excised incompletely. The most prevalent diagnoses of temporomandibular joint(TMJ) masses include synovial chondromatosis, pigmented villonodular synovitis, and sarcomas. Cases of NF in the TMJ are extremely rare, and only 3 cases have been reported to date. Due to its destructive features and rarity, NF has often been misdiagnosed as a more aggressive lesion, which could expose patients to unnecessary and invasive treatment approaches beyond repair. This report presents a case of NF in the TMJ, focusing on various imaging features, along with a literature review aiming to determine the hallmark features of NF in the TMJ and highlight the diagnostic challenges.

Cardiac CT for Measurement of Right Ventricular Volume and Function in Comparison with Cardiac MRI: A Meta-Analysis

  • Jin Young Kim;Young Joo Suh;Kyunghwa Han;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.450-461
    • /
    • 2020
  • Objective: We performed a meta-analysis to evaluate the agreement of cardiac computed tomography (CT) with cardiac magnetic resonance imaging (CMRI) in the assessment of right ventricle (RV) volume and functional parameters. Materials and Methods: PubMed, EMBASE, and Cochrane library were systematically searched for studies that compared CT with CMRI as the reference standard for measurement of the following RV parameters: end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), or ejection fraction (EF). Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and correlation coefficient (r) between CT and CMRI. Heterogeneity was also assessed. Subgroup analyses were performed based on the probable factors affecting measurement of RV volume: CT contrast protocol, number of CT slices, CT reconstruction interval, CT volumetry, and segmentation methods. Results: A total of 766 patients from 20 studies were included. Pooled bias and LOA were 3.1 mL (-5.7 to 11.8 mL), 3.6 mL (-4.0 to 11.2 mL), -0.4 mL (5.7 to 5.0 mL), and -1.8% (-5.7 to 2.2%) for EDV, ESV, SV, and EF, respectively. Pooled correlation coefficients were very strong for the RV parameters (r = 0.87-0.93). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, an RV-dedicated contrast protocol, ≥ 64 CT slices, CT volumetry with the Simpson's method, and inclusion of the papillary muscle and trabeculation had a lower pooled bias and narrower LOA. Conclusion: Cardiac CT accurately measures RV volume and function, with an acceptable range of bias and LOA and strong correlation with CMRI findings. The RV-dedicated CT contrast protocol, ≥ 64 CT slices, and use of the same CT volumetry method as CMRI can improve agreement with CMRI.

Survival Rates of Breast Cancer Patients Aged 40 to 49 Years according to Detection Modality in Korea: Screening Ultrasound versus Mammography

  • So Yeon Won;Hyung Seok Park;Eun-Kyung Kim;Seung Il Kim;Hee Jung Moon;Jung Hyun Yoon;Vivian Youngjean Park;Seho Park;Min Jung Kim;Young Up Cho;Byeong-Woo Park
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.159-167
    • /
    • 2021
  • Objective: The aim of this study was to compare the survival rates of Korean females aged 40 to 49 years with breast cancer detected by supplemental screening ultrasound (US) or screening mammography alone. Materials and Methods: This single-institution retrospective study included 240 patients with breast cancer (mean age, 45.1 ± 2.8 years) detected by US or mammography who had undergone breast surgery between 2003 and 2008. Medical records were reviewed for clinicopathologic characteristics and detection methods. Disease-free survival (DFS) and overall survival (OS) were compared between patients with breast cancer in the US and mammography groups using the log-rank test. Multivariable cox regression analysis was used to identify independent variables associated with DFS and OS. Results: Among the 240 cases of breast cancer, 43 were detected by supplemental screening US and 197 by screening mammography (mean follow-up: 7.4 years, 93.3% with dense breasts). There were 19 recurrences and 16 deaths, all occurring in the mammography group. While the US group did not differ from the mammography group in tumor stage, the patients in this group were more likely to undergo breast-conserving surgery and radiation therapy than the mammography group. The US group also showed better DFS (p = 0.016); however, OS did not differ between the two groups (p = 0.058). In the multivariable analysis, the US group showed a lower risk of recurrence (hazard ratio, 0.097; 95% confidence interval, 0.001-0.705) compared to the mammography group. Conclusion: Our study found that Korean females aged 40-49 years with US-detected breast cancer showed better DFS than those with mammography-detected breast cancer. However, there were no statistically significant differences in OS.

Development and Validation of MRI-Based Radiomics Models for Diagnosing Juvenile Myoclonic Epilepsy

  • Kyung Min Kim;Heewon Hwang;Beomseok Sohn;Kisung Park;Kyunghwa Han;Sung Soo Ahn;Wonwoo Lee;Min Kyung Chu;Kyoung Heo;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.12
    • /
    • pp.1281-1289
    • /
    • 2022
  • Objective: Radiomic modeling using multiple regions of interest in MRI of the brain to diagnose juvenile myoclonic epilepsy (JME) has not yet been investigated. This study aimed to develop and validate radiomics prediction models to distinguish patients with JME from healthy controls (HCs), and to evaluate the feasibility of a radiomics approach using MRI for diagnosing JME. Materials and Methods: A total of 97 JME patients (25.6 ± 8.5 years; female, 45.5%) and 32 HCs (28.9 ± 11.4 years; female, 50.0%) were randomly split (7:3 ratio) into a training (n = 90) and a test set (n = 39) group. Radiomic features were extracted from 22 regions of interest in the brain using the T1-weighted MRI based on clinical evidence. Predictive models were trained using seven modeling methods, including a light gradient boosting machine, support vector classifier, random forest, logistic regression, extreme gradient boosting, gradient boosting machine, and decision tree, with radiomics features in the training set. The performance of the models was validated and compared to the test set. The model with the highest area under the receiver operating curve (AUROC) was chosen, and important features in the model were identified. Results: The seven tested radiomics models, including light gradient boosting machine, support vector classifier, random forest, logistic regression, extreme gradient boosting, gradient boosting machine, and decision tree, showed AUROC values of 0.817, 0.807, 0.783, 0.779, 0.767, 0.762, and 0.672, respectively. The light gradient boosting machine with the highest AUROC, albeit without statistically significant differences from the other models in pairwise comparisons, had accuracy, precision, recall, and F1 scores of 0.795, 0.818, 0.931, and 0.871, respectively. Radiomic features, including the putamen and ventral diencephalon, were ranked as the most important for suggesting JME. Conclusion: Radiomic models using MRI were able to differentiate JME from HCs.

Regional Amyloid Burden Differences Evaluated Using Quantitative Cardiac MRI in Patients with Cardiac Amyloidosis

  • Jin Young Kim;Yoo Jin Hong;Kyunghwa Han;Hye-Jeong Lee;Jin Hur;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.880-889
    • /
    • 2021
  • Objective: This study aimed to investigate the regional amyloid burden and myocardial deformation using T1 mapping and strain values in patients with cardiac amyloidosis (CA) according to late gadolinium enhancement (LGE) patterns. Materials and Methods: Forty patients with CA were divided into 2 groups per LGE pattern, and 15 healthy subjects were enrolled. Global and regional native T1 and T2 mapping, extracellular volume (ECV), and cardiac magnetic resonance (CMR)-feature tracking strain values were compared in an intergroup and interregional manner. Results: Of the patients with CA, 32 had diffuse global LGE (group 2), and 8 had focal patchy or no LGE (group 1). Global native T1, T2, and ECV were significantly higher in groups 1 and 2 than in the control group (native T1: 1384.4 ms vs. 1466.8 ms vs. 1230.5 ms; T2: 53.8 ms vs. 54.2 ms vs. 48.9 ms; and ECV: 36.9% vs. 51.4% vs. 26.0%, respectively; all, p < 0.001). Basal ECV (53.7%) was significantly higher than the mid and apical ECVs (50.1% and 50.0%, respectively; p < 0.001) in group 2. Basal and mid peak radial strains (PRSs) and peak circumferential strains (PCSs) were significantly lower than the apical PRS and PCS, respectively (PRS, 15.6% vs. 16.7% vs. 26.9%; and PCS, -9.7% vs. -10.9% vs. -15.0%; all, p < 0.001). Basal ECV and basal strain (2-dimensional PRS) in group 2 showed a significant negative correlation (r = -0.623, p < 0.001). Group 1 showed no regional ECV differences (basal, 37.0%; mid, 35.9%; and apical, 38.3%; p = 0.184). Conclusion: Quantitative T1 mapping parameters such as native T1 and ECV may help diagnose early CA. ECV, in particular, can reflect regional differences in the amyloid deposition in patients with advanced CA, and increased basal ECV is related to decreased basal strain. Therefore, quantitative CMR parameters may help diagnose CA and determine its severity in patients with or without LGE.

Evaluation of the Ostium in Anomalous Origin of the Right Coronary Artery with an Interarterial Course Using Dynamic Cardiac CT and Implications of Ostial Findings

  • Jin-Young Kim;Yoo Jin Hong;Kyunghwa Han;Suji Lee;Young Jin Kim;Byoung Wook Choi;Hye-Jeong Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.172-179
    • /
    • 2022
  • Objective: We aimed to evaluate the ostium of right coronary artery of anomalous origin from the left coronary sinus (AORL) with an interarterial course throughout the cardiac cycle on CT and analyze the clinical significance of the ostial findings. Materials and Methods: From January 2011 to December 2015, 68 patients (41 male, 57.3 ± 12.1 years) with AORL with an interarterial course and retrospective cardiac CT data were included. AORL was classified as high or low ostial location based on the pulmonary annulus in the diastolic and systolic phases on cardiac CT. In addition, the height, width, height/width ratio, area, and angle of the ostium were measured in both cardiac phases. After cardiac CT, patients were followed until December 31, 2020 for major adverse cardiac events (MACE). Clinical and CT characteristics associated with MACE were explored using Cox regression analysis. Results: During a median follow-up period of 2071 days (interquartile range, 1180.5-2747.3 days), 13 patients experienced MACE (19.1%, 13/68). Seven (10.3%, 7/68) had the ostial location change from high in the diastolic phase to low in the systolic phase. In the univariable analysis, younger age (hazard ratio [HR] = 0.918, p < 0.001), high ostial location (HR = 4.008, p = 0.036), larger height/width ratio (HR = 5.621, p = 0.049), and smaller ostial angle (HR = 0.846, p = 0.048) in the systolic phase were significant predictors of MACE. In multivariable cox regression analysis, younger age (adjusted HR = 0.917, p = 0.002) and high ostial location in the systolic phase (adjusted HR = 4.345, p = 0.026) were independent predictors of MACE. Conclusion: The ostial location of AORL with an interarterial course can change during the cardiac cycle, and high ostial location in the systolic phase was an independent predictor of MACE.

Assessment of infection control in oral radiology during the COVID-19 outbreak: An international collaborative study

  • Rafaela C Santos;Larissa S Araujo;Rafael B Junqueira;Eliana D Costa;Fernanda M Pigatti;Kivanc Kamburoglu;Pedro HB Carvalho;Manuela LB Oliveira;Sibele N Aquino;Francielle S Verner
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.365-373
    • /
    • 2023
  • Purpose: In the context of COVID-19, studies evaluating the adherence of dentists and dental students to infection control are relevant due to their high occupational exposure and risk, as well as their responsibility for disseminating information and good practices. This study evaluated the adherence of dentists and dental students to infection control in the oral radiology field in the setting of the COVID-19 pandemic on different continents. Materials and Methods: This cross-sectional observational study involved individuals who performed intraoral radiographic examinations during the COVID-19 pandemic. The Questionnaire on Infection Control in Oral Radiology was administered virtually using a Google Form. Participants from different continents(the Americas, Africa, Europe, Asia, and Oceania) were recruited. Data were subjected to descriptive analysis and simple and multiple binary regression (5%). Results: There were 582 valid answers, and 68.73% of the participants were from the Americas, 18.90% from Europe, and 12.37% from Asia. The median score for infection control protocols was 94 points for dental students and 104 points for dentists, and participants below the median were considered to have low adherence to infection control in oral radiology. Low access to infection control was found for 53.0% of dentists in the Americas, 34.0% from Europe, and 26.9% from Asia. Conclusion: The adherence to infection control protocols in oral radiology was low even in the face of the COVID-19 pandemic. The results may help improve the awareness of students and professionals, since oral radiology routines have the potential for transmitting COVID-19.