• 제목/요약/키워드: Radiological risk

검색결과 398건 처리시간 0.029초

척추 신경 차단술 환자 특성이 주사시술의 공포감과 방사선의 위험 인식에 미치는 영향 (Effect on Fear of Injection Procedures and Radiation Risk Recognition on Patients Characteristics Undergo Spinal Nerve Block)

  • 차진영;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.171-177
    • /
    • 2022
  • The purpose of this study was to investigate the effect of the characteristics of patients who underwent spinal nerve block on the fear of injection and the risk of radiation. Subjects were 137 patients (67 males, 70 females) who visited the Department of Anesthesiology and Pain Medicine in Cheongju. The method was conducted as a research study using a total of 28 questionnaires consisting of patient characteristics, experience characteristics of nerve block surgery, nerve block fear scale, and radiation risk perception scale. The reliability of the questionnaire response was secured with a Cronbach's alpha coefficient of 0.6 or higher. For statistical analysis, correlation was tested by descriptive statistics, frequency analysis, independent sample T-test, and Pearson and Spearman correlation coefficients by measurement scale and factor. As a result, the fear scale of nerve block was significantly higher in women than in men (p<0.05). The fear scale of nerve block injection was significantly higher in the first-visit patients than in the second-visited patients (p<0.05). However, there was no significant difference among all variables in radiation risk perception. In conclusion, patients undergoing spinal nerve block were more aware of the fear of injection than the risk of radiation exposure during the procedure.

방사선이용과 공공안전 (An Study on Radiation Application and Public Safety)

  • 류재수;양맹호
    • 한국기술혁신학회:학술대회논문집
    • /
    • 한국기술혁신학회 2003년도 추계학술대회
    • /
    • pp.369-386
    • /
    • 2003
  • Radiation technologies are being utilized in a wide range of daily modern life and provide the public with valuable benefits through applications in fields of medical, industrial, agricultural, and science & engineering research. On the other hand, there is a high possibility that radioactive materials can be used for malevolent purposes such as dirty bombs. The International community, therefore, has made efforts to improve the security of radioactive sources aimed at protecting the public from radiological terrorism. The paper investigated high-risk radioactive sources which could be used as dirty bombs. The paper reviewed the possibility of radiological weapon attacks and analyzed international trends to enhance security of radioactive sources. This study also proposed our countermeasures to reduce the threat of radiological terrorism and to properly respond to the radiological emergency caused by the radiological weapon attack.

  • PDF

Impact of Time Interval between Index Event and Stenting on Periprocedural Risk in Patients with Symptomatic Carotid Stenosis

  • Han, Wonsuck;Hwang, Gyojun;Oh, Sung Han;Lee, Jong Joo;Kim, Mi Kyung;Chung, Bong Sub;Rhim, Jong Kook;Sheen, Seung Hun;Kim, Taehyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권5호
    • /
    • pp.598-606
    • /
    • 2020
  • Objective : The purpose of this study was to evaluate the impact of time interval between index event and stenting on the periprocedural risk of stenting for symptomatic carotid stenosis and to determine the optimal timing of stenting. Methods : This retrospective study included 491 (322 symptomatic [65.6%] and 169 asymptomatic [34.4%]) patients undergoing carotid stenting. The symptomatic patients were categorized into Day 0-3, 4-7, 8-10, 11-14, 15-21, and >21 groups according to the time interval between index event and stenting. Periprocedural (≤30 days) risk for clinical (any neurological deterioration) and radiological (new infarction on postprocedural diffusion-weighted imaging) events of stenting in each time interval versus asymptomatic stenosis was calculated with logistic regression analysis adjusted for confounders, and provided as odds ratio (OR) and 95% confidence interval (CI). Results : Overall clinical event rate (4.3%) of stenting for symptomatic carotid stenosis was higher than that for asymptomatic stenosis (1.2%; OR, 3.979 [95% CI, 1.093-14.489]; p=0.036). Stenting in Day 0-3 (13.2%; OR, 10.997 [95% CI, 2.333-51.826]; p=0.002) and Day 4-7 (8.3%; OR, 6.775 [95% CI, 1.382-33.227]; p=0.018) was associated with high risk for clinical events. However, the clinical event rates in stenting after 7 days from index event (Day 8-10, 1.8%; Day 11-14, 2.5%; Day 15-21, 0%; Day >21, 2.9%) were not different from that in stenting for asymptomatic stenosis. Overall radiological event rate (55.6%) in symptomatic stenosis was also higher than that in asymptomatic stenosis (35.5%; OR, 2.274 [95% CI, 1.553-3.352]; p<0.001). The high risk for radiological events was maintained in all time intervals (Day 0-3 : 55.3%; OR, 2.224 [95% CI, 1.103-4.627]; p=0.026; Day 4-7 : 58.3%; OR, 2.543 [95% CI, 1.329-4.949]; p=0.005; Day 8-10 : 53.6%; OR, 2.096 [95% CI, 1.138-3.889]; p=0.018; Day 11-14 : 57.5%; OR, 2.458 [95% CI, 1.225-5.021]; p=0.012; Day 15-21 : 55.6%; OR, 2.271 [95% CI, 1.099-4.764]; p=0.028; Day >21 : 54.8%; OR, 2.203 [95% CI, 1.342-3.641]; p=0.002). Conclusion : This study showed that as stenting was delayed, the periprocedural risk for clinical events decreased. The clinical event risk was high only in stenting within 7 days and comparable with that for asymptomatic stenosis in stenting after 7 days from index event, although the radiological event risk was not affected by stenting timing. Therefore, our results suggest that delayed stenting after 7 days from symptom onset is a safe strategy for symptomatic stenosis.

전산화단층촬영검사와 일반촬영검사의 방사선 선량에 대한 인식도 조사 (The Survey for Awareness of Radiation Dose of CT and General X-ray Examination)

  • 주영철;임청환;정홍량;유인규;조한별;양오남;김민철;윤준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권1호
    • /
    • pp.35-44
    • /
    • 2012
  • 서울소재 'S'병원에서 근무중인 방사선사를 대상으로 병원 근무경력 및 CT검사실 근무 경험 유 무, 현재 사용하고 있는 방사선 선원의 종류에 따른 CT검사와 일반촬영검사의 방사선 선량과 위험성에 관한 인식도 조사를 통해 CT검사의 위험성에 대한 각성을 위한 기초자료로 활용하고자 한다. 영상의학과에 근무하는 방사선사 중 131명을 대상으로 설문지를 통해 연구가설 검정을 위한 자료를 수집하였고, 설문문항의 Cronbach @계수는0.825988과0.767161로 나타났으며, p-value의 기각률은<0.05로 하였다. 연구가설검정을 위해 SAS 9.1(SAS Institute Inc., Cary, NC, USA.)통계패키지를 이용하여 Mann-Whitney test와 Kruskai-Wallis test, Two sample T-test, Two sample T-test with Bonferroni's Correction, One-way ANOVA 통계분석방법 등을 이용하였다. CT검사와 일반촬영의 선량에 관한 가설의 각 p-value 값은 0.2291~0.9663의 범위로 나타났고, CT검사와 일반촬영검사의 위험성에 관한 가설의 각 p-value 값은 0.1924~1.0000의 범위로 나타났다. 모든 연구가설의 p-value값이 기각률(<0.05)을 상위하여 나타났으며, 현재 'S'병원에 근무중인 방사선사들은 근무경력 및 CT검사실 근무경력 유무, 현재 사용하는 방사선 선원의 종류에 관계없이 일반촬영 보다 CT검사가 선량이 많으며, 위험하다고 인식하고 있는 것으로 나타났다.

이중에너지 X선 흡수계측법을 이용한 대퇴골 근위부의 형태학적 측정에 따른 골절 위험도의 예측 (Predict of Fracture Risk Rate According to Morphological Measuring of Proximal Femoral Part Using Dual Energy X-ray Absoptiometry)

  • 윤한식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권1호
    • /
    • pp.49-53
    • /
    • 2002
  • The femoral fracture is the most serious problem of old ages haying osteoporotic fractures. First of all, prevention to reduce the incidence of hip fracture and to identify the risk factor is essential subject. The purpose of this study is to investigate which geometric parameters of proximal femur are related to the hip fracture risk in old ages. Author analyzed the bone density and bone content of over 60 years old women who had suffered hip fracture (n=60) and non fracture groups (n=60). Author concluded that geometric measurements of proximal femoral part made on dual energy x-ray absorptiometry can predict hip fracture independently of bone mineral density.

  • PDF

부산·경남 지역 성인의 담낭용종 위험인자 및 초음파 영상의 형태학적 분석 (Analysis of Risk factors & Morphological Ultrasound Image for Gallbladder Polyp in Adults Living in Busan and Gyeongnam Provinces)

  • 안현;황철환;고성진;김창수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.353-359
    • /
    • 2016
  • 본 연구는 부산 경남지역에서 담낭용종의 위험인자 및 초음파영상의 형태학적 분포를 알아보고자 하였다. 실험 대상은 2016년 1월~5월까지 부산 P병원 내원환자의 복부초음파 영상을 대상으로 하였다. 그 중 복부초음파와 혈청학적 검사를 동시에 실시한 399명을 대상으로 위험인자를 분석하였다. 담낭용종 위험인자들의 통계분석은 독립표본 t검정(independent t-test)과 카이제곱 검정(chi-square test)을 시행하였다. 차이검정 결과를 고려하여 독립변수에 대한 상대 위험비(odds ratio, OR) 산출을 위해 다중 로지스틱 회귀분석(multiple logistic regression analysis)을 시행하여 변수들로부터 예측모형을 산정하여 타당성을 검정하였다. 그 결과 담낭용종 위험인자로 남성, HBsAg 양성, 중성지방이 관련이 있음을 알 수 있었다. 담낭용종의 위험인자로 확인된 남성, HBsAg 양성, 중성지방으로 예측모형 및 예측 확률값을 산정하였다. 예측확률의 민감도 61.0%, 특이도 76.8%를 보였으며, ROC 곡선의 AUC 결과는 0.735를 보여 예측모형의 타당성을 확인할 수 있었다. 복부 초음파검사 상 관찰되는 담낭용종의 형태학적 분석 결과는 고 에코, 유경, 균질한 형태가 가장 많은 분포(27.5%)를 나타내었으며, 용종 개수는 2개(38%), 크기는 5~10 mm (53%)로 가장 많았다. 담낭용종과 관련된 간질환으로는 mild fatty liver (23%), diffuse hepatopathy (21%)로 나타났다.

Assessment of Radiological Hazards in Some Foods Products Consumed by the Malian Population Using Gamma Spectrometry

  • Adama Coulibaly;David O. Kpeglo;Emmanuel O. Darko
    • Journal of Radiation Protection and Research
    • /
    • 제48권2호
    • /
    • pp.84-89
    • /
    • 2023
  • Background: Food consumption is one of the most important routes for radionuclide intake for the public; therefore, there is the need to have a comprehensive understanding of the amount of radioactivity in food products. Consumption of radionuclide-contaminated food could increase potential health risks associated with exposure to radiation such as cancers. The present study aims to determine radioactivity levels in some food products (milk, rice, sugar, and wheat flour) consumed in Mali and to evaluate the radiological effect on the public health from these radionuclides. Materials and Methods: The health impact due to ingestion of radionuclides from these foods was evaluated by the determination of activity concentration of radionuclides 238U, 232Th, 40K, and 137Cs using gamma spectrometry system with high-purity germanium detector and radiological hazards index in 16 samples collected in some markets, mall, and shops of Bamako-Mali. Results and Discussion: The average activity concentrations were 9.8±0.6 Bq/kg for 238U, 8.7±0.5 Bq/kg for 232Th, 162.9±7.9 Bq/kg for 40K, and 0.0035±0.0005 Bq/kg for 137Cs. The mean values of radiological hazard parameters such as annual committed effective dose, internal hazard index, and risk assessment from this work were within the dose criteria limits given by international organizations (International Commission on Radiological Protection and United Nations Scientific Committee on the Effects of Atomic Radiation) and national standards. Conclusion: The results show low public exposure to radioactivity and associated radiological impact on public health. Nevertheless, this study stipulates vital data for future research and regulatory authorities in Mali.

심장외막지방두께와 당뇨와의 연관성 연구 (The Relationship Between Epicardial Adipose Tissue and Diabetes Mellitus)

  • 김선화;김정훈;임인철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.305-312
    • /
    • 2018
  • The incidence of cardiovascular disease increases rapidly after 40's. The thickness of the epicardial adipose tissue was measured to analyze the risk factors affecting the thickness change. We present the cut off value for the epicardial adipose tissue thickness for high impacted variables. For the study, 547 patients underwent echocardiography, epicardial adipose tissue thickness, body mass index, abdominal subcutaneous fat thickness and diabetes mellitus were used as analytical variables. As a result, multiple regression analysis of age group showed that diabetes mellitus was highly influential in all age group, so we could predict the cut off value for the epicardial adipose tissue thickness for diabetes mellitus. As a result of ROC curve analysis, cut off value of 7.44 mm was obtained with sensitivity of 79.6% and specificity of 60.6% for diab etes variab le. Logistic regression analysis b ased on this value showed that the risk for diab etes increased 6 times with each increase in the thickness of the epicardial adipose tissue. Among the various obesity indexes, epicardial adipose tissue is used as an important index especially to prevent the risk of cardiovascular disease. Therefore, we suggest that the use of echocardiography as a routine screening method for the prevention of cardiovascular disease and metabolic syndrome, which is rapidly increasing in patients over 40's age, will enable more effective monitoring. Radiation is the emission or transmission of energy in the form of waves or particles through space or through a material medium.

Single Particle Irradiation System to Cell (SPICE) at NIRS

  • Yamaguchi, Hiroshi;Ssto, Yukio;Imaseki, Hitoshi;Yasuda, Nakahiro;Hamano, Tsuyoshi;Furusawa, Yoshiya;Suzuki, Masao;Ishikawa, Takehiro;Mori, Teiji;Matsumoto, Kenichi;Konishi, Teruaki;Yukawa, Masae;Soga, Fuminori
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.267-268
    • /
    • 2002
  • Microbeam is a new avenue of radiation research especially in radiation biology and radiation protection. Selective irradiation of an ionizing particle to a targeted cell organelle may disclose such mechanisms as signal transaction among cell organelles and cell-to-cell communication in the processes toward an endpoint observed. Bystander effect, existence of which is clearly evidenced by application of the particle microbeam to biological experiments, suggests potential underestimation in the conventional risk estimation at low particle fluence rates, such as environment of space radiations in ISS (International Space Station). To promote these studies we started the construction of our microbeam facility (named as SPICE) to our HVEE Tandem accelerator (3.4 MeV proton and 5.1 MeV $^4$He$\^$2+/). For our primary goal, "irradiation of single particle to cell organelle within a position resolution of 2 micrometer in a reasonable irradiation time", special features are considered. Usage of a triplet Q magnet for focussing the beam to submicron of size is an outstanding feature compared to facilities of other institutes. Followings are other features: precise position control of cell dish holder, design of the cell dish, data acquisition of microscopic image of a cell organelle (cell nucleus) and data processing, a reliable particle detection, soft and hard wares to integrate all these related data, to control and irradiate exactly determined number of particles to a targeted spot.

  • PDF