• Title/Summary/Keyword: Radiological data

Search Result 1,111, Processing Time 0.027 seconds

The Performance of Heavy Ion CT System with Fluorescent Screen and CCD Camera

  • Tomida, Tetsuya;Nishimura, Katsuyuki;Abe, Shinji;Sato, Hitoshi;Muraishi, Hiroshi;Inada, Tetsuo;Tazawa, Shuichi;Kanai, Tatsuaki;Yusa, Ken;Kawachi, Kiyomitsu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.432-435
    • /
    • 2002
  • We have developed and proposed the heavy ion CT system which consists of fluorescent screen and CCD camera equipped with image intensifier. In our system, we have measured the residual range of particles that passed a phantom and reconstructed the CT image for the distribution of relative stopping power by filtered back projection method with Shepp '||'&'||' Logan filter. The heavy ion $\^$12/C accelerated up to 400 MeV/u by HIMAC (Heavy Ion Medical Accelerator in Chiba) was used. Intensity of the beam output changes like macro pulse, the period being 3.3 sec and the width being 2 sec. The series of data was acquired in synchronizing with the pulse, leading to the improvement of S/N in the CT image. The fundamental performance was experimentally evaluated in the proposed system. The spatial resolution was estimated to be about 1 mm and the density resolution (electron density referred to water) to be about 0.01.

  • PDF

SIRT1 Suppresses Activating Transcription Factor 4 (ATF4) Expression in Response to Proteasome Inhibition

  • Woo, Seon Rang;Park, Jeong-Eun;Kim, Yang Hyun;Ju, Yeun-Jin;Shin, Hyun-Jin;Joo, Hyun-Yoo;Park, Eun-Ran;Hong, Sung Hee;Park, Gil Hong;Lee, Kee-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.12
    • /
    • pp.1785-1790
    • /
    • 2013
  • The synthetic machinery of ATF4 (activating transcription factor 4) is activated in response to various stress conditions involved in nutrient restriction, endoplasmic reticulum homeostasis, and oxidation. Stress-induced inhibition of proteasome activity triggers the unfolded protein response and endoplasmic reticulum stress, where ATF4 is crucial for consequent biological events. In the current study, we showed that the $NAD^+$-dependent deacetylase, SIRT1, suppresses ATF4 synthesis during proteasome inhibition. SIRT1 depletion via transfection of specific siRNA into HeLa cells resulted in a significant increase in ATF4 protein, which was observed specifically in the presence of the proteasome inhibitor MG132. Consistent with SIRT1 depletion data, transient transfection of cells with SIRT1-overexpressing plasmid induced a decrease in the ATF4 protein level in the presence of MG132. Interestingly, however, ATF4 mRNA was not affected by SIRT1, even in the presence of MG132, indicating that SIRT1-induced suppression of ATF4 synthesis occurs under post-transcriptional control. Accordingly, we propose that SIRT1 serves as a negative regulator of ATF4 protein synthesis at the post-transcriptional level, which is observed during stress conditions, such as proteasome inhibition.

Intracerebral Hemorrhage Auto Recognition in Computed Tomography Images (CT 영상에서 뇌출혈의 자동인식)

  • Choi, Seok-Yoon;Kang, Se-Sik;Kim, Chang-Soo;Kim, Jung-Hoon;Kim, Dong-Hyun;Ye, Soo-Young;Ko, Seong-Jin
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.141-148
    • /
    • 2013
  • The CT examination sometimes fail to localize the cerebral hemorrhage part depending on the seriousness and may embarrass the pathologist if he/she is not trained enough for emergencies. Therefore, an assisting role is necessary for examination, automatic and quick detection of the cerebral hemorrhage part, and supply of the quantitative information in emergencies. the computer based automatic detection and recognition system may be of a great service to the bleeding part detection. As a result of this research, we succeeded not only in automatic detection of the cerebral hemorrhage part by grafting threshold value handling, morphological operation, and roundness calculation onto the bleeding part but also in development of the PCA based classifier to screen any wrong choice in the detection candidate group. We think if we apply the new developed system to the cerebral hemorrhage patient in his critical condition, it will be very valuable data to the medical team for operation planning.

Research on the Actual Condition of Working Conditions in the Small and Medium Clinics (중소 병.의원 근무환경 실태조사)

  • Cheol, Kweon-Dae;Mi, Jang-Myeong;Hei, Jang-Yun;Mo, Chung-Kyung;Sin, Kwak-Choong
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.55-65
    • /
    • 2005
  • Research of actual condition of working conditions in the small and clinics, in the Seoul metropolitan city and Kyeonggido province. With the health care environmental change such as a rapid increase of the elderly people, rapid increase of health promotion needs, it is necessary to analyse and identity of the actual condition of working conditions for present and new radiological technologist. Research of general characteristics for the present radiological technologist. To research of the status employment, business scope, pay, working conditions, radiation safety management, equipment, and category association. Defining the problems of related working conditions, radiation safety management for the comprehensive methods to promote the rights the radiological technologist. A proposal for establishment legislature and system of the actual condition in the hospital for radiological technologist. Estimation for the demand and supply numbers of present radiological technologist and improvement of employment relations. Improved and refined scope business and duty regulation related to radiological technologist. Application for the establishment and development of promotion rights to utilize as basic data in a legislative and system frame of reference to implement the radiological technologist.

  • PDF

Optimization of Data Acquisition System with Parallel Collection for PET

  • Yoshida, Eiji;Shimizu, Keiji;Murayama, Hideo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.311-313
    • /
    • 2002
  • We are under development of a 3D PET scanner with depth of interaction (DOI) capable of high sensitivity and high resolution. In this scanner, a maximum data transfer rate of coincidence pair's event information is 10 Mcps and one event is a 64-bit data format. This maximum data transfer rate corresponds by 10 times a conventional PET scanner. A data acquisition system, which fulfills the specification of this scanner, is considered for parallel collection with banks including several coincidence units. Data transfer rate is improved by optimizing parameters of a message size, and so on.

  • PDF

A Study on the Radioactive Products of Components in Proton Accelerator on Short Term Usage Using Computed Simulation (몬테칼로 시뮬레이션을 활용한 양성자가속기 단기사용 시 구성품의 방사화 평가)

  • Bae, Sang-Il;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.389-395
    • /
    • 2020
  • The evaluation of radioactivated components of heavy-ion accelerator facilities affects the safety of radiation management and the exposure dose for workers. and this is an important issue when predicting the disposal cost of waste during maintenance and dismantling of accelerator facilities. In this study, the FLUKA code was used to simulate the proton treatment device nozzle and classify the radio-nuclides and total radioactivity generated by each component over a short period of time. The source term was evaluated using NIST reference beam data, and the neutron flux generated for each component was calculated using the evaluated beam data. Radioactive isotopes caused by generated neutrons were compared and evaluated using nuclide information from the International Radiation Protection Association and the Korea Radioisotope association. Most of the nuclides produced form of beta rays and electron capture, and short-lived nuclides dominated. However, In the case of 54Mn, which is a radioactive product of iron, the effect of gamma rays should be considered. In the case of tritium generated from a material with a low atomic number, it is considered that handling care should be taken due to its long half-life.

Maximum TE Setting Range for Quantitatively Evaluating T2 Relaxation Time : Phantom Study (T2 이완시간의 정량적 평가에 있어서 Maximum TE의 설정 범위에 대한 연구 : 팬텀연구)

  • Park, Jin Seo;Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.25-31
    • /
    • 2018
  • This study aimed to evaluate the range of maximum TE that could measure T2 relaxation time accurately by setting diverse maximum TE with using contrast medium phantoms. Contrast medium phantoms ranging from low to high concentrations were made by using Gadoteridol. The relaxation time and relaxation rate were compared and evaluated by conducting T2 mapping by using reference data based on various TEs and data obtained from different maximum TEs. It was found that accurate T2 relaxation time could be expressed only when the maximum TE over a certain range was used in the section with long T2 relaxation time, such as the low concentration section of saline or gadolinium contrast medium. Therefore, the maximum TE shall be longer than the T2 relation time for accurately maturing the T2 relaxation of a certain tissue or a substance.

The clinical utilization of radiation therapy in Korea between 2009 and 2013

  • Kang, Jin-Kyu;Kim, Mi-Sook;Jang, Won-Il;Seo, Young Seok;Kim, Hee Jin;Cho, Chul Koo;Yoo, Hyung Jun;Paik, Eun Kyung;Cha, Yu Jin;Song, Hyun Jin
    • Radiation Oncology Journal
    • /
    • v.34 no.2
    • /
    • pp.88-95
    • /
    • 2016
  • Purpose: The purpose of this study was to estimate the clinical utilization of radiation therapy (RT) in Korea between 2009 and 2013. Materials and Methods: We analyzed open claims data from the Health Insurance Review and Assessment Service. The subjects were patients who had diagnostic codes C00-C97 or D00-D48 according to the 10th revision of the International Classification of Diseases, with procedure codes indicating RT treatment. Results: The total number of patients who received RT in 2009, 2010, 2011, 2012, and 2013 were 45,571, 49,593, 54,671, 59,172, and 61,485, respectively. Among them, the total numbers of male and female patients were 20,780/24,791 in 2009, 22,711/26,882 in 2010, 24,872/29,799 in 2011, 27,101/32,071 in 2012, and 27,941/33,544 in 2013. The five cancers that were most frequently treated with RT between 2009 and 2012 were breast, lung, colorectal, liver, and uterine cervical cancers. However, the fifth most common cancer treated with RT that replaced uterine cervical cancer in 2013 was prostate cancer. The three leading types of cancer among the male patients were lung, colorectal, and liver cancers, whereas in female patients, they were breast, uterine cervical, and lung cancers. The type of cancer most commonly treated by RT was cancer of the central nervous system in patients aged 20 years or less, breast cancer in patients aged 30-50 years, and lung cancer in patients aged 60 years or more. Conclusion: Data from this study provided the clinical utilization of RT in Korea between 2009 and 2013.

Profile and Dose Distribution for Therapeutic Heavy Ion Beams

  • Sasaki, Hitomi;Komori, Masataka;Kohno, Toshiyuki;Kanai, Tatsuaki;Hirai, Masaaki;Urakabe, Eriko;Nishio, Teiji
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.211-213
    • /
    • 2002
  • The purpose of this work is acquiring some parameters of therapeutic heavy ion beams after penetrating a thick target. The experiments were performed using a pencil-like $\^$12/C beam of about 3 mm in diameter from NIRS-HIMAC, and the data were taken at several points of the target thickness for $\^$12/C beam of 290 MeV/u and 400 MeV/u. By the simultaneous measurements using some detectors, the atomic number of each fragment particle was identified, and the beam profile, the dose distribution and the LET spectrum for each element were derived.

  • PDF

Evaluation of Breast Dose by Breast Pressure Thickness of Breast Prosthesis Insertion (보형물 삽입 유방의 압박 두께에 따른 유방 선량 평가)

  • Lee, Hyeon-Yong;Kim, Ji-Soo
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.469-473
    • /
    • 2020
  • Breast cancer is growing rapidly year by year and has the highest incidence since 2001. As a result, the interest in mammography for early detection of breast cancer is increasing. However, mammography is accompanied by radiation exposure and therefore it is necessary to reduce exposure dose through appropriate test conditions. The significance of this study is that breast dose studies, which were limited to ordinary women, were applied to breast implant patient. Using MCNP simulation, the phantom with prosthesis inserted was developed to compare dose by tube voltage by pressure thickness. In addition phantom without prostheses has higher dose than phantom with prostheses. If these results were used as basic data, it would be possible to recommend test condition guideline only for breast implant patients.