• Title/Summary/Keyword: Radiological data

Search Result 1,111, Processing Time 0.047 seconds

Differences in Patients' and Family Caregivers' Ratings of Cancer Pain (암환자와 그 가족간호자가 지각하는 환자의 통증강도 차이)

  • Kim, Hyun-Sook;Yu, Su-Jeong;Kwon, Shin-Young;Park, Yeon-Hee
    • Journal of Hospice and Palliative Care
    • /
    • v.11 no.1
    • /
    • pp.42-50
    • /
    • 2008
  • Purpose: Undertreatment of canter pain, especially due to the differences in the perception of pain between the patients and caregivers, is a well recognized problem. The purpose of this study were to determine if there exist differences in communication about pain intensity scores between patients and their family caregivers in Korea. Methods: A total of 127 patient-family caregiver dyads who have experienced canter pain participated in this study at a hospital in Seoul for six months. The data were obtained by fare to face interview with a structured questionnaire based on Brief Pain Inventory-Korean version and other previous researches. The clinical information for all patients was compiled by reviewing their medical records. Results: Patients' 'worst-pain for 24-hour' and 'right-now-pain' scores estimated by family caregivers were significantly higher than those by patient themselves. The degree of agreement between patients and family caregivers in the estimate of patients' 'worst-pain for 24-hour' intensity categories was 78.7% for 'severe pain', 40% for 'no pain', 27.5% for 'mild pain' and 22.9% for 'moderate pain'. In case of 'right-now-pain' intensity categories, the agreement was 50% for 'severe pain', 47.2% for mild pain, 46.3% for 'no pain', and 26.3% for 'moderate pain'. Conclusion: This study demonstrates that the degree of agreement between patients and family caregivers in the estimate of patients 'pain intensity categories was less than 50% except for 'severe pain'. The results indicate that Korean family caregivers tend to overestimate the canter pain intensity of their caring patients, especially, when a lancer patient has 'moderate' or 'mild pain'. Health Providers are advised to educate patient-family caregiver dyads to use a pain measurement scale to promote their agreement in pain Intensity stores. Further analyses and studies are needed to identify the factors and differences that influence their communication about pain intensity scores between patients and their family caregivers.

  • PDF

A clinical study on the etiology of parapneumonic effusion in children (소아 감염성 흉막삼출의 원인 분석)

  • Yeom, Jung-Sook;Bae, Won-Tae;Park, Eun-Sil;Seo, Ji-Hyun;Lim, Jae-Young;Park, Chan-Hoo;Woo, Hyang-Ok;Youn, Hee-Shang
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.1
    • /
    • pp.56-63
    • /
    • 2006
  • Purpose : This study was designed to document the etiologies and the characteristics of parapneumonic effusion in children. Methods : During a 17-year period from 1987 to 2004, parapneumonic effusion was confirmed in 86 children at Gyeongsang National University Hospital. The clinical records of these children were reviewed and radiological findings and laboratory data, especially results of thoracentesis, were analyzed retrospectively. Results : M. pneumoniae(34 subjects) was the most common pathogen at all over age, especially above 1-years-old. There were diagnosed with clinical characteristics and serologic tests. The $2^{nd}$ most common pathogen revealed non tuberculous bacteria(14 subjects). A species of bacteria at no tuberculous bacteria revealed S. aureus(5), S. pneumoniae(3), P. aeroginosa(3), other staphylococcus (2), and K. pneumoniae(1). There were confirmed with sputum culture or pleural fluid culture or blood culture. S. aureus was most common pathogen in infants. The $3^{rd}$ common pathogen was M. tuberculosis(7). There were confirmed with skin tuberculin tests and AFB stains. Another that was classified as a non bacteria was adenovirus(2). Complications of parapneumonic effusion such as pleural thickness occurred on M. tuberculosis(1). Non tuberculous bacteria, especially S. aureus revealed a serious predominance of polymorphocyte at pleural fluid, and lowest pleural pH and glucose, and highest pleural protein and LDH. Tuberculosis revealed high pleural protein and LDH. Conclusion : Age and chemistries of pleural fluid might be helpful in differentiating various etiologies of parapneumonic effusion. If there were suspicious of tuberculosis and non-tuberculous bacteria, more aggressive approaches were needed to prevent complication.

Effect of surfactant lavage in severe meconium aspiration syndrome (중증 태변 흡인 증후군에서 인공 폐표면활성제 세정요법의 효과에 관한 비교 연구)

  • Lee, Soon Min;Kim, He Min;Jeon, Ji Hyun;Park, Min Soo;Park, Kook In;Namgung, Ran;Lee, Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.367-371
    • /
    • 2008
  • Purpose : The surfactant dysfunction may play an important role in meconium aspiration syndrome (MAS). We aim to evaluate the effect of surfactant lavage in the treatment of term infants with MAS. Methods : The medical records of 15 neonates with severe MAS admitted at Yongdong Severance Hospital from 2005 to 2007 were reviewed and analyzed. Seven infants with severe MAS necessitating mechanical ventilation underwent tracheobronchial lavage with 20 mL/kg of diluted (5.3 mg phospholipid/mL) surfactant saline suspension ($Newfactan^{(R)}$). Data regarding clinical outcomes was assessed by comparison with 8 control infants with equally severe MAS retrospectively. Results : In the lavage group, radiological improvement was evident after 6 hours of treatment. The duration of artificial ventilation and duration of hospital day were also significantly shorten in the lavage group compared with the control group. The mean oxygen index, mean ventilation index improved significantly within the first 6 hours after treatment. No differences were found in the incidence of major complications and mortality between the two groups. Conclusion : The surfactant lavage seems to be an effective and safe method for treatment of severe MAS. A multicenter, large scaled randomized controlled trial is needed for further study.

Signal Change of Iodinated Contrast Agents in MR Imaging (요오드화 조영제가 MR영상에 미치는 신호 변화)

  • Jeong, HK;Kim, Seongho;Kang, Chunghwan;Lee, Suho;Yi, Yun;Kim, Mingi;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.131-138
    • /
    • 2016
  • In this study, we tried to analyze the influence of ICM(Iodinated Contrast Media) in MR imaging compare to GBCA(Gadolinium Based Contrast Agent), and as this result we discussed whether resonable or not the protocol which is MRI scan after enhanced CT scan without proper time interval in clinical field. For this research, we assembled two phantoms. which one was iodine and another one was gadolinium. We did test two phantoms in conventional MRI scan which is T1, T2, T2 FLAIR and 3D angio. After that, quantitative analysis was progressed. The results of study were as follow : SSI(Saline's Signal Intensity) was shown as each sequences 175, 1231, 333, 37 [a.u] at iodine. and 1297, 123, 757, 232 [a.u] was recorded at gadolinium. BDEPS(the Biggest Difference of EPS) was shown as each sequences 1297, 123, 757, 232 [a.u] at iodine and 793, 6, 1495, 365 [a.u] was recorded at gadolinium. At this time, EPS(Enhancement Percentage to Saline) was shown 641.1, -90.0, 127.3, 527% at iodine and 685.1, 99.4, 365.7, 1077.4% was recorded at gadolinium. BP(BDEPS's point) was shown 900, 900, 477, 900 mmol at iodine and 4, 0.2, 0.2, 40 mmol was recorded at gadolinium. CPSS(Change Point of SI to SSI) was shown 63, 423, 63, 29 mmol at iodine and each [50, 30], [4, 0.2], [4, 1], 0.2 mmol was recorded at gadolinium. According to this research, we could not only discover the fact that was iodine could effect on MR signal, but also the pattern is different as various sequences compare to gadolinium. Therefore, we expect useful diagnostic MR image in clinical field with this quantitative data for deciding protocol regarding MRI and CT scan order.

Clinical Characteristics of Tuberculosis in North Korean Refugees (북한이탈주민에서의 결핵의 임상적 고찰)

  • Choi, Chang-Min;Jeong, Woo-Kyoung;Kang, Cheol-In;Kim, Doh-Hyung;Kim, Young-Keun;Heo, Sang-Taek;Kim, Hee-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.3
    • /
    • pp.285-289
    • /
    • 2006
  • Background : North Korea's economic and public health problems began in the early 1990s as a result of the gradual loss of economic support from its communist allies, combined with an inordinate number of natural disasters. The decline in public health has increased the incidence of tuberculosis in North Koreans and refugees. This study investigated tuberculosis situation in North Korean refugees in order to prepare for the future impact of tuberculosis control in Korea. Material and Methods : From 2001 to 2005, tuberculosis patients among North Korean refugees who were diagnosed before or after arriving in South Korea, based on the official records of OO hospital, were enrolled in this study. The demographic and clinical data of the cases were evaluated retrospectively. Results : A total of 42 TB cases were reviewed during the study period. Of these, 37 (88.1%) cases were pulmonary TB. based on the cases identified among the number of North Korean refugees' arriving each year, the annual incidence of pulmonary TB were 900 per 100,000 in 2004, 700 in 2003, The number of smear-positive patients was 20 (47.6%) and the number of culture-positive patients was 18 (42.9%). Of the M. tuberculosis isolates, 2 cases were found to be susceptible to all anti-TB drugs available, 4 were resistant to isoniazid, and 3 were multi-drug resistant. Conclusion : The prevalence of pulmonary TB in North Korean Refugees is high. In addition, North Korean refugees suffer from more severe tuberculosis in bacteriological and radiological aspects.

Quantitative Assessment using SNR and CNR in Cerebrovascular Diseases : Focusing on FRE-MRA, CTA Imaging Method (뇌혈관 질환에서 신호대 잡음비와 대조도대 잡음비를 이용한 정량적평가 : FRE-MRA, CTA 영상기법중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.493-500
    • /
    • 2017
  • In this study, data analysis has been conducted by INFINITT program to analyze the effect of signal to noise ratio(SNR) and contrast to noise ratio(CNR) of flow related enhancement(FRE) and computed tomography Angiography(CTA) on cerebrovascular diseases for qualitative evaluations. Based on the cerebrovascular image results achieved from 63 patients (January to April, 2017, at C University Hospital), we have selected 19 patients that performed both FRE-MRA and CTA. From the 19 patients, 2 were excluded due to artifacts from movements in the cerebrovascular image results. For the analysis conditions, we have set the 5 part (anterior cerebral artery, right and left Middle cerebral artery, right and left Posterior cerebral artery) as the interest area to evaluate the SNR and CNR, and the results were validated through Independence t Test. As a result, by averaging the SNR, and CNR values, the corresponding FRE-MRA achieved were: anterior cerebral artery ($1500.73{\pm}12.23/970.43{\pm}14.55$), right middle cerebral artery ($1470.16{\pm}11.46/919.44{\pm}13.29$), left middle cerebral artery ($1457.48{\pm}17.11/903.96{\pm}14.53$), right posterior cerebral artery ($1385.83{\pm}16.52/852.11{\pm}14.58$), left posterior cerebral artery ($1318.52{\pm}13.49/756.21{\pm}10.88$). by averaging the SNR, and CNR values, the corresponding CTA achieved were: anterior cerebral artery ($159.95{\pm}12.23/123.36{\pm}11.78$), right middle cerebral artery ($236.66{\pm}17.52/202.37{\pm}15.20$), left middle cerebral artery ($224.85{\pm}13.45/193.14{\pm}11.88$), right posterior cerebral artery ($183.65{\pm}13.47/151.44{\pm}11.48$), left posterior cerebral artery ($177.7{\pm}16.72/144.71{\pm}11.43$) (p < 0.05). In conclusion, MRA had high SNR and CNR value regardless of the cerebral infarction or cerebral hemorrhage observed in the 5 part of the brain. Although FRE-MRA consumed longer time, it proved to have less side effect of contrast media when compared to the CTA.

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Combined Exercise in Premenopausal Women Effects on Body Composition and Bone Mineral Density (복합운동이 폐경 전 성인여성의 신체조성 및 골밀도에 미치는 영향)

  • Kim, Kyung-Hee;Lee, Jung-Hee;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.145-155
    • /
    • 2017
  • The purpose of this study was to compare and analyze changes in body composition and bone mineral density (BMD) during combined exercise in premenopausal women who did not take regular diet or regular physical activity within 6 months, In addition to being able to recognize the importance of pre-menopausal women's health and exercise, it also provides basic data for the development of educational programs for early prevention of osteoporosis prevention education I want to. The average age of the subjects in their 30s was 35.44 years and their height was 158.89 cm in their 30s. The average age of the subjects in their 40s was 41.89 and their average height was 160.78 cm in their 40s. Body composition, BMI, and body fat percentage were higher in the 30s, and bone mineral content, lean body mass, skeletal muscle mass, body weight, body fat mass and waist circumference were higher in their forties. Lumbar spine BMD and femur density were higher in their 30s than their 40s. Body composition, skeletal muscle mass, and fat mass increased in the 30s body composition by age - related complex exercise in premenopausal women, body fat mass, body fat percentage, waist circumference decreased. Body mass, body fat, body fat percentage, and BMI decreased in the 40s. The lumbar spine, the lumbar spine, the lumbar spine, and the femur were increased in the lumbar spine, the lumbar spine, the femur, and the femur. In the post-analysis results, changes in body composition were statistically significant due to decrease in muscle mass, body weight, body fat mass and BMI after combined exercise. In the change of bone density, lumbar spine BMD was measured as lumbar spine 1, lumbar spine 2, lumbar spine 3, And the femur density was increase.

Effect of Patient Size on Image Quality and Dose Reduction after Added Filtration in Digital Chest Tomosynthesis (부가필터를 적용한 디지털 흉부단층합성검사에서 환자 체형에 따른 화질 평가와 선량감소 효과)

  • Bok, Geun-Seong;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.23-30
    • /
    • 2018
  • To evaluate the effect of patient size on effective dose and image quality for Digital Chest Tomosynthesis(DTS) using additional 0.3 mm copper filtration. Eighty artificial nodules were placed in the thorax phantom("Lungman," Kyoto Kagaku, Japan), and Digital Chest Tomosynthesis(DTS) images of the phantom were acquired both with and without added 0.3 mm Cu filtration. To simulate patients of three sizes: small, average size and oversize, one or two 20-mm-thick layer of PMMA(polymethyl methacrylatek) blocks were placed on the phantom. The Effective dose was calculated using Monte Carlo simulations. Two evaluations of image quality methods have been employed. Three readers counted the number of nodules detected in the lung, and the measured contrast-to-noise ratios(CNRs) were used. Data were analyzed statistically. The ED reduced $26{\mu}Sv$ in a phantom, $33{\mu}Sv$ in one 20-mm-thick layer of PMMA block placed on the phantom, and $48{\mu}Sv$ in two 20-mm-thick layer of PMMA blocks placed on the phantom. The Effective dose(ED) differences between DTS with and without filtration were significant(p<0.05). In particular, when we used two 20-mm-thick layer of PMMA blocks placed on the phantom, the ED was significantly reduced by 36% compared with those without additional filtration. Nodule detection sensitivities were not different between with and without added filtration. Differences of CNRs were statistically insignificant(p>0.05). Use of additional filtration allows a considerable dose reduction during Digital Chest Tomosynthesis(DTS) without loss of image quality. In particular, additional filtration showed outstanding result for effective dose reduction on two 20-mm-thick layer of PMMA blocks placed on the phantom. It applies to overweight patients.

Gadoteridol's Signal Change according to TR, TE Parameters in T1 Image (T1영상에서 TR, TE 매개변수에 따른 Gadoteridol의 신호강도 변화)

  • Jeong, Hyun Keun;Jeong, Hyun Do;Nam, Ki Chang;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.9
    • /
    • pp.117-124
    • /
    • 2015
  • In this paper, we introduce how to control TR, TE physical MR parameters for managing $H_1$ spin's SI(Signal Intensity) which is combined with gadolinium following administration MR agent in T1 effect for diagnostic usefulness. we used MRI phantom made with 0.5 mol Gadoteridol. This phantom was scanned by FSE sequence with different TR, TE parameters. In this study, to make T1 effect, TR was 200, 250, 300, 350, 400, 450, 500, 550, 600 msec. In addition to, TE was 6.2, 12.4, 18.6, 21.6 msec. The results were as follows ; Each RSP(Reaction Starting Point) was 100, 50, 40, 30 mmol in TE 6.2, 12.4, 18.6, 21.6 msec being irrelevant to TR. In MPSI(Max Peak Signal Intensity), 4 mmol was showed in TR 200 msec while peak signal was decreased to low concentration mol in TR 250-600 msec. In terms of RA(Reaction Area), the highest SI was TE 6.2 msec in TR 200-600msec. According to the study, we are able to recognize it is possible to control enhance rates by managing TR and TE of MR parameters; moreover, we expect that enhanced T1 image in MR clinical field can be performed in a practical way with this quantitative data.