• Title/Summary/Keyword: Radiological Protection

Search Result 420, Processing Time 0.027 seconds

Dose Distribution of Gamma Irradiators

  • Park, Seung-Woo;Shin, Sang-Hun;Son, Ki-Hong;Lee, Chang-Yeol;Kim, Kum-Bae;Jung, Hai-Jo;Ji, Young-Hoon
    • 대한방사선방어학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.62-63
    • /
    • 2010
  • PDF

Conclusions and Suggestions on Low-Dose and Low-Dose Rate Radiation Risk Estimation Methodology

  • Sakai, Kazuo;Yamada, Yutaka;Yoshida, Kazuo;Yoshinaga, Shinji;Sato, Kaoru;Ogata, Hiromitsu;Iwasaki, Toshiyasu;Kudo, Shin'ichi;Asada, Yasuki;Kawaguchi, Isao;Haeno, Hiroshi;Sasaki, Michiya
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.14-23
    • /
    • 2021
  • Background: For radiological protection and control, the International Commission on Radiological Protection (ICRP) provides the nominal risk coefficients related to radiation exposure, which can be extrapolated using the excess relative risk and excess absolute risk obtained from the Life Span Study of atomic bomb survivors in Hiroshima and Nagasaki with the dose and dose-rate effectiveness factor (DDREF). Materials and Methods: Since it is impossible to directly estimate the radiation risk at doses less than approximately 100 mSv only from epidemiological knowledge and data, support from radiation biology is absolutely imperative, and thus, several national and international bodies have advocated the importance of bridging knowledge between biology and epidemiology. Because of the accident at the Tokyo Electric Power Company (TEPCO)'s Fukushima Daiichi Nuclear Power Station in 2011, the exposure of the public to radiation has become a major concern and it was considered that the estimation of radiation risk should be more realistic to cope with the prevailing radiation exposure situation. Results and Discussion: To discuss the issues from wide aspects related to radiological protection, and to realize bridging knowledge between biology and epidemiology, we have established a research group to develop low-dose and low-dose-rate radiation risk estimation methodology, with the permission of the Japan Health Physics Society. Conclusion: The aim of the research group was to clarify the current situation and issues related to the risk estimation of low-dose and low-dose-rate radiation exposure from the viewpoints of different research fields, such as epidemiology, biology, modeling, and dosimetry, to identify a future strategy and roadmap to elucidate a more realistic estimation of risk against low-dose and low-dose-rate radiation exposure.

The System of Radiation Dose Assessment and Dose Conversion Coefficients in the ICRP and FGR

  • Kim, Sora;Min, Byung-Il;Park, Kihyun;Yang, Byung-Mo;Suh, Kyung-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.424-435
    • /
    • 2016
  • Background: The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. Materials and Methods: The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. Results and Discussion: A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. Conclusion: The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment.

Environmental Radiation Protection in Medical Institutions

  • Han, Eun-Ok;Dong, Kyung-Rae
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.91-95
    • /
    • 2010
  • The study aimed to measure the levels of radiation protection for radiologists in medical institutions in three environmental categories (physical, administrative and social) and to establish a data base which can be used to increase awareness of environmental radiation protection in medical institutions within Korea. The study surveyed 10% of radiologists working in radiology departments in medical institutions which are supervised by the National Dose Registry overseen by the Korean Food and Drug Administration(KFDA). This study found that the level of environmental radiation protection was higher in the capital area and in larger hospitals. On the other hand, the study shows environmental radiation protection was lower in the Youngnam area and in clinics. Results from the questionnaires indicate the level of environmental radiation protection was higher when radiologists were given an individual dosimeter but lowest when the radiation protection apron quality test was conducted. Environmental radiation protection is an important factor for radiologists to conduct activities in a safe and protected environment. However, this study shows there are differences in the level of environmental radiation protection in medical institutions and location within Korea. In particular, the level of environmental radiation protection was lower in clinics, appropriate intervention strategies befitting these conditions are needed based on medical institution classification and location in order to improve the level of environmental protection.

Single Particle Irradiation System to Cell (SPICE) at NIRS

  • Yamaguchi, Hiroshi;Ssto, Yukio;Imaseki, Hitoshi;Yasuda, Nakahiro;Hamano, Tsuyoshi;Furusawa, Yoshiya;Suzuki, Masao;Ishikawa, Takehiro;Mori, Teiji;Matsumoto, Kenichi;Konishi, Teruaki;Yukawa, Masae;Soga, Fuminori
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.267-268
    • /
    • 2002
  • Microbeam is a new avenue of radiation research especially in radiation biology and radiation protection. Selective irradiation of an ionizing particle to a targeted cell organelle may disclose such mechanisms as signal transaction among cell organelles and cell-to-cell communication in the processes toward an endpoint observed. Bystander effect, existence of which is clearly evidenced by application of the particle microbeam to biological experiments, suggests potential underestimation in the conventional risk estimation at low particle fluence rates, such as environment of space radiations in ISS (International Space Station). To promote these studies we started the construction of our microbeam facility (named as SPICE) to our HVEE Tandem accelerator (3.4 MeV proton and 5.1 MeV $^4$He$\^$2+/). For our primary goal, "irradiation of single particle to cell organelle within a position resolution of 2 micrometer in a reasonable irradiation time", special features are considered. Usage of a triplet Q magnet for focussing the beam to submicron of size is an outstanding feature compared to facilities of other institutes. Followings are other features: precise position control of cell dish holder, design of the cell dish, data acquisition of microscopic image of a cell organelle (cell nucleus) and data processing, a reliable particle detection, soft and hard wares to integrate all these related data, to control and irradiate exactly determined number of particles to a targeted spot.

  • PDF

Comparison of Off-site Radiological Dose Due to the Routine Release of Gaseous Radioactive Effluents Based on the Korean and Japanese Regulatory Recommendations

  • Hwang, Won Tae;Kim, Chang Lak;Lee, Cheol-Woo;Han, Moon Hee
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.4
    • /
    • pp.161-165
    • /
    • 2019
  • Background: Not only regulatory framework including radiation protection quantities and regulatory standards, but also methodology for regulatory compliance may be different in each country due to inherent philosophy for radiation protection. Materials and Methods: Based on the Korean regulatory models, off-site radiological dose resulting from the routine releases of gaseous radioactive effluents was calculated by applying the parameter values and assumptions recommended in the Korean and Japanese regulations. Results and Discussion: Effective dose for adult based on the Korean recommendation were 17.5 and 1.6 times higher than those of Japanese recommendation for 131I and 133I, respectively, for the same atmosphere dispersion and ground deposition factors. Conclusion: It was due to different parameter values and assumptions recommended for the purpose of evaluating compliance with dose criteria for the radiation protection of the public in each country.