• Title/Summary/Keyword: Radiological

Search Result 7,182, Processing Time 0.028 seconds

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Analysis of Frequent Disease and Medical Expenses Structure of Patients Admitted in a Vaterans Hospital (일개 보훈병원 입원환자의 상병 및 진료비 구조분석)

  • Kim, Kyoung-Hwan;Lee, Sok-Goo;Kim, Jeong-Yeon
    • Journal of agricultural medicine and community health
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • Objectives: This study attempts to analyze the length of hospital stay and expenses of frequent disease admitted in a Vaterans Hospital. Methods: Data was collected from January 1, 2001 to December 31, 2003 from the Claim records of 9,640 patients in a Vaterans Hospital. Results: The results were as follows: 1. In age & sex distribution, there was male 70.9%, female 29.1%, and 35.8% of them is 70 age group. Frequency by insurance program was Health insurance 78.1%, Medical aid 14.2%, no insurance 4.1%, others 3.6%. Distribution of each department was internal medicine 28.3%, orthopedic surgery 21.3%, surgery 16.6%, neurosurgey 7.1%, pediatrics 5.9%. Also, in the veterans group, male to female patient ratio was 99.3% male to 0.7% female, them over 70 years old was 51.6%, and them which live in daejeon was 43.5%. 2. In frequency of disease, there was gastroenteritis 4.8%, pneumonia 3.8%, cartaract 3.7%, cerebral infarct 3.2%, hyperplasia of prostate 3.0%. In frequency of korean standard classification of diseases, there was injury and poisoning and certain other consequences of external causes 17.1%, diseases of digestive system 16.1%, diseases of musculoskeletal system and connective tissue 13.9%, diseases of respiratory system 9.4%, diseases of genitourinary system 8.6%. Also, in veterans group, frequency of them was diseases of musculoskeletal system and connective tissue 19.4%, diseases of digestive system 16.8%, injury and poisoning and certain other consequences of external causes 15.7%, diseases of genitourinary system 9.7%, diseases of circuatory system 8.2%. 3. Average length of hospital stay was 29.0 days for total patients, 51.8 days for the veterans group, 15.7 days for the non-veterans one. Average total expenses was 3,669,579 won, the veterans group 7,263,877 won, the non-veterans one 1,560,333 won. The ratio of insurer to insuree was 55.2 : 44.8, the ratio of amount paid by patient in the veterans group 61.7%, in the non-veterans one 33.0%. 4. In items of medical expenses, fee for hospital accommodation was 34.7%, fee for medication 13.2%(injection 7.8%, drug 5.4%), fee for service 48.6%(physical therapy 26.3%, operation 9.7%, laboratory examination 5.2%, radiological examination 3.1%, etc), others 3.4%. In them for the veterans group, fee for physical therapy was 35.3%, fee for hospital accommodation 35.2%, fee for injection 6.2%, fee for operation 5.9%, for the non-veterans one, fee for hospital accommodation 35.7%, fee for operation 16.4%, fee for injection 11.4%, fee for laboratory examination 8.3%. 5. In the comparison of the frequency by Korean standard classification of diseases and distance between the hospital and home, the region under 21.5Km was more frequent in symptoms, signs an abnormal clinical and laboratory findings 56.0%, injury and poisoning and certain other consequences of external causes 55.6%, diseases of the eye and adnexa 52.9%, the one over 21.5Km was more frequent in neoplasms 57.4%, diseases of musculoskeletal system and connective tissue 55.9%, diseases of genitourinary system 53.5%.

  • PDF