• Title/Summary/Keyword: Radiologic imaging

Search Result 364, Processing Time 0.025 seconds

Pediatric mandibular chronic nonbacterial osteomyelitis: A case report with 12 years of radiologic follow-up

  • Sehyun Choi;Min-Ji Kim;Sang-Hoon Kang;In-Woo Park
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.93-104
    • /
    • 2024
  • Chronic nonbacterial osteomyelitis(CNO) is histologically characterized by nonspecific osteitis. This inflammatory disorder, which lacks an infectious origin, typically presents with chronic pain and swelling at the affected site that can persist for months or even years. However, it is rare for CNO to affect the mandible. A 10-year-old girl presented with a primary complaint of pain in her left mandible. She had no significant medical or dental history. On examination, swelling was visible on the left buccal side, and imaging revealed radiolucent bone deterioration within the left mandible. This case report presents the radiological changes observed over a 12-year follow-up period. Variations in radiopacity, radiolucency, and periosteal reactions were noted periodically. This case highlights the radiological characteristics and findings that are crucial for the diagnosis of CNO, a condition for which no clear diagnostic criteria are currently available.

Usefulness of FTP Module on OCS for PACS Registration of External Medical Images (외부의료영상의 PACS 등록 시 OCS상 FTP Module의 유용성)

  • Jung, Myung-Jin;Dong, Kyung-Rae;Ji, Yeon-Sang;Choi, Jung-Gil;Jeon, Jae-Doo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.35-41
    • /
    • 2009
  • This study was conducted to improve performance flow of PACS registration and output of external medical images by developing or adding File Transfer Protocol(FTP) Module on Order Communication System(OCS) and to upgrade efficiency of performance. The numbers of requests for examination of external medical images from January 2004 to December 2007 were investigated and the numbers of cases of examinations and losses were done respectively from January to June, 2007 as a period before the improvement and from July to December, 2007 as a period after it. Satisfaction of persons inputting external medical images of CD was asked directly before and after the improvement. When the numbers of requests for examination of external medical images from 2004 to 2007 2004 were investigated, they were 12,783, 16,774, 21,613 and 27,487 cases in 2004, 2005, 2005 and 2007 respectively. For the numbers of the requests from January to December, 2007 it was the lowest in February by recording 1846 and it was 2800 in October. While the number of loss of external medical images was averagely 3.6 before using FTP Module on OCS, it reduced to 0 and satisfaction increased to 98% after it. By utilizing FTP Module on OSC for PACS registration of external medical images, the images were delivered simultaneously with occurrence of order, PACS registration of many patients was conducted together and CDs were returned to patients immediately after sending images from outpatient clinics or wards to remove possibility of losing them. In addition, because the module was established on OCS and data were sent associated with order, problems related with order were decreased. By eliminating movement distance it was turned out to be very effective in terms of time and space.

  • PDF

Computerizing Clinical Laboratory with Clinical Devices Interface : I. With a focus on ABGA(Arterial Blood Gas Analyzer) (임상 의료장비 인터페이스를 이용한 검사실 전산화 구현 : I. ABGA(Arterial Blood Gas Analyser)를 중심으로)

  • Kim, Sun-Chil;Kwon, Deok-Moon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.8 no.1
    • /
    • pp.21-26
    • /
    • 2006
  • Hospitals these days are trying to introduce the a practice has recently been generalized in the test or diagnosis process, where test results and images from different test labs are interlinked together. This process is identical to that of physical aspect in EMR process, which computerizes the paper results within the hospital. One of the prerequisites for the process of computerizing test results is the interface between clinical test devices in the test labs. However, due to the variety of prescription inputs, disparity of test result papers, complexity of job in test labs and diversify of interfaces among the different devices, interconnection with the hospital information system is a complicated job. A universal control of clinical test devices which have independent communication protocols has become possible by connecting them with an interface workstation. As for the patients, waiting time for test has been reduced, and, thanks to the synchronized result retrieval system, it has become possible to check the test results on the very day of the test. As a result, the length of hospitalization has been reduced, too. In terms of workflow, as the transfer of charts and transfer of result papers are separated, the embarrassing job of collecting result papers has disappeared. As patients' test appointment and the results processing can be made on-line, extra work for doctors have disappeared. And, thanks to the computerization of test results information management, the job of statistical processing has become convenient.

  • PDF

General Requirements Pertaining to Radiation Protection in Diagnostic X-ray Equipment -KFDA DRS 1-1-3 : 2008 base on IEC 60601-1-3:2008- (진단용 엑스선 장치에 있어서 방사선 방어에 대한 일반 요구사항 -IEC 60601-1-3:2008에 근거한 KFDA DRS 1-1-3:2008-)

  • Kang, Hee-Doo;Dong, Kyung-Rae;Kweon, Dae-Cheol;Choi, Jun-Gu;Jeong, Jae-Ho;Jung, Jae-Eun;Ryu, Young-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.69-77
    • /
    • 2009
  • This study gives an account of the collateral standards in IEC 60601-1-3: 2008 specifying the general requirements for basic safety and essential performance of diagnostic X-ray equipment regarding radiation protection as it pertains to the production of X-rays. The collateral standards establish general requirements for safety regarding ionization radiation in diagnostic radiation systems and describe a verifiable evaluation method of suitable requirements regarding control over the lowest possible dose equivalent for patients, radiologic technologists, and others. The particular standards for each equipment can be determined by the general requirements in the collateral standard and the particular standard is followed in the risk management file. The guidelines for radiation safety of diagnostic radiation systems is written up in ISO 13485, ISO 14971, IEC 60601-1-3(2002)1st edition, medical electric equipment part 1-3, and the general requirements for safety-collateral standards: programmable electrical medical systems. Therefore the diagnostic radiation system protects citizens' health rights with the establishment and revisions of laws and standards for diagnostic radiation systems as a background for the general requirements of radiation safe guards applies, as an international trend, standards regarding the medical radiation safety management. The diagnostic radiation system will also assure competitive power through a conforming evaluation unifying the differing standards, technical specifications, and recognized processes.

  • PDF

Radiologic Approach for Pulmonary Vasculitis (폐혈관염의 영상의학적 접근)

  • Chohee Kim;Yoon Kyung Kim;Joungho Han
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.791-807
    • /
    • 2021
  • Vasculitis is a systemic disease, characterized by inflammation of the vascular wall. Although rare, it is sometimes life-threatening due to diffuse pulmonary hemorrhage or acute glomerulonephritis. Besides primary vasculitis, whose cause is unknown, numerous conditions such as autoimmune diseases, drugs, infections, and tumors can cause secondary vasculitis. Vasculitis displays various non-specific symptoms, signs, and laboratory findings; hence, diagnosis of the disease requires integration of various results including clinical features, imaging findings, autoantibody tests, and pathological findings. In this review, we have discussed the clinical, radiologic, and pathological features of vasculitis. Further, we elaborated the imaging findings and differential diagnosis of typical vasculitis that frequently involves the lung and introduced a new international classification of vasculitis, the Diagnostic and Classification Criteria in Vasculitis.

Immunoglobulin G4-Related Disease in the Thorax: Imaging Findings and Differential Diagnosis (흉부에서 발생한 IgG4 연관 질환: 영상 소견 및 감별진단)

  • Yookyung Kim;Hye Young Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.826-837
    • /
    • 2021
  • Immunoglobulin G4-related disease (IgG4-RD) is a chronic inflammatory condition involving multiple organs, including the salivary or lacrimal glands, orbit, pancreas, bile duct, liver, kidney, retroperitoneum, aorta, lung, and lymph nodes. It is histologically characterized by tissue infiltration with lymphocytes and IgG4-secreting plasma cells, storiform fibrosis, and obliterative phlebitis. In the thoracic involvement of IgG4-RD, mediastinal lymphadenopathy and perilymphangitic interstitial thickening of the lung are the most common findings. Peribronchovascular and septal thickening and paravertebral band-like soft tissue are characteristic findings of IgG4-RD. Other findings include pulmonary nodules or masses, ground-glass opacity, alveolar interstitial thickening, pleural effusion or thickening, mass in the chest wall or mediastinum, and arteritis involving the aorta and coronary artery. Radiologic differential diagnosis of various malignancies, infections, and inflammatory conditions is needed. In this review, we describe the imaging findings of IgG4-RD and the radiologic differential diagnoses in the thorax.

Radiologic and Pathologic Findings of Atypical Ductal Hyperplasia in the Male Breast: Case Report and Literature Review (남성 유방에서의 비정형유관증식증의 영상 및 병리 소견에 대한 고찰: 증례 보고 및 문헌고찰)

  • Ara Ko;Hye Shin Ahn;Seungho Lee;Su Min Ha;Min Kyoon Kim;Hee Sung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1504-1510
    • /
    • 2020
  • In this case report, we present the radiologic and pathologic findings of atypical ductal hyperplasia (ADH) in the male breast. It is well known that a high-risk lesion such as ADH is a precursor of breast cancer in females. However, the clinical significance of these lesions in the male breast is still uncertain because male breasts mainly consist of ducts without lobule formation, unlike the female breast. To our knowledge, imaging findings of ADH in the male breast have not been reported previously, except for a few studies on the pathologic findings of these lesions. Through this paper, we would like to present the possible imaging features of this high-risk lesion in the male breast and review the related literature.

Leukoencephalopathy and Disseminated Necrotizing Leukoencephalopathy Following Intrathecal Methotrexate Chemotherapy and Radiation Therapy for Central Nerve System Lymphoma or Leukemia

  • Kim, Ji-Yeon;Kim, Sung-Tae;Nam, Do-Hyun;Lee, Jung-Il;Park, Kwan;Kong, Doo-Sik
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.304-310
    • /
    • 2011
  • Objective : Intrathecal methotrexate (MTX) therapy combined with whole brain radiotherapy (WBRT) is one of the major treatment modalities for leukemia and lymphoma involving the central nervous system (CNS). The purpose of this study was to retrospectively determine the incidences of leukoencephalopathy and disseminated necrotizing leukoencephalopathy (DNL) following intrathecal MTX therapy for CNS lymphoma or leukemia and to assess the potential risk factors. Methods : Between January 2000 and August 2009, 143 patients with CNS lymphoma or leukemia received intrathecal MTX therapy alone or in combination with WBRT at a single institution. Patients were followed up clinically and radiologically at regular two- or three-month intervals. Medical records were reviewed to obtain information regarding the patients' demographics, medical histories, radiologic characteristics, treatments, and clinical courses. Results : On follow-up MR images, leukoencephalopathy was found in 95 of 143 patients (66.4%). The median time to develop leukoencephalopathy was 6.6 months. Among those with leukoencephalopathy, four patients showed seven extensive white-matter changes with strongly enhancing lesions demonstrating DNL. Histological confirmation was done in six lesions of three patients and radiological diagnosis alone in one patient. Four lesions spontaneously disappeared on MR images without any treatment, with a mean duration of 14 months before disappearance of DNL. Conclusion : Leukoencephalopathy is a common phenomenon that occurs following intrathecal MTX therapy; however, DNL occurs at a very low incidence. For newly developed enhancing lesions, consideration for the occurrence of DNL should be taken to avoid unnecessary invasive procedures or therapies.

The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC (자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향)

  • Yoon, Seok-Hwan;Choi, Jun-Gu;Han, Dong-Kyoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

A Study on the Status and Improvement Direction of Radiographic Imaging Examination Assessment in Korea Medical Institutions (한국 의료기관의 방사선 영상검사 평가 현황 및 과제)

  • Young-Kwon Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.565-572
    • /
    • 2023
  • This study was conducted to analyze the status radiological imaging examinations assessment in Korea medical institutions conducted in the public sector and suggest a direction for improvement. Among the assessment of medical institutions, the main assessment related to radiographic imaging examinations are the certification evaluation of medical institutions and the adequacy assessment of radiographic imaging examinations. The certification evaluation of medical institutions evaluates the image inspection operation process, provision of accurate results, and compliance with safety management procedures. In the assessment of adequacy of radiographic imaging examinations, structural indicators related to manpower and equipment, patient evaluation implementation rate, and exposure reduction programs were included. However, for safer and higher-quality radiological imaging examinations, it is necessary to increase the participation rate of medical institutions in certification evaluations. In addition, it is necessary to improve the manpower indicator, and incentive payments can be considered to induce quality improvement of medical institutions in the future. Integrated management of radiation exposure at the national level should also be carried out simultaneously.