• Title/Summary/Keyword: Radiologic Science

Search Result 479, Processing Time 0.021 seconds

A Study on the Chest Indirect Radiography (흉부X선 간접촬영의 촬영조건과 화질에 관한 조사연구)

  • Kim, Hark-Sung;Lee, In-Ja;Kim, Sung-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.11-19
    • /
    • 2003
  • chest Indirect radiography were taken at 44 medical facilities in Seoul area. The results were as follows: 1. The average tube voltage was 98.2 kVp in case of 100 mm film and 91.3 kVp in case of 70 mm film. 2. The average tube current was 18.1 mAs in case of 100 mm film and 42.5 mAs in case of 70 mm film. 3. In the physical evaluation of chest Indirect radiographs, the density in case of 100 mm film was similar to that in case of 70 mm film. 4. In the visual evaluation of chest Indirect radiographs, the score of identification in case of 100 mm film was higher than that in case of 70 mm film. 5. The average dose of radiation into the skin was 1.38 mGy in case of 100mm film and 4.59 mGy in case of 70 mm film. In conclusion, the image quality of chests was excellent and the dose of radiation into the skin decreased in case of 100 mm film.

  • PDF

Radiologic Evaluation and Structured Reporting Form for Extrahepatic Bile Duct Cancer: 2019 Consensus Recommendations from the Korean Society of Abdominal Radiology

  • Dong Ho Lee;Bohyun Kim;Eun Sun Lee;Hyoung Jung Kim;Ji Hye Min;Jeong Min Lee;Moon Hyung Choi;Nieun Seo;Sang Hyun Choi;Seong Hyun Kim;Seung Soo Lee;Yang Shin Park;Yong Eun Chung;The Korean Society of Abdominal Radiology
    • Korean Journal of Radiology
    • /
    • v.22 no.1
    • /
    • pp.41-62
    • /
    • 2021
  • Radiologic imaging is important for evaluating extrahepatic bile duct (EHD) cancers; it is used for staging tumors and evaluating the suitability of surgical resection, as surgery may be contraindicated in some cases regardless of tumor stage. However, the published general recommendations for EHD cancer and recommendations guided by the perspectives of radiologists are limited. The Korean Society of Abdominal Radiology (KSAR) study group for EHD cancer developed key questions and corresponding recommendations for the radiologic evaluation of EHD cancer and organized them into 4 sections: nomenclature and definition, imaging technique, cancer evaluation, and tumor response. A structured reporting form was also developed to allow the progressive accumulation of standardized data, which will facilitate multicenter studies and contribute more evidence for the development of recommendations.

Evaluation and Analysis of Scattered Radiation Dose according to Factors in General X-ray Examination (일반엑스선영상검사의 인자에 따른 산란방사선량 평가 및 분석)

  • Dong-Kyung Jung;Myeong-Hwan Park;Jeong-Min Seo
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.13-19
    • /
    • 2024
  • Control of scattered radiation is one of very important factors in the use of medical radiation. In general X-ray exam, the causes, measurement methods, and the kind of detectors of scattered rays within the radiation area are diverse. In this study, the dose of scattered ray was measured by changing the thickness of the polycarbonate phantom and the tube voltage. As a result of measurement of scattered radiation, the results show that the scattered dose significantly(p<.05) increased with growing of thickness of phantom in the tube voltage 40, 50 and 60 kVp(F(p)<.05, R2>64%). As tube voltage increased at all phantom thicknesses, the scattered dose also significantly(p<.05) increased(F(p)<.05, R2>69%). In cases where a significant correlation was shown, the coefficient of determination of more than 60% was shown in regression analysis. The results of this study can be used as data on scattered radiation dose according to the tube voltage and the object thickness in general X-ray imaging exam.

Idiopathic Interstitial Pneumonias : Radiologic Findings (특발성간질성폐렴의 방사선학적 소견)

  • Lee, Kyung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.2
    • /
    • pp.129-144
    • /
    • 2003
  • Usual interstitial pneumonia/Idiopathic pulmonary fibrosis, nonspecific interstitial pneumonia, Cryptogenic organizing pneumonia(bronchiolitis obliterans organizing pneumonia : BOOP), Acute interstitial pneumonia, respiratory bronchiolitis-associated interstitial lung disease, Desquamative interstitial pneumonia, Lymphoid interstitial pneumonia.

Comparison of Average Glandular Dose in Screen-Film and Digital Mammography Using Breast Tissue-Equivalent Phantom (유방조직등가 팬텀을 이용한 Screen-Film과 Digital Mammography에서의 평균 유선선량)

  • Shin, Gwi-Soon;Kim, Jung-Min;Kim, You-Hyun;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.13-23
    • /
    • 2007
  • In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate(IP). We measured average glandular doses(AGD) in screen-film mammography(SFM) system with slow screen-film combination, computed mammography(CM) system, indirect digital mammography(IDM) system and direct digital mammography(DDM) system using brest tissue-equivalent phantom(glandularity 30%, 50% and 70%). The results were shown as follows : AGD values for DDM system were highest than those for other systems. Although automatic exposure control(AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter(Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in oder to estimate a patient radiation dose.

  • PDF

CLINICAL AND RADIOLOGIC STUDY OF ODONTOGENIC KERATOCYST IN THE JAWS (악골에 발생한 치성각화낭종의 임상 및 방사선학적 연구)

  • Choi Chong Ho;Park Chang Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.163-171
    • /
    • 1987
  • The author has clinically and radiologically investigated 57 cases of odontogenic keratocyst in 47 patients consisted of 26 males and 21 females aged from.2 to 63 years, who were pathologically diagnosed as odontogenic keratocyst at infirmaries of dental colleges, Yonsei University and Seoul national university during 1965-1986. The results were as follows: 1. The peak incidence of the disease was on their teenagers (29.8%). The ratio of Male/Female was 1.23:1 and incidence rate of males showed higher than their counterpart. 2. The most frequent complaints were swelling in (65.9%) followed by pus discharge, unknown mass, pain, residual root. 3. The most common site was mandibular third molar and mandibular ramus region (15.8%) followed by mandibular body and ramus, mandibular third molar, mandibular anterior teeth. Incidence of this disease in mandible was higher than in maxilla. 4. The lesions not associated with adjacent teeth were (14.0%) and in the lesions associated with adjacent teeth (35.1%) showed root resorption, (50.9%) were without root resorption, (35.1%) showed tooth migration and (50.9%) were without tooth migration. 5. The border types of the lesions were scalloped type in (52.6%), smooth type in (47.4%) and morphological type were unilocular in (50.9%), multilocular in (49.1%). 6. The radiologic cyst type of the lesions were follicular type (42.1%) followed by primordial, unclassified odontogenic, residual, lateral periodontal, median mandibular, globulomaxillary type.

  • PDF

Design of High Frequency Resonant High-tension Transformer in Inverter Type X-Ray Generator (인버터식 X선발생장치용 고주파 공진형 고압변압기 등의 설계)

  • Lee, Seong-Kil;Choi, Sung-Kwan
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.5-11
    • /
    • 2001
  • Most of X-ray generator had used rectifier type transformer with high tension generator which is supplied in a clinical diagnosis. Because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. In these days, high tension generator for inverter type X-ray generator is being supplied from a broad which uses semi-conductor switching element for the electric power that have a high speed switching ability to solve these problem. But, semi-conductor element with large capacity is used with X-ray tube's large consumption power and diffusion is difficult in the small size hospital because production cost is going up by doing digital control through DSP. Therefore, this paper designed and manufactured CR type voltage divider for feedback control of tube voltage with high frequency resonance type inverter and for high tension transformer with high frequency. It was to make economical diffusion type X-ray generator which has wide output voltage and load extent. It was preyed that the X-ray generator had the stability of X-ray tube's output characteristics.

  • PDF

Analysis of Scatter Ray Distribution Using GEANT4-GATE Simulation and Effectiveness of Silicone Pad in Digital Mammography (디지털유방촬영에서 Geant4-GATE를 이용한 산란선의 영향분석과 감소방안에 관한 연구)

  • Kim, Myeong-soo;Kim, Young-kuen;Jang, Young-Il
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.175-180
    • /
    • 2019
  • In this study, we have researched the effectiveness of silicone pad. A distribution of scatter ray in mammography was evaluated using Monte-Carlo (MC) simulation technique and then a silicone pad was applied to remove the scatter ray for improving image quality. Molybdenum target and Molybdenum filter combination made a difference of 59.8% to a number of photon at 17.5 keV. On the other hand, Tungsten target and Rhodium filter showed a variation of 24.5% at 20 keV. Mean 68 of SNR was increased in Selenia and mean 1.04 of SNR was raised in Senographe. Silicone pad was significantly effective to reduce the scatter ray that was generated by primary X-ray. It can decrease an absorption rate of scatter ray to patient body and whilst it improve the image quality from increasing SNR.

Analysis of Learning Effect through the Development and Application of Virtual Reality(VR) Education Content for Radiology Students (방사선과 학생을 위한 가상현실 교육콘텐츠 개발 및 적용을 통한 학습효과 분석)

  • Shim, Jae-Goo;Kwon, Soon-Moo
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.519-524
    • /
    • 2020
  • This study developed radiation therapy contents based on virtual reality technology and applied them to radiation students. A survey was conducted to analyze the relationship between learning effects and learning satisfaction to students who used virtual reality education videos to analyze their learning performance. 71 students radiology department were classified into two groups one that experienced virtual reality and the other that did not experienced virtual reality. We surveyed between the two groups analyzed self-directed learning, self-learning efficacy and learning satisfaction. As a result, the comparison between the two groups showed no difference between self-directed learning and self-learning efficacy. But the learning satisfaction was significant from 2.64±0.83 to 3.20±0.88 in the problem solving process for groups applying virtual reality contents. Therefore, learning satisfaction has improved experienced group virtual reality content and the materials for virtual reality education can be applied more efficiently in non-face-to-face lectures.

In Pediatric Leukemia, Dose Evaluation according to the Type of Compensators in Total Body Irradiation (소아백혈병 환자의 전신방사선조사 시 조직보상체의 재질변화에 따른 선량평가)

  • Lee, Dongyeon;Kim, Changsoo;Kim, Junghoon
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Total body irradiation(TBI) and chemotherapy are the pre-treatment method of a stem cell transplantations of the childhood leukemia. in this study, we evaluate the Quantitative human body dose prior to the treatment. The MCNPX simulation program evaluated by changing the material of the tissue compensators with imitation material of pediatric exposure in a virtual space. As a result, first, the average skin dose with the material of the tissue compensators of Plexiglass tissue compensators is 74.60 mGy/min, Al is 73.96 mGy/min, Cu is 72.26 mGy/min and Pb 67.90 mGy/min respectively. Second, regardless of the tissue compensators material that organ dose were thyroid, gentile, digestive system, brain, lungs, kidneys higher in order. Finally, the ideal distance between body compensator and the patient were 50 cm aparting each other. In conclusion, tissue compensators Al, Cu, Pb are able to replace of the currently used in Plexiglass materials.